• Title/Summary/Keyword: 기.액접촉비

Search Result 18, Processing Time 0.023 seconds

Preparation of PVDF Hollow Fiber Membrane and Absorption of SO2 from Flue Gas Using Bench Scale Gas-Liquid Contactor (PVDF 중공사막 제조 및 벤치규모 기-액 접촉기를 이용한 SO2 흡수특성)

  • Park, Hyun-Hee;Jo, Hang-Dae;Kim, In-Won;Lee, Hyung-Keun
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.521-528
    • /
    • 2008
  • The micro-porous asymmetric PVDF hollow fiber membranes for gas-liquid contactor were prepared by the dry-jet wet phase inversion process and the characteristics of hollow fiber membranes were evaluated by the gas permeation method and scanning electron microscope. The chemical absorbent for removal of $SO_2$ gas was sodium hydroxide at bench scale hollow fiber membrane contactor. The experiments were performed in a counter-current mode of operation with gas in the shell side and liquid in the fiber lumen of the module to examine the effect of various operating variables such as concentration of absorbent, gas flow rate, L/G ratio and concentration of inlet $SO_2$ gas on the $SO_2$ removal efficiency using PVDF hollow fiber membrane contactor. Membrane mass transfer coefficient($k_m$) was calculated by mathematical modeling. The volumetric overall mass transfer coefficient increased with increasing the concentration of absorbent and L/G ratio. The increase of the absorbent concentration and L/G ratio not only provides more sufficient alkalinity but also decreases liquid phase resistance. The volumetric overall mass transfer coefficient increased with increasing gas flow rate due to decreasing the gas phase resistance.

The Fixation Effects of Biological specimen Using Microwave Oven Equipped With Infrared-Temperature Sensor (적외선 온도감응기를 장착한 마이크로파 오븐의 생체물질 고정효과)

  • 신길상
    • The Korean Journal of Zoology
    • /
    • v.37 no.2
    • /
    • pp.144-155
    • /
    • 1994
  • 마이크로파 에너지로서 현미경 관찰을 위한 생체물질을 고정할 때, 고정효과는 화학 고정액을 사용할 때와 비교하여 보다 우수한 또는 적어도 동일한 고정효과를 볼 수 있다는 것은 알려진 사실이다. 그러나 기존의 마이크로파 오븐을 사용하여 생체물질을 고정하면 고정 정도에 일정성이 없는데, 이는 마이크로파가 균일하게 조사되지 않고 고정에 적절하도록 마이크로팍의 강도를 조절하기 어려우며, 이로 인하여 정확한 고정온도의 측정이 불가능하기 때문으로 생각된다. 이 연구에서는 마이크로파가 조사되는 동안 시료의 온도를 측정할 수 없는 기존의 마이크연.파 오븐의 단점을 보완하기 위하여 비접촉식 적외선 온도 감응기를 장착한 마이크로파 오븐을 개발하였으며 고정효과를 관찰하기 위하여는 포유류의 기준 조직으로 알려진 생쥐의 신장을 고정하였다 고정효과는 전체적인 구조와 세부 구조의 보존이 모두 우수하였고 최적의 고정온도는 28$\pm$1$^{\circ}C$(완충용액 20 ml, 10초) 이었다. 이와같이 고정된 재료는 고정효과 뿐만 아니라 염색성이 좋아서 조직화학 반응이 우수하고, 냉동절편법과 연계했을 때 전체 절편제작 과정이 2~4시간 내에 완료될 수 있었다 이때 절편의 질(질)은 화학 고정액이나 냉동절편 법에 의하여 제작된 것 보다 우수하였다.

  • PDF

Study of Separation of carbon dioxide through hollow fiber membrane contactor (중공사막 접촉장치를 통한 이산화탄소 분리에 관한 연구)

