An Experimental Study on Thermal and Environmental Characteristics of Various Heating Systems in the Residential House (주거용 건물의 난방 방식별 열적성능 및 실내환경 특성 평가를 위한 실험적 연구)

  • Lee, Choong-Kook;Cho, Sung-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.121-128
    • /
    • 2005
  • This is about experimental comparison study between convective heating and radiation heating system to use the design criteria for residential house. Experiment was done in EC(environment chamber) under simultaneous outdoor condition for 4 kinds of heating system such as CRHP(Ceiling Radiant Heating Panel), BEHC( Bottom Electric Heating Coil Mat), EFCU( Electric Fan Coil Unit) and CEHU( Convective Electric Heating Unit). Result show that CRHP ,which is radiation heating system, can consume more 23% energy than convective heating system when it is operated by dry bulb temperature but can save 1 ${\sim}$ 10% when operated by glove temperature and 27% when operated by MRT.

  • PDF

난방운전의 최적제어방안 중심 공동주택의 열성능 향상 방안

  • 이승언;안태경;강재식
    • 월간 기계설비
    • /
    • s.46
    • /
    • pp.74-89
    • /
    • 1994
  • 현재 범국가적 차원에서 지속적인 국가 경제 발전과 국제수지 개선을 위하여 추진되고 있는 정부의 에너지 절약사업에서 건물부문이 차지하는 에너지절약 효과는 막중하다. 특히 전체주택에서 공동주택이 차지하는 비율은 1990년에 32.1$\%$, 서울시의 경우 51.3$\%$로 전체 주택의 과반수를 넘어섰으며, 수도권의 대단위 아파트단지의 개발과 함께 공동주택의 증가추세는 당분간 지속될 전망이다. 본 연구는 공동주택의 최적난방 운전기법 개발을 위한 1차년도의 연구로서 현행 공동주택의 난방운전 실태를 조사, 분석하고 각 난방법에 따른 문제점 및 최적제어 알고리즘의 개발을 위한 자료 도출을 주 목적으로 진행되었다. 1차년도에 수행된 연구의 주요 내용을 살펴보면 다음과 같다. 공동주택의 난방에너지 소비현상은 단지에 따라 최대 3배이상의 열사용량에 차이가 있는 것으로 나타났다. 열사용량의 차이는 건축의 기본 열성능, 설비시설의 수준 및 노후화정도에 영향을 받으나 동일 연대의 단지들에서도 최대 80$\%$이상의 열사용량이 차이를 보이고 있었으며 이는 기계실 및 각 세대의 난방운전방법 및 제어수준에 따른 것으로 평가되었다. 세대의 층별, 위치별 열사용량 분석에 의하면 층별 열사용량차이가 큰 것으로 분석되었으며, 특히 최상층부와 최하층부의 열사용량이 뚜렷이 많이 나타나 단열성능의 강화가 요구되는 것으로 나타났다. 한편 샘플단지에 대한 측정 데이터를 통해 적정 열량공급시간대의 설정과 외기온의 변화에 따른 적정 온수공급온도의 설정조건 및 유량제어 효과등에 대한 분석 및 검토를 하였으며, 이를 통해 2차년도의 개발목표인 최적운전제어 방안의 제시를 위한 자료를 구축하였다. 또한 각 세대의 기밀성능이 공동주택의 열성능에 미치는 영향을 도출하기 위하여 샘플단지에 대해 트레스가스 측정법과 Blower Door법에 의하여 환기 및 기밀상태를 평가 하였으며 측정주호에 대한 환기를 예측할 수 있는 환기예측평가식을 제시하였다.

  • PDF

Characteristics of the Air Heat Exchanger for the Improvement of the Heat Pump COP (열펌프 성능향상을 위한 공기 열교환기 특성)

