• 제목/요약/키워드: 나선 유동

검색결과 86건 처리시간 0.026초

나선형 홈을 가진 브레이크 유로 내에서의 국소 열전달 측정 및 열 유동 해석 (Measurement of Local Heat Transfer Coefficients and Numerical Analysis in the Flow Passage of Disc Brake with Spirally Grooved Surfaces)

  • 이대희;박성봉;임창율;김흥섭;이관수
    • 한국자동차공학회논문집
    • /
    • 제14권6호
    • /
    • pp.104-111
    • /
    • 2006
  • A ventilated disc brake having spirally fluted surface has been proposed to improve the thermal judder by way of heat transfer enhancement. The local heat transfer coefficients were measured in the flow passage of disc brake. These measured local heat transfer data were utilized to do the finite element numerical analysis which predicts the maximum temperatures on the disc brake. The results show that the maximum temperatures on the disc surface with spirally fluted surface are approximately 26.6% lower than those without them.

나선형 파형강관에서의 유동특성 및 압력강하 예측 (Prediction of Flow Behavior and Pressure Drop of Spirally Corrugated Steel Pipe)

  • 박종학
    • 한국전산유체공학회지
    • /
    • 제9권2호
    • /
    • pp.18-22
    • /
    • 2004
  • Numerical investigation has been conducted to figure out flow behavior and pressure drop characteristics of spirally corrugated steel pipe which is widely used in civil, industrial and agricultural field owing to many advantages such as good corrosion resistance and durability, strength, easy and quick installation. Also the poly-ethylene coating spirally corrugated steel pipe has the long life under condition of sea water immerged. In the present study, flow behavior in the spirally corrugated pipe and influence of P/d/sub h/(ratio of wave pitch to hydraulic diameter) to pressure drop are investigated by CFD with various Reynolds number. And also friction factor is estimated by pressure drop obtained by flow analysis. According to computation results, the flow runs spirally up and down along the spiral corrugation in the vicinity of wall, but the effect of spiral corrugation disappears in core region of pipe. As P/d/sub h/ becomes small, more pressure drop occurs in spirally corrugated Pipe. Besides, friction factor augmentation becomes much larger as Re increases. In case of p/d/sub h/=0.38, Pressure drop and friction factor of spirally corrugated pipe are about four times larger than smooth pipe at Re: 1.46×10/sup 6/.

나선형 핀이 내부에 부착된 관의 형상최적화 (Shape Optimization of Internally Finned Tube with Helix Angle)

  • 김양현;하옥남;이주희;박경우
    • 설비공학논문집
    • /
    • 제19권7호
    • /
    • pp.500-511
    • /
    • 2007
  • The Optimal solutions of the design variables in internally finned tubes have been obtained for three-dimensional periodically fully developed turbulent flow and heat transfer. For a trapezoidal fin profile, performances of the heat exchanger are determined by considering the heat transfer rate and pressure drop, simultaneously, that are interdependent quantities. Therefore, Pareto frontier sets of a heat exchanger can be acquired by integrating CFD and a multi-objective optimization technique. The optimal values of fin widths $(d_1,\;d_2)$, fin height(h) and helix angle$(\gamma)$ are numerical1y obtained by minimizing the pressure loss and maximizing the heat transfer rate within ranges of $d_1=0.5\sim1.5mm$, $d_2=0.5\sim1.5mm$, $h=0.5\sim1.5mm$, and $\gamma=0\sim20^{\circ}$. For this, a general CFD code and a global genetic algorithm(GA) are used. The Pareto sets of the optimal solutions can be acquired after $30^{th}$ generation.

