• Title/Summary/Keyword: 기준 지하수위

Search Result 142, Processing Time 0.022 seconds

A Study on the Stability of Slopes Reinforced with Panel-Type Retaining Walls (대절토부 사면의 패널식 옹벽보강에 따른 안정성 검토)

  • Dong-wook Choi;Jun-o Park;Daehyeon Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.2
    • /
    • pp.1-7
    • /
    • 2024
  • Various innovative technologies and methods are being applied to ensure the stability of steep rock slopes. However, there are design limitations concerning site ground conditions, leading to discrepancies between the designed and actual ground conditions during construction. In the case of the retaining wall in Yeosu, where the study area is located, although the construction of a 5-stage retaining wall is planned, at the current completion of the second stage, cracks on the upper part of the wall, settlement in the front of the wall, and seepage have been observed. After the completion of stages one and two, issues regarding cracks and settlement on the upper part of the wall and seepage in the front of the wall were discovered. Thus, there was a need to reevaluate the results of the existing stability assessment. It was confirmed that the issue was due to groundwater leakage, attributed to the lack of clear assessment of the colluvial soil layer during the initial design stage. Therefore, to conservatively reflect groundwater level conditions, a groundwater level contour was positioned at the top of the wall to conduct a slope stability assessment. The assessment results indicated that the safety factor during the rainy season exceeded the required value of 1.3, with a calculated safety factor of 1.31. However, during seismic events, the safety factor was determined to be 1.12, falling short of the required safety factor of 1.3. Therefore, it is suggested that the existing retaining walls constructed during stages one and two undergo reinforcement using methods such as micro-piles with grouting, and additional work should be carried out to ensure a clear assessment of the colluvial soil layer.

Introduction and Classification System of Reservoir Park Mitigating Flood (홍수대응 다목적 재해대응 저류공원의 도입과 분류체계 연구)

  • Moon, Soo-Young;Jung, Seung-Hyun;Yun, Hui-Jae
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.12
    • /
    • pp.646-659
    • /
    • 2018
  • This study proposed "Reservoir Park", which added disaster prevention function to urban green spaces such as city parks through domestic and overseas related laws review, case studies, field trips. This is a combination of urban parks and reservoirs as urban planning facilities, which can provide both space for daily use by urban residents and disaster mitigation functions in case of emergency. In order to prevent flooding in urban areas due to climate change, facilities should be installed in the form of parks, etc., as the reservoir facility should be systematically reviewed together with urban planning facilities. However it was found that the reservoir park was not clear as a theme park. In this study, the types of storage facilities in urban areas were reclassified into five types of storage parks reflecting the characteristics of urban green spaces through domestic case studies and field trips. The classification of the reservoir parks is classified into 5 kinds such as ecological type, vegetation cover type, exercise facility type, underground burial type and hybrid type based on groundwater level, human use, and reservoir size. This classification system can be used to determine the types of facilities to be built after designating the location of future storage facilities.

Suitability Grouping System of Paddy Soils for Multiple Cropping -Part I: Basic Experiments (다모작(多毛作)을 위한 답토양(畓土壤) 적성등급(適性等級) 구분(區分) -제(第) 1 보(報) : 기초시험(基礎試驗))

  • Jung, Yeun-Tae;Park, Eun-Ho;No, Yeong-Pal;Um, Ki-Tae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.19 no.3
    • /
    • pp.211-216
    • /
    • 1986
  • To establish a suitability grouping system of paddy soils for double or multiple cropping with rice which is intensively practiced in the southern parts of Korea, a few basic experiments were carried out for two years. The results are summarized as follows; 1. The potential productivities of the paddy soils which were tested without any fertilizer in the pots of subsoil samples by the double cropping of rice and other upland crops were resulted that the soils of "Moderately well drained" fine silty textured were the highest while the soils of "Poorly drained" sandy were the lowest, and the productivities could be clearly comparable according to the differences of soil conditions. 2. The decomposability of organic matter also was higher in the soils of "Moderately well drained" than the "Imperfectly drained". The coarse loamy and coarse silty textured soils were high in the upland condition and in the early stages of submerging while the fine loamy and fine silty textured soils were high at the late stage of submerging in the rates of organic matter decomposition. 3. The days to be reached to tillable condition after rainfall in fine loamy textured soils were about 5 days earlier than the clayey soils. The period of tillable condition of fine clayey soils with "Moderately well drained" was the longest and that of the fine loamy textured soils was the shortest. But the soils with "Imperfectly drained" were not clear among soil textural classes. 4. The lower the ground water table the higher was the productivity indices. The variation of ground water table in the medium textured soils was higher than the both of coarse and fine textured soils among "Moderately well drained". But it was observed the opposite in the soils of "Imperfectly drained".

