• 제목/요약/키워드: 난방에너지 소비량

검색결과 63건 처리시간 0.024초

공동주택의 에너지소비량 및 난방운전 실태에 관한 조사연구 (An investigation on the heating energy consumption and operating condition in apartment houses)

  • 신용태
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 1994년도 학술발표대회논문집 상
    • /
    • pp.45-50
    • /
    • 1994
  • The energy consumption in apartment houses is investigated according to the heating systems, that is, district, central, and individual heating systems. And, operating conditions of intermittent heating are surveryed and analysed in the central heating systems. As a result, each annual energy consumption of district, central and individual heating system is 143.56 Mcal/m2year, 216.78 Mcal/m2year and 150.68 Mcal/m2year, Also, the heating is generlly started at 04:00 and 17:00 of each day, and the heating system is operated for 2~3 hours per each time.

  • PDF

공기열원 히트펌프의 에너지원으로서 지하철 배열 이용에 관한 연구 (A study on the utilization of exhausted heat from subway for energy source of heat pump)

  • 김종렬;정기철
    • 한국가스학회지
    • /
    • 제4권4호
    • /
    • pp.13-19
    • /
    • 2000
  • 지구환경 보존 및 화석연료의 고갈에 대한 대책으로 미활용 에너지원에 대한 연구들이 진행되고 있다. 본 연구는 이러한 관점에서 지하철에서 배기되는 공기를 공기열원 히트펌프의 열원으로 이용할 수 있는가를 알아보기 위해 서울 지하철 5호선 Y역을 대상역으로 선정하여 터널내의 공기온도, 배열량을 시뮬레이션하였다. 이 배열량을 난방용 열원으로 히트펌프에 이용했을 경우 전력소비량과 대기를 직접 이용하는 히트펌프의 전력소비량을 계산하여 에너지 절약량을 검토하였으며, 여름철 냉방 유무 및 환기시간에 따른 터널내 온열환경을 파악하였다.

  • PDF

바닥복사 난방시스템의 밸브구동 특성을 고려한 실내 열환경 성능 개선 연구 (A Study on the Improvement of Indoor Thermal Performance of Floor Radiant Heating System Considering Valve Operation Characteristics)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.36-45
    • /
    • 2021
  • In this study, to improve the indoor thermal environment of the radiant floor heating system, a study was conducted on the temperature change characteristics and energy consumption according to the change of the indoor air set temperature, the supply hot water temperature and the outdoor temperature. As for the control method, the on/off control and the thermal difference proportional control method proposed through previous studies were applied. In addition, in consideration of field applicability, numerical analysis was performed for the case where the indoor air temperature sensor was affected by the wall temperature. As a result, it was found that the temperature difference proportional control method is more effective for thermal comfort and energy saving than on/off control.

친환경 건설정책 - 저에너지 친환경 공동주택 시대 열다 - 강동구, 저에너지 친환경 공동주택 가이드라인 확정 -

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • 통권236호
    • /
    • pp.48-51
    • /
    • 2010
  • 국토해양부(장관 정종환)는 최근 연세대 친환경건축연구센터와 서울시 강동구가 협의('09.8)를 통해 친환경 공동주택 가이드라인을 마련함에 따라 강동구부터 '저에너지 친환경 공동주택 가이드라인' 시행에 들어 간다고 밝혔다. 가이드라인의 주요내용은 공동주택 재건축시 냉 난방 에너지 총 소비량의 40% 이상을 절감하고, 관리동 등 공용시설의 제로에너지화, 지역특성에 맞게 생태면적률 40%이상 확보, 단지내 인공생물 서식공간 조성의 의무화 등이다. 강동구는 앞으로 지어지는 재건축정비사업의 공동주택 모두에 가이드라인 내용을 반영하여 친환경 공동 주택으로 건설을 추진할 계획이며, 특히 고덕지구($1,239,407m^2$, 18,540가구) 및 둔촌지구($626,235m^2$, 9,090가구)부터 적용하여 친환경공동주택단지를 조성할 전망이다.

