• Title/Summary/Keyword: 기능계획

Search Result 2,219, Processing Time 0.033 seconds

Development of Mission Analysis Tool for eVTOL Aircrafts of Lift-Tilt Concept (Lift-Tilt 개념의 eVTOL 항공기 임무 분석 도구 개발)

  • Paek, Seung-Kil;Chae, Sanghyun;Kang, Hee Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.10
    • /
    • pp.859-870
    • /
    • 2021
  • KARI (Korea Aerospace Research Institute) is developing a design framework for the concept and preliminary design of eVTOL aircrafts. A low fidelity mission analysis tool was developed for the eVTOL aircrafts of Lift-Tilt Concept, which have tilt propellers and lift propellers, using open source SUAVE package. For its development, a review for the propeller performance analysis functionality was made. To find the trim solution at each mission segment automatically, an algorithm is implemented, using a global optimization technique through parallel processings and DOE(design of experiment). Using the tool, the one seated eVTOL OPPAV(optionally piloted personal air vehicle) was modeled and evaluated, which results were compared with the preliminary design data.

Design and Implementation of Web Based Distribution Automation Management System (웹기반 배전자동화시스템의 설계 및 구현)

  • Hong, Jung-Hun;Kim, Yong-Deok;Yang, Hae-Sool
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.05a
    • /
    • pp.269-272
    • /
    • 2004
  • 1950년대 동란을 거쳐 1960년대 초반부터 시작된 경제개발계획에 의해 급격한 경제성장으로 인해 산업 인구의 대도시 집중화에 의하여 전기의 공급력 부족 현상은 지속되었다. 따라서, 이때부터 성장한 경제배전계통은 수적으로도 많고 광범위하게 산재되어 있어 인력에 의해서는 더 이상 효과적인 관리가 어렵게 되었고, 사회가 고도 정보화로 진전되면서 수용가는 한층 더 높은 공급 신뢰도와 고품질의 전력공급을 요구하고 있다. 이러한 변화에 따라 전력공급자는 전력계통에 대한 감시와 제어를 통하여 항시 안정적이고 신뢰성있는 운용을 하여야한다. 이에 따라 배전계통에 설치된 배전설비를 컴퓨터와 통신수단을 이용하여 원격지에서 감시 제어할 수 있는 배전자동화 시스템에 대한 연구가 오래 전부터 이루어져 왔으며 효과적으로 양질의 전력을 공급하고자 배전자동화 시스템(DAS)이 도입되었다. 본 연구에서는 능동적인 감시 및 제어기능을 제공하는 객체지향형 능동데이터베이스 알고리즘을 사용하여 배전계통 제어에 적용하였고 기존의 인터넷 통신망을 통한 감시 및 제어가 가능하게 하였으며 이러한 효과에 의해 배전계통이 여러개의 다른 전력회사로 분할될 경우 각기 존재하는 다른 시스템에 대하여 인터넷을 통한 연계가 가능하도록 하여 통합적인 데이터베이스를 구축하는데 용이하게 하였다.

  • PDF

A Study on Modeling of Test Result Management Component based on Software Product Line (소프트웨어 프로덕트 라인에서의 성적관리 컴포넌트 모델링에 관한 연구)

  • Kim, Su-Youn;Kim, Ji-Young;Kim, Haeng-Kon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.05a
    • /
    • pp.947-950
    • /
    • 2004
  • 프로덕트 라인은 다양하고 빠르게 변화하는 시장의 요구사항과 특정 도메인 영역에 속하는 애플리케이션 간의 재사용 가능한 아키텍처 및 컴포넌트의 구성으로부터 연관된 시스템 구축 시 생산성과 품질의 향상을 제공함으로써 현재 많은 관심의 초점이 되고 있다. 컴포넌트의 가변성은 컴포넌트를 사용자의 요구사항에 알맞게 기능을 특화할 수 있다. 또한 프로덕트 라인에서 컴포넌트 내부에 공통으로 사용할 워크플로를 가지고 있어 컴포넌트 사용자는 순차 다이어그램 등을 통해 메시지 흐름을 직접 구현할 필요가 없고, 재사용 가능한 아키텍처는 많은 변화 계획들과 메카니즘을 포함하고 있다. 하지만, 아키텍처를 설계하기 위한 아키텍처에서의 변화성 관리와 컴포넌트의 변화성에 대한 명확한 방법이 미흡하다. 따라서 본 논문에서는 재사용 가능한 아키텍처를 설계하기 위해 변화성의 명확한 표현과 컴포넌트의 변화성을 설계하기 위해 다중 뷰의 모델링을 통하여 프로덕트 라인의 다양한 측면을 제시하고, 사례연구로 성적관리 컴포넌트 모델링에 적용해 보고자 한다.