  • PDF

Natural Baseline Groundwater Quality in Shingwang-myeon and Heunghae-eup, Pohang, Korea (포항시 신광면 및 흥해읍 일대 지하수의 배경수질 연구)

  • Lee, Hyun A;Lee, Hyunjoo;Kwon, Eunhye;Park, Jonghoon;Woo, Nam C.
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.469-483
    • /
    • 2020
  • The results of long-term groundwater level and quality monitoring can be used not only as the basic data for evaluating the impact of various disasters including climate change and establishing responses, but also as key data for predicting and managing geological disasters such as earthquakes. Some countries use groundwater level and quality monitoring for researches to predict earthquakes and to assess the impacts of the earthquake disaster. However, a few cases in Korea report on individual groundwater quality factors (i.e., dissolved ions) observed before and after the earthquakes, being different from other countries. To establish the abnormality criteria for groundwater quality in Pohang, groundwater samples were collected and analyzed five times from 14 agricultural or private wells existing in Shingwang-myeon and Heunghae-eup. As a result of the analysis, it was found that Ca2+ was the dominant cation in Shingwang-myeon, while Na+ was the dominant cation in Heunghae-eup. The elevated NO3- concentration in Shingwang-myeon is contributed to the agricultural activity in the area. A high concentration of Fe was detected in a well on Heunghae-eup; the concentration exceeded the drinking water standard by nearly 100 times. Relatively higher dissolved ions were observed in the groundwater of Heunghae-eup, and it is considered as the result of the flow velocity difference and water-rock reaction accompanying the difference in bedrock and sediment characteristics. The groundwater of Shingwang-myeon appeared to be most affected by the weathering of granite and silicates, while that of Heunghae-eup was mainly affected by the weathering of silicates and carbonate. The background concentrations (baselines) of groundwater Shingwang-myeon and Heunghae-eup was identified through the survey; however, the continuous monitoring is required to monitor the possible changes and the repeatability of seasonal variation.

Characteristics of a Reclaimed Tidal Soil for Effective Resalization at Saemangum and Youngsan-River

  • Chung, Doug-Young;Kim, Hyejin;Park, Misuk;Lee, Sang-Eun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.6
    • /
    • pp.1222-1229
    • /
    • 2012
  • The total area of a reclaimed tidal soil distributed on the south-west coast is approximately 156,600 ha, and the soil contains high contents of sand and silt as well as highly saline. Most of the reclaimed tidal soils are used as a paddy due to bad permeability and high groundwater table, resulting in easy accumulation of salts on the soil surface by capillary rise. Therefore, resalinization may occur because of rise of groundwater table after desalinization. The researches related to the reclaimed tidal soil mainly focused on desalinazation while most of the researches completed were limited to yields of crop based on desalinazation. pH of old reclaimed tidal soil is neutral or less than 7 while that of newly developed reclaimed tidal soils is greater than 7, that cause N-fertilizer to be volatile as ammonia. Thus, the physical and chemical properties should be investigated to be used as an arable upland instead of a paddy soil due to change in government policy. We need to develop measures to make soils grow crops normally by identifying problems related to reclaimed tidal soils.

