• Title/Summary/Keyword: 기공형태

Search Result 394, Processing Time 0.025 seconds

Naturalization of Implant Prostheses (자연감 있는 임플란트 보철물)

  • Kim, Dae-Hyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.8 no.1
    • /
    • pp.96-103
    • /
    • 1999
  • Restoration of missing oral tissues by using implant therapy is one of viable options in prosthodontic treatment. The purpose of oral rehabilitation are function, esthetics and phonetics. Recently, with the increasing esthetic demand of the patient, dentists and laboratory technicians are more concern ed about natural appearance of implant prostheses. There are so many factors which affect final esthetic results of treatment such a shape, color, proportion, gingival contour etc. To provide natural and vivid looking artificial prostheses to a patient, the careful diagnosis, treatment plan and laboratory Support is crucial. Several cases will be reviewed and discussed in terms of material, gingival shape, contour, speech and connection mode etc. to fabricate natural looking implant prostheses.

  • PDF

고성능 전기화학 장치용 마이크로-나노 하이브리드 다공성 니켈 전극

  • Choe, U-Seong;Sin, Heon-Cheol
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.88.2-88.2
    • /
    • 2012
  • 활성 물질의 원활한 확산을 위한 경사형 마이크로 기공과 넓은 반응 면적을 제공하는 나노 기공을 동시에 가지는 하이브리드 다공성 구리의 전기화학적 합성법이 보고된 이후, 이를 기능성 전기화학 장치에 활용하기 위한 많은 연구가 진행되고 있다. 하지만, 구리는 일반적으로 전기화학적 비활성 물질이기 때문에 전극 활물질로서 직접 활용되는 것은 극히 제한적이다. 또한, 전해 도금에 의하여 합성되므로 비전도성 기재 위에 형성이 불가능하여, 비전도성 기재가 기본이 되는 장치에 적용하는 것 역시 어렵다. 본 연구에서는 전해 도금법을 기본으로 하여 마이크로-나노 하이브리드 다공성 구조를 가지는 니켈을 전도성 및 비전도성 기재 위에 형성하였다. 전도성 기재 위에 제조된 니켈의 구조는 전반적으로 기존의 다공성 구리와 거의 유사하였으나 마이크로 기공의 밀도와 수지상의 형태에 있어 차이점을 보였다. 비전도성 기재 위에 형성된 니켈의 경우에는 중간 열처리 과정으로 인해 나노 수지상 구조의 다소간의 뭉침이 발견될 뿐 전도성 기재 위에 형성된 니켈과 구조가 동일하였다. 전도성 및 비전도성 기재 위에 형성된 니켈 다공성 구조를 기본을 하여 각각 전기화학적 캐패시터용 전극과 연료전지용 전극을 제작하였고, 기본적인 전기화학 특성을 파악하여 니켈 다공성 구조의 응용 가능성을 타진하였다.

  • PDF

Fabrication of Porous Al2O3 Ceramics Using Thermoplastic Polymer (열가소성 고분자를 이용한 다공질 알루미나의 제조)

  • 이상진;김해두
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.7
    • /
    • pp.513-517
    • /
    • 2004
  • Porous alumina ceramics with aligned plate-shaped pores were fabricated by using thermoplastic microsphere in order to show the anisotropy in thermal conductivity. The mixed powder of alumina and microsphere was pressed under 15 MPa till 20$0^{\circ}C$ to deform polymer into platelet-shape and sintered at 1,00$0^{\circ}C$ for 1 h. The sintered specimen with 10 wt% microsphere has 45.3% porosity and the bending strength of 44 MPa. The microstructural investigation confirmed the pore structure of platelet-shape, the thermal conductivities for vertical and parallel directions are 3.803 W/mK and 7.818 W/mK, respectively, the ratio between two directions exceeds 2.

