• Title/Summary/Keyword: 기포류

Search Result 65, Processing Time 0.029 seconds

Comparison of Reduction Reactivity of New Oxygen Carriers for Chemical Looping Combustion System in a Bubbling Fluidized Bed (기포유동층에서 케미컬루핑 연소시스템을 위한 신규 산소전달입자들의 환원반응성 비교)

  • KIM, HANA;LEE, DOYEON;BAE, DAL-HEE;SHUN, DOWON;BAEK, JEOM-IN;RYU, HO-JUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.5
    • /
    • pp.554-560
    • /
    • 2017
  • Reduction reactivity of new oxygen carriers for chemical looping combustion system were investigated using $CH_4$ as a reduction gas in a bubbling fluidized bed reactor and compared with that of former SDN70 oxygen carrier. New oxygen carriers showed good reduction reactivity at different $CH_4$ concentration. N018-R2 particle represented better reactivity than SDN70 at high $CH_4$ concentration. N018-R2 particle showed higher fuel conversion and $CO_2$ selectivity than those of SDN70 particle within the temperature range of $750-900^{\circ}C$. Moreover, attrition loss of N018-R2 particle was almost same with that of SDN70 particle. Consequently, we could select N018-R2 particle as the best oxygen carrier.

Experimental Study on the Dissociation Characteristics of Methane Hydrate Pellet by Hot Water Injection (열수 주입법에 의한 메탄가스 하이드레이트 펠릿의 해리 특성에 관한 실험 연구)

  • Lee, Seung-Han;Yoon, Yong-Seok;Seong, Kwan-Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1177-1184
    • /
    • 2011
  • Gas-to-Solid (GTS) technology is composed of three stages: hydrate production, transportation, and regasification. For efficient operation of regasification plants, it is crucial to predict the temperature and flow rate of hot water necessary to dissociate the hydrate pellets. Dissociated gas escaping from the pellet surface, when in contact with hot water, will alter the flow field and consequently alter the heat transfer rate. Methane hydrate pellet dissociation characteristics in low- to moderatetemperature water were investigated by taking images of the changes in the hydrate pellets' shapes in a pressurized reactor and measuring the total time required for complete melting of the pellets. The effects of water temperature, hydrate conversion rate, and flow speed on the dissociation completion time were also investigated. Bubbling gas released from the pellet surface induced a secondary flow that enhanced the heat transfer rate and thus decreased the dissociation time. It was also found that a considerable flow rate was needed to significantly decrease the dissociation time.

Bio-oil production from Chlorella sp. KR-1 using carbon dioxide from bubble column (기포탑에서 이산화탄소를 이용한 Chlorella sp. KR-1로부터 바이오오일 생산)

  • Lee, Ja-Youn;Seo, Kyoung-Ae;Park, Soon-Chul;Lee, Jin-Suk;Oh, You-Kwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.513-513
    • /
    • 2009
  • 최근 바이오디젤의 원료로 미세조류가 많은 관심을 끌고 있다. 미세조류는 물, 이산화탄소와 태양광을 이용해 광합성 성장이 가능하며, 지질(오일) 성분이 풍부하여 바이오디젤의 원료로 이용할 수 있다. 미세조류는 단위 면적당 오일 생산량이 곡물류의 50-100배 이상이며, 이산화탄소를 기질로 이용하므로 온실가스 직접 저감이 가능하다. 또한 배양시 비경작지나 황무지를 사용할 수 있으므로 기존 식용작물과 경쟁하지 않으며, 하수, 해수, 폐수 등 다양한 물자원을 이용할 수 있다. 본 연구에서는 고농도 $CO_2$에 내성을 지닌 Chlorella sp. KR-1을 대상으로 1 L 규모 기포탑 광생물반응기에서 균체 성장 및 지질(바이오오일) 합성에 대한 $CO_2$ 농도, 가스 공급속도, 질산염 농도 등 환경 및 영향 조건의 영향을 조사하였다. 가스 공급속도 0.4 L/min에서 $CO_2$ 농도를 0.03-20% 범위에서 조사하였을 때 최대 균체성장은 $CO_2$ 10%에서 관찰되었다. 균체내 지방산 함량은 $CO_2$ 농도 0.03%에서 가장 낮았고, 5-20% 범위에서는 $CO_2$ 농도 증가에 따라 감소하는 경향이 관찰되었다. 가스 공급속도를 0.2 L/min에서 0.8 L/min으로 증가시켰을 때 최대 균체농도는 0.6-0.8 L/min의 범위에서 관찰되었고, 생체내 최대 지방산 함량은 0.4 L/min에서 관찰되었다. Nitrate 농도 1-20 mM 범위에서 최종 균체농도는 nitrate 농도 증가에 따라 10mM까지 증가하였으나 그 이상에서는 증가하지 않았다. 반면 지방산 함량은 nitrate 농도 증가에 따라 감소하는 경향이 관찰되었다. 본 실험에서 얻은 최대 지방산 생산량은 1,100 mg/L이었으며, 주요 지방산은 C10:0(1.7%), C16:0(28.5%), C18:0(11%), C18:1n9c(25.9%), C18:2n6c(26.3%), C18:3n3(6.6%)이었다. 현재 100 L 규모 광생물반응기에서 석탄발전소 배가스($CO_2$ 12-15%, SOx 50ppm, NOx 100ppm)를 이용한 바이오오일 생산 실험이 진행 중이다.

