• Title/Summary/Keyword: 기본 부위

Search Result 295, Processing Time 0.023 seconds

Meningoencephalitis in Dachshund Dog with Canine Distemper Virus Infection: 1.5 T and 7.0 T MRI Findings (닥스훈트견의 바이러스성 뇌수막염에서 1.5T와 7T 자기공명영상을 이용한 진단 증례)

  • Kang, Min-Hee;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.755-759
    • /
    • 2010
  • A 6-year-old, intact female Dachshund was presented with generalized seizure for 2 days. Based on the neurologic and physical examinations, intracranial diseases were suspected. 1.5T and 7.0T magnetic resonance imaging (MRI) of the brain were taken. The MRI results revealed diffuse hyperintense lesions in the area of the diencephalon to the medulla oblongata in the T2-weighted images. Canine distemper virus-induced meningoencephalitis was confirmed by the result of RT-PCR of the cerebrospinal fluid (CSF). The dog was euthanized 7 days after diagnosis due to poor prognosis and clinical deterioration. Postmortem histopathologic examination was consistent with the MRI findings. This is the first case report using 1.5T and 7.0T MRI to compare the virus-induced intracranial lesions in meningoencephalitis.

Arthroscopic Technique of Partial Meniscectomy for Bucket Handle Tear of Medial Meniscus using Posteromedial Portal (내측 반월상 연골판 양동이형 파열의 후내측 도달법을 이용한 관절경적 부분 절제술 - 수술 수기 -)

  • Ahn, Jin-Hwan;Lee, Jong-Yoon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.1
    • /
    • pp.71-75
    • /
    • 2000
  • Purpose : To introduce arthroscopic partial meniscectomy fur bucket handle tear of medial meniscus using posteromedial portal, which is superior to arthroscopic partial meniscectomy using standard anterior portals commonly used. Method : After arthroscopic examination of the knee, we reduce the torn meniscus, advance the arthroscope into posteromedial compartment under arthroscopic visualization, we make posteromedial portal with reexamination of the compartment and perform arthroscopic partial meniscectomy. Conclusion : With the technique of arthroscopic partial meniscectomy using standard anterior portals, accurate partial meniscectomy can not be done because of inadequate visual field, associated meniscal injuries of posterior horn and cartilage lesion of posterior aspect of the medial femoral condyle can be missed, commonly posterior cruciate ligament can be injured and artificial damage to weight bearing surface of medial femoral condyle is possible. An arthroscopic partial meniscectomy using posteromedial portal is an excellent method fur bucket handle tear of medial meniscus.

  • PDF

Characteristics of p-Xylene Adsorption using Functionalized Mesoporous Silica (관능기화 메조포러스 실리카를 이용한 파라자일렌 흡착 특성)

  • Kim, Sang-Hyoun;Park, Jonghoon;Kang, Seok-Tae;Chung, Jae-Woo;Kim, Soo-Hong;Cho, Yunchul;Lee, Chae-Young
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.6
    • /
    • pp.27-31
    • /
    • 2012
  • This study was designed to examine the feasibility of functionalized mesoporous silica as the adsorbent for benzene, toluene, ethylbenzene, and xylene isomers (BTEX) in groundwater. p-Xylene was used as the model compound of BTEX. A series of functionalized mesoporous silica with MCM-41 type of structure was synthesized using a co-condensation method. Monoamine, triamine, nitrile, phenyl, and octyl groups were functionalized to the mesoporous silica structure. Adsorption sites for p-Xylene in a functionalized mesoporous silica were Si-O-Si covalent bond, the surfactant, and the functional group. Octyl-functionalized mesoporous silica with stearyltrimethylammonium chloride as a surfactant showed the highest adsorption ability. The maximum xylene adsorption capacity of the octyl-functionalized mesoporous silica with stearyltrimethylammonium chloride based on Langmuir model was 4.17 mmol/g on $20^{\circ}C$, which was 2.9 times higher than that of MCM-41.