  • PDF

이중금속융출형 온돌판넬을 이용한 바닥온수난방시스템의 난방성능과 에너지소비량에 관한 실험적 연구 (Experimental Study on Consumption of Energy and Heating Efficiency in Floor Water Heating System on Using Ondol Panel of Double Metal Rendering)

  • 배대권;김진봉;김환성
    • 한국산학기술학회논문지
    • /
    • 제13권12호
    • /
    • pp.6167-6175
    • /
    • 2012
  • 본 연구는 개발된 온돌판넬을 이용한 바닥난방공법의 품질검증을 위한 실험적 연구이다. 이를 위해 현행기술인 표준바닥구조에 의한 난방시스템과 본 개발기술의 난방성능을 측정비교 하였다. 그 결과, 온수온도 $45^{\circ}C$, 8시간 공급시 개발기술의 몰탈표면부 온도는 $49.4^{\circ}C$, 배관사이 중앙부는 $44.1^{\circ}C$, 공기층은 $25.3^{\circ}C$로 나타났다. 반면, 현행기술의 몰탈표면부는 $46.2^{\circ}C$, 배관사이 중앙부는 $37.7^{\circ}C$, 공기층은 $24.7^{\circ}C$로 나타났다. 한편, 온수온도 $45^{\circ}C$일 때 개발기술의 누적 에너지소비량은 4,646 kcal, 현행기술은 4,814 kcal로써 개발기술이 기존 기술보다 적게 나타났다.

바닥복사난방의 실별제어시스템에 관한 열성능 평가 (An Evaluation on the Thermal Performance of the Room Control System for Radiant Floor Heating)

  • 석호태;김오봉;조영흠;김광우;여명석
    • 한국주거학회논문집
    • /
    • 제14권5호
    • /
    • pp.75-82
    • /
    • 2003
  • In this study, the thermal performance of the room control system is analyzed in terms of control performance, potential for coil expansion and energy consumption through experiments comparing the individual room control system and an existing system. The results of this study show that the existing system is not able to supply design water flow rate and does not accurately maintain the set point temperature in each room. However, the individual room control system can set a room air temperature for each room, for it is able to supply design water flow and accurately control the set point temperature in each room and can reduce the energy consumption compared to the existing system. Moreover, the individual room control system can reduce the number of coil division zone and facilitates the construction process, because it can extend the length of the coil division.

바닥난방시스템의 외기온도 변화특성을 고려한 운전방안에 관한 연구 (A Study on the Operational Strategies for Outdoor Air Temperature Change Characteristics in a Radiant Floor Heating System)

  • 안병천;송재엽
    • 설비공학논문집
    • /
    • 제25권12호
    • /
    • pp.685-692
    • /
    • 2013
  • In this study, the control characteristics and effects of heating control methods on the heating performance and energy consumption of a hot-water heating control system of a residential apartment were researched by simulation and experiment. The purpose of this study is to evaluate operational strategies for improving an indoor thermal environment and reducing f energy consumption in the radiant floor heating system of a residential apartment.

실리카 에어로겔을 이용한 다겹보온커튼의 온실 난방 특성 분석 (Analysis of Heating Characteristics of Multi-Layered Insulation Curtain with Silica Aerogel in Greenhouses)