  • PDF

A Model on a Bubbling Fluidized Bed Process for CO2 Capture from Flue Gas (연소기체로부터 CO2를 포집하는 기포 유동층 공정에 관한 모델)

  • Choi, Jeong-Hoo;Youn, Pil-Sang;Kim, Ki-Chan;Yi, Chang-Keun;Jo, Sung-Ho;Ryu, Ho-Jung;Park, Young-Cheol
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.516-521
    • /
    • 2012
  • This study developed a simple model to investigate effects of important operating parameters on performance of a bubbling-bed adsorber and regenerator system collecting $CO_2$ from flue gas. The chemical reaction rate was used with mean particles residence time of a reactor to determine the extent of conversion in both adsorber and regenerator reactors. Effects of process parameters - temperature, gas velocity, solid circulation rate, moisture content of feed gas - on $CO_2$ capture efficiency were investigated in a laboratory scale process. The $CO_2$ capture efficiency decreased with increasing temperature or gas velocity of the adsorber. However, it increased with increasing the moisture content of the flue gas or the regenerator temperature. The calculated $CO_2$ capture efficiency agreed to the measured value reasonably well. However the present model did not agree well to the effect of the solid circulation rate on $CO_2$ capture efficiency. Better understanding on contact efficiency between gas and particles was needed to interpret the effect properly.

Effects of the Free-Stream Turbulence and Surface Trip Wire on the Flow past a Sphere (자유류 난류와 표면 트립 와이어가 구 주위 유동에 미치는 영향)

  • Son, Kwang-Min;Choi, Jin;Jeon, Woo-Pyung;Choi, Hae-Cheon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.187-190
    • /
    • 2006
  • In the present study, effects of tree-stream turbulence and surface trip wire on the flow past a sphere at $Re\;=\;0.4\;{\times}\;10^5\;{\sim}\;2.8\;{\times}\;10^5$ are investigated through wind tunnel experiments. Various types of grids are installed upstream of the sphere in order to change the tree-stream turbulence intensity. In the case of surface trip wire, 0.5mm and 2mm trip wires are attached from $20^{\circ}\;{\sim}\;90^{\circ}$ at $10^{\circ}$ interval along the streamwise direction. To investigate the flow around a sphere, drag measurement using a load cell, surface-pressure measurement, surface visualization using oil-flow pattern and near-wall velocity measurement using an I-type hot-wire probe are conducted. In the variation of free-stream turbulence, the critical Reynolds number decreases and drag crisis occurs earlier with increasing turbulence intensity. With increasing Reynolds number, the laminar separation point moves downstream, but the reattachment point after laminar separation and the main separation point are fixed, resulting in constant drag coefficient at each free-stream turbulence intensity. At the supercritical regime, as Reynolds number is further increased, the separation bubble is regressed but the reattachment and the main separation points are fixed. In the case of surface trip wire directly disturbing the boundary layer flow, the critical Reynolds number decreases further with trip wire located more downstream. However, the drag coefficient after drag crisis remains constant irrespective of the trip location.

