Kim, Jin-Man;Kwak, Eun-Gu;Oh, Kwang-Chin;Kang, Cheol
Journal of the Korea Concrete Institute
/
v.23
no.2
/
pp.151-158
/
2011
Bubbles within the foamed concrete manufactured by pre-foaming method is the main factor which affects the physical properties of foamed concrete such as density, strength, and porosity. Although many researches on foamed concrete have been continuously carried out, insufficient number of researches on the properties related to bubbles in the foamed concrete has been performed except for chemical application related researches. In order to make an optimal foamed concrete, study on the bubble properties must be pursued. In order to effectively implement bubbles in the manufacturing of foamed concrete, the bubble properties must be estimated. In this study, in order to determine the bubble properties, examination of the bubble properties according to types and foaming agent concentration was performed. An foaming agent used for this test were anionic surfactant, rosin, and protein system with the foaming agent concentration range of 0.05~13%. Test parameters considered in the study were foaming rate, foam volume, drainage solution volume, and bubble size. The study results showed that, regardless of foaming agent type, higher concentration of foaming agent showed an increase in the foaming rate. Also, the results showed that concentration of foaming agent affected bubble size, drainage solution volume change, and bubble distributions. With respect to the stability of the bubble, protein foaming agent was better than anion surfactant or rosin foaming agent. With respect to the bubble shape, anion surfactant and rosin formed bubbles had polygon shape where as protein formed bubbles had spherical shape.
Journal of the Korea Institute of Building Construction
/
v.9
no.4
/
pp.63-73
/
2009
Recently, the use of lightweight panels in building structures has been increasing. Of the various lightweight panel types, styrofoam sandwich panels are inexpensive and are excellent in terms of their insulation capacity and their constructability. However, sandwich panels that include organic material are quite vulnerable to fire, and thus can numerous casualties in the event of a fire due to the lack of time to vacate and their emission of poisonous gas. On the other hand, lightweight foamed concrete is excellent, both in terms of its insulation ability and its fire resistance, due to its Inner pores. The properties of lightweight concrete is influenced by foaming agent type. Accordingly, this study investigates the insulation properties by foaming agent type, to evaluate the possibility of using light-weight foamed concrete instead of styrene foam. Our research found thatnon-heating zone temperature of lightweight foamed concrete using AP (Aluminum Powder) and FP (animal protein foaming agent) are lower than that of light-weight foamed concrete using AES (alkyl ether lactic acid ester). Lightweight foamed concrete using AES and FP satisfied fire performance requirements of two hours at a foam ratio 50, 100. Lightweight foamed concrete using AP satisfied fire performance requirements of two hours at AP ratio 0.1, 0.15. The insulation properties were better in closed pore foamed concrete by made AP, FP than with open pore foamed concrete made using AES.
Kim, Seong Wan;Kang, Sin Up;Cho, Seong Seup;Sung, Chan Yong
Korean Journal of Agricultural Science
/
v.10
no.2
/
pp.310-323
/
1983
To study the effect of foaming agent on the production and property of light weight concrete, the tests of compressive, tensile, bending strengths and absorption rates of mortar were done under the different mixing ratio with J, A and D foaming agents. The results obtained were summarized as follows : 1. The strengths were decreased in richer mixing ratio and more addition of foaming agent. The decrease of strengths was the greatest at the level of 0.75% of foaming agent. The decreasing rate of strengths was in order of J, A and D foaming agent. 2. At the mixing ratio of 1:1, ${\sigma}_{28}$ and 0.75% of foaming agent, the compressive strength was decreased up to 34.9% by D, 47.8% by A and 86.8% by J foaming agent, respectively, the tensile strength was decreased up to 14.8% by D, 20.2% by A and 77.9% by J foaming agent, respectively, bending strength was decreased up to 19.9% by D, 35.0% by A and 79.1% by J foaming agent, respectively. The decrease of compressive strength was more severe than that of tensile and bending strengths. 3. The absorption rates were increased in poorer mixing ratio and more addition of foaming agent. The absorption rate was significantly higher at the early stage of immersed water. The absorption rate was in order of J, A and D foaming agent. 4. The decrease of strengths was inevitable in cement-mortar with foaming agent, but the cement mortar with foaming agent has such the properties of the light-weight, lnsulation, Keeping-warmth, sound proof and fire-proof that if could be utilized to the constructions which need low strengths.
