• Title/Summary/Keyword: 기계-유압식

Search Result 142, Processing Time 0.021 seconds

Study for the Design of Hydraulic Load Simulator (유압식 부하 시뮬레이터의 설계에 관한 연구)

  • 이성래;김형의;문의준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.44-52
    • /
    • 1994
  • Load simulator is essential to test and quality the performance of various control systems. It is good time to introduce a method to design and analyze the load simulator or since many research centers and industrial companies are trying to buy or design the load simulator. The stability, accuracy and response speed of the simulator are represented by the system parameters such as the hydraulic motor characteristics, the servovalve characteristics, supply pressure, rotational inertia, rotational spring constant, sensor and controller gains. Two design examples are shown here. A load simulator for a position control system and that for a velocity control system are designed. The goodness of the proposed method is verified by the digital computer simulations.

自動化의 重要性

  • 손명환
    • Journal of the KSME
    • /
    • v.20 no.2
    • /
    • pp.81-83
    • /
    • 1980
  • 자동화라는 것은 1788년에 유명한 James Watt의 증기기관에 있어서 조속기에서 처음으로 찾아볼 수 있다고 하며, 그후도 각종기기에서 부분적인 자동제어화된 예를 볼 수가 있다. 그러나, 현대 적이고 본질적인 자동화는 1914년에 Ford 자동차직립공장에서 흐름적립선을 설치하여 다량생산 방식의 근대산업을 개발하여 생산과정을 진정한 의미로 기계화하고 설인간화하였는데 있다고 하며 현대적감독의 자동화라는 말도 1946년에 출현한 transfer machine에 대하여 사용한 것이 처음이라고 한다 여하간 모든 산업에 있어서의 자동화는 현대산업발전의 촉진제로서 역할을 하여 획기적인 변혁을 가져왔고 경제발전의 원동력으로서의 자리를 굳혔을 뿐 아니라 설안간화, 성 력화의 단계를 넘어서 무인화의 영역에 도전하기에 이르렀다. 자동화 무인화의 영역에 도전하 기에 이르렀다. 자동화의 기술은 초기의 기계적방법을 거쳐서 유압식, 전기전자식으로 발전하였 으며, 현대과학기술의 정화인 전산기와 결합되어 종합과학기술로 발전하였고 앞으로 더욱 가속 화될 것이 기대된다.

  • PDF

Development of a Simulator of Vehicle Equipped with Mechanical Transmission and Hydraulic Accumulator Type-Braking Energy Regeneration System (유압 축압기식 제동에너지 희생시스템을 장착한 기계식 변속기 차량의 모의시험기 개발)

  • 이성래
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.180-186
    • /
    • 2004
  • The simulator of a vehicle equipped with mechanical transmission and hydraulic accumulator type-braking energy regeneration system is developed using a PC. The simulator receives the shift lever position, the accelerator pedal angle and the brake pedal angle generated by the operator using the keyboard, updates the state variables of the energy regeneration system responding to the input signals, and draws the moving pictures of the accumulator piston and pump/motor plate angle every drawing time on the PC monitor. Also, the operator can observe the shift lever position, the accel pedal angle, brake pedal angle, pressures of accumulators, vehicle speed, hydraulic torque, engine torque and air brake torque representing the operation of braking energy regeneration system through the PC monitor every drawing time. The simulator can be a very useful tool to design and improve the braking energy regeneration system.

A Study on the Droplet Size Distribution of Ultra High Pressure Diesel Spray on Electronic Hydraulic Fuel Injection System (전자유압식 분사계에 의한 초고압 디젤분무의 입경분포에 관한 연구)

  • Jang, S.H.;Ahn, S.K.
    • Journal of Power System Engineering
    • /
    • v.2 no.1
    • /
    • pp.25-30
    • /
    • 1998
  • In order to investigate the droplet size distribution and Sauter Mean Diameter in a ultra high pressure diesel spray, fuel was injected with ultra high pressure into the environments of high pressure and room temperature by an Electronic Hydraulic Fuel Injection System. Droplet size was measured with the immersion liquid sampling technique. The immersion liquid was used a mixture of water-methycellulose solution and ethanol. The Sauter Mean Diameter decreased with increasing injection pressure, with a decrease environmental pressure (back pressure) and nozzle diameter. Increasing the injection pressure makes the fuel density distribution of the spray more homogeneous. An empirical correlation was developed among injection pressure, air density, nozzle diameter and the Sauter Mean Diameter of spray droplets.

  • PDF

Sluice Gates Control Monitoring of Oil Pressure-Machine Using FDC Tuning Control Technique (FDC 동조제어기법을 이용한 유압-기계식 수문 제어 모니터링)

  • Heo, Gwanghee;Kim, Chunggil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4A
    • /
    • pp.337-342
    • /
    • 2010
  • Generally most sluice gates are closed and opened by a mechanical winch, a winch using an oil-pressure, or a winch mixing both. Because of their size and structure, they should be safely operated with more than two pulling devices helping each other. At the moment of their opening and closing, there usually occur some additional loads to the structure which cannot be exactly measurable at the stage of designing. Such additional loads can cause the sluice gate to be unbalanced and make it hard to open and close the gate, and by also overloading a winch, they can inflict a significant damage to the safety of the sluice gate. This paper explains a FDC(Force-Displacement Control) system which simultaneously considered the oil-pressure and displacement in order to evenly distribute the force and make a winch balanced at the opening and closing motion. This FDC system was implemented by means of the PID(Proportional Integral Derivative) function of XG 5000 program. It was experimented on a model of the sluice gate winch with the hydraulic oil pressure cylinder. The experiments showed that the developed FDC system made the winch of hydraulic oil pressure cylinder open and close cooperatively in spite of various external loads. Therefore the FDC system is proven effective when it is applied to a winch of sluice gate.

