• Title/Summary/Keyword: 기대피해

Search Result 1,021, Processing Time 0.03 seconds

Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter (겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.583-597
    • /
    • 2014
  • Fire caused by heater has various causes as many as the types of heater. also, lots of damage of human life and property loss are caused, since annually continuous fire accident by heater in traditional market is frequently occurring. There are not many cases of fire due to heater in most of residential facilities such as general house, apartments, etc., because they are supplied with heating boiler, however the restaurant, store and office of the market, sports center, factory, workplace, etc. still use heater, e.g. oilstove, electric heater, etc., so that they are exposed to fire hazard. Also, when investigating the number of fire due to heater, it was analyzed to occur in order of home boiler, charcoal stove, oilstove, gas heater/stove, electric stove/heater, the number of fire per human life damage was analyzed in order of gas heater/stove, oil heater/stove, electric heater/stove, briquette/coal heater. Also, gas and oil related heater were analyzed to have low frequency, however, with high fire intensity. Therefore, this research aimed at considering more scientific fire inspection and identification approach by reenacting and reviewing fire outbreak possibility caused by combustibles' contact and conductivity under the normal condition and abnormal condition in respect of ignition hazard, i.e. minimum ignition temperature, carbonization degree and heat flux along with it, due to oilstove and electric stove, which are still frequently used in public use facility, traditional market, and, of which actual fire occurrence is the most frequent. As the result of reenact test, ignition hazard appeared very small, as long as enough heat storage condition is not made in both test objects(oilstove/electric stove), however carbonization condition was analyzed to be proceeded per each part respectively. Eventually, transition to fire is the ignition due to heat storage, so that it was analyzed to ignite when minimum heat storage temperature condition of fire place is over $500^{\circ}C$. Particularly, in case of quartz pipe, the heating element of electric stove, it is rapidly heated over the temperature of $600^{\circ}C$ within the shortest time(10sec), so that the heat flux of this appears 6.26kW/m2, which was analyzed to result in damage of thermal PVC cable and second-degree burn in human body. Also, the researcher recognized that the temperature change along with Geometric View Factor and Fire Load, which display decrease of heat, are also important variables to be considered, along with distance change besides temperature condition. Therefore, the researcher considers that a manual of careful fire inspection and identification on this is necessary, also, expects that scientific and rational efforts of this research can contribute to establish manual composition and theoretical basis on henceforth fire inspection and identification.

A Study on the Retransmission Consent and Arbitration for the Retransmission of Terrestrial Broadcasting Signal in Japan (지상파채널의 재전송 동의와 중재 기준에 관한 연구 - 일본의 사례분석을 중심으로)

  • Kim, Kyung-Hwan
    • Korean journal of communication and information
    • /
    • v.48
    • /
    • pp.46-62
    • /
    • 2009
  • The current study attempted to review the standards of retransmisison consent and arbitration for the terrestrial broadcasting signal. The standards are based upon the principles encouraged by the MIAC(Ministry of Internal Affairs and Communications). It has been criticized that the standards of judgement for the retransimission consent and arbitration are ambiguous and arbitrary in Japan. In 2009, MIAC announced five decisions regarding the retransmission of over-the-air. The result of the current study found that the regulations of compulsory over-the-air signal retransmission have been sustained until now. The retransmission policy of the Japan government based upon three principles; localism, proper cause and copyright act. The judgment is dependent on the intrepretation of MIAC's standard about these three principles.

  • PDF

Management of the Nakdong-Jeongmaek based on the Characteristics of Cold Air - Focused on Busan, Ulsan, Pohang - (찬공기 특성을 고려한 낙동정맥 관리방안 연구 - 부산, 울산, 포항 인근을 대상으로 -)