Analysis of Multi-Mode Reflection and Transmission Coefficients of a Lamb Wave Across a Rectangular Notch (사각형 노치에 대한 램파의 다중 모드 반사와 투과 계수 해석)

  • Kim, Byung-Soo;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.3
    • /
    • pp.129-139
    • /
    • 2008
  • The purpose of the present work is to derive the reflection and transmission coefficients of $S_0\;and\;A_0$ mode Lamb waves in relation to the geometry of a rectangular notch when the waves propagate across the notch in an elastic plate. Firstly, the excitable modes of the Lamb wave were analyzed with respect to the plate thickness. The scattering phenomena were divided into three independent processes according to the boundary shape of the notch and the direction of the wave propagation. Linear equations for each process were derived with corresponding free or continuous boundary conditions to analyze the scattered waves. By the rule of linear superposition, the waves scattered at each process were summed for each mode. Then the steady-state reflection and transmission coefficients of the scattered waves were determined so that the difference of energy flux between the incident and the scattered waves would remain within 4%.

Condenser Characteristics of Dielectric Soil Moisture Sensor (유전율 토양 수분 쎈서의 콘덴서 특성)

  • Oh, Yong-Taeg;Eorn, Ki-Cheol;Jo, In-Sang;Shin, Jae-Sung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.1
    • /
    • pp.15-23
    • /
    • 2000
  • RC oscillation method was applied to study the condenser characteristics of two metal sticks insulated by vinyl tube and used in the dielectric constant determinations of most soils. Its capacitance as influenced by the contacted ambient materials was measured as relative capacitance of the sensor sticks compared with the standard one on the RC oscillation circuit. According to the equivalent circuit of the sensor stick set, the measured capacitance was composed of a basic capacitance connected in parallel with sensor stick capacitance, which was composed of lineally connected vinyl tube capacitances and the sensing part capacitance. The dielectric constant (U) of the contacted ambient moist soil located in the sensing part around the sticks interrelated with the other parameters as following equation. $$\frac{1}{C-B}=\frac{k}{U}+Z$$ where C is the output total relative capacitance, B is the hidden and fixed basic relative capacitance, k is a constant related with U, and Z is a constant for the insulating vinyl tube capacitances determined by its thickness and dielectric constant. The constant k is determined by the spacing and length of sensor sticks. The Z value is theoretically an invariable constant, but it may become considerably bigger than the determined in lab if air tube is formed on the surface of sensor sticks by some shocks on them after their installation in soil. Due to the unstability of lab Z value, it may be better to revise it after sensor stick's installation in soil and no shaking shocks should be applied on them.

  • PDF

Inhibitory Effects of ${\gamma}$-Aminobutyric Acid on the Contractility of Isolated Rat Vas Deferens (흰쥐의 적출 정관 수축성에 대한 ${\gamma}$-Aminobutyric Acid의 억제작용)

  • Ahn, Ki-Young;Kwon, Oh-Cheol;Ha, Jeoung-Hee;Lee, Kwang-Youn;Kim, Won-Joon
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.2
    • /
    • pp.382-395
    • /
    • 1992
  • GABA is an inhibitory neurotransmitter in central nervous system and produce sedative, antianxiety and muscle reaxing effects via $GABA_A$ receptor or $GABA_B$ receptor. Recently it is known that GABA is widely distributed throughout peripheral organs and may playa physiological role in certain organ. The vas deferens is innervated by species-difference. These study, therefore, was performed to investigate the mode and the mechanism of action of GABA on the norepiniphrine-, ATP- and electric stimulation-induced contraction of vas deferens of rat. Sprague-Dawley rats were sacrificed by cervical dislocation. The smooth muscle strips were isolated from the prostastic portion and were mounted in the isolated muscle bath. PSS in the bath was aerated with 95/5%-$O_2/CO_2$ at $33^{\circ}C$. Muscle tensions were measured by isometric tension transducer and were recorded by biological recording system. 1. GABA, muscimol, a $GAB_A$ agonist, and baclofen, a $GABA_B$ agonist inhibited the electric field stimulation(EFS, 0.2Hz, 1mSec, 80 V, monophasic square wave)-induced contraction with a rank order of potency of GABA greater than baclofen greater than muscimol. 2. The inhibitory effect of GABA was antagonized by delta aminovaleric acid(DAVA), a $GABA_B$ antagonist, but not by bicuculline, a $GABA_A$ mtagonist. 3. The inhibitory effect of baclofen was antagonized by DAVA, but the effect of muscimol was not antagonized by bicuculline. 4. Exogenous norepinephrine(NE) and ATP contracted muscle strip concentration dependently, but the effect of acetylcholine was negligible : and GABA did not affect the NE-and ATP-induced contractions. 5. GABA, baclofen and muscimol did not affect basal tone, and GABA did not affect the NE-and ATP-induced contractionsm 6. EFS-induced contraction was including 2 distinctable components. The first phasic component was inhibited by beta gamma-methylene ATP(mATP), a desensitizing agent of APT receptor and the second tonic component was reduced by pretreatment of reserpine(3 mg/Kg, IP). 7. GABA inhibited the EFS-induced contraction of reserpinized strips, but not the mATP-treated strips. These results suggest that in the prostatic portion of the rat vas deferens, adrenergic and purinergic neurotransmissions are exist, and GABA inhibits the release of ATP via presynaptic $GABA_B$ receptor on the excitatory neurons.

