• Title/Summary/Keyword: 기반암까지의 심도

Search Result 107, Processing Time 0.021 seconds

Bedrock Depth Variations and Their Applications to identify Blind Faults in the Pohang area using the Horizontal-to-Vertical Spectral Ratio (HVSR) (포항지역 HVSR에 의한 기반암 심도와 단층 식별 연구)

  • Kang, Su Young;Kim, Kwang-Hee
    • Journal of the Korean earth science society
    • /
    • v.43 no.1
    • /
    • pp.188-198
    • /
    • 2022
  • Some deep faults do not reach the ground surface and are seldom recognized. Gokgang Fault area in the east of the Heunghae area of the Pohang basin has been selected to confirm the feasibility of the Horizontal-to-Vertical Spectral Ratio (HVSR) approach to identify blind faults. Densely spaced microtremor data have been acquired along two lines in the study area and processed to obtain resonance frequencies. An empirical relationship between the resonance frequency and the bedrock depth was proposed using borehole data available in the study area. Resonance frequencies along two lines were then converted to bedrock depths. The resulting depth profiles show significant lateral variations in the bedrock depth. As expected, considerable variation in the resonance frequency is observed near the Gokgang fault. The depth profiles also present additional significant variations in the resonance frequencies and the bedrock depths. The feature is presumably related to a blind fault that is previously unknown. Therefore, this case study confirms the feasibility of the HVSR technique to identify faults otherwise not recognized on the surface.

Seismic Refraction Analysis to Estimate the Depth to the Bedrock: Case Study (기반암 깊이 도출을 위한 굴절법 탄성파 자료 분석: 사례연구)

  • Lee, Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.4
    • /
    • pp.237-242
    • /
    • 2005
  • A seismic refraction study in estimation of depth to the bedrock demonstrates that 1) the average velocity in the medium is about 250 m/s in the surface layer (< 4 m), 2,500 m/s in the weathered formation, and greater than 3,000 m/s in the bedrock, 2) the depth to the deepest reflector assumed to be the bedrock is about 17 m; however, according to the cores collected in a borehole in study area, the bedrock (granite) occurred at depth 25 m, 3) according to the density and velocity logging, at depth 17 m, a measurable velocity and density increase are observed, and 4) the velocity of the weathered formation is relatively high and therefore, the acquisition offsets ($70{\sim}80m$) are turned out not to be long enough to record the refracted signal from the bedrock at depth 25 m as first arrivals.

Analysis of a Structure of the Kunsan Basin in Yellow Sea Using Gravity and Magnetic Data (중자력 자료를 이용한 황해 군산분지의 지질 구조 해석)

  • Park, Gye-Soon;Choi, Jong-Keun;Koo, June-Mo;Kwon, Byung-Doo
    • Journal of the Korean earth science society
    • /
    • v.30 no.1
    • /
    • pp.49-57
    • /
    • 2009
  • We studied a structure of the Kunsan basin in the Yellow Sea using ship-borne magnetic data and altimetry satellite-derived gravity data provided from the Scripps institution of oceanography in 2006. The gravity data was analyzed via power spectrum analysis and gravity inversion, and the magnetic data via analytic signal technique, pseudo-gravity transformation, and its inversion. The results showed that the depth of bedrock tended to increase as we approached the center of the South Central Sag in Kunsan basin and that the maximum and minimum of its depth were estimated to be about 6-8 km and 2 km, respectively. Inaddition, the observed high anomaly of gravity and magnetism was attributed to the intrusion of igneous rock of higher density than the surrounding basement rock in the center of South Central Sag, which was consistent with the interpretation of seismic data obtained in the same region.

지반 개량된 조간대 퇴적층에 대한 물리탐사 연구

  • 김성욱;이현재;김인수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.319-322
    • /
    • 2002
  • 그라우팅으로 지반 개량된 조간대 퇴적층의 지층구조를 규명하기 위한 방법으로 전기비저항탐사, 굴절법 탄성파탐사, 지하레이더탐사를 실시하였다. 연구대상 지반의 10m 전후 심도에서 해수의 영향을 받는 수평의 저비저항대가 발달하며, 저비저항대는 모래가 우세한 지층에 해당한다. 지반의 탄성파 속도는 1~3km/sec의 범위로 조간대의 미고결 퇴적층과 비교할 때 매우 높은 속도에 보여준다. 지반의 높은 속도는 지반 개량의 효과로 판단된다. 지하레이더탐사에서 퇴적층의 구성 물질에 따라 교반 정도가 달지는데 모래층은 퇴적물과 주입제의 교반이 잘 이루어져 불규칙한 반사면으로 나타나며, 점토층은 교반이 불량하여 개량된 부분은 주상으로 관찰된다. 물리탐사의 결과와 시추조사를 대비할 때 지반 개량은 기반암까지 시행되었으며, 양호한 암반을 지시하는 고비저항대와 고속도층은 내륙으로 갈수록 깊은 심도를 보여준다. 이것은 지반 개량 이전의 기반암 심도와는 상반되는 것으로 지반 개량의 효과는 해안방면의 지층에서 잘 나타난다.