나선코일튜브내의 강제대류 열전달에 관한 연구 (Study on forced convective heat transfer in helically ceiled tubes)

  • 한규일;박종운;임태우
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.282-291
    • /
    • 1998
  • Heat transfer performance are studied for the turbulent flow of water in 3 smooth tube coils having ratios of coil to tube diameter of 16, 21 and 27, and a corrugated-coiled tube having a ratio of coil to tube diameter of 29, for Reynolds numbers from 8000 to 60000 and is also compared with the limited results available to data. The experiments are carried out for the fully developed turbulent flow of water in tube coils under the condition of uniform heat flux. This work is limited 0 tube coils of R/a between 10 and 30. The tube having a ratio of coil to tube diameter of 27 among the 3 smooth tube coils shows the best heat transfer performance. The performance of coiled tube best transfer performance. The performance of coiled tube with a similar curvature ratio is better for a corrugated-coiled tube(R/a=17) than for a smooth coiled tube(R/a=16). An empirical relation which correlates most of the data within $\pm$25% was also developed. Test result shows that the Nusselt number is found to be affected by a secondary flow due to curvature.

  • PDF

수평 회전 히트파이프에서 내부 삽입 코일이 유동 형태 및 열전달 성능에 미치는 영향에 대한 실험 연구 (An experimental study on the effects of an inserted coil on flow patterns and heat transport performances for a horizontal rotating heat pipe)

  • 이진성;김철주;김선주;문석환
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.763-772
    • /
    • 1998
  • The effects of an inserted coil on flow patterns and heat transport performance for a horizontal rotating heat pipe have been studied experimentally. Especially, the present study is to see an internally inserted helical coil inside a RHP would lead to the same kind of results as internal fins. Visualization test conducted for an acryl tube, charged water with at a volumetric rate of 20%. When the flow kept pool regime at a low RPM(less than 1,000 RPM), the movement of coil forced the water to flow in axial direction. But this pumping effect of coil disappeared, when the pool regime changed to annular one which could be created by increasing RPM. The pumping effects for RHP with an inserted coil resulted enhancement both in condensation heat transfer coefficient and heat transport limitation, as obtained in case of using internal fins. But all these effects became negligible in the range of higher RPM(above 1,000∼1,200) with the transition of flow regime to annular flow.

  • PDF

PIV 계측과 CFD 해석을 통한 오일펜스 만곡부 단면에서의 유동장 특성 (Characteristics of Flow Field at Curved Section of Oil Fence using PIV Measurements and CFD Simulations)

  • 김태호;장덕종;나선철;배재현;김대안
    • 해양환경안전학회지
    • /
    • 제17권1호
    • /
    • pp.29-37
    • /
    • 2011
  • 유속의 변화에 따른 오일펜스 만곡부 후면의 속도장과 압력장, 와도 및 난류 강도를 계측한 PIV 실험의 결과 유속이 증가함에 따라 유동 경계역의 후면부에서의 흐름 방향이 전면부의 흐름 방향에 가까워지는 현상이 나타났고, 압력 분포의 양상이 달라졌으며 난류도 더욱 불규칙적인 형태로 나타났다. PIV 실험과 동일 조건으로 수행한 CFD 해석 결과, 후류의 유동 패턴이 0.3m/s이하의 저속인 경우는 PIV 실험 결과와 유사하게 나타났으나, 유속이 0.4m/s일 때는 오일펜스 자체의 유연성으로 인해 다소 차이가 나타났고, 오일펜스 하단의 압력차로 인한 불규칙한 난류가 수면까지 영향을 주었다.

비대칭 3차원 핀틀 노즐의 연결관 각도와 핀틀 위치에 대한 성능 특성 해석 (Performance Characteristics Analysis of a Three Dimensional Asymmetric Pintle Nozzle Induced by Connection-Tube Angle and Pintle Stroke Position)

  • 이강민;홍지석;성홍계;허준영;진정근;하동성
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.383-387
    • /
    • 2017
  • 비대칭 3차원 핀틀 노즐 형상에서 연소실과 핀틀 노즐의 연결관 각도와 핀틀 위치가 성능계수에 미치는 영향을 분석하기 위해 3차원 수치해석을 수행하였다. 초음속 노즐을 통해 배출되는 유동 특성을 정확히 예측하기 위하여 $k-{\omega}$ SST의 압축성 보정 난류모델을 적용하였다. 비대칭 3차원 형상에 의한 복잡한 유동 구조로 인하여 나선형 형태의 유선과 유동 박리가 관찰되었으며, 이로 인하여 유동의 전압력 손실이 크게 발생되었다. 유입관의 각도가 감소할수록 성능계수가 증가하였으며, 핀틀의 위치에 따른 유동구조가 크게 변화되기 때문에 이에 대한 성능 특성을 분석하였다.

