• Title/Summary/Keyword: 난방 도일

Search Result 123, Processing Time 0.028 seconds

Prediction of Heating Load for Optimum Heat Supply in Apartment Building (공동주택의 최적 열공급을 위한 난방부하 예측에 관한 연구)

  • Yoo, Seong-Yeon;Kim, Tae-Ho;Han, Kyou-Hyun;Yoon, Hong-Ik;Kang, Hyung-Chul;Kim, Kyung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.803-809
    • /
    • 2012
  • It is necessary to predict the heating load in order to determine the optimal scheduling control of district heating systems. Heating loads are affected by many complex parameters, and therefore, it is necessary to develop an efficient, flexible, and easy to use prediction method for the heating load. In this study, simple specifications included in a building design document and the estimated temperature and humidity are used to predict the heating load on the next day. To validate the performance of the proposed method, heating load data measured from a benchmark district heating system are compared with the predicted results. The predicted outdoor temperature and humidity show a variation trend that agrees with the measured data. The predicted heating loads show good agreement with the measured hourly, daily, and monthly loads. During the heating period, the monthly load error was estimated to be 4.68%.

2002년도 전력소비동향 분석 2002년 전력소비량은 전년대비 $8.0\%$ 증가

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.315
    • /
    • pp.7-9
    • /
    • 2003
  • 2002년도 전력소비량은 2,785억kW로서 작년보다 $8.0\%$ 증가하였으며, 12월중 소비량은 248억kW($8.2\%$증가)로 월간 최대를 기록하였다. 이처럼 전력수요가 크게 증가한 것은 8, 9월중 많은 강우와 저기온 영향으로 냉방수요 증가가 둔화되었음에도 불구하고, 10월부터 일찍 시작된 한파의 영향으로 난방전력 수요가 크게 증가한 때문으로 판단된다. $\divideontimes$겨울철 난방전력 민감도 조사에 의하면 총난방전력수요는 665만kW이며, 겨울철 기온이 $1^{\circ}C$하락함에 따라 31만kW의 난방전력이 증가하는 것으로 나타났다. 2002년도 용도별 소비량은 주택용이 $11.8\%$의 높은 증가율을 보였는데 이는 심야전력($24.9\%$ 증가)을 비롯한 난방전력의 수요가 증가한 때문이다. 또한 일반용($9.1\%$ 증가) 및 교육용($11.9\%$ 증가)도 건실한 증가율을 나타냈다. 한편, 산업용전력은 반도체, 기계장비 및 자동차업종 등 수출주도형 업종의 소비량은 높았으나, 소비 비중이 높은 화학제품 및 섬유업종의 전력소비 둔화로 평균증가율보다 낮은 $6.4\%$ 증가에 그쳤다. 그러나 전체 전력소비량에서 차지하는 비중은 $54.3\%$(1,512억kW)로 여전히 제일 높았다. 지역별로는 수도권이 1,049억kWh를 소비하여 전체의 $37.7\%$ 부산$\cdot$경남은 532억kWh로서 $19.1\%$를 점유하였다.

  • PDF

Study on the Revision of HDD for 15 Main Cities of Korea (국내 15개 주요지역의 난방도일 재산정에 관한 연구)

  • Cho, Sung-Hwan;Kim, Seong-Su;Choi, Chang-Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.436-441
    • /
    • 2010
  • The purpose of this study is to revise the HDD(Heating Degree-Days) of main cities of Korea because the outside temperature rise have been accelerated by global warming recently. Now our HDD(Heating Degree-Days) for the utility design of district heating system had been `established in 20 years ago. Therefore new heating degree days for main cities of korea had been required and determined using long-term measured outside weather temperature data during 30 years. For the analysis of HDD, five different base temperatures ranging from 24 to $16^{\circ}C$ were chosen in the calculation of heating degree days. And new yearly heating degree days of 15 cities of korea were given in the tabular form.