  • 염봉열;김민수;이용택;박유인;이규호
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.61-64
    • /
    • 1997
  • 1. 서론 : 적절한 이산화탄소의 분리는 지구온난화의 가속현상을 늦출 수 있을 뿐만 아니라 각종 탄화수소가스의 원료로 분리 정제된 이산화탄소를 재이용할 수 있으므로 경제적으로 매우 중요하다. 이산화탄소 분리에 사용되던 기존 공정들의 단점을 보완할 수 있는 대체방안으로 최근에 개발되기 시작한 것이 소수성의 다공성 고분자 분리막(hydrophobic porous ploymeric membrane) 방법인데, 이는 모듈의 유효 막 표면적이 상대적으로 크고 기체와 액체의 흐름을 독립적으로 제어할 수 있으므로 범람 등의 현상이 없으나 막 자체의 저항이 비교적 큰 단점을 가지고 있다. Qi와 Cussler는 이러한 특성을 가지는 중공사막 모듈에서의 기-액 흐름에 대한 물질전달 상관관계식을 얻었으며[1], Karoor 등은 여러 가지 중공사막 모듈을 사용하여 순수물과 diethanolamine(DEA) 등의 흡수제에 대한 이산화탄소의 물질전달 거동을 수치모델과 실험을 통하여 고찰하였다[3]. 또한 중공사막 접촉기의 실제적 응용에 대하여 Matsumoto 등은 화력발전소에서 발생하는 연소가스 내의 이산화탄소 흠수에 대한 연구를 수행하였다[4]. 본 연구에서는 중공사막 접촉장치를 사용하여 흡수제를 순수물과 탄산칼륨($K_2CO_3$)을 사용했을 경우의 이산화탄소의 분리 거동을 수치모델과 실험을 통하여 고찰하였다. 수치모델의 경우 이전까지의 연구가 반응이 없는 경우나 반응식을 간략화시킨 경우에 한정되었는데 비하여, 반으이 있는 경우 각각의 반응물질들의 거동을 고려한 반응식을 유도하여 해를 구하고자 하녔다.

  • PDF

A Study on the Mass Transfer of Extraction Process by Use of Hollow Fiber Membrane Module (실관막 모듈을 이용한 추출공정의 물질전달에 관한 연구)

  • Kim, Young-Il;Jin, Do-Won;Kim, Jong-Hyun;Choi, Dai-Ung;Park, Dong-Won
    • Applied Chemistry for Engineering
    • /
    • v.7 no.5
    • /
    • pp.977-984
    • /
    • 1996
  • Liquid-liquid extractions by use of hollow fiber membrane module are fast because of the large surface area per volume. In these membranes, the extractant and feed can be contacted at high speed and two flows are completely independent, so there are no problems with loading and channeling. In this paper, it was investigated the selectivities of extractants for extraction of heavy metals from aqueous solution into organic extractants by using the hollow fiber membrane. To identify the effect of distribution ratio on mass transfer in the membrane, we also compared the distribution ratio with mass transfer coefficient. From these experiments for the system with high distribution ratio, effect of the distribution ratio on mass transfer was weak compare with the low distribution ratio system in the hollow fiber membrane.

  • PDF

Preparation and Properties of Polydimethylsiloxane Modified Urea with Multi Acrylate Group Coating Materials (Multi Acrylate기를 갖는 Polydimethylsiloxane 변성 Urea 코팅 액의 제조와 그 특성)

  • Bak, Seung Woo;Kang, Ho-Jong;Kang, Doo Whan
    • Polymer(Korea)
    • /
    • v.38 no.6
    • /
    • pp.720-725
    • /
    • 2014
  • Aminopropyl terminated polydimethylsiloxane was synthesized by hydrosilylation reaction with hydride terminated polydimethlysiloxane and allyl amine. Polydimethylsiloxane modified urea with isocyanate group was prepared from cyclic trimer of hexamethyldiisocyanate with aminopropyl terminated polydimethylsiloxane. Polydimethylsiloxane modified urea/acrylate resin (PUA) was prepared from the urethane reaction of PU with isocyanate group and 2-hydroxyethylmethacrylate. PUA structure was analyzed by FTIR and NMR. Coating materials were prepared by mixing PUA, acrylic monomer, photo-initiator, and solvent and coated on PET film to obtain flexible hard coating film by UV irradiation.

Study on Micro-bubble Generation Characteristics in Venturi Cavitation using Laser Diffractometer (레이저 회절 측정기를 이용한 벤츄리 캐비테이션에서의 마이크로버블 발생 특성 연구)

  • Lim, Yun Gyu;Yang, Hae Jeong;Kim, Yung Il
    • Journal of Drive and Control
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • The use of micro bubbles in industrial fields has been increasing in the recent years., particularly micro-bubble sterilization and water purification effects. Various methods have been developed for the generation of micro-bubbles. Depending on the method of generating bubbles, the micro-bubbles can be roughly classified into saturation molding, cavitation and rotation flow types. The objective of this study was to use ventilated tube type as a method of generating micro-bubbles in order to purify large amount of water quality such as lakes and reservoirs. This method shows a difference in efficiency in which micro-bubbles are generated depending on the contact ratio of gas to liquid. The study also investigated the optimal gas liquid contact ratio by applying various orifice methods and investigated the optimum condition of micro-bubble generation by gas Based on this, a technology to develop a micro-bubble generator with a venturi type nozzle shape that has a high water purification effect was developed.