Kim, Jin-Man;Jeong, Ji-Yong;Hwang, Eui-Hwan;Shin, Sang-Chul
Journal of the Korea Concrete Institute
/
v.24
no.1
/
pp.61-70
/
2012
Recently, the government has been working feverously to save energy and reduce greenhouse gas emission by enacting Basic Act on Low Carbon Green Growth at the national level. Improving the insulation performance of building exterior and insulator can reduce the energy in the building sector. This study is about developing light-weight foamed concrete insulation panel that can be applied to buildings to save energy and to find the optimal condition for the development of insulation materials that can save energy by enhancing its physical, kinetic and thermal characteristics. Various experimental factors and conditions were considered in the study such as foam agent types (AES=Alcohol Ethoxy Sulfate, AOS=Alpha-Olefin Sulfonate, VS=Vegetable Soap, FP=Fe-Protein), foam agent dilution concentration (1, 3, 5%), and foam percentage (30, 50, 70%). Experiment results indicated that the surface tension of aqueous solution including foam agent, was lower when AOS was used over other foam agents. FP produced relatively stable foams in 3% or more, which produced unstable foams containing high water content and low surface tension when diluted at low concentration. Depending on foam agent types, compressive strength and thermal conductivity were similar at low density range but showed some differences at high concentration range. In addition, when concentrations of foam agent and foaming ratio increased, pore size increased and open pores are formed. In all types of foam agent, thermal conductivity were excellent, satisfying KS standards. The most outstanding performance for insulation panel was obtained when FP 3% was used.
This study was performed to obtain the basic data which can be applied to use of foaming mortars. The results obtained were summarized as follows ; 1. The lowest water-cement ratios were shown at the mixing ratio of 1 : 1. But, it was gradually increased in poorer mixing ratio and decreased in more addition of foaming agent. The water-cement ratios were decreased up to 1.6-53.1% by mix-foaming type and 4.4-24.1% by pre-foamed type than cement mortar. 2. The highest bulk densities were shown at the mixing ratio of 1 : 1. But, it was gradually decreased in poorer mixing ratio and more addition of foaming agent. The decreasing rates of bulk densities were increased in richer mixing ratio and more addition of foaming agent. 3. The bulk densities were decreased up to 38.8-55.9% by mix-foaming type and 9.7-23.6% by pre-foamed type than cement mortar. 4. The lowest absorption rates were shown at the mixing ratio of 1 : 1. But, it was gradually increased in poorer mixing ratio and more addition of foaming agent. The increasing rates of absorption rates were increased in richer mixing ratio and more addition of foaming agent. 5. Absorption rates when immersed in 72hours were shown up to 3.41-5.85 times greater by mix-foaming type and 1.05-1.55 times greater by pre-foamed type than those of cement mortar. it was significantly higher at the early stage of immersed time than cement mortar. 6. The highest strengths were shown at the mixing ratio of 1 : 1. But, it was gradually decreased in poorer mixing ratio and more addition of foaming agent. The decreasing rates of strengths were increased in poorer mixing ratio and more addition of foaming agent. 7. The strengths were decreased up to 77.0-92.8% by mix-foaming type and 36.7-74.4% by pre-foamed type than cement mortar. 8. The lowest air contents were shown at the mixing ratio of 1 : 1. But, it was gradually increased in poorer mixing ratio and more addition of foaming agent. The increasing rates of air contents were increased in richer mixing ratio and more addition of foaming agent. 9. Air contents were shown up to 26.0-63.8 times greater by mix-foaming type and 5.8-17.7 times greater by pre-foamed type than those of cement mortar. 10. The correlations between bulk density, absorption rate, compressive strength and air content were highly significant. The multiple regression equations of bulk density, absorption rate, compressive strength, tensile strength, bending strength and air content were computed depending on a function of mixing ratio and addition of foaming agent. They were generally highly significant.
Kim, Seong Wan;Kang, Sin Up;Cho, Seong Seup;Sung, Chan Yong
Korean Journal of Agricultural Science
/
v.11
no.1
/
pp.133-145
/
1984
To study the effect of foaming agent on the characteristic of mortar, the tests of water-cement ratio and bulk density of mortar were done under the different mixing ratio with G. U and J foaming agents. The results obtained were summarized as follows: 1. At the mixing ratio of 1 : 4 and 0.5% of foaming agent, the highest water-cement ratio was 90% by G, 88.3% by U and 70% by J foaming agent, respectively, being lower than 91.6% of that of cement mortar. 2. At the mixing ratio of 1 : 3 and 3.0% of foaming agent, the water-cement ratio was decreased up to 22.0% by G and 24.1% by U foaming agent, respectively, but it gradually was increased in richer and poorer mixing ratio. At the mixing ratio of 1 : 4 and 3.0% of foaming agent, the water-cement ratio was decreased up to 53.1% by J foaming agent, but it gradually was increased in richer mixing ratio. 3. At the mixing ratio of 1 : 1 and 0.5% of foaming agent, the highest bulk density was $1.981g/cm^3$ by G, $1.863g/cm^3$ by U and $1.149g/cm^3$ by J foaming agent, respectively, being lower than $2.048g/cm^3$ of that of cement mortar. 4. At the mixing ratio of 1 : 2 and 3.0% of foaming agent, the bulk density was decreased up to 20.7% by G, 23.7% by U and 56.5% by J foaming agent, respectively, but it gradually was increased in richer and poorer mixing ratio. 5. The water-cement ratio and bulk density were decreased in more addition of foaming agent, respectively, multiple regression equations of water-cement ratio and bulk density were computed depending on a function of mixing ratios and addition of foaming agents.