Modeling and Simulation of the Pneumatic Part in a Cold Gas Blow-Down Type Hydraulic Actuation System for a Missile (상온기체 블로우다운 방식을 사용한 유도무기용 유압식 구동장치의 공압부에 대한 모델링 및 시뮬레이션)

  • Park, Hee Seung
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.1-7
    • /
    • 2016
  • A cold gas blow-down hydraulic actuation system is widely used in missiles that require an actuation system with a fast response time under a limited space with a short operating time and large loads on the actuators. The system consists of a pneumatic part that supplies the regulated high-pressure gas to a reservoir, and a hydraulic part that supplies pressurized hydraulic oil to the actuators by the pressurized gas in the reservoir. This paper proposes a mathematical model to analyze and simulate the pneumatic part of an actuation system that supplies the operating power to the actuators. The mathematical model is based on the ideal gas equation and also considers the models for heat transfer. The model is applied to the pressure vessel and the gas part of the reservoir, and the model for the pneumatic part is established by connecting the two models for the parts. The model is validated through a comparison of the simulation results with the experimental results. The comparison shows that the suggested model could be useful in the design of the pneumatic part of a cold gas blow-down type hydraulic actuation system.

The Study of the Design of a Hydraulic Torque Load Simulator Equipped with a Direct Drive Servo Valve and a Feed forward Compensator (직접 구동형 서보밸브와 전진 보상기를 적용한 유압식 토크 부하 시뮬레이터의 설계에 관한 연구)

  • Lee, Seong Rae
    • Journal of Drive and Control
    • /
    • v.15 no.1
    • /
    • pp.16-27
    • /
    • 2018
  • Hydraulic torque load simulator is essential to test and qualify the performance of various angle control systems. Typically a flapper-type second stage servovalve is applied to the load simulator, but here the direct drive servovalve, which is a kind of one-stage valve and affected by the large flow force, is applied. Since the torque load is applied not to the stationary shaft but to the rotating shaft of the angle control system, the controlled torque of load simulator is not accurate due to the rotating speed of the angle control system. A feedforward compensator is designed and applied to minimize the disturbance-like effect. A mathematical model is derived and linearized to analyze the stability, accuracy and responsiveness of the torque load simulator. The parameter effects of a controller, servovalve, hydraulic motor, rotating spring shaft are analyzed and summarized. The goodness of the linear analysis is verified by the digital computer simulations using both the linear and nonlinear mathematical models.

A Case Study on Failure and Analysis of Air Over Hydraulic Brake Line (공기 유압식 브레이크 라인 파손 사례 및 파손 분석 연구)

  • Park, Jeongman;Park, Jongjin
    • Journal of Auto-vehicle Safety Association
    • /
    • v.12 no.2
    • /
    • pp.47-55
    • /
    • 2020
  • In this case study, the brake line failure of air over hydraulic(AOH) brake system is described. AOH brake system is applied to commercial vehicles between 5 to 8 tons. It consists of a hydraulic system using compressed air and operates the air master to form hydraulic pressure to transfer braking power to the wheels. When the brake lines of the system applied to vehicles with high load capacity are damaged, the braking force of one shaft is lost, and the braking distance increases rapidly, leading to a big accident. Failure of the brake line occurs due to various causes such as road surface fragmentation, corrosion of the line, and aged deterioration of air brake hose. The braking force could be decreased even when a very small break in the form of a pin-hole occurs. However, it is difficult to find a part where the thickness of the line is thin due to stone pecking or corrosion generated in the pin-hole formed on the brake line located under the lower part of the vehicle by the sensory evaluation or the conventional braking force test. Accordingly, it is necessary to analyze the condition and cause of the failure of the brake line more precisely when the accident investigation of the heavy vehicles, and also to examine the necessity of the advanced test for the aged brake line.

An Experimental Research of Servo Valve Offset Correction Method of Hydraulic Actuator (유압식 구동장치의 서보밸브 오프셋 보정 방법에 관한 실험적 연구)

  • Ban, Joon Hyeok
    • Journal of Drive and Control
    • /
    • v.16 no.2
    • /
    • pp.72-79
    • /
    • 2019
  • Despite the development of electronic components and microprocessors, hydraulic actuators are still being applied in various applications. In some applications, there is a desire to apply a hydraulic actuator with a relatively small position error to the system. Various studies have been conducted to reduce the position error of hydraulic actuators. In this paper, the position error of the hydraulic actuator when the hydraulic oil pressure is supplied is defined as the offset generated by the servo valve, and the method for correcting the servo valve offset has been studied. A method for compensating the servo valve offset was proposed and it was verified through experiments that the position error of the hydraulic actuator was reduced. We also compared the servo valve offset correction method and controller using the PID control and disturbance observer used to reduce the position error of the hydraulic actuator. No-load test and load test were performed to confirm the performance of the servo valve offset correction method. The results of the study were compared with those obtained by using the disturbance observer and PID control.