  • PDF

CH4 Combustion Characteristics of Oxygen Carriers in a Bubbling Fluidized Bed (기포유동층에서 산소전달입자들의 메탄 연소특성)

  • RYU, HO-JUNG;PARK, YOUNGCHEOL;LEE, SEUNG-YONG;JO, SUNG-HO;SHUN, DOWON;BAEK, JEOM-IN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.5
    • /
    • pp.581-588
    • /
    • 2016
  • To compare reduction reactivity of oxygen carrier particles, $CH_4$ combustion characteristics were measured and investigated in a bubbling fluidized bed reactor with increasing $CH_4$ concentration from 10 to 100 %. Among five oxygen carriers (OC-1, OC-2, SDN70, C14, C28), OC-1, OC-2, SDN70 particles were selected as better oxygen carriers from the viewpoints of fuel conversion and $CO_2$ selectivity. However, some oxygen carriers showed lower fuel conversion and $CO_2$ selectivity even though they have high oxygen transfer capacity. Therefore, we could conclude that not only TGA tests to measure the oxygen transfer capacity but also fluidized bed tests to analyze exhaust gas concentration should be performed to select better oxygen carrier without misunderstanding of carriers reactivity.

Reduction Characteristics of Oxygen Carriers in a Pressurized Bubbling Fluidized Bed (가압 기포유동층에서 산소전달입자들의 환원반응특성)

  • YOON, JOO-YOUNG;BAE, DAL-HEE;BAEK, JEOM-IN;RYU, HO-JUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.5
    • /
    • pp.589-596
    • /
    • 2016
  • Effects of pressure, temperature, gas velocity, and fuel flow rate on reduction of three oxygen carriers, SDN70, OC-1, OC-2, were measured and investigated in a pressurized bubbling fluidized bed reactor. Among three oxygen carriers OC-2 was selected as the best oxygen carrier in view of fuel conversion and $CO_2$ selectivity. However, all oxygen carriers showed good reactivity even at high pressure conditions. SDN70 particle showed maximum reactivity at $900^{\circ}C$ and low reactivity at $950^{\circ}C$. However, reactivity decay of OC-1 and OC-2 particles at high temperature condition was negligible. The fuel conversion and the $CO_2$ selectivity slightly decreased as the gas velocity increased, whereas they are slightly increased as the fuel concentration increased.

Comparison of Solid Circulation Characteristics with Change of Lower Loop Seal Geometry in a Circulating Fluidized Bed (순환유동층에서 하부 루프실 형태 변화에 따른 고체순환 특성 비교)

  • Lee, Dong-Ho;Jo, Sung-Ho;Jin, Gyoung-Tae;Yi, Chang-Keun;Ryu, Ho-Jung;Park, Seung Bin
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.522-529
    • /
    • 2014
  • Circulating fluidized bed system consists of SEWGS reactor - lower loop seal - regeneration reactor - riser - cyclone - upper loop seal has been used for solid circulation between the SEWGS reactor and the regeneration reactor in a SEWGS system for pre-combustion $CO_2$ capture. A vertical type lower loop seal has been used in current system but this lower loop seal requires high gas flow rate through the lower loop seal for fluidization and smooth solid circulation, and consequently, causes slugging behavior sometimes. To overcome these disadvantages, inclined type lower loop seal was proposed by this study. Solid circulation characteristics with change of lower loop seal geometry were measured and compared in a bubbling - bubbling - riser type circulating fluidized bed using $CO_2$ absorbent (P-78) as bed material at ambient temperature and pressure. We could conclude that the inclined lower loop seal is better than the vertical type lower loop seal from the viewpoints of minimum flow rate requirement for stable solid circulation and solid height change during solid circulation.

