• Title/Summary/Keyword: 나사못 고정술

Search Result 65, Processing Time 0.02 seconds

Surgical Experience with Posterior Atlantoaxial Transarticular Screw Fixation in Atlantoaxial Instability (환추-축추 불안정성에 있어서 후방 경관절 나사못 고정술에 대한 수술적 경험)

  • Cha, Seung Kyu;You, Chan Jong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.95-100
    • /
    • 2000
  • Objective : Posterior transarticular screw fixation is known to be one of the best surgical method for the atlantoaxial instability. We assessed the complication and operative risk in 15 patients. Patients and Methods : Between January 1997 and April 1998, 15 patients suffering from this condition were admitted to our institution. Atlantoaxial instability was caused by C1 or C2 fractures in 11, rheumatoid arthritis in 2, and os odontoideum in 2. This technique was used in the treatment of 13 patients and 2 patients was used in sublaminar wire fixation only. Bilateral C1-C2 screws were placed in 11 patients ; 2 patients had only one screw placed becauce of an anomalous vertebral artery and axial destruction. Follow-up period ranged from 5 to 20 months. Results : Most screws were positioned satisfactorily. One screw was malpositioned. No patients had neurological complications. Conclusion : Rigidly fixating C1-C2 instability with transarticular screws showed a significantly higher fusion rate than that achieved using wired grafts alone. The risk of screw malpositioning and catastrophic vascular or neural injury is small and can be minimized by assessing the position of the transverse foramen on preoperative computed tomographic scans and by correctly using intraoperative fluoroscopy and surgeon's precaution.

  • PDF

Coracoclavicular Screw Fixation for AC Dislocation and Unstable Distal Clavicle Fracture (견봉 쇄골 탈구와 쇄골 외측단 골절에서 일시적 오구 쇄골간 나사못 고정술)

  • Kim Jin Sub;Jun Jin Ho;Chung Yung Khee
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.133-137
    • /
    • 1999
  • Purpose: There are so many different methods with the their own advantages and disadvantages for acute AC dislocation and distal unstable clavicle fracture. We evaluated the usefulness of temporary Bosworth's coracoclavicular fixations using the cannulated screw and reviewed our clinical results. Materials and Methods: We evaluated 34 cases of temporary coracoclavicular fixations with cannulated screw and washer for acute AC dislocation(25cases in the Type V, Ⅲ) and distal unstable clavicle fracture(9cases in the Type ⅡB, Ⅱ+Ⅲ). All cases were fixed by the same techniques, guided cannulated screw under C-arm after the repair of the CC ligament within 1 week. Bases on the regular check, screws were removed at the 6-12 weeks under local anesthesia. The final clinical and radiological results(average 14 months follow-up) were rated with the UCLA scale. Results : All shoulders were gained nearly full ROM passively at the 3-4 weeks. The overall satisfactory resuIts(excellent or good) were achieved 88%(22/25) in the acute AC dislocation and all in the distal unstable clavicle fracture. There were no definite complications except three initial fixations loosening. Conclusion: Temporary Bosworth's coracoclavicular fixation using the cannulated screw with guided pin was simple precedure and provided enough initial stability for acute AC dislocation and distal unstable clavicle fracture.

  • PDF

Surgical Results of Patients with Isthmic Spondylolisthesis with Transpedicular Screw Fixation and Posterior Lumbar Interbody Fusion Using Posterior Movable Segment (협부형 척추전방전위증에 대한 후방가동관절 이용한 골유합술 및 척추경나사못 고정술의 수술적 결과)