  • Eum, Jeong-Hee;Son, Jeong-Min
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.5
    • /
    • pp.103-115
    • /
    • 2016
  • This study aims to analyze the properties of cold air production and its flow of Nakdong-Jeongmaek(mountain ranges), and to suggest management strategies for Nakdong-Jeongmaek in order to enhance the green air conditioning functions of Jeongmaek. For this purpose, three study sites including Gudeoksan Mountain and the vicinity in Busan, Goheonsan Mountain and the vicinity in Ulsan, and Unjusan Mountain and the vicinity in Pohang were selected. The results found that cold air flow and its height of the three study sites were analyzed based on topographic properties and land use. Management strategies for preserving and enhancing their temperature reduction functions were suggested. The cold air produced in the vicinity of Gudeoksan was not fully developed and spread because of the high-density development at the border of Jeongmaek. Since high pressures of development are expected at the border, high conservation policies are required. In the vicinity of Goheonsan, where the agricultural complex and industrial park are located, cold air flows well throughout the entire study site thanks to fully developed cold air in the wide, flat valley. Hence, plans to maintain the current cold air flow are required, and conservation plans to mitigate future developments are also needed in the flat valley. The cold air in Unjusan and the vicinity with its complex and narrow mountain valleys gradually develops into valley bottoms. In order to take advantage of the terrain, the valley near the cold air production areas are preserved. In particular, special plans are required to prevent damage to the cold air layer near Youngcheonho Lake, where the highest height of cold air was recorded due to the closed and lower terrain feature. This study could support the establishment of systematic management plans of Nakdong-Jeongmaek to preserve and enhance its green air conditioning functions.

A standardized procedure on building spectral library for hazardous chemicals mixed in river flow using hyperspectral image (초분광 영상을 활용한 하천수 혼합 유해화학물질 표준 분광라이브러리 구축 방안)

  • Gwon, Yeonghwa;Kim, Dongsu;You, Hojun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.10
    • /
    • pp.845-859
    • /
    • 2020
  • Climate change and recent heat waves have drawn public attention toward other environmental issues, such as water pollution in the form of algal blooms, chemical leaks, and oil spills. Water pollution by the leakage of chemicals may severely affect human health as well as contaminate the air, water, and soil and cause discoloration or death of crops that come in contact with these chemicals. Chemicals that may spill into water streams are often colorless and water-soluble, which makes it difficult to determine whether the water is polluted using the naked eye. When a chemical spill occurs, it is usually detected through a simple contact detection device by installing sensors at locations where leakage is likely to occur. The drawback with the approach using contact detection sensors is that it relies heavily on the skill of field workers. Moreover, these sensors are installed at a limited number of locations, so spill detection is not possible in areas where they are not installed. Recently hyperspectral images have been used to identify land cover and vegetation and to determine water quality by analyzing the inherent spectral characteristics of these materials. While hyperspectral sensors can potentially be used to detect chemical substances, there is currently a lack of research on the detection of chemicals in water streams using hyperspectral sensors. Therefore, this study utilized remote sensing techniques and the latest sensor technology to overcome the limitations of contact detection technology in detecting the leakage of hazardous chemical into aquatic systems. In this study, we aimed to determine whether 18 types of hazardous chemicals could be individually classified using hyperspectral image. To this end, we obtained hyperspectral images of each chemical to establish a spectral library. We expect that future studies will expand the spectral library database for hazardous chemicals and that verification of its application in water streams will be conducted so that it can be applied to real-time monitoring to facilitate rapid detection and response when a chemical spill has occurred.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Hydraulic Stability Examination of Rainwater Reservoir Pipe Network System on Various Inflow Conditions (유입량 변화에 따른 도심지 내 우수저류조 관망시스템의 안정성 검토)

  • Yoo, Hyung Ju;Kim, Dong Hyun;Maeng, Seung Jin;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.4
    • /
    • pp.1-13
    • /
    • 2019
  • Recently, as the occurrence frequency of sudden floods due to climate change increased, it is necessary to install the facilities that can cope with the initial stormwater. Most researches have been conducted on the design of facilities applying the Low Impact Development (LID) and the reduction effect on rainfall runoff to examine with 1D or 2D numerical models. However, the studies on the examination about flow characteristics and stability of pipe network systems were relatively insufficient in the literature. In this study, the stability of the pipe network system in rainwater storage tank was examined by using 3D numerical model, FLOW-3D. The changes of velocity and dynamic pressure were examined according to the number of rainwater storage tank and compared with the design criteria to derive the optimal design plan for a rainwater storage tank. As a results of numerical simulation with the design values in the previous study, it was confirmed that the velocity became increased as the number of rainwater storage tank increased. And magnitude of the velocity in pipes was formed within the design criteria. However, the velocity in the additional rainwater storage pipe was about 3.44 m/s exceeding the allowable range of the design criteria, when three or more additional rainwater storage tanks were installed. In the case of turbulence intensity and bottom shear stress, the bottom shear stress was larger than the critical shear stress as the additional rainwater storage was increased. So, the deposition of sediment was unlikely to occur, but it should be considered that the floc was formed by the reduction of the turbulence intensity. In addition, the dynamic pressure was also satisfied with the design criteria when the results were compared with the allowable internal pressure of the pipes generally used in the design of rainwater storage tank. Based on these results, it was suitable to install up to two additional rainwater storage tanks because the drainage becomes well when increasing of the number of storage tank and the velocity in the pipe becomes faster to be vulnerable to damage the pipe. However, this study has a assumption about the specifications of the rainwater storage tanks and the inflow of stormwater and has a limitation such that deriving the suitable rainwater storage tank design by simply adding the storage tank. Therefore, the various storage tank types and stormwater inflow scenarios will be asked to derive more efficient design plans in the future.