  • PDF

Analysis of CFT Beam-to-Column Connections with T-Stiffeners (T형 스티프너를 이용한 콘크리트 충전강관 기둥-보 접합부의 해석에 관한 연구)

  • Shin, Kyung Jae;Kim, Hyun Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.375-384
    • /
    • 2005
  • The goal of this paper is to understand the stress-transfer mechanism of concrete-filled tubular column to H-beam connections with external T-stiffener through the finite element method and to offer basic data for the design of T-stiffener. To identify the problems of previous test results, the same shapes of the full-scale test specimens were modeled for the finite element analysis. Results of the analysis were compared with the test results. Several stress and strain indices were used to understand the stress-transfer mechanism of connection with various T-stiffeners parameters. The models of analysis with different T-stiffener are grouped into TS, TSD, and TSH series. An alternative plan that decreases the stress concentration of beam flange to horizontal stiffener connection is proposed through the elasto-plastic finite element method. The basic design idea and minimum sizes of T-stiffener were proposed based on the various indices in relation to the connection details.

Core Temperature Evaluation in Different Body Parts in Patients Undergoing Laparoscope Surgery under Total Intravenous Anesthesia (전정맥 전신마취하(下) 복강경 수술환자의 부위별 심부체온의 변화 평가)

  • Hahm, Tae Soo;Kim, Won Ho;Kim, Nam Cho;Yoo, Je Bog
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.22 no.4
    • /
    • pp.379-386
    • /
    • 2015
  • Purpose: The trend of body temperature change during laparoscopic surgery and the most adequate site for monitoring temperature measurements have not been investigated thoroughly. In this study body temperature change during laparoscopic surgery was measured and measurements of the tympanic, esophageal, and nasopharyngeal core temperatures in surgical patients with total intravenous anesthesia were compared. Methods: From February to October 2013, 28 laparoscopic surgical patients were recruited from a tertiary hospital in Seoul. The patients' core temperature was measured 12 times at ten minute intervals from ten minutes after the beginning of endotracheal intubation. Results: Repeated measure of core temperatures indicated a significant difference according to body part (p=.033), time of measure (p<.001) and the reciprocal interaction between body part and time of measure (p<.027). The core temperatures were highest at tympany location, lowest at nasopharynx. The amount of temperature change was least for the esophagus ($36.10{\sim}36.33^{\circ}C$), followed by nasopharynx and tympany. Conclusion: The esophageal core temperature showed the highest stability followed by nasopharyngeal and tympanic temperature. Therefore, close observations are required between 10~20minutes after the beginning of the operation.

