• Title/Summary/Keyword: 기술 활용

Search Result 32,437, Processing Time 0.059 seconds

National Management Measures for Reducing Air Pollutant Emissions from Vessels Focusing on KCG Services (선박 대기오염물질 배출 현황 및 저감을 위한 국가 관리 대책 연구: 해양경찰 업무를 중심으로)

  • Lee, Seung-Hwan;Kang, Byoung-Yong;Jeong, Bong-Hun;Gu, Ja-Yeong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.2
    • /
    • pp.163-174
    • /
    • 2020
  • Particulate matter levels are rapidly increasing daily, and this can affect human health. Therefore, air pollutant emissions from sea vessels require management. This study evaluates the status of air pollutants, focusing on air pollutant emissions from the vessels of the Korea Coast Guard (KCG), and proposes national management measures to reduce emissions. According to a report recently released (2018) by the National Institute of Environmental Research (NIER), emissions from vessels constituted 6.4 % of the total domestic emissions, including 13.1 % NOx, 10.9 % SOx, and 9.6 % particulate matter (PM10/PM2.5). Among the rates of pollutant emission from vessels, the emission rates of domestic and overseas cargo vessels were the highest (50.6 %); the ratio of fishing boats was 42.6 %. With respect to jurisdictional sea area, 44.1 % of the emissions are from the south sea, including the Busan and Ulsan ports, and 24.8 % of the emissions are from the west sea, including the Gwangyang and Yeosu ports. The KCG inspects boarding lines to manage emission conditions and regulate air pollutant emissions, but it takes time and effort to operate various discharge devices and measure fuel oil standards. In addition, owing to busy ship schedules, inspection documents are limited in terms of management. Therefore, to reduce the air pollutant emissions of such vessels, regulations will be strengthened to check for air pollutants, and a monitoring system based on actual field data using KCG patrol ships will be established, for each sea area, to manage the emissions of such vessels. Furthermore, there is a need for technological development and institutional support for the introduction of environmentally friendly vessels.

A Study on Improvement of Test Method of Nuclear Power Plant ESF ACS by applying Regulatory Guide 1.52 (Rev.3) (Reg. Guide 1.52(Rev.3)를 적용한 원전 ESF 공기정화계통 성능시험법 개선 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kae-Woo;Park, Jeong-Seo;Cho, Byoung-Ho;Yoo, Byeang-Jea;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.311-318
    • /
    • 2010
  • U. S. NRC Regulation Guide 1.52 regulating ESF ACS in nuclear power plants has been revised to revision 3. To apply reduction of operability test time, allowance of alternative challenge agents for in-place leak test of HEPA filters, and upgrade of Methyl Iodide penetration acceptance criterion in activated carbon performance test suggested in Reg. Guide 1.52(Rev.3) on Yonggwang units 5 and 6 ESF ACSes, technical feasibility study was carried out with on-site experiments as well as experiments with a lab-scale model. It was confirmed that the moisture in the system returned to the level before the test in 1 or 4 days even though the moisture was removed during the operability test lasting more than 10 hours. Therefore, it is appropriate to perform monthly operability test in 15 minutes just long enough to check the operability of equipment. To change challenge material for in-place HEPA filter leak test, size of aerosol, production rate, and leak detection capability were compared for DOP and PAO. It was concluded that PAO can be substituted for DOP in nuclear power plants. The upgrade of Methyl Iodide penetration acceptance criterion from 0.175 % to 0.5 % in active carbon filter bed deeper than 4 inches was to conform to the change of activated carbon performance test method to ASTM D3803(1989). It was confirmed that Methyl Iodide penetration acceptance criterion of 0.5 % under $30^{\circ}C$, relative humidity 95 % condition was conservatively good enough for testing performance of active carbon insitu. The licence change of Yonggwang units 5 and 6 has been completed based on this study.