Feed Value, Growth and Dry Matter Yield of High Yielding Rice(Oryza sativa L.) for the Twice-cutting System (2회 예취 재배법을 이용한 초다수 벼(Oryza sativa L.) 계통의 생육·수량 및 사료가치 평가)

  • 백진수;이점호;정오영;홍하철;이규성;진일두;이상복;최용환;양창인;김종근;김병완;김홍열;양세준;이영태
    • Journal of Animal Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.443-452
    • /
    • 2006
  • The four rice(Oryza sativa L.) lines, previously demonstrated to have vigorous herbage production at the vegetative growth stage, were investigated for their growth traits, dry matter yield and feed value using the twice-cutting system that 1st-cut is harvested at panicle formation stage and 2nd-cut at the yellow ripen stage. The twice-cutting system is regarded as an effective method in the production of forage rice by escaping lodging and insect damages caused by the overgrowth and typhoon around the heading stage.The feed value of the twice-cut rice plant of there lines were compared with the control of normal, cutting at the yellow ripen stage. The relative feed value(RFV), the total digestible nutrient(TDN) and the crude protein(CP) content of the twice-cut straw were higher the control in every lines. However, the dry matter yield (DMY), represented by the summed forage production of 1st and 2nd cut-rice plant, were lower the control, and the DMY of straws were increase but grains were decrease for twice-cutting system. In addition, TDN yield showed the similar tendency with DMY.Recently, as one of the breeding aims the researches for improving the digestibility of rice straw have been required. In this regard, twice-cutting system is recognized with the fact that it has the effect which raises the digestibility of the straw. Especially, the 2nd cut of IR73111-B-R-15-3-1 line was similar to the control at the TDN yield of straw, and would be used as a breeding material for product the roughage of good quality.

A Study on Dose Assessment by 18F-FDG injected into Patients (환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구)

  • Kim, Chang-Ju;Kim, Jang-Oh;Jeong, Geun-Woo;Shin, Ji-Hey;Lee, Ji-Eun;Jeon, Chan-Hee;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.467-475
    • /
    • 2020
  • The purpose of this study is to assess doses to 18F-FDG, a radioactive drug, during PET examinations, to alleviate anxiety about radiation in patients and carers, to minimize the indiscriminate examination progress caused by medical institution personnel and space clearance problems, and health examination. The dose assessment was measured using a thermo-fluorescent dosimeter (TLD) and an electronic personal dosimeter (EPD) at the location of the cervical (hypothyroid), thorax (heart), and lower abdomen (breeding line) which are the three highest tissue areas of the radiation tissue weighting. In addition, spatial dose rates and radioactivity in urine were measured using GM counters and ion boxes. The results are as follows: First, the personal dosimeter TLD was measured 0.0425±0.0277 mSv in the cervical region, 0.0440±0.0386 mSv in the thorax and 0.0485±0.0436 mSv in the lower abdomen, with little difference in the heart dose depending on radiation sensitivity. The EPD was measured at 0.942±0.141 mSv/h immediately after the cervical position, and 0.192±0.031 mSv/h after 120 minutes. Immediately after the thorax position, 0.516±0.085 mSv/h, 120 minutes later 0.128±0.040 mSv/h. Immediately after the lower abdomen position, 0.468±0.091 mSv/h, and after 120 minutes 0.105±0.021 mSv/h were measured. The spatial dose rate at the GM counter was measured immediately at 0.041±0.005 mSv/h, 120 minutes later at 0.014±0.002 mSv/h. The radioactivity in urine using ion chamber was measured at 0.113±0.24 MBq/cc after 60 minutes and 0.063±0.13 MBq/cc after 120 minutes. As a result, 18F-FDG should be administered, dose re-evaluated two hours after the PET test is completed, and caregivers should be avoided. In addition, it is deemed necessary to provide patients and carers with sufficient explanations and expected values of exposure dose to avoid reckless testing. It is hoped that the data tested in this study will help patients and families relieve anxiety about radiation, and that the radiation workers' exposure management system and institutional improvements will contribute to the development of medical radiation.

