• Title/Summary/Keyword: 기준탄

Search Result 178, Processing Time 0.024 seconds

Monitoring of residue PBDEs level in human milk and fish & shellfish samples collected from Korea (한국인 모유 및 어패류 중 PBDEs 잔류 레벨 모니터링)

  • Jang, Myungsu;Cha, Sujin;Kang, Younseok;Park, Jongsei
    • Analytical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.244-254
    • /
    • 2006
  • Flame retardants are added to prevent catching fire and to slow down the burning process. PBDEs are known to affect thyroid hormones and hormone disruption. The aim of this study was to propose a manual for determination of PBDEs, and investigate the accumulation of PBDEs(BDE-28, 47, 99, 100, 153, 154 and 183) in fish&shellfish and human milk samples. Pre-treatment for PBDEs determination, alkali digestion and L-L(Liquid-Liquid) extraction method could be applied to fish and shellfish. When Multi-layer column was used for cleaning up the sample, 50 mL of hexane and 100 mL of hexane:dichloromethane(9:1) solutions were used for pre- and post-elution, respectively. Activated-carbon column was optimized by a 100 mL of hexane:dichloromethane(3:1). The result of fish, highest concentration was detected in flatfish, 890 pg/g(wet weight). The other side, lowest concentration was detected in pollack, 40 pg/g(wet weight). The result of breast milk, PBDEs was detected 2,580 and 3,600 pg/g(lipid weight) from breast milk of Seoul and Juju, respectively. BDE-153 and 183 were not detected in all samples. There was no difference in PBDEs level was not difference between first and second delivery. In this study, we could find that PBDEs level in Korea is lower than other countries.

A Study on Reuse of Reclaimed Water in Jeonbuk Province (전북지역 하수처리수 재이용 방안 연구)

  • Cho, Changwoo;Kim, Jintae;Park, Jeongjae;Song, Juhoon;Lee, Miseon;Jeong, Juri;Ryou, Jaewoong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.237-245
    • /
    • 2017
  • This study was aimed at investigating effluent water quality and proposing reuse possibilities for 12 sewage treatment plants discharged more than $5,000m^3/day$ in order to recycle the sewage treatment plant effluent of Jeollabuk-do effectively. Additionally, a laboratory scale test for reprocessing water discharge was performed. Categories of reclaimed sewage water reuse were divided into 7 topics and analyzed a total of 28 items including 16 heavy metals based on water quality standard. As a results, color, BOD, TN, chloride and Electrical Conductivity (EC) exceeded reused water quality standard. In particular, color and TN exceeded in 8 and 5 sewage treatment plants, respectively. The value of chloride and EC were high in sewage treatment plants including the food and industrial wastewater. At 4 sewage treatment plants were possible to reuse without re-treatment. The laboratory scale test was conducted to SandFilter (SF)-Granular Activated Carbon (GAC)-MicroFiltraion (MF)-Reverse Osmosis (RO). Both the removal efficiencies and economic feasibility of total E. coli., color and Suspended Solid (SS) suited in case using the SF-GAC treatment method. The removal of chloride and EC had little effect in the case of SF-GAC-MF system, but RO showed over 90% of removal efficiency. After using SF-GAC process only, the concentration of $UV_{254}$ decreased sharply from 0.3651 /cm to 0.0306 /cm and it showed over 92% of removal efficiency rate. In conclusion, for the effective reuse of sewage discharged water, water quality and the surrounding terrain of treatment plants should be all taken into account. If it needed for the reprocessing, both the selection for treatment and economic combination treatment methods will have to be considered.

Development of an Economic Evaluation model for Coating System Based on Environmental Conditions of Power Generation Structure (발전구조물의 환경조건을 반영한 도장계 선정 경제성 평가 모델 개발)

  • Kim, In Tae;Lee, Su Young;An, Jin Hee;Kim, Chang Hak
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.77-85
    • /
    • 2020
  • Currently, life-cycle cost analysis methods are introduced to maintain large infrastructure facilities in Korea. However, there are not many cases in which maintenance models are applied that reflect conditions such as the location of a facility and its surroundings. In order to establish an appropriate maintenance strategy, a cost prediction, deterioration model, and a decision model reflecting uncertainty should be established. In this study, an economic analysis model was developed for long-term cost planning and management based on user decisions based on maintenance methods and judgment criteria for painting specifications applied to power generation structures. The performance of the paintwork was assessed through the paint deterioration test for the application of the economic analysis model, and the results of the economic analysis according to the applied paint specifications (Urethan, polysiloxane, fluorine) were verified by applying the proposed economic analysis model. In this study, it is believed that the selection of the repair cycle and evaluation methods applied with the development model rather than the performance of the painting can be expected to be used as basic data for the maintenance cycle, even if it is not limited to the painting.