  • 노정근;송현갑;박용규
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.151-157
    • /
    • 2002
  • 화석에너지에 대한 경제적 부담과 환경오염문제를 줄이기 위하여 열펌프의 성능계수향상을 위하여 냉온 공기열교환기(HEEVA)를 고안하였고, 이 열교환기의 열특성과 성능계수향상에 미치는 영향을 분석하기 위하여 냉.난방 실험을 수행하였다. HEEVA에 의한 찬 공기와 더운 공기의 온도변화, 전열량 및 냉온 공기열교환기 효율, 총열전달계수등을 측정분석하였고, 냉난방시 외기온에 따른 열펌프의 성능계수, 소비전력, 응축기.증발기 출구 공기토출 온도 변화를 측정 분석함으로서 다음과 같은 결과를 얻을 수 있었다. 1. 외기온이 -4~11$^{\circ}C$로 변할 때 열펌프의 난방과정에서 HEEVA 찬공기 입출구 온도차는 4.5$^{\circ}C$에서 9.$0^{\circ}C$로 증가하였으며, HEEVA에 의한 영향으로 2~6$^{\circ}C$상승된 공기가 증발기 입구로 유입되어 냉매증발을 촉진하였다. 2. 실온이 4~22$^{\circ}C$일 때 HEEVA 더운공기 입출구 온도차는 3$^{\circ}C$에서 7$^{\circ}C$로 증가하였으며, 응축기에 유입되는 공기온도를 3~8$^{\circ}C$낮게 함으로서 압축기 소모전력을 감소시켜 COP 상승 효과를 나타냈다. 3. 외기온과 실온변화에 따라 풍량 346m$^3$/hr의 찬 공기가 받은 열량과 풍량 747m$^3$/hr의 더운 공기가 준 열량간의 차는 50~150kcal/hr로 나타났으며, 더운 공기가 준열량과 찬 공기가 받은 열량의 비가 83~98% 이었으므로 HEEVA의 열 교환율은 91% 을 보였다. 4. 총합열전달계수는 이론값이 실험 값보다 1~3W/m$^2$K 크게 나타났으며, 이 결과는 두 값 사이에 10% 내.외의 편차로서 Nusselt수를 구하기 위한 Petukhov상관식의 자체오차 15%에 비해 크지 않은 오차범주에 속하며, 이론상의 총합열전달계수 유도식의 타당성을 입증한 것이라 하겠다. 5. HEEVA를 작동함으로서 난방시 COP가 HEEVA를 작동하지 않았을 경우보다 0.3~0.5 향상된 것으로 나타났다. 이것은 HEEVA가 겨울철 난방에 효율을 높일수 있는 것으로 판단된다.

  • PDF

Energy Consumption Patterns for Various Building Types in Taejon (대전지역의 건물별 에너지 소비패턴에 대한 실태조사)

  • Kim, B.S.;Kim, Y.D.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.41-50
    • /
    • 1998
  • The purpose of this study is to analyze the energy consumption status for various building types in Taejon. 35 sample buildings were classified into 8 building types, i.e., sports center & swimming pools, hotels, telecommunication exchange service facility, hospitals, research laboratories, department stores, exhibition galleries, universities. According to analyses, energy consumption patterns varies significantly for each building type. Sports centers consumes highest rate(689 $Mcal/sqm{\cdot}yr$) and universities lowest rate(86 $Mcal/sqm{\cdot}yr$) among selected building types.

  • PDF

Application Effect of Heating Energy Saving Package on Venlo Type Glasshouse of Paprika Cultivation (파프리카 재배 벤로형 유리온실에서 난방에너지 절감 패키지 기술 적용효과)

  • Kwon, Jin Kyung;Jeon, Jong Gil;Kim, Seung Hee;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.225-231
    • /
    • 2016
  • Glasshouse heating package technologies to improve energy usage efficiency in winter were developed. Heating package was composed of the ground water source heat pump with heating capacity of 105kW, the aluminum multi-layer thermal curtain with six layers of different materials and the root zone local heater with XL pipes of ${\phi}20mm$. Venlo type glasshouse($461m^2$) with the heating package was compared with the same type and area control glasshouse with the light oil boiler, the usual non-woven fabric thermal curtain with respect to the glasshouse inside temperature, relative humidity, crop growth, and heating energy consumption. The results of test in paprika cultivation glasshouses showed that the air temperature inside glasshouse with aluminum multi-layer thermal curtain was maintained $2.2^{\circ}C$ higher than that of control glasshouse in un-heating night time and the temperature in bed with root zone local heating was $4.7^{\circ}C$ higher than that in bed without local heating. Average heating coefficient of performance(COP) of the ground water source heat pump used in paprika cultivation was 3.7 and the glasshouse inside temperature was maintained at $21^{\circ}C$ of heating set up temperature. The heating energy consumptions per 10a were measured at 14,071L of light oil and 364kWh of electric power for the control glasshouse and 35,082kWh for the glasshouse applied heating package. As results, the heating cost of the glasshouse applied heating package was 87 percent lower than that of control glasshouse. The growths of paprika in glasshouses of control and applied heating package did not show any significant difference.