  • PDF

Towards remote sensing of sediment thickness and depth to bedrock in shallow seawater using airborne TEM (항공 TEM 을 이용한 천해지역에서의 퇴적층 두께 및 기반암 심도 원격탐사에 관하여)

  • Vrbancich, Julian;Fullagar, Peter K.
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.1
    • /
    • pp.77-88
    • /
    • 2007
  • Following a successful bathymetric mapping demonstration in a previous study, the potential of airborne EM for seafloor characterisation has been investigated. The sediment thickness inferred from 1D inversion of helicopter-borne time-domain electromagnetic (TEM) data has been compared with estimates based on marine seismic studies. Generally, the two estimates of sediment thickness, and hence depth to resistive bedrock, were in reasonable agreement when the seawater was ${\sim}20\;m$ deep and the sediment was less than ${\sim}40\;m$ thick. Inversion of noisy synthetic data showed that recovered models closely resemble the true models, even when the starting model is dissimilar to the true model, in keeping with the uniqueness theorem for EM soundings. The standard deviations associated with shallow seawater depths inferred from noisy synthetic data are about ${\pm}5\;%$ of depth, comparable with the errors of approximately ${\pm}1\;m$ arising during inversion of real data. The corresponding uncertainty in depth-to-bedrock estimates, based on synthetic data inversion, is of order of ${\pm}10\;%$. The mean inverted depths of both seawater and sediment inferred from noisy synthetic data are accurate to ${\sim}1\;m$, illustrating the improvement in accuracy resulting from stacking. It is concluded that a carefully calibrated airborne TEM system has potential for surveying sediment thickness and bedrock topography, and for characterising seafloor resistivity in shallow coastal waters.

Seismic Fragility of Bridge Considering Foundation and Soil Structure Interaction (교량기초 종류 및 지반-구조물 상호작용을 고려한 지진취약도 분석)

  • Kim, Sun-Jae;An, Hyo-Joon;Song, Ki-il
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.129-137
    • /
    • 2020
  • In performing the structural analysis, the foundation is considered to be a fixed end as a plastic hinge model. In this study, the displacements of the foundation, pier, and shoe were compared when the foundation modeled as a fixed end, a shallow foundation constructed on bedrock of 2m depth, and a pile foundation constructed in the 10m to 20m depth of bedrock. The shear force was also compared, and the probability of damage was calculated and compared for the critical condition. When calculated as a fixed end, the displacement of the foundation converged to 0mm, but the shallow foundation built on the bedrock with a depth of 2m caused relatively displacement, and the pile foundation constructed to contact the bedrock with a depth of 18m caused a larger displacement. In addition, it was analyzed that the displacement of the foundation, which is the lower structure, affects the displacement of the super structure, but the difference in shear force applied to the foundation was insignificant in the three cases. There was no difference between the shallow foundation and the pile foundation in the influence on the displacement of the top of the pier, but there was a big difference from the analysis assuming as a fixed end.

전라남도 남악 일원에 분포하는 조간대 퇴적층의 전기비저항 연구

  • 김성욱;이현재;최은경;안윤희
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.212-215
    • /
    • 2001
  • 남악지역에 분포하는 조간대 퇴적층의 층서구조와 퇴적심도 및 기반암의 단열구조를 파악하기 위한 전기비저항탐사를 실시하였다. 조간대 퇴적물에서 비저항은 하부로 갈수록 증가하며 대부분 3.0 Ohm-m이하의 비저항으로 고비저항의 기반암의 기반암과 뚜렷한 경계를 보여준다. 퇴적층의 층후는 퇴적지 중앙부에서 30m를 최대로 북쪽 (고해안선)과 남쪽 (영산강)으로 갈수록 감소하는 경향을 보여주는데 선행 조사된 시추결과와 일치한다. 일부 지역의 전기비저항 해석단면과 시추단면에서 견고한 점토질 (stiff)의 지층이 분포하는데 이 지층은 북서-남동 방향의 고해안선과 나란하게 분포한다. 이것은 퇴적물을 공급한 흐름의 방향과 조간대의 확장방향이 북서-남동 방향임을 지시한다. 기반암의 단열구조로 판단되는 저비저항대는 조사지역의 동부에 집중되어 있으며 단열대의 연장방향은 북서-남동 방향이 우세하다.