  • Kim, Chan;Lee, Seung Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.108-114
    • /
    • 2001
  • Objective : Posterior lumbar interbody fusion(PLIF) provides the favorable outcome to degenerative lumbar disease, especially isthmic spondylolisthesis. To determine the long-term effect of PLIF using psterior movable segment, we analysed the results of follow-up radiologic changes and surgical outcome retrospectively Patients and Method : During the past 11 years(1989. 1.-1999. 9.), 148 patients with symptomatic lumbar spondylolisthesis were managed at our department and the clinical wants were throughly recieved and final outcome is determined at last follow up. PLIF using antogenous bone(posterior movable segment, iliac bone and rib) were performed in 106 case. Results : After an average follow-up period of 33 months(range ; 15-58 months), the results were excellent in 66 cases, good in 37 cases, fair in 2 cases and poor in 1 cases. And the satisfactory results were 103 cases(98.2%) in PLIF,. Conclusion : In conclusion, patients who underwent PLIF with autologous bone graft had good clinical and radiological outcomes without significant neurological complications.

  • PDF

Short Segment Pedicle Screw Fixation with Augmented Intra-Operative Vertebroplasty in Unstable Thoraco-Lumbar Fracture - Preliminary Report - (불안정성 흉·요추부 골절에 대한 단 분절 척추경 나사못 고정술 및 추체 보강 성형술 - 예 비 보 고 -)

  • Kim, Young Woo;Oh, Sung Han;Yoon, Do Heum;Chin, Dong Kyu;Cho, Yong Eun;Kim, Young Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.11
    • /
    • pp.1271-1277
    • /
    • 2001
  • Objectives : Since vertebroplasty has been introduced, we performed short segment pedicle screw fixation with augmented intra-operative vertebroplasty in patients with unstable thoraco-lumbar fracture. Our intentions are to demonstrate the efficacy and indication of this new technique compare to conventional methods. Material and Methods : The surgery comprised of pedicle screw fixations on one level above and below the fracture site, and the fractured level itself, if pedicle is intact, and intra-operative vertebroplasty under the fluoroscopic guide with in-situ postero-lateral bone graft. Also, in cases of bone apposition, we removed those with small impactor through a transfascetal route. During the last 2 years, we performed in seven(7) unstable thoraco-lumbar fracture patients who consisted of two different characteristics, those four(4) with primary or secondary osteoporosis and three(3) of young and very healthy. All patients were followed clinically by A.S.I.A. score and radiography. Results : Mean follow up period was 14 months. We observed well decompressed state via transfascetal route in cases of bone fragments apposition and no hardware pullout in osteoporotic cases, no poly-methyl-methacrylate (PMMA) leakage through the fracture sites into the spinal canal, and no kyphotic deformities in both cases during follow-up periods. All patients demonstrated solid bony fusion except one following osteoporotic compression fracture on other sites. Conclusions : In the management of unstable thoraco-lumbar fracture, we believe that this short segment pedicle screw fixation with augmented intra-operative vertebroplasty reduce the total length or levels of pedicle screw fixation without post-operative kyphotic deformity.

  • PDF

Clinical results of arthroscopic tenodesis of the proximal biceps tendon using by interference screw (관절경적 상완 이두근 건고정술의 임상적결과)

  • Kweon, Seok-Hyun;Chun, Churl Hong;Choi, Yoon Hong;Han, Sang Su;Kim, Jeong Woo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.24-29
    • /
    • 2012
  • Purpose: To evaluate follow-up after the clinical results of arthroscopic assisted tenodesis of the proximal biceps tendon using an interference screw. Materials and Methods: We reviewed 30 cases of patients receiving tenodesis of the proximal biceps tendon between January, 2008 and January, 2010 who treated with arthroscope. The results were judged by VAS, ASES, tenderness in the biceps groove, fixation failure and the degree of deformity. Results: VAS, ASES scores increased by a statistically significant during the final observation in all patients than before surgery (p<0.05). For those with rotator cuff tear had low ASES results (p<0.05), respectively. But, tenderness in the biceps groove was 17% (5 cases), pepeye deformity and incresead BAD (biceps apex distance) were 10% (3 cases). Conclusion: Arthroscopic tenodesis of the proximal biceps tendon using an interference screw to patients with proximal lesion in their biceps tendon, can achieve good results, but it is possible to groove tenderness and popeye deformity.