Bubble size in froth flotation has long been recognized as a key factor which affects the bubble residence time, the bubble surface area flux (Sb) and the carrying rate (Cr). This paper presents method of bubble size measurement, relationship between operating variables and gas dispersion properties in flotation column. Using high speed camera and image analysis system, bubble size has been directly measured as a function of operating parameters (e.g., superficial gas rate (Jg), superficial wash water rate (Jw), frother concentration) in flotation column. Relationship compared to measured and estimated bubble size was obtained within error ranges of ±15~20% and mean bubble size was 0.718mm. From this system the empirical relationship to control the bubble size and distribution has been developed under operating conditions such as Jg of 0.65~1.3cm/s, Jw of 0.13~0.52cm/s and frother concentration of 60~200ppm. Surface tension and bubble size decreased as frother concentration increased. It seemed that critical coalescence concentration (CCC) of bubbles was 200ppm so that surface tension was the lowest (49.24mN/m) at frother concentration of 200ppm. Bubble size tend to increase when superficial gas rate (Jg) decreases and superficial wash water rate Jw and frother concentration increase. Gas holdup is proportional to superficial gas rate as well as frother concentration and superficial wash water rate (at the fixed superficial gas rate).
Journal of the Korea Institute of Building Construction
/
v.16
no.1
/
pp.35-43
/
2016
Concrete is a representative heterogeneous material and mechanical properties of concrete are influenced by various factors. Due to the fact that pores in concrete affect determining compressive strength of concrete, studies which deal with distribution and magnitudes of pores are very important. That way, studies using picture imaging have been emerged. Studies on mechanical performance evaluation of structural lightweight foamed concrete and FEM analysis based on picture image are inadequate because lightweight foamed concrete has been researched for only non-structural. Therefore, in this study, cement paste with foaming agent to evaluate mechanical performance is made, FEM analysis with picture image is conducted and young's modulus of experiment and analysis are compared. In this study, dosage of foaming agent is determined 7 level to check pore distribution and water-binder ratio is determined 20% to progress research about structural light weight foamed concrete. Weight of unit volume is minimum at 0.8% of foaming agent dosage. However, weight of unit volume is increased over 0.8% of foaming agent dosage because of interconnection with independent pores. For FEM analysis, cement paste is photographed to use image analyzer(HF-MA C01). Consequently, the fact that Young's Modulus of experiment and FEM analysis are same is drawn by using OOF(Object Oriented Finite elements).
본 해설에서는 전자 즉 용액내에서 용해되어 있는 기체 분자의 모임에 의한 기포형성에 대해 다루려고 한다. 제 2절에는 Becker-Doring에 의한 고전이론과 그 문제점을 다루고 3절에서는 새로운 관점에서 본 용액내에서 기포를 형성하는 데 필요한 표면 에너지를, 4절에서는 기포형 성에 대한 열역학적인 면에서의 고찰, 5절에서는 용액내에서의 기포형성 모델에서 기포형성을 위한 압력강하를 구하는 방법의 종류와 그 온도에 따른 기포형성에 대해 논하기로 하고 증기로된 기포형성(vapor bubble formation)에 대하여는 다음 기회에 논하기로 한다.
단열용도의 폴리우레탄 미세포 포움의 가공에 대한 연구를 수행하였다. 미세포 구조 를 얻기 위해서는 핵생성율을 증진시키고 균일한 분포의 기포를 생성시켜야 한다. 이를 위 해 이산화탄소 기체를 풀리올과 이소시아네이트에 각각 과포화시키고 충돌혼합하여 초음파 가진을 적용하였다. 이산화탄소 기체가 수지 내부에서 기포 내부로 확산함에 따라 기포의 성장이 조절된다고 가정하고 금형이 충전되는 동안에 금형 내부에서의 기포성장기구를 이해 하기 위하여 수치적인 방법으로 이론적 연구를 수행하였다. 경화 시간과 확산 경계를 고려 하여 최종적인 기포의 크기를 계산하였으며 반응속도론을 고려하여 중합반응동안의 폴리우 레탄의 점도의 변화를 예측하고 경화 시간을 결정하였다. 실험적으로 결정된 기체 분자수를 기준으로 하여 이론적으로 확산경계를 예측하였다. 화학적 발포제인 물과 함께 물리적 발포 제인 이산화탄소를 각각 1,2,3기압의 포화압력으로 변화시키면서 폴리올과 이소시아네이트에 포화시켜 폴리우레탄 포움을 제작하고 제작된 포움의 밀도, 열전도도, 및 기포의 수와 지름 을 측정하였다. 측정된 결과로부터 이산화탄소의 포화압력과 초음파 가진이 포움의 기포핵 생성에 미치는 영향을 살펴보았다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.