Fluid Inclusion Study of the Samcheonpo Amethyst Deposit of Kyongsangnamdo, Korea (경상남도 삼천포 광산의 자수정에 대한 유체포유물 특성)

  • Bae, Yun-Sue;Yang, Kyoung-Hee
    • Journal of the Mineralogical Society of Korea
    • /
    • v.19 no.3 s.49
    • /
    • pp.153-162
    • /
    • 2006
  • Fluid inclusions in amethyst from the Samcheonpo amethyst deposit of the Waryongsan area, Kyongnam generally grouped into four different types: Type I (liquid-rich and $10{\sim}23wt%$ NaCl, $Th=289{\sim}359^{\circ}C$), Type II (vapor-rich and $2{\sim}10wt%$ NaCl, $Th=304{\sim}365^{\circ}C;$), Type III (halite-bearing, $31{\sim}54wt%$ NaCl, $Th=259{\sim}510^{\circ}C;$), and Type IV ($CO_{2}-bearing\;9{\sim}13wt%\;NaCl,\;126{\sim}277^{\circ}$). Type I, II, and III inclusions are confined in the lower part of the amethyst and Type IV in the upper, which indicates significant hydrothermal activity during the earliest stage of the amethyst growth or the solidus condition of granitic rocks. The earliest fluid exsolved from the crystallizing granitic magma formed Type IIIa which is spatially associated with silicate melt inclusions. The homogenization behavior of Type IIIa inclusions by dissolution of the halite crystal after the bubble disappearance indicates that Type IIIa inclusions were trapped at some relatively elevated pressure. Exsolution of Type IIIb, I, II forming fluids with gradual decrease in their salinity was followed. The last fluid was $CO_{2}-bearing$ fluid (Type IV), which is assumed to be derived by decarbonization reactions with the surrounding sedimentary rocks. It suggests that the fine-grained granitic rocks containing the Samcheonpo amethyst crystallized at the sub-solvus condition saturated with water and exsolved abundant water.

Study of Hydrodynamics and Reaction Characteristics of K-based Solid Sorbents for CO2 Capture in a Continuous System Composed of Two Bubbling Fluidized-bed Reactors (두 개의 기포유동층으로 구성된 연속장치에서 CO2 회수를 위한 K-계열 고체흡수제의 수력학적 특성 및 반응특성)

  • Kim, Ki-Chan;Kim, Kwang-Yul;Park, Young Cheol;Jo, Sung-Ho;Ryu, Ho-Jung;Yi, Chang-Keun
    • Korean Chemical Engineering Research
    • /
    • v.48 no.4
    • /
    • pp.499-505
    • /
    • 2010
  • In this study, hydrodynamics and reaction characteristic of K-based solid sorbents for $CO_2$ capture were investigated using a continuous system composed of two bubbling fluidized-bed reactors(1.2 m tall bed with 0.11 m i.d.). Potassium-based dry sorbents manufactured by the Korea Electric Power Research Institute were used, which were composed of $K_2CO_3$ of 35% for $CO_2$ absorption and supporters of 65% for mechanical strength. The continuous system consists of two bubbling fluidized-bed reactors, solid injection nozzle, riser, chiller, analyzer and heater for regeneration reaction. The minimum fluidizing velocity of the continuous system was 0.0088 m/s and the solid circulation rate measured was $10.3kg/m^2{\cdot}s$ at 1.05 m/s velocity of the solid injection nozzle. The $CO_2$ concentration of the simulated gas was about 10 vol% in dry basis. Reaction temperature in carbonator and regenerator were maintained about $70^{\circ}C$ and $200^{\circ}C$, respectively. Differential pressures, which were maintained in carbonator and regenerator, were about $415mmH_2O$ and $350mmH_2O$, respectively. In order to find out reaction characteristics of dry sorbents, several experiments were performed according to various experimental conditions such as $H_2O$ content(7.28~19.66%) in feed gas, velocity (0.053~0.103 m/s) of simulated gas, temperature($60{\sim}80^{\circ}C$) of a carbonator, temperature($150{\sim}200^{\circ}C$) of a regenerator and solid circulation rate($7.0{\sim}10.3kg/m^2{\cdot}s$). The respective data of operating variables were saved and analyzed after maintaining one hour in a stable manner. As a result of continuous operation, $CO_2$ removal tended to increase by increasing $H_2O$ content in feed gas, temperature of a regenerator and solid circulation rate and to decrease by increasing temperature of a carbonator and gas velocity in a carbonator.