A Study on Soil Slope Stability Design Considering Seepage Analysis (침투해석을 고려한 비탈면 설계에 대한 연구)

  • Kim, You-Seong;Kim, Jae-Hong;Lee, Jin-Kwang;Kim, Seong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.1
    • /
    • pp.135-147
    • /
    • 2013
  • Most of slope failures are triggered by heavy rainfall during rainy season. If the rain keeps on for the season, the water content of the ground increases and its matric suction decrease, and then the safety factor of soil slope gets lower. The change of water table level for soil slope stability dose not describe the behavior of the soil slope in real situation, hence it may be necessary to modify the design standard for slope stability in association with rain infiltration. For correct design, economical construction, and maintenance of a soil slope, unsaturated flow analysis is needed for estimation of slope instability regarding water infiltration and soil behavior on unsaturated soil slopes. The entire soil slope cannot be saturated by prolonged rainfall and wetting band depth (saturated zone) just deepens from slope surface, hence the cause of the shallow surface slide is the wetting band depth depending on rainfall duration and intensity. Therefore, the paper presents the differences between theoretical equation and numerical analysis for wetting band depth on soil surface and its safety factor, and compares the slope stability obtained from unsaturated flow analysis with that obtained from conventional slope stability analysis.

Improvement of Infiltration Performance Measurement in BTL (Build-Transfer-Lease) Sewer Rehabilitation Projects - Focusing on Jeju Special Self-Governing Province - (하수관거정비 임대형민자사업에 있어 침입수 성과지표의 개선에 관한 연구 - 제주특별자치도를 중심으로 -)

  • Ko, Young-Nam;Lee, Dong Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.1133-1143
    • /
    • 2016
  • The purpose of this study is to improve project performance analysis indicators for BTL sewer rehabilitation projects. Among the assessment indicators for BTL sewer rehabilitation projects, an infiltration assessment indicator is given a high score of 17.5 points as a single assessment item. This infiltration assessment indicator is assessed focusing on the amount of infiltration, and presently calculated according to 'Nighttime Domestic Flow Evaluation' method. However, this assessment indicator's failure to reflect the geological features of Jeju region is emerging as a problem in the operational stage. Thus, this study intended to compare and analyze the calculation result depending on the assessment indicators and the actual amount of infiltration, centering on Jeju region. To this end, this study analyzed the amount of infiltration in five areas of Jeju Province calculated according to 'Nighttime Domestic Flow Evaluation' method. Also, a complete enumeration survey was carried out about the conditions for actual infiltration occurrence. According to the results of this survey, ground water level is distributed lower than the level of sewer pipes. The results of a sewer pipe function test show there was no infiltration occurrence caused by sewer pipe defect. So, it is concluded that 'Nighttime Domestic Flow Evaluation' method, which is utilized for the current assessment indicator, is not appropriate to apply to Jeju region, and it is thought that there is a need to establish infiltration criteria specialized for Jeju region.

Comparison of Hydrologic Soil Groups with Classification Method (분류방법에 따른 수문학적 토양유형 비교)