Study on the revision of HDD for 15 District Areas of Korea (국내 주요지역의 난방도일 재산정에 관한 연구)

  • Cho, Sung-Hwan;Kim, Seong-Su;Kim, Sang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.943-948
    • /
    • 2008
  • Global average temperature rise accelerates by global warming in the three decades of the 20th century. But Current HDD ( Heating Degree-Days) which we are using has been established 20 years ago. Therefore new heating degree days for 15 district areas of korea was determined using long-term measured data. Five different base temperatures ranging from 24 to $16^{\circ}C$ were chosen in the calculation of heating degree days. And yearly heating degree days were given in the tabular form.

  • PDF

Study on the revision of Heating Degree-days for Korea (국내 난방도일의 재정립에 관한 연구)

  • Kim, Seong-Su;Cho, Sung-Hwan;Choi, Chang-Yong;Kim, Sang-Ho;Kim, Youn-Hong
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.17-22
    • /
    • 2007
  • Global average temperature rise accelerates by global warming in the three decades of the 20th century. But now we use heating degree days which was established 20 years ago. Therefore new heating degree days for 15 district areas of korea was determined using long-term measured data. Five different base temperatures ranging from 24 to $16^{\circ}C$ were chosen in the calculation of heating degree days. And yearly heating degree days were given in the tabular form.

  • PDF

Floor Heating Characteristics of Latent Heat Storage-Bioceramic Ondal - Focused on Historical research and Expermental Analysis - (잠열 축열-바이오 세라믹 온돌의 난방 특성 - 온돌의 역사적 고찰 및 실험적 분석을 중심으로 -)

  • Sone, Hyun-Kap;Ryon, Young-Sun
    • Solar Energy
    • /
    • v.15 no.1
    • /
    • pp.13-28
    • /
    • 1995
  • In this study, the history of Korean traditional Ondol was investigated and the latent heat materials and bioceramics were selected to develop the latent heat storage-bioceramics Ondol system based on the Korean traditional Ondol(sensible heat storage type), and the thermal characteristics of Ondol were analyzed experimentally The results could be summarized as follows; 1. Korean traditional Ondol has been originated in "Whaduk" which had been utilized continuously for about $2{\times}10^6$ years from the Old Stone Age to the Bronze Age, and Korean traditional Ondol using in these days has been utilized for about 976 years from the Koryu Dynasty to the Modern Ages. 2. $Na_2SO_4{\cdot}10H_2O(SSD)$ was selected as latent heat material for the latent heat storage Ondol. 3. Ondol unit was filled with the latent heat material of 0.63 kg and the dimension of Ondol unit was $400mm{\times}400mm{\times}27mm(width{\t\imes}depth{\times}height)$. 4. The comfortable surface temperature($23{\sim}29^{\circ}C$) of the latent heat storage Ondol was lasted 5 hours at the room temperature of $16{\sim}18^{\circ}C$, whereas that of sensible heat storage Ondol was lasted only 1.0 hours in the same conditions. 5. For the thermal effect of bioceramics, the Ondol air temperature i.n case of bioceramics treatment on the pannel was higher than that of without bioceramics treatment.

  • PDF

법령과 고시 - 주택건설기준 등에 관한 규정 개정

  • 대한기계설비건설협회
    • 월간 기계설비
    • /
    • s.316
    • /
    • pp.42-43
    • /
    • 2016
  • 국토교통부는 공동주택 결로 발생에 따른 입주자의 불편을 해소하기 위해 주택건설기준 등에 관한 규정을 개정하고 지난 10월 25일 시행에 들어갔다. 특히 국토교통부는 이번 개정을 통해 침실에 설치되는 옷방 또는 붙박이 가구의 벽체와 천장의 접합부위에 대해서도 결로방지 상세도를 작성하도록 하고, 공동주택 각 세대에 온돌 방식의 난방설비를 하는 경우에는 옷방 또는 붙박이 가구의 설치 공간에도 난방설비를 하도록 했으며, 침실에 설치되는 밀폐된 옷방 또는 붙박이 가구에는 외벽 및 욕실과 이격된 경우를 제외하고 배기설비 또는 통풍구를 설치토록 했다.