Web viewer for sharing of prosthesis design between laboratory and clinic: Case report (웹뷰어를 이용한 기공실과 진료실 측 간의 보철물 설계 형태의 공유: 증례 보고)

  • Jang, Sung Won;Lee, Ho Jin;Kim, So-Yeun;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.276-282
    • /
    • 2022
  • Close communication between clinicians and dental technicians is an important factor in providing successful prostheses. The exchange of opinions with laboratories has mainly been in the form of written prescriptions and a photos, but it has been reported that information transmission may be limited. Currently, as digital technology-based prosthesis fabrication is common, 3D image objects can be stored on the web and can be easily viewed through a mobile web browser. In this article, we introduce cases where the design of the prosthesis was improved by designing the prosthesis using CAD software and reviewing the prosthesis designed with the clinical side through a web viewer. Through this protocol, it was possible to improve the occlusal surface and crown contour, the opposing teeth condition, the size of the gingival embrasure, and the shape of pontic. The process of sharing, discussing, and modifying the prosthesis design with the clinician and technician through a web viewer contributes to reflecting the diversity of oral conditions and individualized needs, thereby helping to make functional and esthetic prostheses.

Study on Hindered Diffusion of Single Polyelectrolyte Chain in Micro-Pores by Employing Brownian Dynamics Simulations (브라운 동력학 시뮬레이션에 의한 미세기공에서 단일한 다가전해질 사슬의 제한확산 연구)

  • 전명석;곽현욱
    • Membrane Journal
    • /
    • v.12 no.4
    • /
    • pp.207-215
    • /
    • 2002
  • The hindered diffusion in confined spaces is an important phenomenon to understand in a micro-scale the filtration mechanism determined by the particle motion in membrane pores. Compared to the case of spherical colloids, both the theoretical investigations and the experiments on the hindered diffusion of polyelectrolytes is actually more difficult, due to lots of relevant parameters resulting from the complicated conformational properties of the polyelectrolyte chain. We have successfully performed the Brownian dynamics simulations upon a single polyeiectrolyte confined in a slit-like pore, where a coarse-grained bead-spring model incorporated with Debye-Huckel interaction is properly adopted. For the given sizes of both the polyelectrolyte and the pore width, the hindered diffusion coefficient decreases as the solution ionic concentration decreases. It is evident that a charge effect of the pore wall enhances the hindered diffusion of polyelectrolyte. Simulation results allow us to make sense of the diffusive transport through the micro-pore, which is restricted by the influences of the steric hindrance of polyelectrolytes as well as the electrostatic repulsion between the polyelectrolytes and pore wall.

Carbon Fiber/Aluminum Composite Fabrication Using Wettability Control (젖음성 제어를 이용한 탄소섬유/알루미늄 복합재료 제조)

  • Lee, Yongbeom;Park, Sangjin;Han, Jun Hyun
    • Composites Research
    • /
    • v.28 no.5
    • /
    • pp.254-259
    • /
    • 2015
  • Carbon fiber/aluminum (CF/Al) composites were successfully fabricated without pressure casting using wettability modification of carbon fiber. The wettability of liquid aluminum on carbon fibers was enhanced through electroless plating of copper on carbon fibers. Liquid aluminum was well infiltrated into carbon fiber bundles with Cu coating layer due to low wetting angle, and a lot of pores that existed in CF/Al composite without Cu coating on CF were greatly removed. However, a few tiny pores existed in carbon fiber bundles, which is due to not bad wettability between CF and Al but shrinkage cavity that was generated during cooling of CF/Al composite. The tiny pores could be effectively removed by a subsequent rolling.

Evaluation of repeated measurement stability of dentition type of maxillary anterior tooth: an in vitro study (상악 전치의 치열 형태에 따른 스캔 반복 측정 안정성 평가: in vitro 연구)

  • Park, Dong-In;Son, Ho-Jung;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.41 no.3
    • /
    • pp.211-217
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the repeated measurement stability of scans related to dentition type. Methods: A normal model and the crowding and diastema models are also duplicated using duplicating silicon. After that, a plaster model is made using a plaster-type plaster on the duplicate mold, and each model is scanned 5 times by using an extraoral scanner. The gingival part and molar part were deleted from the 3D STL file data obtained through scanning. Using the 3D stl file obtained in this way, data is nested between model groups. Thereafter, RMS values obtained were compared and evaluated. The normality test of the data was performed for the statistical application of repeated measurements with dentition type, and the normality was satisfied. Therefore, the one-way ANOVA test, which is a parametric statistical method, was applied, and post-tests were processed by the Scheffe method. Results: The average size of each RMS in the Normal, Diastema, and Crowding groups was Normal> Crowding> Diastema. However, the standard deviation was in the order of Crowding> Normal> Diastema. The average value of each data is as follows. Diastema model was the smallest ($5.51{\pm}0.55{\mu}m$), followed by the crowding model ($12.30{\pm}2.50{\mu}m$). The normal model showed the maximum error ($13.23{\pm}1.06{\mu}m$). Conclusion: There was a statistically significant difference in the repeatability of the scanning measurements according to the dentition type. Therefore, you should be more careful when scanning the normal intense or crowded dentition than scanning the interdental lining. However, this error value was within the range of applicable errors for all clinical cases.