  • PDF

The Surgical Treatment of Chronic Avulsion Fracture of the Anterior Cruciate Ligament (진구성 전방 십자 인대 견열 골절의 수술적 치료)

  • Song Eun-Kyoo;Seol Jong-Yoon;Choi Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.1
    • /
    • pp.31-36
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the clinical and radiological results after treatment of old ACL(anterior cruciate ligament) avulsion fracture of tibia. Materials and Method : 11 cases who were followed up at least 2 years after treatment in chronic ACL avulsion fracture of tibia were included in this study. The average age of patients was 26(9-66) years and the mean period of follow up was 53(24-131) months. After evaluation of the lesion and treatment of associated lesion under arthroscope, open reduction and internal fixation or fragment removal was performed. Pull-out suture was performed in 8 cases, screw fixation in 2 cases. Results : The Lysholm knee score was 64.3 in average preoperatively and improved to 96.2 average at follow up. On the Lachman test, there were mild(+) instabilities in 7 cases, moderate(++) in 4 cases. On the postoperative Lachman test, there were no instabilities in 9 cases, mild(+) instabilities in only 2 cases. According to Meyers and Mckeever's evaluation protocol, 9 cases $(81.8\%)$ were excellent, 2 case $(18.2\%)$, good. On preoperative instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference in 201b was 7.8(10-4) min in average and 2.1(6-0) mm in average at follow-up. Conclusion : In chronic ACL avulsion fracture, it is thought that combination of arthroscopic evaluation of associated injury and open reduction and fixation and fragment removal can bring about satisfactory results.

  • PDF

Internal Fixation of Proximal Humerus Fracture with Locking Compression Plate (잠김 압박 금속판을 이용한 근위 상완골 골절의 내고정술)

  • Park, Chul-Hyun;Park, Sung-Hyuk;Seo, Jae-Sung
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.44-52
    • /
    • 2009
  • Purpose: We assessed the radiographic and clinical results of one surgeon's experience treating proximal humerus fractures with a locked proximal humeral plate. Materials and Methods: Twenty patients with unstable proximal humerus fractures were treated with a locking compression plate between February 2005 and September 2007. The average age of the patients was 60.6 years, and the average postoperative follow-up period was 22.3 months. The clinical results were evaluated using the Constant and DASH scores. The radiologic results were evaluated by the Paavolainen method, which measures the neck shaft angle and humeral head height. Results: At the last follow-up examination, the mean Constant score was 75.3 and 15 cases (75%) had excellent or good results; the mean DASH score was 16.4. The mean neck shaft angle was $137.1^{\circ}$, and 19 cases (95%) had good results by the Paavolainen method. There was one delayed union, malunion, and screw loosening. Conclusion: The patients treated with a locking compression plate had relatively good clinical and radiologic results, and a low complication rate. Moreover, the patients could exercise earlier due to good reduction and initial stability. Treatment of unstable proximal humerus fractures with a locking compression plate is a reliable method.

Reconstruction of Anterior Cruciate Ligament With Bone-Patellar tendon-Bone Allograft (동종 슬개건을 이용한 전방십자인대 재건술)

