• Title/Summary/Keyword: 기체 복사

Search Result 64, Processing Time 0.026 seconds

The Fundamental Studies of the New Glow Discharge/Inductively Coupled Plasma Interface: Part Ⅰ. Preliminary Studies (새로운 글로우 방전/유도결합 플라스마 장치(GD/ICP Interface)에 대한 기초 연구: Part Ⅰ. 기초 연구)

  • Lee, Gae Ho;Kil, Hyo Shik;Kim, Hyung Seung;Gary M. Hieftje
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.2
    • /
    • pp.182-192
    • /
    • 1999
  • The new GD/ICP-AES quick change over system has been developed and characterized. Within less than 15 minutes, ICP-AES could be switched to GD-AES and vise a versa. As a result, both solid and liquid samples could be analyzed in a very short period of time by the ICP/GD-AES quick change over system developed in our laboratory. The influences of the experimental variables, such as flow rate of coolant gas, flow rate of auxiliary gas, flow rate of sample carrier gas, sampling depth, orifice size of sampling cone, and rf (radio frequency) power on emission intensity have been presented. The detection limits of Cd(I) 228.8 nm, Mn (II) 257.61 nm, and Fe(II) 259.95 nm were found to be 3.86, 1.49, and 5.79 ppb, respectively. And linealities of the calibration curves were measured to be unity.

  • PDF

Application of Open-source OpenFOAM for Simulating Combustion and Heating Performance in Horizontal CGL Furnace (수평형 CGL 소둔로의 연소 및 가열 성능 해석을 위한 오픈소스 OpenFOAM 기반 전산유체 해석)

  • Kim, GunHong;Oh, Kyung-Teak;Kang, Deok-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.8
    • /
    • pp.553-561
    • /
    • 2017
  • The main motivation for this study was to establish a CFD-based procedure for the analysis of heating characteristics, particularly in industrial furnaces. As certain open-source software packages have gained popularity in dealing with complex industrial problems, the OpenFOAM framework was selected for further development of advanced physical models to meet industrial requirements. In this study, the newly developed comprehensive model was applied to simulate physical processes in the full-scale horizontal furnace of a continuous galvanizing line (CGL). The numerical results obtained indicate that the current approach predicts heating characteristics reasonably well. It was also found that radiative heat transfer plays a dominant role in heating the moving strip. To improve the predictability of our method, further work is required to model the turbulence-chemistry interaction realistically, as well as to impose a physically correct thermal wall boundary condition.

Mercury Free Flat Discharge Lamps for LCD Backlighting (LCD 배면광을 위한 무수은 평면방전램프)

  • Shiga, Tomokazu
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.31-38
    • /
    • 2001
  • LCD는 비발광형 소자이므로 배면광이 필요하다. 현재의 LCD 배면광용 냉음극 형광램프는 전기-광학적 특성을 좋게 하기 위하여 수은방전을 사용한다. 그러나 수은의 이용은 외부 온도에 따라 특성이 변하는 결점과 환경 문제가 있다. 이 결점을 보완하기 위하여 원통방전형, 미세방전형 그리고 평면방전형 등 세가지 방식의 무수은 램프가 개발되어 왔다. 원통 방전형 무수은 램프는 수은 대신 Xe을 사용한다. Xe 방전이 수축되는 것을 막기 위하여 한쪽 전극은 외벽에 코일형태로 감아서 사용한다. 그리고 코일형태의 전극의 권선 간격을 조절하여 균일한 방전을 얻는다. 이 형태는 무수은 냉음극 형광램프의 두배의 광속을 얻을 수가 있다. 미세방전형 무수은 램프는 두 개의 절연체로 절연되 금속 전극사이의 방전공간에 수많은 미세방전을 일으켜 발광시킨다. 이 방식은 대향 방전구조와 면 방전구조의 두가지가 있다. 이 방식은 전극이 유전체로 둘러쌓여 있으므로 수명이 높다. 새로운 평면방전형 무수은 램프를 개발하였다. 이 램프는 두 개의 유리평판 사이에 방전공간을 만들고 한쪽 유리면의 양쪽 가장자리에 두 개의 전극을 설치하여 면방전을 유도한다. 양쪽 유리면에는 삼원색 형광체를 도포하고 Xe을 봉입하여 Xe의 진공자외선으로 형광체를 발광시킨다. 이 램프는 전극이 유전체로 덮혀있어 수명이 길다. 실험결과 기체압력 6.7[kPa], 구동전압 1,130[V]에서 최대휘도 9,200[$cd/m^2$], 광효율 20.4[lm/W]을 었었고, 기체 압력 2.7[kPa] 구동전압 1,120[V]에서 최대효율 34.1[lm/W], 휘도 1,080[$cd/m^2$]을 얻었다. 현재 무수은 램프는 수은 램프에 비해서 광학적 특성이 좋지 못하다. 무수은 램프에서 좋은 광학적 특성을 얻기 위해 가장 중요한 것은 수축이 없이 방전을 확산시키는 것이다. 이를 위해서 램프구조와 구동법을 최적화하는 것이 필요하다. 또한 기체압력을 높임으로서 Xe의 여기복사를 얻을 수 있었다.