  • PDF

뇌동맥류 모델에 대한 혈류역학 해석 (Computational Hemodynamics in the Intracranial Aneurysm Model)

  • 서태원;변준수
    • 대한기계학회논문집B
    • /
    • 제37권10호
    • /
    • pp.927-932
    • /
    • 2013
  • 뇌동맥류모델은 CT 영상을 기반으로 추출하여, ANSYS-FLUENT를 사용해 전산 유체유동해석을 수행하였다. 본 연구를 통해 뇌동맥류에서 최소 벽전단응력은 동맥류가 발생한 영역에서 일어나는 것을 알 수 있다. 또한 뇌동맥류 모델에서 우측중뇌동맥 안쪽벽면에 작용하는 벽전단응력의 크기는 동맥류 전부와 후부의 벽면에 작용하는 벽전단응력의 크기에 비해 20 배 더 크게 발생하는 것을 알 수 있다. 그러나 동맥류 영역에서의 전단응력의 크기는 매우 작게 나타났다. 혈관 수축이 일어나는 동안 동맥류의 영역에서 매우 복잡한 이차유동이 발생하는 것을 볼 수 있다. 동맥류 내부에서의 혈류유동은 나선형 유동형태를 보이며, 본 연구의 혈류역학적 특성 분석을 통해 뇌동맥류의 파열을 예견할 수 있을 것으로 판단한다.

안쪽축이 회전하는 환형관내 비뉴튼 유체의 천이 유동 연구 (Transitional Flow study on non-newtonian fluid in a Concentric Annulus with Rotating Inner Cylinder)

  • 김영주;황영규;권혁정;서병택;황인주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.324-329
    • /
    • 2001
  • This experimental study concerns the characteristics of a transitional flow in a concentric annulus with a diameter ratio of 0.52, whose outer cylinder is stationary and inner one rotating. The pressure losses and skin-friction coefficients have been measured for the fully developed flow of $0.1\sim0.4%$ aqueous solution of sodium carbomethyl cellulose (CMC), respectively at inner cylinder rotational speed of $0\sim600rpm$. The transitional flow has been examined by the measurement of pressure losses to reveal the relation of the Reynolds and Rossby numbers with the skin-friction coefficients. The present results show that the skin-friction coefficients have the significant relation with the Rossby numbers, only for laminar regime. The occurrence of transition has been checked by the gradient changes of pressure losses and skin-friction coefficients with respect to the Reynolds numbers. The increasing rate of skin-friction coefficients due to the rotation in uniform for laminar flow regime, whereas it is suddenly reduced for transitional flow regime and, then, is gradually declined for turbulent flow regime. Consequently, the critical(axial-flow) Reynolds number decrease as the rotational speed increases. Thus, the rotation of inner cylinder promotes the early occurrence of transition due to the onset of taylor vortices.

  • PDF

헬리컬관외 침전 및 적하 열전달 특성에 관한 연구 (Study on the Heat Transfer Characteristics of Immerged and Falling Flows on Helical Tubes)

  • 황승기;윤상국;김동혁;이승갑
    • 설비공학논문집
    • /
    • 제13권4호
    • /
    • pp.225-232
    • /
    • 2001
  • An experimental study is carried out to investigate the characteristics of heat transfer of outside helical tubes. The main heat exchanger consists of twelve curved columns with each 300mm diameter and the total length of 1.2m copper tube having an outer diameter of 19.05mm with 1.5mm thickness. Water flows down the outside of helical tube, where flow patterns are the vertical film falling flow, immerged flow, and mixed-flow which is the combination of film falling flow and immerged flow. Refrigerant 11 flow the inside of the tube countercurrently. The experimental range of inside flow rate is 1.7~3.2$\ell$/min and outside flow rate is 21-33$\ell$/min. The results are presented as Nusselt number with corresponding Reynolds number for variety of outside and inside flow rates. The heat transfer rates of the mixed flow are 8 to 56% higher than those of film falling flow or immerged flow only. Interpretation of the results is given on the basis of physical reasoning and the correlation equations.

  • PDF