• Title/Summary/Keyword: 기포제

Search Result 277, Processing Time 0.021 seconds

Properties of Bubble According to Types and Concentrations of Concrete Foaming Agent (콘크리트용 기포제 종류 및 농도에 따른 기포의 특성)

  • Kim, Jin-Man;Kwak, Eun-Gu;Oh, Kwang-Chin;Kang, Cheol
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.2
    • /
    • pp.151-158
    • /
    • 2011
  • Bubbles within the foamed concrete manufactured by pre-foaming method is the main factor which affects the physical properties of foamed concrete such as density, strength, and porosity. Although many researches on foamed concrete have been continuously carried out, insufficient number of researches on the properties related to bubbles in the foamed concrete has been performed except for chemical application related researches. In order to make an optimal foamed concrete, study on the bubble properties must be pursued. In order to effectively implement bubbles in the manufacturing of foamed concrete, the bubble properties must be estimated. In this study, in order to determine the bubble properties, examination of the bubble properties according to types and foaming agent concentration was performed. An foaming agent used for this test were anionic surfactant, rosin, and protein system with the foaming agent concentration range of 0.05~13%. Test parameters considered in the study were foaming rate, foam volume, drainage solution volume, and bubble size. The study results showed that, regardless of foaming agent type, higher concentration of foaming agent showed an increase in the foaming rate. Also, the results showed that concentration of foaming agent affected bubble size, drainage solution volume change, and bubble distributions. With respect to the stability of the bubble, protein foaming agent was better than anion surfactant or rosin foaming agent. With respect to the bubble shape, anion surfactant and rosin formed bubbles had polygon shape where as protein formed bubbles had spherical shape.

An Experimental Study on the Pore Structure and Thermal Properties of Lightweight Foamed Concrete by Foaming Agent Type (기포제 종류에 따른 경량기포콘크리트의 기포구조 및 열적특성에 관한 실험적 연구)

  • Kim, Jin-Man;Choi, Hun-Gug;Park, Sun-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.63-73
    • /
    • 2009
  • Recently, the use of lightweight panels in building structures has been increasing. Of the various lightweight panel types, styrofoam sandwich panels are inexpensive and are excellent in terms of their insulation capacity and their constructability. However, sandwich panels that include organic material are quite vulnerable to fire, and thus can numerous casualties in the event of a fire due to the lack of time to vacate and their emission of poisonous gas. On the other hand, lightweight foamed concrete is excellent, both in terms of its insulation ability and its fire resistance, due to its Inner pores. The properties of lightweight concrete is influenced by foaming agent type. Accordingly, this study investigates the insulation properties by foaming agent type, to evaluate the possibility of using light-weight foamed concrete instead of styrene foam. Our research found thatnon-heating zone temperature of lightweight foamed concrete using AP (Aluminum Powder) and FP (animal protein foaming agent) are lower than that of light-weight foamed concrete using AES (alkyl ether lactic acid ester). Lightweight foamed concrete using AES and FP satisfied fire performance requirements of two hours at a foam ratio 50, 100. Lightweight foamed concrete using AP satisfied fire performance requirements of two hours at AP ratio 0.1, 0.15. The insulation properties were better in closed pore foamed concrete by made AP, FP than with open pore foamed concrete made using AES.

Studies on the Production and Property of Light Weight Concrete (경량(輕量)콘크리트의 제조(製造)와 그 성질(性質)에 관(關)한 연구(硏究))

  • Kim, Seong Wan;Kang, Sin Up;Cho, Seong Seup;Sung, Chan Yong
    • Korean Journal of Agricultural Science
    • /
    • v.10 no.2
    • /
    • pp.310-323
    • /
    • 1983
  • To study the effect of foaming agent on the production and property of light weight concrete, the tests of compressive, tensile, bending strengths and absorption rates of mortar were done under the different mixing ratio with J, A and D foaming agents. The results obtained were summarized as follows : 1. The strengths were decreased in richer mixing ratio and more addition of foaming agent. The decrease of strengths was the greatest at the level of 0.75% of foaming agent. The decreasing rate of strengths was in order of J, A and D foaming agent. 2. At the mixing ratio of 1:1, ${\sigma}_{28}$ and 0.75% of foaming agent, the compressive strength was decreased up to 34.9% by D, 47.8% by A and 86.8% by J foaming agent, respectively, the tensile strength was decreased up to 14.8% by D, 20.2% by A and 77.9% by J foaming agent, respectively, bending strength was decreased up to 19.9% by D, 35.0% by A and 79.1% by J foaming agent, respectively. The decrease of compressive strength was more severe than that of tensile and bending strengths. 3. The absorption rates were increased in poorer mixing ratio and more addition of foaming agent. The absorption rate was significantly higher at the early stage of immersed water. The absorption rate was in order of J, A and D foaming agent. 4. The decrease of strengths was inevitable in cement-mortar with foaming agent, but the cement mortar with foaming agent has such the properties of the light-weight, lnsulation, Keeping-warmth, sound proof and fire-proof that if could be utilized to the constructions which need low strengths.