A Case Study on Chlorine Dioxide Usage at a Conventional Water Treatment Plant (기존 정수장 이산화염소 시범도입 사례연구)

  • Lee, Song-Hee;Lee, Byung-Doo;Kim, Jin-Keun;Seog, Kwon-Soo;Lee, Joung-Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.115-119
    • /
    • 2005
  • As the regulations on DBPs are tightened, many water treatment plants (WTPs) in Korea have already introduced or will introduce enhanced coagulation, alternative disinfectants and advanced treatments such as ozonization and granular activated carbon to improve drinking water qualify. After a phenol leakage accident at the Nakdong-River in 1991, 26 WIPs in Korea introduced carbon dioxide generators, but there has been no accumulation of significant operating data. This research summarizes things that should be considered for the introduction of carbon dioxide disinfection process to WTPs based on one year operation data from A WTP that has had high concentration of DBP during a specific period in the summer. The removal efficiency of DBP was $30{\sim}40%$, but those of 2-MIB, Geosmin were less than 10%. The generation rate of $ClO_2$ by-products such as chlorite and chlorate were $70{\sim}100%$ of input dosage, but the ratios increased over time. At the same time, strong chlorine odors may be produced in the distribution system when $ClO_2$ was used with $Cl_2$ as a result of reaction between the chlorite and residual chlorine.

Status and Perspective of Biomass Co-firing to Pulverized Coal Power Plants (미분탄 석탄화력발전에서의 바이오매스 혼소 동향 및 전망)

  • Yang, Won
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.525-529
    • /
    • 2016
  • Biomass co-firing to existing thermal power plants is one of the most economical and efficient way to reduce $CO_2$ emission from the plant. There are several methods of co-firing and it can be categorized into (1) Parallel co-firing, (2) Indirect co-firing, and (3) Direct co-firing. Parallel co-firing is the most expensive way to high-ratio co-firing because it requires biomass dedicated boiler. Direct co-firing is widely used because it does not need high capital cost compared with the other two methods. Regarding the direct co-firing, it can be classified into three methods- Method 1 does not need retrofit of the facilities because it uses existing coal mills for pulverizing biomass fuels. In this case high-ratio co-firing cannot be achieved because of poor grindability of biomass fuels. Method 2 needs biomass-dedicated mills and revision of fuel streams for the combustion system, and Method 3 needs additional retrofit of the boiler as well as biomass mills. It can achieve highest share of the biomass co-firing compared with other two methods. In Korea, many coal power plants have been adopting Method 1 for coping with RPS(Renewable portfolio standards). Higher co-firing ratio (> 5% thermal share) has not been considered in Korean power plants due to policy of limitation in biomass co-firing for securing REC(Renewable Energy Certificate). On the other hand, higher-share co-firing of biomass is widely used in Europe and US using biomass dedicated mills, following their policy to enhance utilization of renewable energy in those countries. Technical problems which can be caused by increasing share of the biomass in coal power plants are summarized and discussed in this report. $CO_2$ abatement will become more and more critical issues for coal power plants since Paris agreement(2015) and demand of higher share of biomass in the coal power plants will be rapidly increased in Korea as well. Torrefaction of the biomass can be one of the best options because torrefied biomass has higher heating value and grindability than other biomass fuels. Perspective of the biomass torrefaction for co-firing is discussed, and economic feasibility of biomass torrefaction will be crucial for implementation of this technology.