  • Jung, Kang-Ho;Hur, Seung-Oh;Sonn, Yeon-Kyu;Park, Chan-Won;Ha, Sang-Keun;Kim, Nam-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.97-105
    • /
    • 2007
  • 수문학적 토양유형은 복잡하게 세분되어 있는 토양의 종류를 수문학적인 목적에 따라 단순화하기 위해 만든 것으로 미농무성 토양보전국에서 고안한 개념이다. 우리나라 토양을 이 방법으로 구분하고자 하는 몇번의 시도가 있으며 그 중 대표적인 것이 정 등(1995)이 분류한 수문학적 토양군이다. 이는 토양의 침투 투수특성에 대한 실측자료가 부족한 우리나라의 실정을 감안하여 토성속(textural family), 배수등급(drainage class), 불투수층(impermeable layer), 투수성(permeability)의 네가지 토양특성을 분류특성으로 하여 각각에 1-4점 범위로 점수를 매긴 후 합산한 점수를 기준으로 수문학적 토양유형을 분류하는 것이다. 최근에는 토양의 한계침투속도에 따라 수문학적 토양유형을 분류하고자 하는 시도가 있으며 본 논문에서는 새로운 방법으로 분류할 때 기존의 방법과 어떠한 차이가 있는지 비교하고자 하였다. 정 등(1995)의 분류방법은 개념상 몇가지 문제점을 안고 있다. 먼저 토양의 수리특성은 같은 토성속이라 하여도 토양생성 과정과 토지이용 방법에 따라 그 차이가 매우 큼에도 불구하고 이에 대해 고려하지 못하였으며 다음으로 지표유거가 많아 배수가 양호한 토양의 강우 유출을 과소평가한다. 또한 얕은 토심에 존재하는 불투수층이 존재하는 경우 토양의 수리특성에 관계없이 적은 양의 강우에도 유출이 발생하므로 별도의 제한인자로 간주하여야 한다. 토양의 한계 침투속도를 이용한 분류방법은 이러한 문제점을 상당 부분 개선할 수 있다. 토양의 한계침투속도를 산정하기 위해 현장에서 지표 한계침투속도와 투수속도를 측정하였으며 이 자료를 확장하여 해석하기 위해 입자특성을 이용한 Pedo Transfer Function을 개발하였다. 토심 50 cm 포화시 토양 투수성을 한계 침투속도로 가정하였으며 50 cm 이내에 암반층과 지하수위가 존재할 경우 투수성에 관계없이 D유형으로 분류하였다. 새로운 방법으로 분류한 결과 기존의 분류와 몇가지 차이점이 발견되었다. 가장 큰 차이는 대부분의 논토양이 느린 한계침투속도의 영향으로 D유형에 속한 것이다. 산림토양과 밭토양은 기존 방법과 마찬가지로 A, B유형이 많았으며 암반층을 고려하기 전에는 기존 분류에 비해 강우 유출 가능성이 적은 쪽으로 평가되었다. 그러나 암반층이 존재하는 토양을 고려한 결과 A 또는 B 유형에 속하던 상당수의 산림토양이 새로운 분류에서 D유형으로 분류되었다. 지표 유거가 많아 배수등급이 매우양호로 분류되던 토양은 정 등(1995)의 분류와 비교하여 대부분 강우 유출 가능성이 큰 쪽으로 조정되었다. 새로운 수문학적 토양유형을 이용할 경우 낮은 토심에서 암반층이 발견되는 산림토양이 분포한 유역이나 산림, 밭 등에 식질 토양이 많이 분포하는 유역에서는 기존의 방법을 이용하는 것보다 강우 유출량이 높게 평가될 것으로 판단된다. 앞으로 강우 유출량 실측자료와의 비교를 통해 지속적인 보정을 하여야 할 것이며 특히 불투수층의 존재시 일괄적으로 D유형으로 분류된 토양의 경우 깊이에 따라 C 또는 D 유형으로 세분하여 조정할 필요가 있다.

  • PDF

Evaluation of Land Subsidence Risk Depending on Grain Size and Verification using Numerical Analysis (지반입도조건에 따른 지반함몰 가능성 평가 및 수치해석적 검증)

  • Lee, Jong-Hyun;Jin, Hyun-Sik;Baek, Yong;Yoon, Hyeong-Suk
    • The Journal of Engineering Geology
    • /
    • v.27 no.2
    • /
    • pp.133-141
    • /
    • 2017
  • In this study, filter conditions by difference in grading between core material and filter material used for dam construction was applied as evaluation condition for surrounding ground conditions near excavation site in a bid to identify the risk of land subsidence resulting from the erosion of soil particles. To that end, filter conditions proposed for the test was evaluated and the risk of land subsidence depending on grain size conditions was also evaluated using the filter conditions developed by COE. Consequently, evaluation diagram that can be used to determine the risk of land subsidence using grain size conditions obtained from ground investigation data was developed, which is expected to help evaluate the possibility of land subsidence depending on changes to the stratum. To simulate the particle flow process, PFC3D program was used. It's not only intended to determine the land subsidence pattern caused by falling ground water level but also predict and evaluate the land subsidence caused by soil erosion using grain size condition which can be verified by numerical analysis approach.