Effects of sonication on physicochemical properties and pore formation of maize starch (초음파처리가 옥수수전분의 이화학특성과 기공 형성에 미치는 영향)

  • Choi, Eun-Hee;Lee, Jae-Kwon
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.5
    • /
    • pp.507-512
    • /
    • 2017
  • The physicochemical properties of maize starch sonicated at various amplitudes (100, 200, and 300 W) and times (10, 30, and 50 min) were examined. The amount of enzyme-susceptible starch increased marginally after sonication. Sonication increased the amount of oil absorbed in the starch although the degree of oil absorption decreased with an extension of the sonication time, implied that different types and extent of damages occurred. Scanning electron microscopy revealed that ultrasound sonication did not form pores on the surfaces, but caused damages such as depression and erosion. Pasting viscosity of starch decreased with an increase in the severity of sonication conditions because of the weakened polymer network. X-ray diffraction suggested that the crystalline domains in starch were not susceptible to sonication and were more resistance to degradation. Sonicated starch formed more pin-holes on the surfaces in the initial glucoamylase reaction; subsequently, as the reaction proceeded, porous starch with enlarged pores was formed and finally, disrupted granular fragments were observed.

Heat treatment induced morphological changes of $Ca^{++}$ implanted single crystal $Al_2O_3$ ($Ca^{++}$를 implant한 단결정 $Al_2O_3$에서 열처리에 의한 형태학적 변화)

  • 김배연
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.3
    • /
    • pp.327-333
    • /
    • 1999
  • Controlled Ca impurity implanted inner crack-like pore in the high purity alumina bi-crystal had been created by micro-fabrication technique, which includes ion implantation, photo-lithography, Ar ion milling, and hot press. The morphological change and the growth od crystals formed by heat treatment in Ca doped high purity single crystal alumina, were observed using optical microscopy. The dot was developed and hexagon like crystal appeared on inner surface of crack-like pore after heat treatment. Bar type crystals, probably CaO . $6Al_2O_3$, were observed on the inner surface of 100ppm Ca implanted specimen after 1 hour heat treatment at $1,500^{\circ}C$, but this bar type crystal disappeared after 1 hour heat treatment at $1,600^{\circ}C$. This disappearance means that there should be little increase of Ca solubility limit to alumina and/or changes of diffusion coefficient of Ca in alumina around this temperature.

  • PDF

Polyethersulfone capillary membrane 모듐의 제조와 그 특성에 관한 연구

  • 김종엽;이광현;민병렬
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1994.04a
    • /
    • pp.34-35
    • /
    • 1994
  • Tube-in-orifice형태의 spinneret을 제작하여, polyethersulfone을 재질로 하는 capillary membrane을 건습식방사공정을 통해 제조하였다. 기공형성계는 PVP를, 용매는 NMP/DCM을, 내부응고제는 물과 NMP의 혼합물을, 외부응고제는 냉각수를 사용하였다. 내부응고제의 NMP농도에 따른 막의 형태와 microstructure를 연구하였다. 내부응고제가 약한 응고력을 가질 때 macrovoid가 없고, 내부의 활성층이 치밀한 막을 얻을 수 있었다. PES-NMP/DCM-PVP조성(25-44/11-20)의 용액으로, 40% NMP수용액을 내부응고제로 사용하여, 막을 제조하고 이를 모듈화하여, 한외여과실험을 한 결과, MWCO 8,000인 모듈이 얻어졌으며, 이 모듈의 Flux는 1기압에서 $1.44 \times 10^{-5}m/sec$이었다.

  • PDF