  • PDF

가정용 천연가스의 소비행태에 관한 연구 - 필수재의 특성을 중심으로 -

  • Kim, Yeong-Deok
    • Environmental and Resource Economics Review
    • /
    • v.7 no.2
    • /
    • pp.171-200
    • /
    • 1998
  • 천연가스의 소비실태를 조사하기 위하여 실시한 표본조사자료를 이용하여 가정용 천연가스의 소비가 실증적으로 필수재의 성격을 가지는지를 조사하였다. 이를 위해 가장 일반적인 개념인 천연가스 소비의 소득에 대한 탄력성을 추정하였고, 다른 에너지와의 상대적인 비교를 위하여 광열비 지출에서의 천연가스 소비비 중의 소득에 대한 민감도를 추정하여 광열비 일반에 대한 천연가스 소비의 상대적 필수재의 성격을 파악하였고, 가정용 천연가스의 용도인 취사용과 난방용의 상대적 필수재 특성을 살피기 위하여 가스의 위험인지도에 대한 천연가스의 용도별 반응을 추정하였다. 이로부터 얻은 결과는 다음과 같다. 우선, i) 가정용 천연가스의 소비는 일반적으로 용도에 관계없이 필수재의 성격을 지니고 있으며, ii) 다른 에너지원과 비교를 위한 광열비에서의 천연가스 소비비 중의 소득 변화에 대한 반응을 보았을 때, 모형에 따라 다르나, 취사용이나 난방용이나 광열비 일반에 비하여 필수재 성격을 가진 것으로 나타나고 있으며, iii) 취사용 천연가스의 소비가 상대적으로 난방용에 비하여 필수재의 성격을 가진 것으로 나타나고 있다.

  • PDF

난방운전의 최적제어방안 중심 공동주택의 열성능 향상 방안

  • 이승언;안태경;강재식
    • 월간 기계설비
    • /
    • s.46
    • /
    • pp.74-89
    • /
    • 1994
  • 현재 범국가적 차원에서 지속적인 국가 경제 발전과 국제수지 개선을 위하여 추진되고 있는 정부의 에너지 절약사업에서 건물부문이 차지하는 에너지절약 효과는 막중하다. 특히 전체주택에서 공동주택이 차지하는 비율은 1990년에 32.1$\%$, 서울시의 경우 51.3$\%$로 전체 주택의 과반수를 넘어섰으며, 수도권의 대단위 아파트단지의 개발과 함께 공동주택의 증가추세는 당분간 지속될 전망이다. 본 연구는 공동주택의 최적난방 운전기법 개발을 위한 1차년도의 연구로서 현행 공동주택의 난방운전 실태를 조사, 분석하고 각 난방법에 따른 문제점 및 최적제어 알고리즘의 개발을 위한 자료 도출을 주 목적으로 진행되었다. 1차년도에 수행된 연구의 주요 내용을 살펴보면 다음과 같다. 공동주택의 난방에너지 소비현상은 단지에 따라 최대 3배이상의 열사용량에 차이가 있는 것으로 나타났다. 열사용량의 차이는 건축의 기본 열성능, 설비시설의 수준 및 노후화정도에 영향을 받으나 동일 연대의 단지들에서도 최대 80$\%$이상의 열사용량이 차이를 보이고 있었으며 이는 기계실 및 각 세대의 난방운전방법 및 제어수준에 따른 것으로 평가되었다. 세대의 층별, 위치별 열사용량 분석에 의하면 층별 열사용량차이가 큰 것으로 분석되었으며, 특히 최상층부와 최하층부의 열사용량이 뚜렷이 많이 나타나 단열성능의 강화가 요구되는 것으로 나타났다. 한편 샘플단지에 대한 측정 데이터를 통해 적정 열량공급시간대의 설정과 외기온의 변화에 따른 적정 온수공급온도의 설정조건 및 유량제어 효과등에 대한 분석 및 검토를 하였으며, 이를 통해 2차년도의 개발목표인 최적운전제어 방안의 제시를 위한 자료를 구축하였다. 또한 각 세대의 기밀성능이 공동주택의 열성능에 미치는 영향을 도출하기 위하여 샘플단지에 대해 트레스가스 측정법과 Blower Door법에 의하여 환기 및 기밀상태를 평가 하였으며 측정주호에 대한 환기를 예측할 수 있는 환기예측평가식을 제시하였다.

  • PDF