  • PDF

Properties of Foamed Concrete According to Types and Concentrations of Foam Agent (기포제 종류 및 희석 농도에 따른 기포 콘크리트의 특성)

  • Kim, Jin-Man;Jeong, Ji-Yong;Hwang, Eui-Hwan;Shin, Sang-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.1
    • /
    • pp.61-70
    • /
    • 2012
  • Recently, the government has been working feverously to save energy and reduce greenhouse gas emission by enacting Basic Act on Low Carbon Green Growth at the national level. Improving the insulation performance of building exterior and insulator can reduce the energy in the building sector. This study is about developing light-weight foamed concrete insulation panel that can be applied to buildings to save energy and to find the optimal condition for the development of insulation materials that can save energy by enhancing its physical, kinetic and thermal characteristics. Various experimental factors and conditions were considered in the study such as foam agent types (AES=Alcohol Ethoxy Sulfate, AOS=Alpha-Olefin Sulfonate, VS=Vegetable Soap, FP=Fe-Protein), foam agent dilution concentration (1, 3, 5%), and foam percentage (30, 50, 70%). Experiment results indicated that the surface tension of aqueous solution including foam agent, was lower when AOS was used over other foam agents. FP produced relatively stable foams in 3% or more, which produced unstable foams containing high water content and low surface tension when diluted at low concentration. Depending on foam agent types, compressive strength and thermal conductivity were similar at low density range but showed some differences at high concentration range. In addition, when concentrations of foam agent and foaming ratio increased, pore size increased and open pores are formed. In all types of foam agent, thermal conductivity were excellent, satisfying KS standards. The most outstanding performance for insulation panel was obtained when FP 3% was used.

A Study on the Characteristics of Mortar Using Foaming Agents (기포제(起泡劑)를 사용(使用)한 모르터의 제특성(諸特性)에 관(關)한 연구(硏究))

  • Sung, Chan Yong
    • Korean Journal of Agricultural Science
    • /
    • v.15 no.1
    • /
    • pp.82-94
    • /
    • 1988
  • This study was performed to obtain the basic data which can be applied to use of foaming mortars. The results obtained were summarized as follows ; 1. The lowest water-cement ratios were shown at the mixing ratio of 1 : 1. But, it was gradually increased in poorer mixing ratio and decreased in more addition of foaming agent. The water-cement ratios were decreased up to 1.6-53.1% by mix-foaming type and 4.4-24.1% by pre-foamed type than cement mortar. 2. The highest bulk densities were shown at the mixing ratio of 1 : 1. But, it was gradually decreased in poorer mixing ratio and more addition of foaming agent. The decreasing rates of bulk densities were increased in richer mixing ratio and more addition of foaming agent. 3. The bulk densities were decreased up to 38.8-55.9% by mix-foaming type and 9.7-23.6% by pre-foamed type than cement mortar. 4. The lowest absorption rates were shown at the mixing ratio of 1 : 1. But, it was gradually increased in poorer mixing ratio and more addition of foaming agent. The increasing rates of absorption rates were increased in richer mixing ratio and more addition of foaming agent. 5. Absorption rates when immersed in 72hours were shown up to 3.41-5.85 times greater by mix-foaming type and 1.05-1.55 times greater by pre-foamed type than those of cement mortar. it was significantly higher at the early stage of immersed time than cement mortar. 6. The highest strengths were shown at the mixing ratio of 1 : 1. But, it was gradually decreased in poorer mixing ratio and more addition of foaming agent. The decreasing rates of strengths were increased in poorer mixing ratio and more addition of foaming agent. 7. The strengths were decreased up to 77.0-92.8% by mix-foaming type and 36.7-74.4% by pre-foamed type than cement mortar. 8. The lowest air contents were shown at the mixing ratio of 1 : 1. But, it was gradually increased in poorer mixing ratio and more addition of foaming agent. The increasing rates of air contents were increased in richer mixing ratio and more addition of foaming agent. 9. Air contents were shown up to 26.0-63.8 times greater by mix-foaming type and 5.8-17.7 times greater by pre-foamed type than those of cement mortar. 10. The correlations between bulk density, absorption rate, compressive strength and air content were highly significant. The multiple regression equations of bulk density, absorption rate, compressive strength, tensile strength, bending strength and air content were computed depending on a function of mixing ratio and addition of foaming agent. They were generally highly significant.