Analyzing the effect of LID(Low Impact Development) using the CAT(Catchment hydrologic cycle Assessment Tool) (CAT을 이용한 LID(Low Impact Development) 효과 분석)

  • Jang, Cheol-Hee;Kim, Hyeon-Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.278-278
    • /
    • 2012
  • 최근 녹색도시를 지향하면서 도시 내에서의 물의 순환에 대한 관심이 높아지고 있으며 도시계획 단계에서부터 물의 순환을 고려하려는 시도가 이루어지고 있다. 국토해양부, 환경부, 소방방재청 및 지방자치단체들은 법령, 기준, 지침 및 조례 등을 제정하여 물순환을 도시개발 이전의 상태가 될 수 있도록 시설 설치를 유도하고 있다. 그러나, 개별시설들의 조합이 유역규모의 물순환에 미치는 영향 평가는 이루어지고 있지 못한 실정이다. 종래에는 홍수저감을 목적으로 홍수저류지와 침투시설에 대하여 설계하고 시공을 하였으나 장기적인 관점에서 LID 시설의 효과를 평가하여 도시 계획 단계에서 반영하지는 못하였다. 그리고 이들 개별 LID 시설(침투, 저류 등)에 대한 단위 시설의 규모 설계에 그치고 있어 개선 시설이 다중으로 조합되어 분산 계획되었을 경우, 유역 규모에서 물순환의 긍정적인 변화를 판단하기는 어려운 형편이다. 도시지역에서의 LID(Low Impact Development) 효과 분석과 연계된 유역 물순환 해석을 위하여 독일, 호주 및 미국에서는 STORM, Urban Developer, SUSTAIN(System for Urban Stromwater Treatment, and Analysis INtegratration) 및 SWMM LID(Storm Wastewater Management Model LID) 등의 모형을 출시하고 실무에 적용하고 있다. 그러나, 해외에서 개발된 기술은 국내의 유역 환경을 충분히 반영하기 어렵다. 저수지 혹은 하천에서의 취수 등과 같이 국내의 복잡한 물순환 형태를 반영하는데 한계가 있으며, 기존의 물순환 해석모형에 의한 LID 시설을 계획하는 방법은 홍수저감에 국한되어 있고, 하천 유량이나 지하수위 측정 자료가 부족한 대상지역에 대한 장기적인 유역 물순환 및 도시 개발과 같은 토지이용 변화가 물순환에 미치는 영향을 해석하는데 있어 제한이 있고, 개별적으로 설치된 LID 시설들이 유역의 물순환을 개선하는 효과를 종합적, 정량적으로 구현하는데 한계가 있다. 본 연구에서는 도시 개발 지역의 장기간에 걸친 물순환의 변화를 예측하고 물순환을 개선시키는 대안 시설의 효과를 사전에 평가하는 것을 목표로 김현준 등(한국건설기술연구원, 2011)이 개발한 유역 물순환 해석 모형인 CAT(Catchment hydrologic cycle Assessment Tool)을 이용하였다. 특히, CAT은 사용자의 목적에 맞는 다양한 물순환 개선시설(침투시설, 저류지, 습지, 빗물저장 시설, 리사이클 및 외부급수 등)의 구현 및 모의가 가능하도록 개발되었다. 대상유역으로는 경기도 Y지구를 선정하였으며 도시개발 시나리오(전원도시 및 산업도시 등)에 따른 LID 효과 분석을 실시하였다. 대상지역에 대한 도시유형별 개발계획에 따른 개발 전 후 물순환 변화량 분석 및 LID 시설 계획에 의한 물순환 개선효과를 살펴보면 1998년부터 2007년까지의 평균 강우량을 1,271mm라고 할 때 산업도시의 경우 도시 개발 전의 증발산, 직접유출 및 기저유출은 각각 53%, 29%, 19%로 나타났으며 도시 개발 후 35%, 54%, 12%로 직접유출이 개발 전에 비해 86%나 증가하여 개발에 따른 영향이 큰 것으로 나타났다. 따라서, 이러한 개발에 따른 영향을 최소화하기 위하여 LID 시설을 계획하여 효과를 분석한 결과 증발산, 직접유출, 기저유출이 44%, 34%, 13%로 나타나 도시 개발 후의 왜곡된 물순환 체계가 개발전의 수준과 근접하게 나타나 LID 시설의 긍정적인 효과를 검토할 수 있었다. 이상에서와 같이 CAT 모형을 사용하여 도시유역의 물순환 체계를 진단하고, LID 시설의 효과를 평가할 수 있게 됨으로써 향후 도시유역에 대한 물순환 정상화를 실현하기 위한 정책 수립에 기초자료를 제공하고, 설계 실무에 활용될 수 있을 것이다.

  • PDF