• 제목/요약/키워드: 나사 유지형 보철 물

검색결과 25건 처리시간 0.024초

임플랜트 상부 보철물의 고정 방식에 따른 힘의 분포에 관한 연구 : 나사 유지형 대 시멘트 유지형 (A COMPARISON OF LOAD TRANSFER IN SCREW- AND CEMENT-RETAINED IMPLANT FIXED PARTIAL DENTURE DESIGNS)

  • 이주희;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제39권2호
    • /
    • pp.125-145
    • /
    • 2001
  • To compare the stress distribution patterns between cement-retained and screw-retained implant supported fixed prostheses according to four different abutment types, a three dimensional finite element analysis was performed. The hypothetical three unit fixed partial denture case was modelled on the three implants(10mm length and 3.75 diameter) in mandibular bone. Four angles of implantation(vertical, 10, 15 and 20 degree inclined mesially) were created and three different directions of force (vertical, oblique, horizontal) were applied at the center of the second premolar and distal end of the first molar for each cases. Within the limits of this study, the results were as follows, 1. In vertically installed cases, the more stress was concentrated at upper components, but mesially inclined cases, the more stress was concentrated at cortical bone. 2, The more inclined mesially the more stress was observed, especially at cortical bone. 3. The cement-retained models showed lower principal stress and more even stress distribution than the screw-retained models. 4. The similar stress distribution pattern was showed in model 1 and model 2, model 3 and model 4. 5. The more stress was observed when the loads were applied at the distal end of 1st molar than the center of 2nd premolar. 6 The fixture and the model as a whole, lesser stress values were observed when vertical loads were applied as compared to horizontal and oblique loads.

  • PDF

디지털 임플란트 플래닝을 통한 최소침습 보철수복 증례 (Prosthetic rehabilitation with digital implant planning for a minimally invasive surgery approach)

  • 정아름;이영후;홍성진;백장현;노관태;배아란;김형섭;권긍록
    • 대한치과보철학회지
    • /
    • 제60권3호
    • /
    • pp.283-292
    • /
    • 2022
  • 임플란트를 이용한 고정성 보철 치료를 위해서는 보철 치료에 적합한 위치에 임플란트가 식립되어야 하며 이를 위해 guided implant surgery와 CAD-CAM을 활용한 보철물 제작이 최근 널리 사용되고 있다. 수술 시에는 surgical guide를 이용해 flapless 방식으로 최소침습 보철수복이 가능 하다. 본 증례의 환자는 86세 남성 환자로 기존 의치 사용 시 불편함으로 치료를 원하였다. 환자는 전신질환으로 인해 가철성 국소의치 사용이 어려워 상악은 총의치, 하악의 경우 임플란트 고정성 보철물 수복하였다. 전신질환으로 인해 높은 출혈 위험성을 가지므로 surgical guide를 사용해 flapless 방식으로 임플란트를 식립하였다. 최종적으로 상악 총의치 및 하악 나사 유지형 지르코니아를 보철물을 제작하였으며, 만족스러운 기능 및 심미 회복을 보였기에 보고하는 바이다.

시멘트리스 나사 유지형 임플란트 시스템을 이용한 보철물 수복 증례 (Prosthetic restorations with cementless screw-retained implant systems: a case report)

  • 정영해;김임선
    • 대한치과기공학회지
    • /
    • 제45권4호
    • /
    • pp.124-130
    • /
    • 2023
  • This study aims to describe the clinical experience of single and bridge crowns fabricated using a cementless screw-retained implant prosthesis system. In the case of single crown (#37), regular link (HDL) was used, and bridge crowns (#15~#24), (#26~#27), (#17~#14) (#24~#26) were fabricated by selecting regular link and short link considering the vertical height. One abutment was hex shaped to ensure that it could be mounted while preventing insertion and prosthesis rotation. The advantages of cementless implant prosthesis include shorter chair time and periodic care, strong retention with LINK abutment, safety from inflammation, bacterial infection, and complications due to peri-implant cement, and high patient satisfaction. Dentists should double-check the position of the implant fixture and dental technicians should continuously manage the fit of the link and prosthesis with digital equipment to reduce screw loosening and fractures.