Fluoride and nitrate removal by electro-coagulation for decentralized water treatment plants (전기응집을 이용한 소규모 수도시설의 불소 및 질산성질소 이온의 제거)

  • Han, Song-Hee;Chang, In-Soung;Back, Soun-Ok;Joung, Seun-Young;Lee, Cheol-Ku
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11a
    • /
    • pp.115-116
    • /
    • 2010
  • 광역상수도의 경우 수자원공사 및 지방상수도 사업자들에 의해 전문적으로 수질을 관리하고 음용수를 보급하고 있으나 소규모 수도시설의 경우 전문능력을 갖춘 관리자가 아닌 마을의 대표자가 맡아 관리함에 따라 안정성 및 유지관리의 어려움이 자주 제기되고 있다.[1] 또한 소규모 수도시설의 경우 취수원으로 지하수나 계곡수를 이용하여 여과나 염소소독을 거쳐 음용수로 이용함에 따라 중금속 및 무기이온 등 각종 오염물질이 효과적으로 제거되지 않아 이를 사용하는 주민들이 불편함을 겪고 있는 실정이다. 환경부의 법정 수질 검사에 따르면 부적합 판정을 받은 곳의 대부분은 마을상수도와 소규모 급수시설인 것으로 나타났으며 초과 항목으로는 무기이온 중 특히 불소와 질산성질소 인 것으로 나타났다.[2] 이러한 문제점을 해결하고자 기존의 고도 정수처리 시설인 막여과, 오존처리, 활성탄 흡착 공정 등을[3-5] 적용하고 있으나 소규모 수도시설에 적용하기에는 유지관리, 규모, 경제적 측면 등 여러 한계점을 지니고 있다. 따라서 본 연구에서는 이러한 문제점을 해결하기 위한 방안으로 전기응집기술을 이용하여 음용수 수질기준을 초과하는 무기이온 중 불소와 질산성 질소를 제거하고자 하였다. 전기응집기술은 제거효율이 높고, 운전이 용이하며 부가적인 화학약품의 첨가가 불필요하다.[6,7] 또한 기존의 고도정수처리 기술에 비해 전기응집 공정은 처리효율과 경제적인 측면 모두를 만족시키고 있어 소규모 수도시설의 불소와 질산성질소를 효과적으로 제거할 수 있는 방안으로 판단된다. 본 연구에 사용된 실험장치는 직류전원공급장치 (DC power supply), 반응조, 전극으로 구성되어 있다. 직류전원공급장치는 최대전압 30 Volt, 최대 전류 30 Amper 까지 조절 가능하였으며 반응조의 크기는 14.5cm(w) ${\times}$ 9cm(L) ${\times}$ 22cm(H) 이고 실용적 1.5L이다. 반응조의 상부에는 전극이 고정될 수 있도록 0.5cm 간격의 홈을 만들어 제작 하였다. 전극은 가용성 전극인 알루미늄 (Al), 스테인레스스틸(SUS304)를 이용하였다. 이를 통해 전류밀도, 전극간격 등의 변수를 두어 최적의 전기응집 운전 조건을 파악하였으며 이는 소규모 수도시설의 수질개선 향상에 도움이 될 수 있을 것으로 판단된다.

  • PDF

Effect of Rate and Timing of Reseeding on Productivity and Nutritive Value of Forages in Forest Fire Burnt Pasture (산불 피해 목초지에서 보파량과 보파 시기가 초지의 생산성과 사료가치에 미치는 영향)

  • Lee, Joung Kyong;Yoon, Sei-Hyung;Lim, Young-Cheol;Ji, Hee-Chung;Kim, Ki-Young;Choi, Gi-Jun;Kim, Won-Ho;Kim, Jong-Geun;Park, Hyung-Soo;Tandang, L. L.;Seo, Sung
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.28 no.3
    • /
    • pp.245-250
    • /
    • 2008
  • On April 4 to 6, 2005, there was a huge fire in Yangyang-gun, Kangwon-do, Korea, which burned over 250ha of forests and 246 buildings including 160 houses. The effects of reseeding rate and timing on productivity and nutritive value of forages in the forest fire burnt pasture in this study were investigated. The effect of reseeding could not be seen in the burnt pastures in terms of forage productivity and quality in short term but there was a long-term effect particularly with higher reseeding rates at later days after the fire on forage botanical composition. We concluded that forest fire brought reduction in pasture forage yield for a short period but it did not make a significant effect for a long term.