  • PDF

Development of Site Classification System and Modification of Design Response Spectra considering Geotechnical Site Characteristics in Korea (II) - Development of Site Classification System (국내 지반특성에 적합한 지반분류 방법 및 설계응답스펙트럼 개선에 대한 연구 (II) - 지반분류 개선방법)

  • Yoon, Jong-Ku;Kim, Dong-Soo;Bang, Eun-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.2 s.48
    • /
    • pp.51-62
    • /
    • 2006
  • In the companion paper (I-Problem Statements of the Current Seismic Design Code), the current Korean seismic design code is required to be modified considering site characteristics in Korea for the reliable estimation of site amplification. In this paper, three site classification methods based on the mean shear wave velocity of the top 30m $V_{S30}$, fundamental site periods $(T_G)$ and bedrock depth were investigated and compared with each other to determine the best classification system. Not enough of a difference in the standard deviation of site coefficients $(F_a\;and\;F_v)$ to determine the best system, and neither is the difference between the average spectral accelerations and the design response spectrum of each system. However, the amplification range of RRS values based on $T_G$ were definitely concentrated on a narrow band than other classification system. It means that sites which have a similar behavior during earthquake will be classified as the same site category at the site classification system based on $T_G$. The regression curves between site coefficients and $T_G$ described the effect of soil non linearity well as the rock shaking intensity increases than the current method based on $V_{S30}$. Furthermore, it is unambiguous to determine sue category based on $T_G$ when the site investigation is performed to shallower depth less than 30m, whereas the current $V_{S30}$ is usually calculated fallaciously by extrapolating the $V_s$ of bedrock to 30m. From the results of this study, new site classification system based on $T_G$ was recommended for legions of shallow bedrock depth in Korea.

Seafloor Topographic Survey with Bedrock (기반암 정보를 포함한 해저 지형 조사 연구)

  • Kim, Myoung-Bae;Kwak, Kang-Yul
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.4
    • /
    • pp.343-349
    • /
    • 2011
  • Seabed topography and marine site survey should be performed first in the design and construction of marine structures. We could successfully acquire the seafloor topography information can be obtained by bathymetric survey and side scan sonar and the sediment layer thickness and 3D bedrock depth by seismic reflection. It is necessary to apply carry out the integrated interpretation to each other in the ocean civil Eng. In this paper, we have obtained information on the sea bottom topography and water depth at the same time using interferometer technique and on the basement depth by seismic reflection. We have performed to assess the proposed method on the seafloor topographic survey with bedrock.

Groundwater Conditions reiated with the Geologic Structures of Bedrocks in the Gyuk-Po Area. (격포 기반암의 지질구조와 지하수 상태)

  • 박동극
    • The Journal of Engineering Geology
    • /
    • v.3 no.2
    • /
    • pp.115-124
    • /
    • 1993
  • Hydrogeological survey related to groundwater condifiors was performed at the study area in Gyukpo, BuanGun, ChunlabukDo to express the relationships between groundwater conditions and the geologic structures such as joints, faults and beddings in bedrock About 200 joints and sjgnfficant faults were measured in this area. Typically, The fracture analysis on cores of 7 boreholes was tried to quantify fracture numerically. Groundwater level was periodically measured for three months. The packer tests of about 175 were carried out in 7 boreholes. As the result, Fractures are locaHy developed as ground water bearing zone and an average hydraulic conductivity of bedrock is $1{\times}10^{-5}cm/sec$ in this area the hydraulic conductivity of this area is correlated with fracture frequency value of F15 and is also well correlated with fracture developed and depth. In accordance with depth, fracture frequency and hydraulic conductivity are decreased. Hydraulic conductivity of granite along depth shows an obiouse change in values but that of sedimentary rocks do not shows changeless. Groundwater movement in the bedrocks of the study area affected not by joints but faults developed in the different rock boundary. In the northern part of this area, The differences of hydraulic conductivity between granite and sedimentary rocks give rise abrsspt at difference in groundwater leveL In the southern part of the study area, there is no different in groundwater level of both same rock types.

  • PDF