  • PDF

Effects of Foaming Agent on the Characteristic of Mortar (기포제(起泡劑)가 모르터의 특성(特性)에 미치는 영향(影響))

  • Kim, Seong Wan;Kang, Sin Up;Cho, Seong Seup;Sung, Chan Yong
    • Korean Journal of Agricultural Science
    • /
    • v.11 no.1
    • /
    • pp.133-145
    • /
    • 1984
  • To study the effect of foaming agent on the characteristic of mortar, the tests of water-cement ratio and bulk density of mortar were done under the different mixing ratio with G. U and J foaming agents. The results obtained were summarized as follows: 1. At the mixing ratio of 1 : 4 and 0.5% of foaming agent, the highest water-cement ratio was 90% by G, 88.3% by U and 70% by J foaming agent, respectively, being lower than 91.6% of that of cement mortar. 2. At the mixing ratio of 1 : 3 and 3.0% of foaming agent, the water-cement ratio was decreased up to 22.0% by G and 24.1% by U foaming agent, respectively, but it gradually was increased in richer and poorer mixing ratio. At the mixing ratio of 1 : 4 and 3.0% of foaming agent, the water-cement ratio was decreased up to 53.1% by J foaming agent, but it gradually was increased in richer mixing ratio. 3. At the mixing ratio of 1 : 1 and 0.5% of foaming agent, the highest bulk density was $1.981g/cm^3$ by G, $1.863g/cm^3$ by U and $1.149g/cm^3$ by J foaming agent, respectively, being lower than $2.048g/cm^3$ of that of cement mortar. 4. At the mixing ratio of 1 : 2 and 3.0% of foaming agent, the bulk density was decreased up to 20.7% by G, 23.7% by U and 56.5% by J foaming agent, respectively, but it gradually was increased in richer and poorer mixing ratio. 5. The water-cement ratio and bulk density were decreased in more addition of foaming agent, respectively, multiple regression equations of water-cement ratio and bulk density were computed depending on a function of mixing ratios and addition of foaming agents.

  • PDF

Measurement of Bubble Size in Flotation Column using Image Analysis System (이미지 분석시스템을 이용한 부선컬럼에서 기포크기의 측정)

  • An, Ki-Seon;Jeon, Ho-Seok;Park, Chul-Hyun
    • Resources Recycling
    • /
    • v.29 no.6
    • /
    • pp.104-113
    • /
    • 2020
  • Bubble size in froth flotation has long been recognized as a key factor which affects the bubble residence time, the bubble surface area flux (Sb) and the carrying rate (Cr). This paper presents method of bubble size measurement, relationship between operating variables and gas dispersion properties in flotation column. Using high speed camera and image analysis system, bubble size has been directly measured as a function of operating parameters (e.g., superficial gas rate (Jg), superficial wash water rate (Jw), frother concentration) in flotation column. Relationship compared to measured and estimated bubble size was obtained within error ranges of ±15~20% and mean bubble size was 0.718mm. From this system the empirical relationship to control the bubble size and distribution has been developed under operating conditions such as Jg of 0.65~1.3cm/s, Jw of 0.13~0.52cm/s and frother concentration of 60~200ppm. Surface tension and bubble size decreased as frother concentration increased. It seemed that critical coalescence concentration (CCC) of bubbles was 200ppm so that surface tension was the lowest (49.24mN/m) at frother concentration of 200ppm. Bubble size tend to increase when superficial gas rate (Jg) decreases and superficial wash water rate Jw and frother concentration increase. Gas holdup is proportional to superficial gas rate as well as frother concentration and superficial wash water rate (at the fixed superficial gas rate).