  • PDF

A Comparison between Various CFD Solvers for Analysis on Thermal Load in Smart Farm(Fluent, Open-FOAM, Blender) (스마트팜 열부하 분석을 위한 CFD 해석 도구 비교)

  • Lee, Jun-Yeob;Oh, Jong-woo;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.170-170
    • /
    • 2017
  • 기후변화 따른 스마트팜 돈사 외부 환경의 변화에 대응하고, 사육 환경을 능동적으로 개선하기 위한 연구가 수행 중이다. 돈사 내 열전달 요소 간 상호 역학성 분석을 위해서 고려해야할 사항은 입기구, 보온 등, 열풍기, 단열제, 위치, 방향, 돈사의 연평균 온도, 습도, 연중 일사량, 가축의 열복사 등 상호 복잡하게 연관되어 있는 물리량이다. 돈사 전체 열손실, 자연발생 에너지량, 강제발생 에너지량, 난방용량 등을 고려한 순간 열부하 산정을 위한 여러 방법 중 우선적으로 CFD(Computational Fluid Dynamics)를 이용하였다. 순간 열부하 산정을 위한 해석 도구 선정에 있어서 다양한 유체 및 기체 전산 유체역학 Solver(Fluent, Open-FOAM, Blender)를 고려하였다. 공간 Mech를 수행하기 위한 도구로는 공개 소프트웨어 인 FreeFem++ 3.51-4 (http://www.freefem.org)를 이용하였다. 이 과정에서 일부 기체 (암모니아)의 농도를 난수로 변화시키는 기법을 적용하여 가상적으로 돈사의 환경을 Pseudo 시뮬레이션 하였다. 결과적으로 Fluent에 비하여 OpenFOAM을 이용하여 얻은 열유동의 방향(속도)과 크기 백터가 상대적으로 크게 나타났다. Fluent가 시계열 상에서 혼합 기체 물리량 변화를 무시할 수 있는 안정되고 균일한 환경에 적합하기 때문인 것으로 판단되었다. Blender의 경우 Lattice Boltzmann methods 과 Smoothed-particle hydrodynamics 방법을 이용한 유체/입자 동력학 모델링을 제공함에 있어 시각적 효과를 강조하는 기능에 중점을 두었다. Fluent와 Blender에서 제공하는 해석 연산 모듈의 정확성 검증을 위해선 공간 분해능을 높인 정밀 계측 시스템을 이용하여 검증할 필요가 있다. Open-FOAM를 이용한 열부하 분석 수행이 상대적으로 높은 절대값을 보이는 특성은 열부하 제어 시스템의 Overshoot를 유발할 가능성이 있으므로 이에 대한 해석 모델의 보정이 추가적으로 필요할 것이다. CFD의 한계인 시간 복잡도를 낮추고 상대적으로 높은 시계열 분해능을 확보할 경우 돈사 내 환기시스템에 맞는 소요 환기량 실시간 산정이 가능해지고 외부기상 및 돈사내부 복사열을 활용함과 동시에 돈군 순환에 상응하는 실시간 열부하 관리 시스템 도출이 가능할 것이다.