  • Chun, Churl Hong;Lee, Byoung Chang;Kim, Young Jin;Yang, Hwan Duk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.102-108
    • /
    • 1999
  • Purpose : The purpose of this study was to evaluate the clinical results of bone-patellar tendon-bone(B-PTB) allograft for ACL reconstruction without mechanical tensioning device. Material and Method : Forty-six knees in 43 patients were reviewed and evaluated with subjective evaluation, objective evaluation, Telos stress arthrometer and modified Feagin Scoring System. The average age at the time of operation was 27 years(range, 18-42) and the average follow up period was 41 months(range, 22-79). Authors reconstructed ACL using B-PTB allograft which was prepared by rehydration preoperatively without tensioning by mechanical tensioning device. The tension for allograft was obtained by full flexion and extension intraoperatively. All operation were performed arthroscopically by two-tunnel method to avoid the mismatching of allograft tendon length. Result : The modified Feagin Scoring System revealed 39 cases(84.7%) with excellent or good results and 7 cases(15.3%) with fair or poor results. The mean follow-up Lysholm Knee Score was 84. Telos arthrometer revealed 41 cases had an injured-to-uninjured difference of 5 mm or less(mean 2.3mm). The range of motion of knee was nearly normal and there was no extension lag in any cases at last follow up. Conclusion : Clinical results using B-PTB allograft showed less morbidity than B-PTB autograft. The intraoperative tensioning method by full flexion and extension without mechanical tensioning device was not bad. Therefore, B-PTB allograft is a good substitute material in reconstruction of the ACL.

  • PDF

Comparison of Results of ACL Reconstruction According to the Fixation Materials (Metal & Bioabsorbable Interference Screw and RIGIDfix) (금속, 흡수성 간섭 나사못 및 RIGIDfix를 이용한 전방 십자 인대 재건술의 결과 비교)

  • Lim Hong Chul;Wang Joon Ho;Rho Young Jin;Hwang Jin Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.206-214
    • /
    • 2003
  • Purpose : To analysis each clinical results after arthroscopic ACL reconstruction with using variable fixatives which are metallic and bioabsorbable interference screw, and RIGIDfix. Therefore, We reported the clinical reliability and safty of ACL reconstruction using RIGIDfix. Materials and Methods : We evaluated the results of arthroscopic ACL resconstruction with patellar tendon autograft among three groups, of which group 1 is used metal interference screw for 44 patients, group 2 used bioabsorbable interference screw for 47 patients, group 3 used RIGIDfix for 42 patients. We compared the clinical results by physical examination (anterior drawer test, Lachman test and pivot shift test), Lysholm score and KT-2000 arthrometer and compared the radiological results by measurement of tunnel and fixatives position and widening and by MRI findings. We analyzed the results by SAS 8.2 Ducan. Tukey and paired t-test Results : Physical instability was in 5 cases, which group 2 had 4 cases and group 3 had 1 case. Lysholm score improved from 59.8. 64.4, 61 to 90.1, 92.3. 92. KT-2000 arthrometer instability improved from 9.20, 10.2, 9.5 to 1.43. 1.62. 2.00 (p=0.478). Radiologically, all cases had excellent tunnel position and cyst change was observed the 8 cases in the group 2, but, all 20 cases 2nd MRI had signal change of peri-fixatives. But, no correlation of clinical results. Conclusion : No statistical difference of clinical instability was found among three groups. And femoral tunnel changes were much observed in group I, II than III. We considered the RIGIDfix has much advantages because the short operation time, better fixation position and much bone contact surface. But, further long term follow up study was needed.

  • PDF

Bioabsorbable Screws Used in Hallux Valgus Treatment Using Proximal Chevron Osteotomy (무지외반증 환자의 근위 갈매기형 절골술에서 생체 흡수성 나사못을 이용한 고정)

  • Shin, Woo-Jin;Chung, Young-Woo;An, Ki-Yong;Seo, Jae-Woong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.4
    • /
    • pp.181-183
    • /
    • 2018
  • Hallux valgus is a deformity that causes pain in the first metatarsophalangeal joint. Surgical methods are quite diverse and a range of osteotomies are used at the proximal and distal part of the metatarsal bone and proximal phalange. Fixation methods, such as plate, screw, K-wire, and others have been used in various ways. The fixation device is often removed with various side effects due to the fixation devices. In the case of instruments that are absorbed in vivo, these procedures are not necessary to remove and there is an advantage of not performing the second operation. Three patients were treated, in which a proximal chevron osteotomy was used with a bioabsorbable screw (K-$MET^{TM}$; U&I Corporation).