  • 진병옥;김형권;유영선;이태석;김영화;오성식;강금춘
    • 생물환경조절학회지
    • /
    • 제29권4호
    • /
    • pp.320-325
    • /
    • 2020
  • 본 연구는 최근 신소재 단열재로 주목받고 있는 실리카 에어로겔을 이용하여 현재 사용되고 있는 다겹보온커튼의 단점을 보완하고 보온성을 유지 및 향상시킬 수 있는 새로운 조합의 다겹보온커튼을 제작 하여 현장에 설치함으로써 보온성과 경제성을 분석하고자 한다. 실험에 사용된 다겹보온커튼은 실리카 에어로겔이 함유된 부직포를 사용하여 2가지의 조합으로 제작하였으며 시중에 판매, 사용되고 있는 관행 다겹보온 커튼과의 차이에 따른 온습도변화와 연료소비량을 측정하여 비교분석하였다. 실험결과 단동온실과 연동온실에서 다겹보온커튼 차이에 따른 온습도변화는 미세하게 나타났으나, 거의 비슷한 온습도 값을 유지하였다. 이는 실리카 에어로겔을 이용한 다겹보온커튼이 관행 다겹보온커튼에 비해 온습도 제어 측면에서 문제가 없음을 나타냈다. 난방에너지 비교분석 결과, 실리카 에어로겔을 이용한 다겹보온커튼이 관행 다겹보온커튼에 비해 연료소비량은 단동온실에서 약 15%, 연동온실에서 약 20%의 연료소비량을 절감한 것으로 나타나 온실의 규모와 사용기간이 증가함에 따라 난방에너지는 절감될 것으로 판단된다. 실리카 에어로겔 이용 다겹보온커튼이 관행 다겹보온커튼에 비해 통기성과 보온성이 증가되는 것이 확인되었다. 그러나, 연동온실에서 사용된 다겹보온커튼은 관행 다겹보온커튼에 비해 무게가 증가하고 뻣뻣하여 시공성과 작동성이 떨어지는 것을 확인할 수 있었다. 이에 단동온실에서 사용된 다겹보온 커튼에서는 개선사항을 적용하였다. 내부단열재의 교체를 통해 두께를 감소시키고 뻣뻣함을 개선함으로써 농가가 사용하기에 충분한 가능성이 있다는 것을 확인하였다.

착의량과 실내설정온도 관계에 따른 난방에너지 및 온실가스저감량 평가 연구 (A Study on the Estimation of Heating Energy and CO2 Reduction depending on a Indoor Set Temperature and Clo value)

  • 이철성;윤종호
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.49-54
    • /
    • 2010
  • Most energy using in building part is mainly consumed for heating and cooling to meet occupancy's comfort temperature. Generally, heating energy consumption show high value than cooling energy in Korea because of high temperature difference in winter season as compared with summer in apartment building. The efforts to develope mechanical performance have been studied to reduce energy consumption in building energy field until now. However, the energy consumption in building is impacted by not only system performance but also PMV particularly at temperature and Clo value. This means that energy consumption can be changed by occupancy's comfort setting temperature in apartment building. This study investigated the passibility of overheating in apartment building by occupant' slow Clo and its setting temperature from preceding research and then the heating energy consumption by setting temperature was calculated with ESP-r. The effects of heating energy and $CO_2$ reduction are also evaluated quantitatively with Clo value. The results showed that keeping ISO-7730 standards can reduce heating energy up to 21% in compared with option 2; also, wearing underclothes with ISO-7730 standard can considerably reduce heating energy consumption up to 50%. As compared with option 2, the reduction of $CO_2$ emission for option 3 showed 0.63TCO2 of kerosene, 0.49TCO2 of LNG and 1.09TCO2 of electricity. The option 4 can be reduced by 1.48TCO2 of kerosene, 1.16TCO2 of LNG and 2.57TCO2 of electricity respectively.

대형병원에서 마이크로터빈 이용한 열병합시스템 에너지성능 및 경제성 분석 (The Energy Performance & Economy Efficiency Evaluation of Microturbine Installed in Hospital buildings)

  • 김병수;길영욱;홍원표
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.176-183
    • /
    • 2009
  • 대형병원의 에너지 소비패턴을 분석한 후 마이크로가스터빈을 적용할 경우 기존 시스템 대비 냉난방에너지 절감량 및 전기에너지 절감량과 경제성분석을 통해 대형병원의 에너지 소비량을 절감하기 위한 에너지성능평가 모의연구를 수행하였다. 0.5[MW]급 마이크로 가스터빈을 설치한 후 에너지 성능분석을 한 결과 터빈에서의 발전효율은 30[%]이며, 전기는 건물에서 사용되는 조명에너지 뿐만 아니라 전체 전기에너지의 40[%]을 절감할 수 있는 것으로 분석되었다. 또한 터빈에서 발전되는 전기량과 배열을 냉난방에너지원으로 이용할 경우 전체 시스템효율은 70[%]로 상승할 뿐만 아니라 난방에너지의 56[%], 냉방에너지의 67[%]를 절감할 수 있는 것으로 분석되었으며 현가등가법에 의한 시스템 투자회수 기간이 약 9년으로 분석되었다.