  • PDF

Design and Performance Test of a Direct Cooling Equipment for Hydrogen Liquefaction (수소액화용 직접냉각장치의 설계 및 성능시험)

  • Baik, Jong-Hoon;Kang, Byung-Ha;Chang, Ho-Myung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.7 no.2
    • /
    • pp.121-128
    • /
    • 1996
  • A direct cooling equipment for hydrogen liquefaction has been developed and tested. A direct cooling equipment consists of a liquefaction vessel, a radiation shield, a cryostat and a GM refrigerator. The cool-down and warm-up characteristics of the liquefaction apparatus have been investigated in detail. It is found that the hydrogen starts to be liquefied in the liquefaction vessel after 45 minutes of cool-down. The cool-down and warm-up tests of helium gas are also performed. The cool-down and warm-up characteristics of helium gas are found to be very different from those of hydrogen gas, since helium is not liquefied under the present operating conditions. When the liquefaction vessel is evacuated, natural convection phenomena of charged gas in liquefaction vessel can be removed. It is seen that the cool-down time of liquefaction vessel is substantially increased in vacuum environment.

  • PDF

Calculation of the Absorption Coefficient and Weighting Factor Expressing the Total Emissivity of Flame (화염의 총괄폭사 계수를 나타내는 급수계수 및 가중치의 계산)

  • 하만영;허병기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.1
    • /
    • pp.121-130
    • /
    • 1986
  • Using the sbsorption coefficients and the weighting factors of the gray gas, the total emissivities of C $O_{2}$- $H_{2}$O and C $O_{2}$- $H_{2}$O- transient species-soot gas mixtures can be expressed by the following equation, [a numerical formula] Where, $a_{i}$ and $K_{i}$ represent the weighting factor and the absorption coeffient of i-gray gas respectively; L is the pathlength of the gas. This equation is widely used for the analyses of the radiation heat transfer in the combustors of internal combustion engines and in the furnace of external combustion engines. In this work, a simple calculation model of the weighting factor and the absorption coeffient of the above equation was developed. The weighting factors and the absorption coefficients of combustion products were calculated by applying the model to various kinds of fossil fuels such as coal and heavy oil. Then, the computed total emissivities for each fuel and pathlength were compared with measured and calculated values which have been already published in the literatures. The followings were the results obtained through the comparisons between the calculated emissivites and the published values; the developed model for the calculations of the weighting factor and the absorption coefficient of C $O_{2}$- $H_{2}$O and C $O_{2}$- $H_{2}$O- transient species-soot gas mixtures could be applied over the wide ranges of the temperature and the pathlength; the errors between the total emissivities calculted and the values published were maximum 10%, and average 1%, respectively.

Sensitivity of COMS/GOCI Measured Top-of-atmosphere Reflectances to Atmospheric Aerosol Properties (COMS/GOCI 관측값의 대기 에어러솔의 특성에 대한 민감도 분석)