A Study on the Marketplace Models for Korean Animation Content Foreign Sales (국산 애니메이션 콘텐츠 해외 판매를 위한 마켓플레이스 모델 연구)

  • Han, Sang-Gyun
    • Cartoon and Animation Studies
    • /
    • s.44
    • /
    • pp.333-361
    • /
    • 2016
  • In general, content business companies include animation industry can have benefits, which they have higher incomes when they obtain wider markets. Therefore, they pursue to have diverse windows for content distribution or to reach the foreign markets for dealing their content products with potential customers. It have the greatest value. They can re-invest the incomes to produce their new products, and they can enhance the international competitiveness of their next products. As the results, the companies can have more incomes and wider markets in next business, and it will be the effectiveness of the good cycle of the animation industry. Animation industry has being undergone of its structure changes, more economical chances and viewers' attitudes changes through the all over the industry because of the acceptance of new digital technology. To response the changes or have the new chances from the changes, they should to review the existing system and the law concerned with the animation business as well as having the diverse new plans for supporting the industry like a construction of the online marketplace of Korean animation. It would make the Korean animation companies to meet foreign customers easily by making lower the entrance barrier of the foreign markets. Current Korean government needs to estimate the value of the Korean animation accurately and objectively by concerning its surroundings to support efficiently. However, it is very difficult to estimate the value of the content rightly because of its' intangible and subjective matter. For this, they should analyze the all the data of the information of the Korean animation content by accumulate, open to the public and manage. So if the government makes online marketplace for the Korean animation, which all the Korean animation companies get in, it would be a solution of estimating the value of the Korean animation rightly. In addition, it will be used as the role of archive of the government to lead the industry successfully. As a point of the small size of the Korean animation companies, they are government dependable because of its low budget, so they strongly expect the government to do the right role as the unique knowledge distributor. Therefore, the Korean animation online marketplace would make not only big companies, but also small companies to have the chances to increase the value of their content in the global markets by themselves without economic burdens.

Usefulness of MRI 3D Image Reconstruction Techniques for the Diagnosis and Treatment of Femoral Acetabular Impingement Syndrome(Cam type) (대퇴 골두 충돌 증후군(Cam type)의 진단과 치료를 위한 자기공명 3D 영상 재구성 기법의 유용성)

  • Kwak, Yeong-Gon;Kim, Chong-Yeal;Cho, Yeong-Gi
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.313-321
    • /
    • 2015
  • To minimize CT examination for Hip FAI diagnosis and operation plan. also, whether the MRI 3D images can replace Hip Clock face image was evaluated when performing Hip FAI MRI by using additional 3D image. This study analyzed Hip MRI and 3D Hip CT images of 31 patients in this hospital. For the purpose of evaluating the images, one orthopedic surgeon and one radiology specialist reconstructed Clock face, at MR and CT modality, by superior 12 o'clock, labrum front 3 o'clock, and the other side 9 o'clock, centering on Hip joint articular transverse ligament 6 o'clock. Afterwards, by the Likert Scale 5 point scale (independent t-test p<0.005), this study evaluated the check-up of A. retinacular vessel, B. head neck junction at 11 o'clock, A. Epiphyseal line, B. Cam lesion at 12 o'clock, and Cam lesion, Posterior Cam lesion at 1,2,3 and 4 o'clock. As for the verification of reliability among observers, this study verified coincidence by Cohen's weighted Kappa verification. As a result of Likert scale for the purpose of qualitative evaluation about the image, 11 o'clock A. retinacular vessel MR average was $3.69{\pm}1.0$ and CT average was $2.8{\pm}0.78$. B. head neck juncton didn't have a difference between two observers (p <0.416). 12 o'clock A. Epiphyseal line MR average was $3.54{\pm}1.00$ and CT average was $4.5{\pm}0.62$(p<0.000). B. Cam lesion didn't have a difference between two observers (p <0.532). 1,2,3,4 Cam lesion and Posterior Cam lesion were not statistically significant (p <0.656, p <0.658). As a result of weighted Kappa verification, 11 o'clock A.retinacular vessel CT K value was 0.663 and the lowest conformity. As a result of coincidence evaluation on respective item, a very high result was drawn, and two observers showed high reliability.