  • PDF

Complete mouth rehabilitation with vertical dimension increase in patient with extremely worn dentition (심한 치아 마모를 보이는 환자에서 수직 고경 증가를 동반한 전악 구강 회복 증례)

  • Kim, Sung-Yong;Kim, Na-Hong;Yeom, Kyeong-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.49-56
    • /
    • 2019
  • Generalized severely worn dentition causes occlusal disharmony, esthetic problems, and temporomandibular joint disorders. In order to solve these problems, it is necessary to make a precise analysis of vertical dimension and treatment plans considering it. This case report demonstrates the complete mouth rehabilitation of a 58-year-old male patient with a lot of worn teeth by increasing vertical dimension. Provisional restorations were cemented and after 4 months of evaluation for patient's compliance, permanent prostheses were fabricated. With these treatments, functionally and esthetically satisfactory results were obtained.

Analysis on the Building System Integration Methods of the Salk Institute for Biological Studies (솔크 생물학 연구소에 적용된 건물시스템 통합기법 분석에 관한 연구)

  • Choi, Joon Sung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.7
    • /
    • pp.59-68
    • /
    • 2018
  • Salk Institute for Biological studies is widely considered as architectural masterpiece of Louis Kahn's. Its iconic plaza with symmetrical concrete structures, overlooking the Pacific ocean in La Jolla, has been acclaimed as a facade to the sky. Little has been written on Kahn's achievements in the building system integration in order to bridge the gap between technology and design. This paper explores the technical issues, the design intents, and the major building systems to identify the Kahn's integration methods between building systems. The project is analysed into four major systems; structure, mechanical, envelope, and interior system. The integration methods of building systems are investigated in physical, visual, and functional aspects. The most distinguished cases of building system integration are the introduction of the interstitial floors between the laboratories and the creation of the smooth and warm materiality of exposed concrete walls. Kahn proposed open floor plans for the laboratories which are capable of easily adapting to changing needs. He also introduced the interstitial floors which are framed of the vierendeel truss systems and deliberately overlapped the structure systems with the mechanical systems such as ducts, water pipes, and electric conduits. The exposed concrete walls mixed with pozzolan ashes look very much like granite or limestone as the result of the physical and visual integration between structure, envelope, and interior systems.

From the Functional to the Monumental: The Construction of the Pyongyang Station, 1907-1958 (기능에서 상징으로: 평양역사 건설, 1907-1958)

  • Park, Dongmin
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.4
    • /
    • pp.115-126
    • /
    • 2019
  • Construction of the Pyongyang Railroad Station began in 1907 as an important foothold for the Japanese colonization of the Korean Peninsula and the further invasion of Manchuria. As Pyongyang gradually grew in size and political significance, the Pyongyang Station came to have two responsibilities: Fulfill its functional role and serve as a monument to the growing dignity of the city. This study argues that the Pyongyang Station, newly rebuilt in 1958, was the first building to solve the demands for both functional expansion and the pursuit of monumentality. Stylistically, the original single-story wooden building became a three-story classical masonry building. The stylistic change symbolizes the political shift by which the building was reconstructed. The simple wooden building built by the Japanese, representing Pyongyang's status as a colonial provincial town, was transformed into an imposing gateway for the capital city of a newly born socialist state. Socialist Realism, correctly described by its slogan "socialist in content and national in form," harmoniously blended classical architecture, socialist symbols, and Korean local motifs. This study is significant in that it illustrates the historical changes and continuity of the Pyongyang Station from 1907, when it was first built, through the "liberated space" to the postwar reconstruction period of the 1950s.

Development of Portable IoT Device for Lifesaving (인명 구조용 휴대형 IoT 단말기 개발)

  • Ryu, Dae-Hyun;Choi, Tae-Wan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.883-888
    • /
    • 2022
  • In this paper, we developed a portable IoT device for lifesaving and a web service prototype based on the device and evaluated its functions. The portable IoT terminal for lifesaving is designed for easy to carry, and to communicate possibly between user by LTE Cat. M1 modem which is a low-power broadband IoT communication technology. So, in case of emergency, it is possible to give priority to nearby users and to determine the exact location with built-in GPS. In the future, it will be designed to enable rescue requests in various ways, such as button signals, voice, and acceleration changes.

A Design of Fault Prediction Model for Software Integration Test (소프트웨어 통합테스트를 위한 결함예측모델 설계)

  • Kim, Myeong-Shin;Kang, Dongsu;Baik, Doo-kwon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.04a
    • /
    • pp.969-972
    • /
    • 2010
  • 소프트웨어 제품의 품질을 보장하기 위해서는 제품을 개발하는 단계에 미리 결함율을 예측하여 원하는 수준의 품질을 확보하는 것이 중요하다. 결함은 사용자의 요구사항이 제품으로 구현되고 기능에 대한 테스트가 수행되는 단계에 가장 객관적이며 정량적으로 관리될 수 있다. 따라서 본 논문에서는 통합테스트에 대한 계획을 수립하는 단계에 제품에 대한 결함율을 미리 예측하여 제품 결함율이 조직의 관리범위에 들어올 수 있도록 통제하는 결함예측모델을 제안한다. 조직의 제품 결함율 베이스라인을 설정하고 통합테스트 결함율에 영향을 미치는 변수들과의 회귀분석을 통해 통합테스트 결함예측모형을 구축한다. 또한 제품 결함율에 영향을 미치는 변수들과의 회귀분석을 통해 제품 결함예측모형을 구축하고 결함예측모형을 활용해 제품 결함율을 분석 및 통제한다. 본 논문에서 제안한 결함예측모델은 실제 프로젝트에 적용하여 실효성을 검증하였으며 제품이 완성되기 전에 결함율을 예측하여 통제할 수 있게 함으로써 소프트웨어 품질을 향상한다.