Assessment of Hydrochemistry and Irrigation Water Quality of Wicheon Watershed in the Gyeongsangbuk-do (경상북도 위천수계의 수리화학적 특성 및 관개용수 수질평가)

  • Lee, Gi-Chang;Park, Moung-Sub;Kim, Jae-Sik;Jang, Tae-Kwon;Kim, Hyo-Sun;Lee, Hwa-Sung;Son, Jin-Chang
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.1
    • /
    • pp.36-43
    • /
    • 2020
  • BACKGROUND: Wicheon watershed has the largest irrigation area among the mid-watershed of Nakdong river. However, no investigation of irrigation water quality has been conducted on the Wicheon watershed, which evaluates the effects on the soil quality and crop cultivation. Therefore, this study aims to provide various assessments of water quality of Wicheon watershed as the scientific basic data for efficient agricultural activities. METHODS AND RESULTS: Water sampling was performed in five locations of the first tributaries of Wicheon. Wicheon watershed showed clean water quality with very low organic matters and safe water quality from metals at all points of investigation. It was estimated that the natural chemical components of Wicheon watershed were originated from water-rock interaction in Gibbs diagram. All samples were concentrated in the type of Ca-HCO3-Cl in the Piper diagram. The quality of irrigation water was evaluated with sodium adsorption ratio (SAR), residual sodium carbonate (RSC), permeability index (PI), and percent sodium (%Na). The values of these water quality indices were in the range of 0.37-0.67, -2.11--0.24, 41.13-84.52% and 11.28-21.84%, respectively, and were classified as good grades at all sites. CONCLUSION: The water quality of Wicheon watershed was very low in salt, indicating good irrigation water suitable for growing agricultural products. We hope that the results of this study will be used as the basic data for the cultivation of agricultural products and promotion of their excellence.

'Saeyoung', a Winter Forage Triticale Cultivare of High-Yielding and Tolerance to Cold (추위에 강하고 수량이 많은 조사료용 트리티케일 품종 '세영')

  • Han, Ouk-Kyu;Park, Hyung-Ho;Park, Tae-Il;Cho, Sang-Kyun;Choi, In-Bae;Noh, Jae-Hwan;Kim, Kee-Jong;Oh, Young-Jin;Park, Ki-Hun;Kim, Dea-Wook;Ku, Ja-Hwan;Kweon, Soon-Jong;Ahn, Jong-Woong
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.37 no.2
    • /
    • pp.125-131
    • /
    • 2017
  • 'Saeyoung', a winter triticale (X Triticosecale Wittmack) for forage, was developed at the Department of Rice and Winter Cereal Crop, NICS, RDA in 2012. The cultivar 'Saeyoung' has narrow and long leaves of light green color, middle size and thin culm, and a medium grain of brown color. The heading date and yellow ripe stage of 'Saeyoung' was May 3 and May 27, which were similar to check cultivar 'Shinyoung', respectively. 'Saeyoung' showed a little stronger in cold tolerance and a little weaker in resistance to lodging than the check, and wet injury, powdery mildew, and leaf rust were similar to those of the check cultivar. The forage fresh and dry matter yields of 'Saeyoung' at milk-ripe stages were 47.2 and $15.6MT\;ha^{-1}$, respectively, which was 9% and 4% higher than those of the check. The crude protein content of 'Saeyoung' was 0.4% lower than 6.8% of the check, while was higher than the check cultivar 'Shinyoung' in neutral detergent fiber, acid detergent fiber. Total digestible nutrients of 'Saeyoung' was also 3% lower than 62.8% of the check cultivar. It showed grain yield of $4.1MT\;ha^{-1}$, which was 11% higher than that of the check. 'Saeyoung' is recommended for fall sowing forage crops in areas in which average daily minimum mean temperatures in January are higher than $-10^{\circ}C$.