A study on the implementation of Medical Telemetry systems using wireless public data network (무선공중망을 이용한 의료 정보 데이터 원격 모니터링 시스템에 관한 연구)

  • 이택규;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.278-283
    • /
    • 2000
  • As information communication technology developed we could check our blood pressure, pulsation electrocardiogram, SpO2 and blood test easily at home. To check our health at ordinary times is able though interlocking the house medical instrument with the wireless public data network This service will help the inconvenience to visit the hospital everytime and will save the individual's time and cost. In each house an organism data which is detected from the human body will be transmitted to the distance hospital and will be essentially applied through wireless public data network The medical information transmit system is utilized by wireless close range network It would transmit the obtained organism signal wirelessly from the personal device to the main center system in the hospital. Remote telemetry system is embodied by utilizing wireless media access protocol. The protocol is embodied by grafting CSMA/CA(Carrier Sense Multiple Access with Collision Avoidance) protocol falling mode which is standards from IEEE 802.11. Among the house care telemetry system which could measure blood pressure, pulsation, electrocardiogram, SpO2 the study embodies the ECC(electrocardiograph) measure part. It within the ECC function into the movable device and add 900㎒ band wireless public data interface. Then the aged, the patients even anyone in the house could obtain ECG and keep, record the data. It would be essential to control those who had a health-examination heart diseases or more complicated heart diseases and to observe the latent heart disease patient continuously. To embody the medical information transmit system which is based on wireless network. It would transmit the ECG data among the organism signal data which would be utilized by wireless network modem and NCL(Native Control Language) protocol to contact through wireless network Through the SCR(Standard Context Routing) protocol in the network it will be connected to the wired host computer. The computer will check the recorded individual information and the obtained ECC data then send the correspond examination to the movable device. The study suggests the medical transmit system model utilized by the wireless public data network.

  • PDF

Feasibility Study on Double Path Capacitive Deionization Process for Advanced Wastewater Treatment (이단유로 축전식 탈염공정의 하수고도처리 적용가능성 평가)

  • Cha, Jaehwan;Shin, Kyung-Sook;Lee, Jung-Chul;Park, Seung-Kook;Park, Nam-Su;Song, Eui-Yeol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.295-302
    • /
    • 2014
  • This study demonstrates a double-path CDI as an alternative of advanced wastewater treatment process. While the CDI typically consists of many pairs of electrodes connected in parallel, the new double-path CDI is designed to have series flow path by dividing the module into two stages. The CFD model showed that the double-path had uniform flow distribution with higher velocity and less dead zone compared with the single-path. However, the double-path was predicted to have higher pressure drop(0.7 bar) compared the single-path (0.4 bar). From the unit cell test, the highest TDS removal efficiencies of single- and double-path were up to 88% and 91%, respectively. The rate of increase in pressure drop with an increase of flow rate was higher in double-path than single-path. At 70 mL/min of flow rate, the pressure drop of double-path was 1.67 bar, which was two times higher than single-path. When the electrode spacing was increased from 100 to $200{\mu}m$, the pressure drop of double-path decreased from 1.67 to 0.87 bar, while there was little difference in TDS removal. When proto type double-path CDI was operated using sewage water, TDS, $NH_4{^+}$-N, $NO_3{^-}$-N and $PO_4{^{3-}}$-P removal efficiencies were up to 78%, 50%, 93% and 50%, respectively.