Effect of proton concentration in TEOS to improve durability of hydrophilic and high light transmittance properties of nanosilica coating (친수 및 높은 광투과 기능을 함유한 나노실리카 코팅액의 내구성 향상을 위한 수소이온 농도에 따른 TEOS의 반응 연구)

  • Lee, Soo;Chan, Sung Il;Hwang, Heon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.483-491
    • /
    • 2016
  • Even though the antifogging property of nanosilica coated glass surface is highly increased due to the hydrophilic hydroxyl groups on nanosilica surface, the durability of this property on outdoor glass was diminished rapidly after rain washing. In addition the topology of nanosilica coated glass surface plays very important roles to control an light transmittance or antireflection property. To improve these coating durability and characteristics a hydrophilic nanosilica coating on glass was prepared by coating with 1.5 wt% of nanosilica (Ludox) suspension in the presence of hydrolyzed tetraethylorthosilicate (TEOS). The optimum hydrolysis condition of TEOS in acidic or basic aqueous solution was also examined by contact angle measurement. The final transparent hydrophilic coating layer coated with nanosilica-TEOS in acidic condition (pH=4) showed much improved durability of hydrophilic surface as well as higher visible light transmittance than original uncoated glass by 2 % point.

Vapor Permeation Separation of MTBE-Methanol Mixtures Using Cross-linked PVA Membranes (가교된 PVA 막을 이용한 MTBE/methanol 혼합물의 증기투과(Vapor Permeation)분리)

  • 김연국;임지원
    • Membrane Journal
    • /
    • v.10 no.3
    • /
    • pp.148-154
    • /
    • 2000
  • Poly(vinyl alcohol)(PVA)/sulfur-siccinic acid(SSA) membrane performances have been studied for the vapor permeation separation of methyl tort-butyl ether(MTBE)/methanol mixtures with varying operation temperatures, amount of cross-linking agents, and feed compositions. 1'here are two factors, the membrane network and the hydrogen bonding, in the swelling measurements of PVA/SSA membranes. These two factors act interdependently on the membrane swelling. The sulfuric acid group in SSA took an important role in the membrane performance. The cross-linking effect might be more dominant than the hydrogen bonding effect due to the sulfuric acid group at 7% SSA membrane. Hydrogen bonding effect was more important for 5% SSA membrane. In vapor permeation, density or concentration of methanol in vapor feed is lower than that of methanol in liquid feed, as a result, the hydrogen bonding portion between the solvent and the hydroxyl group in PVA is reduced in vapor permeation. In this case, the 7% SSA membrane shows the highest separation factor of 2187 with the flux of 4.84g/$m^2$hr for MTBE/methanol=80/20 mixtures at 3$0^{\circ}C$.

  • PDF

The influence of co-axial air flow on the breakup length of a smooth liquid jet (平滑流의 分裂길이에 미치는 同軸氣流의 영향)

  • 김덕줄;이충원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.6
    • /
    • pp.1390-1398
    • /
    • 1988
  • The purpose of this study was experimentally to investigate the disintegration process and disintegration mechanism when co-axial air flows vertically for the longest smooth liquid jet. These were affected by liquid velocity, air velocity, air-to-liquid diameter ratio, nozzle shape, and air-liquid contacting position. That is, this process of disintegration of the liquid jet was similar to that occurred when liquid pressure was increased. At Reynolds number of 10, 000 and below, the changes in the breakup length represent different tendency according to liquid flow rate. The influence of air flow on the disintegration of liquid jet was different according to air-to-liquid diameter ratio, air orifice diameter, nozzle shape and contacting position of liquid and air. In particular, when the tip of liquid nozzle was inside the air orifice, the effect of air flow was the larger than outside the air orifice. The effect of liquid mass flow rate on the change rate of the breakup length was also different.

Effect of the particle size on the electrical contact in selective electro-deposition of copper (구리의 선택적 전착에서 결정 입자의 크기가 전기적 접촉성에 미치는 영향)

  • Hwang, Kyu-Ho;Lee, Kyung-Il;Joo, Seung-Ki;Kang, Tak
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.1 no.2
    • /
    • pp.79-93
    • /
    • 1991
  • With the advent of ULSI, many problems in previous metallization techniques and interconnection materials have become more serious. In this work, selective deposition of copper to fill the submicron contact has been tried. After forming electro-deposited copper films on p-type (100) silicon wafer using 0.75M $CuSO_4{\cdot}$5H_2O$ as an electrolyte, the effect of deposition time, current density and concentration of an additive on film properties were investigated. Film thickness, particle size and resistivity were analyzed by Alpha Step, SEM and 4 - point probe measurement respectively. The deposition rate was about $0.5-0.6\mu\textrm{m}$/min at $2A/dm^2$ and the particle size increased with increasing current density. The resistivities of electro-deposited copper films were about $3-6{\mu}{\Omega}{\cdot}$cm for the particle size above $4000{\AA}$. By the addition of 0.2 g/l gelatin, the particle size was reduced to less than $0.1{\mu}m $ and selective plugging of copper on submicron contacts could be successfully achieved.

  • PDF