Issues and Directions of National Policy on Sports Facilities (정부의 체육진흥시설 정책의 과제)

  • Ko, Wi-Sug;Cho, Min-Heang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.291-299
    • /
    • 2018
  • The purpose of this study was to review the government's policy on the enhancement of sports facilities for community residents regarding the lack of knowledge surrounding the infrastructure of sports facilities. The government has invested approximately 2.4 trillion won to establish 220 community sports centers, 385 billion won for 194 multi-purpose indoor centers, and 1.3 trillion won for rebuilding 1,870 school outdoor fields. On the other hand, there are problems with the link between the crumb rubber infill on sports fields and cancer, a lack of availability of indoor sports centers, and an increased federal budget deficit. It is the responsibility of government to plan and construct outdoor fields that are large enough to accommodate all people and allow them to play activities. In addition, the guidelines should ensure that the indoor space required for physical activities at each teaching station is large enough to accommodate all students in the class and handle two classes. The government should suggest the federal government guidelines based on a good understanding of the concept of infrastructure in sports facilities. The government also should make efforts to reduce the regulatory powers and provide the community with an autonomous right to plan and construct sports facilities.

A Study on Durability Improvement of Breech Block for 30mm Automatic Gun (30mm 자동포용 폐쇄기의 내구성 향상에 관한 연구)

  • Park, Young Min;Kim, Sung Hoon;Noh, Sang Wan;Kim, Sung Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.47-53
    • /
    • 2020
  • The purpose of this study was to increase product reliability by improving the durability of the breech block for a 30mm Automatic Gun. The breech block is a key component of a gun that functions as chambering, closing, and extracting. The breech block requires high reliability, which needs to be improved because cracks of a breech block can occur early in operation. Cause analysis confirmed that the crack is caused by repeated impacts. Therefore, the following improvement measures were studied, and the effects were demonstrated using a firing test. The energy of impact absorption was increased by changing the material, and the stress concentration was mitigated by increasing the value of R. In addition, the fatigue life was increased by adding Shot-peening, deleting chromium plating, and changing the forging method. The firing test did not show firing trouble for up to 5,000 rounds. The start timing of the crack was delayed, and the depth was small. Therefore, the improved product was more durable than the existing product. This study can be used as a useful reference when assessing the improvement of the durability of similar products, life study, and criteria for crack acceptance.

A Study on the CO2 Removal Efficiency with Aqueous MEA and Blended Solutions in a Vortex Tube Type Absorber (Vortex Tube 형 흡수장치에서 MEA와 혼합흡수용액을 이용한 CO2 제거 효율 고찰)

  • Ryu, Woo-Jung;Han, Keun-Hee;Choi, Won-Kil;Lee, Jong-Sub;Park, So-Jin
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.795-800
    • /
    • 2009
  • In this study, the $CO_2$ removal characteristics of the Vortex tube type absorbtion apparatus were investigated to enhance the compactness of $CO_2$ absorption process and to reduce the amount of absorbing solution of the $CO_2$ separation process. The Vortex tube with the diameter of 17 mm and the length of 250mm was introduced in the experimental apparatus to treat $20Nm^3/hr$ of $CO_2$ containing flue gas. The flue gases for experiments containing 11~13 vol% of $CO_2$ were supplied from the coal-firing CFBC power plant with 12 ton/hr of steam producing capacity. The mixed solutions of 20 wt% of MEA as base solution with the adding solutions like HMDA, AMP and KOH were used as absorbents. The experiments were executed under the various conditions like the absorbing solution concentrations in the range of 20 to 50 wt%, the flow rate of $CO_2$ containing flue gases in the range of 6 to $15Nm^3/hr$ and the flow rate of absorbing solution in the range of 1.0 to 3.0 l/min. As a results, the $CO_2$ removal efficiency of mixed absorbent of 20 wt% of MEA with HMDA was remarkable. From this study, we concluded that the efficient separation of $CO_2$ from flue gases using the features of the Vortex tube type absorbing unit for gas/liquid contact and the separation of gas/liquid be possible. But more works are needed to increase the $CO_2$ removal efficiency of Vortex tube process.