Manufacture of Daily Check Device and Efficiency Evaluation for Daily Q.A (일일 정도관리를 위한 Daily Check Device의 제작 및 효율성 평가)

  • Kim Chan-Yong;Jae Young-Wan;Park Heung-Deuk;Lee Jae-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.105-111
    • /
    • 2005
  • Purpose : Daily Q.A is the important step which must be preceded in a radiation treatment. Specially, radiation output measurement and laser alignment, SSD indicator related to a patient set-up recurrence must be confirmed for a reasonable radiation treatment. Daily Q.A proceeds correctness and a prompt way, and needs an objective measurement basis. Manufacture of the device which can facilitate confirmation of output measurement and appliances check at one time was requested. Materials and Methods : Produced the phantom formal daily check device which can confirm a lot of appliances check (output measurement and laser alignment. field size, SSD indicator) with one time of set up at a time, and measurement observed a linear accelerator (4 machine) for four months and evaluated efficiency. Results : We were able to confirm an laser alignment, field size, SSD indicator check at the same time, and out put measurement was possible with the same set up, so daily Q.A time was reduced, and we were able to confirm an objective basis about each item measurement. As a result of having measured for four months, output measurement within ${\pm}2%$, and measured laser alignment, field size, SSD indicator in range within ${\pm}1mm$. Conclusion : We can enforce output measurement and appliances check conveniently, and time was reduced and was able to raise efficiency of business. We were able to bring a cost reduction by substitution expensive commercialized equipment. Further It is necessary to makes a product as strong and slight materials, and improve convenience of use.

  • PDF

A study on the correlation between Sound Characteristic and Sasang Constitution by Laryngograph, EGG (Laryngograph와 EGG를 이용한 음향특성(音響特性)과 사상체질간(四象體質間)의 상관성(相關性) 연구(硏究))

  • Kim, Sun-hyung;Shin, Mi-ran;Kim, Dal-rae;Kwon, Ki-rok
    • Journal of Sasang Constitutional Medicine
    • /
    • v.12 no.1
    • /
    • pp.144-156
    • /
    • 2000
  • Purpose of this study is to help classifying Sasang Constitution through correlation with Larynx waveform. This study was done it under the suppose that Sasang Constitution would be correlation with Larynx waveform. The following result were obtained about correlation between Erectroglottograph waveform and Sasang Constitution by analysis EGG program. 1. Taeumin was lower than Soyangin in Open Std Deviation, Contact Std Deviation of male/a/(0.5sec) 2. Soeyangin was high compared with the others in Pitch range of maie/a/(2.5sec) 3. Taeumin was higher than Soeumin in Pitch range, Soeyangin in pitch Maximum, and the others in Pitch Std Deviation of female/e/(0.5sec) 4. Taeumin was higher than Soeumin in Contact Maximum and lower than Soeumin in Contact Maximum of female/a/(2.5sec) 5. There was no significantly difference in male/e/(0.5sec), male/e/(2.5sce), female/a/(0.5sec), female/e/(2.5sec) 6. The percent of correctly classified in Soeoumin and Taeumin was high in CART Algolism. The risk estimate of Soyangin was relatively high. The study may be use on of the method to make objective diagnosis in Sasang constitution.

  • PDF

A Study on the Stability and Sludge Energy Efficiency Evaluation of Torrefied Wood Flour Natural Material Based Coagulant (반탄화목분 천연재료 혼합응집제의 안정성 및 슬러지 에너지화 가능성 평가에 관한 연구)