  • Lee, Kwon-Ho;Kim, Young-Joon
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.6
    • /
    • pp.559-569
    • /
    • 2008
  • The Geostationary Ocean Color Imager (GOCI) on board the Communication Ocean Meteorological Satellite (COMS), the first geostationary ocean color sensor, requires accurate atmospheric correction since its eight bands are also affected by atmospheric constituents such as gases, molecules and atmospheric aerosols. Unlike gases and molecules in the atmosphere, aerosols can interact with sunlight by complex scattering and absorption properties. For the purpose of qualified ocean remote sensing, understanding of aerosol-radiation interactions is needed. In this study, we show micro-physical and optical properties of aerosols using the Optical Property of Aerosol and Cloud (OPAC) aerosol models. Aerosol optical properties, then, were used to analysis the relationship between theoretical satellite measured radiation from radiative transfer calculations and aerosol optical thickness (AOT) under various environments (aerosol type and loadings). It is found that the choice of aerosol type makes little different in AOT retrieval for AOT<0.2. Otherwise AOT differences between true and retrieved increase as AOT increases. Furthermore, the differences between the AOT and angstrom exponent from standard algorithms and this study, and the comparison with ground based sunphotometer observations are investigated. Over the northeast Asian region, these comparisons suggest that spatially averaged mean AOT retrieved from this study is much better than from standard ocean color algorithm. Finally, these results will be useful for aerosol retrieval or atmospheric correction of COMS/GOCI data processing.

Thermal Isolation Technology for Cryogenic Cooling Devices (극저온 냉각 장치를 위한 단열 기술)

  • 김호영;강병하
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.11
    • /
    • pp.24-30
    • /
    • 2002
  • 본 글에서는 정밀 전자 소자등을 극저온으로 냉동시키는 데 필요불가결한 극저온 단열 기술에 대하여 간단히 알아보았다. 역사가 가장 오래되고 기본적인 진공 단열 기술로 시작하여, 공간에 고형의 물질을 삽입하는 다층 단열 기술과 분말 단열 기술에 대하여 토의하였다. 실제 응용시에는 요구되는 열적 성능과 경제적 제한 조건을 고려하여 가장 적합한 단열 방법을 선정하도록 하여야한다 또한 극저온 단열 용기의 실제 열해석 예로서 적외선 센서의 극저온 용기에 대한 정상 및 과도 열전달 해석에 대하여 간단히 기술하였다. 정상상태의 경우는 많은 경우 해석적인 해를 구할 수 있지만, 시간에 따라 온도가 변하는 과도 상태의 경우는 수치해석적인 방법이 요구된다. 열해석에서 일반적으로 쓰이는 유한차분법이 극저온 단열 용기의 열해석에도 유용하게 쓰일 수 있음을 보였다.

Analysis of the Burning Rate of Solid Propellant Accounting for the Evaporation on the Surface (표면 증발을 고려한 고체추진제의 연소율 해석)

  • 이창진
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.1
    • /
    • pp.41-47
    • /
    • 1999
  • The burning rate of solid propellant is one of the key parameter associated with the dynamic characteristics of combustion and the combustion performances. In the AP propellants, the evaporation on the reacting surface as well as the decomposition of the propellant is of great importance in determining the overall burning rate. In this study, a theoretical analysis was conducted to obtain the expression for burning rate in the steady state combustion with the energy and species equations in the condensed phase when the radiative heat flux partially contributes to the total heat transfer to the propellant surface.

  • PDF

Experimental study of solid fuel ignition in a confined enclosure (밀폐공간내 복사에 의한 고체연료 점화의 실험적 연구)

  • Kim, Yeong-Gwan;Baek, Seung-Uk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.11
    • /
    • pp.3630-3638
    • /
    • 1996
  • An experimental study has been conducted to explore the behaviors of the radiative ignition of polymethylmetacrylate(PMMA) in a confined enclosure such as the ignition delay time, PMMA surface temperature, the ignition location and the ignition process. In addition, the effects of hot wall orientation on the ignition delay and PMMA surface temperature were studied. When the hot wall is located at the bottom, ignition delay time is the shortest. Ignition surface temperature becomes the lowest for the hot top wall case. These are due to buoyancy effect. Since the radiative heat flux of hot wall is rather lower than laser source, the ignition is considered to be controlled by the mixing process. Therefore, the ignition location, where appropriate mixture of fuel and oxygen exists, occurs near the hot wall. The flame propagates along the hot wall where there exists sufficient oxygen.