3차원 치료계획용 전산화단층촬영에서 영상증강을 위한 최적의 프로토콜에 관한 연구

  • 이상규;이석;김주호;백종걸;조정희;신동봉;박재일
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2002
  • 1. 목적 : 방사선종양학과에서 3차원 치료계획용 전산화단층촬영 시 조영제 주입율에 따른 CT 값(hounsfield unit, H.U) 변화를 정량적으로 평가하여 최적의 영상증강효과 및 방사선치료계획을 위한 기초 프로토콜을 제시하고자 한다. 2. 대상 및 방법: 연세암센터 방사선종양학과에서 3차원 치료계획용 전산화단층촬영을 시행한 상복부(폐암)환자 20명을 대상으로 하였다. 조영제 양(130mL)은 일정하게 고정하였고, 조영제주입율을 1.2, 1.5, 2.0 mL/sec로 변화시켜가며 조영제를 주입하면서 3차원 방사선치료계획영상에 적합한 조영제주입율(contrast flow rate)과 지연시간(delay time)을 도출하였고, CT 값을 측정하여 정량적 평가를 시행하였다. 관심부위는 폐동맥과 폐정맥으로 하였다. 그리고, 환자 기본정보, 조영제주입율, H.U 등 영상증강에 영향을 미치는 인자들을 통계처리 프로그램인 SPSS를 이용하여 최적의 영상을 획득할 수 있는 기초 프로토콜을 작성하였다. 3. 결과 : 폐암환자의 전산화단층촬영영상 획득 시 3차원 방사선치료계획에 적합한 영상을 얻을 수 있는 조건중 조영제주입율은 1.5 mL/sec 이었고, 지연시간은 $60{\sim}70$초이었다. 통계처리를 수행한 결과 환자의 기본정보 및 조영제주입율 등이 영상증강에 영향을 미치는 인자임을 알 수 있었다. 본 연구에서 작성한 기초 프로토콜을 이용하여 3차원 방사선치료계획 시 정확한 종양 및 정상조직 설정이 용이하게 되어 방사선치료 효율을 극대화 할 수 있었다. 4. 결론 : 방사선종양학과에서 3차원 치료계획용 전산화단층촬영 시 사용할 수 있는 기초적인 영상획득 프로토콜을 도출하였고, 향후 더 많은 임상경험과 정량적 평가가 수반된다면 임상에 적극 사용할 수 있을 것이라 사료된다.

  • PDF

Relationship of Strength of Hand Grip, Low Back Muscles and Knee Joint Muscles, to Bone Mineral Densities of these Sites in Young Women (청년기 여성의 악력, 요부근력, 슬관절근력과 각 해당부위별 골밀도의 관계)

  • Kim Ju-Sung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.10 no.1
    • /
    • pp.30-36
    • /
    • 2003
  • Purpose: The strength of hand grip, low back muscles and knee joint muscles were measured and then compared to the bone mineral density (BMD) of each forearm bones (including ulna and radius), lumbar spine, and femur in young women in order to identify the relationship between muscle strength and bone mineral density. Method: The BMD was measured with a Dual Energy X-ray Absorptiometry and muscle strength was measured with a handgrip dynamometer and a Cybex Norm. Data were analyzed with frequencies, percentages, means, and Pearson correlation coefficients. Result: 1) Higher grip strength correlated positively with higher BMD in the forearm (r=.246, p=.007), higher low back extensor strength with higher BMD in the femur (neck, trochanter and Ward's triangle)($r=.323{\sim}.226$, $p=.003{\sim}.043$) and higher strength in the knee joint extensor with higher BMD in the lumbar spine (r=.227, p=.041), femur neck, and femur trochanter significantly ($r=.295{\sim}.226$, $p=.007{\sim}.043$). There was no significant correlation between the strength of low back extensors and BMD in the lumbar spine, now with strength of knee joint flexor and the BMD in the femur. 2) The muscle strength of each part of the body had significant positive correlations to each other part ($r=.255{\sim}.728$ $p=.021{\sim}.000$) Conclusion: The results of this study showed that with the development of a muscle there was an increased BMD of the corresponding part, and the BMD of each part was influenced by adjacent muscles. To promote the health of bones, it is important to strengthen the muscles of related bones, based on balanced development of all muscles.

  • PDF