20년전 악교정수술을 받았던 환자의 심한 전치부 반대교합의 해결을 위한 임플란트 치료 증례 (Implant treatment on anterior cross-bite of a patient who had orthognathic surgery 20 years ago)

  • 박광만;이성복;이석원
    • 대한치과보철학회지
    • /
    • 제57권3호
    • /
    • pp.245-253
    • /
    • 2019
  • 골격성 3급 부정교합의 악교정 수술로 구강기능과 안모를 개선할 수 있다. 악골부조화가 클수록 술전 교정치료에 의한 치아 이동량이 더욱 커지기 때문에 치주조직에도 큰 변화를 줄 수 있는데, 특히 하악 전치부 치주조직의 파괴가 주로 발생된다. 이 보고는 20년전 골격성 3급 부정교합과 하악전돌로 악교정수술을 받은 후 하악 전치부의 심한 동요 및 반대교합의 해결을 위해 내원한 49세 여성환자의 증례로, Face Hunter, Plane System 및 ARCUS digma II를 이용하여 Top-Down concept의 개인 맞춤형 분석으로 치료계획을 수립하였다. 하악 전치부 발치를 동반한 순측 치조골 성형술과 임플란트 식립 후 즉시임시치관에 의한 즉시부하를 시행하였다. 최종 보철물은 CAD/CAM에 의한 Zirconia 수복물로 제작 후 구강 내에서 나사유지형으로 장착하였다. 6개월이 경과한 현재까지 보철물의 파절과 동요 등은 관찰되지 않았으며, 기능 및 심미적으로 만족스러운 결과를 얻었기에 보고하고자 한다.

임플란트 고정체-지대주 연결부 및 지대주 디자인이 기계적 강도에 미치는 영향 (Influence of Implant Fixture-Abutment Connection and Abutment Design on Mechanical Strength)

  • 전미현;정창모;전영찬;엄태관;윤지훈
    • 구강회복응용과학지
    • /
    • 제24권3호
    • /
    • pp.269-281
    • /
    • 2008
  • 골유착성 임플란트 보철물에서 피로나 과하중에 의해 보철유지 나사나 지대주 나사의 파절, 보철물의 파절, 또는 고정체의 파절 등과 같은 기계적 강도와 연관된 문제점이 발생할 가능성이 높다. 임플란트 시스템의 기계적인 강도에 영향을 주는 요소에는 고정체와 나사의 직경, 재료적 특성, 연결부 디자인, 지대주 디자인 등이 있으며, 이 중 임플란트 고정체와 지대주간의 연결부 디자인은 임플란트 시스템의 기계적인 연결상태와 연결부 안정성을 결정하는 주요소이다. 대부분의 기계적 강도에 관한 연구에서처럼 단일하중에 의한 압축굽힘강도나, 단기적인 반복하중 후의 결과만을 평가하여 임플란트 시스템의 장기적인 안정성을 예측하기에는 한계가 있다. 연구 목적: 이에 본 연구에서는 external butt joint와 internal conical joint를 갖는 임플란트 시스템(오스템사)의 연결부 디자인에서 각각 다른 두 가지 지대주를 사용하여, 연결부 및 지대주 디자인이 기계적 강도에 미치는 영향을 압축굽힘강도는 물론 내구성한계를 측정하여 알아보고자 하였다. 연구 재료 및 방법: External butt joint인 US II에서는 통상적인 UCLA 지대주 형태의 Cemented abutment(BJT)와 굽힘 저항성을 증가시키기 위해 나사 두부가 지대주 상단에 위치하도록 설계된 Safe abutment(BJS)를, internal conical joint인 SS II에서는 one-piece형의 Solid abutment(CJO)와 two-piece형의 ComOcta abutment(CJT)를 지대주로 사용하였다. ISO 규정을 참고하여 단일 임플란트, 변연골 흡수, 그리고 $30^{\circ}$ 경사하중 조건에서 압축굽힘강도와 내구성한계를 측정하였고 실패 양상을 관찰한 결과 다음과 같은 결론을 얻었다. 결과 및 결론: 1. 압축굽힘강도는 BJS군(1392.0N), CJO군(1261.8N), BJT군(1153.2N), 그리고 CJT군(1110.2N) 순으로 낮아졌으며(P<.05), CJT군과 BJT군 사이에는 차이가 없었다(P>.05) 2. 내구성한계는 CJO군(600N), CJT군(453N), BJS군(360N) 그리고 BJT군(300N) 순으로 낮아졌다. 3. 압축굽힘강도는 연결부 디자인 또는 지대주 디자인에 따라 차이를 보였으며, 내구성한계에 있어서는 연결부 디자인이 더 주된 요소로 작용하였다.