  • PARK, Hae Keum;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.271-282
    • /
    • 2020
  • Sewage treatment plants are social infrastructure of cities. The sewage distribution rate in Korea is reaching 94% based on the sewage statistics based in the year of 2017. In Korean sewage treatment plants, use of PAC (Poly Aluminum Chloride) accounts for 58%. It contains a large amount of impurities (heavy metal) according to the quality standards, however, there have been insufficient efforts to reinforce the standards or technically improve the quality, which resulted in secondary pollution problems from injecting excessive coagulant. Also, the increase in the use of chemicals is leading to the increases in the annual amount of sewage sludge generated in 2017 and the need to reuse sludge. As such, this study aims to verify the possibility of reusing sludge by evaluating the stability of heavy metals based on the injection of coagulant mixture during water treatment which uses the torrefield wood powder and natural materials, and evaluating the sedimentation and heating value of sewage sludge. As a result of analyzing heavy metals (Cr, Fe, Zn, Cu, Cd, As, Pb, and Ni) from the coagulant mixture and PAC (10%), Cr, Cd, Pb, Ni, and Hg were not detected. As for Zn, while its concentration notified in the quality standards for drinking water is 3 mg/L, only a small amount of 0.007 mg/L was detected in the coagulant mixture. Maximum amounts of over double amounts of Fe, Cu, and As were found with PAC (10%) compared to the coagulant mixture. Also, an analysis of sludge sedimentation found that the coagulant mixture showed a better performance of up to double the speed of the conventional coagulant, PAC (10%). The dry-basis lower heating value of sewage sludge produced by injecting the coagulant mixture was 3,378 kcal/kg, while that of sewage sludge generated due to PAC (10%) was 3,171 kcal/kg; although both coagulants met the requirements to be used as auxiliary fuel at thermal power plants, the coagulant mixture developed in this study could secure heating values 200 kal/kg higher than the counterpart. Therefore, utilization of the coagulant mixture for water treatment rather than PAC (10%) is expected to be more environmentally stable and effective, as it helps generating sludge with better stability against heavy metals, having a faster sludge sedimentation, and higher heating value.

Physicochemical characteristics of garlic (Allium sativum L.) shoots from different areas in Namhae (남해지역 마늘종의 이화학적 특성)

  • Yoon, Hwan-Sik;Kang, Min-Jung;Hwang, Cho-Rong;Sim, Hye-Jin;Kim, Gyeong-Min;Shin, Jung-Hye
    • Food Science and Preservation
    • /
    • v.21 no.3
    • /
    • pp.321-327
    • /
    • 2014
  • This paper introduces the physicochemical characteristics of garlic shoots investigated in the 8 areas of Namhae, Gohyeon-myeon (GHM), Nam-myeon (NM), Samdong-myeon (SDM), Namhae-eup (NHE), Seo-myeon (SM), Seolcheon-myeon (SCM), Idong-myeon (IDM) and Changsoen-myeon (CSM). The moisture was $80.15{\pm}0.37{\sim}83.87{\pm}0.15g/100g$. The crude protein and lipid were $1.59{\pm}0.02{\sim}2.25{\pm}0.09g/100g$ and $0.35{\pm}0.01{\sim}0.48{\pm}0.03g/100g$, respectively. Ash was $0.65{\pm}0.03{\sim}0.71{\pm}0.03g/100g$. In addition, the total levels of phenol and flavonoid were searched as $33.02{\pm}1.78{\sim}58.41{\pm}1.08mg/100g$ and $11.60{\pm}3.36{\sim}23.95{\pm}2.04mg/100g$, respectively. The garlic shoots in IDM, where the highest total chlorophyll level detected as $170.58{\pm}1.04{\mu}g/g$ and in CSM, where the lowest total chlorophyll level investigated as $116.65{\pm}0.00{\mu}g/g$, were unveiled. The mineral elements (S, Ca, Fe, K, Mg, Na, Mn and Zn) were analyzed by ICP-OES, and K was the most highly contained mineral with $7257.0{\pm}87.9{\sim}10070.0{\pm}9.7mg/kg$. Significant feature of garlic shoots in IDM and NHE was that the total amounts of mineral were relatively higher than other regions as 21,143.5 mg/kg and 20,581.2 mg/kg, respectively. The cultivating regions were revealed as the one of important matters with the level of allicin ($78.03{\pm}6.15{\sim}203.43{\pm}18.47mg/kg$). In particular, the level of allicin of garlic raised in SDM ($203.43{\pm}18.47mg/kg$) was approximately 2.2~2.6 times higher than those in CSM ($92.86{\pm}8.70mg/kg$) and SCM ($78.03{\pm}6.15mg/kg$). The sulfur compounds content of diallyl trisulde was remarkably higher, especially the garlic shoots in IDM with $830.62{\pm}14.69{\sim}1281.10{\pm}27.71mg/kg$.