Mechanical Performance Evaluation of Cement Paste with Foaming Agent using FEM Analysis Based on Picture Image (화상 이미지 기반 FEM 해석을 이용한 기포제 혼입 시멘트 페이스트의 역학 성능 평가)

  • Kim, Bo-Seok;Shin, Jun-Ho;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.1
    • /
    • pp.35-43
    • /
    • 2016
  • Concrete is a representative heterogeneous material and mechanical properties of concrete are influenced by various factors. Due to the fact that pores in concrete affect determining compressive strength of concrete, studies which deal with distribution and magnitudes of pores are very important. That way, studies using picture imaging have been emerged. Studies on mechanical performance evaluation of structural lightweight foamed concrete and FEM analysis based on picture image are inadequate because lightweight foamed concrete has been researched for only non-structural. Therefore, in this study, cement paste with foaming agent to evaluate mechanical performance is made, FEM analysis with picture image is conducted and young's modulus of experiment and analysis are compared. In this study, dosage of foaming agent is determined 7 level to check pore distribution and water-binder ratio is determined 20% to progress research about structural light weight foamed concrete. Weight of unit volume is minimum at 0.8% of foaming agent dosage. However, weight of unit volume is increased over 0.8% of foaming agent dosage because of interconnection with independent pores. For FEM analysis, cement paste is photographed to use image analyzer(HF-MA C01). Consequently, the fact that Young's Modulus of experiment and FEM analysis are same is drawn by using OOF(Object Oriented Finite elements).

액체내에서의 기포형성 모델

  • 곽호영
    • Journal of the KSME
    • /
    • v.23 no.4
    • /
    • pp.280-287
    • /
    • 1983
  • 본 해설에서는 전자 즉 용액내에서 용해되어 있는 기체 분자의 모임에 의한 기포형성에 대해 다루려고 한다. 제 2절에는 Becker-Doring에 의한 고전이론과 그 문제점을 다루고 3절에서는 새로운 관점에서 본 용액내에서 기포를 형성하는 데 필요한 표면 에너지를, 4절에서는 기포형 성에 대한 열역학적인 면에서의 고찰, 5절에서는 용액내에서의 기포형성 모델에서 기포형성을 위한 압력강하를 구하는 방법의 종류와 그 온도에 따른 기포형성에 대해 논하기로 하고 증기로된 기포형성(vapor bubble formation)에 대하여는 다음 기회에 논하기로 한다.

  • PDF

Processing of Polyurhane Microcellular Foam for Thermal Insulation (단열재용 폴리우레탄 미세포 포움의 가공)

  • 윤재륜
    • The Korean Journal of Rheology
    • /
    • v.9 no.4
    • /
    • pp.190-199
    • /
    • 1997
  • 단열용도의 폴리우레탄 미세포 포움의 가공에 대한 연구를 수행하였다. 미세포 구조 를 얻기 위해서는 핵생성율을 증진시키고 균일한 분포의 기포를 생성시켜야 한다. 이를 위 해 이산화탄소 기체를 풀리올과 이소시아네이트에 각각 과포화시키고 충돌혼합하여 초음파 가진을 적용하였다. 이산화탄소 기체가 수지 내부에서 기포 내부로 확산함에 따라 기포의 성장이 조절된다고 가정하고 금형이 충전되는 동안에 금형 내부에서의 기포성장기구를 이해 하기 위하여 수치적인 방법으로 이론적 연구를 수행하였다. 경화 시간과 확산 경계를 고려 하여 최종적인 기포의 크기를 계산하였으며 반응속도론을 고려하여 중합반응동안의 폴리우 레탄의 점도의 변화를 예측하고 경화 시간을 결정하였다. 실험적으로 결정된 기체 분자수를 기준으로 하여 이론적으로 확산경계를 예측하였다. 화학적 발포제인 물과 함께 물리적 발포 제인 이산화탄소를 각각 1,2,3기압의 포화압력으로 변화시키면서 폴리올과 이소시아네이트에 포화시켜 폴리우레탄 포움을 제작하고 제작된 포움의 밀도, 열전도도, 및 기포의 수와 지름 을 측정하였다. 측정된 결과로부터 이산화탄소의 포화압력과 초음파 가진이 포움의 기포핵 생성에 미치는 영향을 살펴보았다.