Study on Performance Evaluation Model of River Infrastructures for Life-Cycle Management (생애주기관리를 위한 하천 시설물 성능평가모델에 관한 연구)

  • Yun, Gwan Seon;Kim, Boram;Kim, Hyung-Jun;Yoon, Kwang Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.298-298
    • /
    • 2020
  • 하천 혹은 그 인근에 설치된 시설물은 수문, 통문, 제방, 댐, 보, 배수펌프장, 상·하수도, 하구둑 등이 존재한다. 이러한 하천 시설물은 홍수나 가뭄 등 수해를 저감하는 역할을 한다. 그러나 많은 하천 시설물은 노후화, 기후변화, 하천환경변화 등으로 구조적 혹은 기능적 안정성의 저하가 우려되는 실정이다. 시설물 유형별 고령화율을 살펴보면, 댐, 하천, 상하수도 순으로 조사되었으며, 준공연수가 30년을 초과한 하천 시설물은 약 40%를 넘어섰다. 그럼에도 불구하고 하천시설물의 관리 구조는 시설물 설치단계까지만 치중되었으며, 이후 계획 재수립 단계까지의 평가 및 모니터링, 유지관리, 정보관리 등에 이르는 선순환 구조가 미흡한 실정이다. 시설물의 노후화에 따라 유지관리 비용이 증가하며, 대형사고로 이어질 수 있기 때문에 적절한 시기에 시설물 점검 및 유지보수가 매우 중요하다. 우리나라의 경우 시설물의 안전 및 유지관리에 관한 특별법에 따라 국가주요시설물은 안전점검을 실시하고 있으며, 시설물통합정보관리시스템(Facility Management System; FMS)에 안전등급을 제공하고 있다. 본 연구에서는 FMS의 하천 시설물 안전등급 현황을 기반으로 시설물의 효과적인 생애주기관리를 위해 하천 시설물의 성능평가모델을 제안하였다. 성능평가모델은 하천 시설물의 사용연수에 따른 안전등급의 예측이 가능하며, 관리자 측면에서 예산투입 등의 의사결정 시 활용이 가능할 것으로 판단된다.

  • PDF

Damages of Chuteway Slabs of Spillway by Water Release (수문방류에 따른 여수로 바닥슬래브의 손상 발생)

  • Shin, Dong-Hoon;Jung, Woo-Sung;Yoo, Hyung Ju;Lee, Seung Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.64-64
    • /
    • 2021
  • 댐의 중요 구성요소 중 하나인 여수로 구조물은 관행적으로 단위길이당 100m3/s 정도의 유량이 흐를 수 있도록 설계를 하고, 이를 초과할 때는 여수로 구조물에 피해가 가지 않도록 공기혼입 장치를 설치하거나 콘크리트의 설계강도를 증가시키는 대책을 사용하는 것이 일반적이다(댐설계 기준·해설, 2011) 그러나 건설된 지 오래된 댐의 경우 여수로 콘크리트 구조물의 설계강도가 낮고(최저 16.7MPa) 수문방류 횟수가 많아 최근에 건설된 댐 여수로 보다 상대적으로 많은 손상이 발생되어 있어 잦은 보수보강이 요구되고, 점차 유지관리 비용이 증대되고 있어 노후된 여수로 구조물일수록 기능을 유지하면서도 유지관리 비용을 절감할 수 있는 방안의 수립이 요구되고 있다. 이에 본 연구에서는 𐩒𐩒𐩒댐 여수로를 대상으로 2020년 홍수기 전·후의 여수로 바닥슬래브의 손상상태를 3D드론 매핑, 육안조사 및 내구성 조사결과 등을 이용한 정밀분석을 통해 수문방류시 여수로 바닥슬래브에 가장 큰 손상을 일으키는 손상메커니즘으로 유수에 의한 부상(uplift)에 의한 파손 메커니즘(Flow-driven uplift failure mechanism)을 제시하였으며, 여수로 바닥슬래브의 가장 일반적 손상원인으로 간주되고 있는 공동현상(cavitation)이 공동지수(cavitation index)가 0.3이상인 경우에도 발생할 수 있음을 확인하였다. 이와 같은 관찰 및 분석결과는 보다 많은 사례를 통하여 보완될 경우 향후 여수로 구조물의 설계 뿐만 아니라 보수보강 방법이나 유지관리, 더나아가서는 종합적 댐시설물 자산관리 계획을 수립하는데 매우 유용한 자산이 될 수 있다.

  • PDF