• Title/Summary/Keyword: 기계화

Search Result 5,224, Processing Time 0.031 seconds

The Effect of Pressure and Hose Length on the Travelling Distance of Particles in Power Sprayer (토출압력(吐出壓力) 및 호오스길이가 도달성(到達性)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Kwon, Soon Hong;Choi, Kyu Hong
    • Journal of Biosystems Engineering
    • /
    • v.7 no.2
    • /
    • pp.30-35
    • /
    • 1983
  • To investigate the factors affecting the transportability of spray droplets, the maximum distance, the effective distance, the ratio of even distribution, and the diameters of particles were measured in accordance with the different pressure levels of power sprayer using 3 hole swath type nozzle, and the results are summerized as follows; 1. The distance of the most dense point from the nozzle was shortened by 0.5 meter with the 100-meter-long hose. The maximum reaching distances were reduced by 1.5 and 1.0 meters for the 13m/m and the 8.5 m/m hoses respectively, and the effective distance were reduced by 0.5 meter for both cases. 2. The effective distance can not be extended beyond 14 meters even if the length of hose is minimized at the rated pump pressure 28 kg/$cm^2$, it was 1 meter longer for 13m/m hose compared to the 8.5m/m one. 3. In case of 13m/m hose, the most dense point can be extended further by 0.5 meter increasing the pump pressure by 8 kg/$cm^2$, and the maximum distance and effective distance were increased by 2.0 and 0.5 meters respectively. There was no significant effect of pressure changes on the transportability in case of 8.5m/m hose. 4. Both the reduction of hose length and the increase of pump pressure influenced in large extent to the atomization effect of droplets. It was noticed that the diameter of droplet is related to the pump pressure and inside diameter of hose. 5. The pressure drop in 100-meter-long and l3m/m hose was 5~7kg/$cm^2$ at the pump pressure range of 25~33kg/$cm^2$, and it is an equivalent of 2% per 10 meter length of hose.

  • PDF

A Clinical Study of Aseptic Meningitis in the Busan Area in 2002 (2002년 부산 지역에서 유행한 무균성 뇌막염에 대한 임상적 고찰)

  • Park, Ji Hyun;Lee, Na Young;Kim, Gil Hyun;Jung, Jin Hwa;Cho, Kyung Soon;Kim, Sung Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.9
    • /
    • pp.858-864
    • /
    • 2003
  • Purpose : There was a outbreak of aseptic meningitis in Busan, 2002. We report the clinical features and causative viruses. Methods : Two hundred seventy six children with aseptic meningitis who were admitted to the Department of Pediatrics, Maryknoll Hospital between January and December, 2002 were included. CSF, stool and throat swab viral cultures were done in 244 of these children. Results : The male to female ratio was 1.4 : 1. Age of patients varied from five months to fourteen years old. Average age was $5.7{\pm}6.2years$ old and mostly between one and four years.(41.3%) Monthly distribution revealed that the number of patients increased from May to July. The main symptoms were fever, headache and vomiting in this order. Respiratory tract infection symptom was associated from June to July and headache and nausea without fever were characteristically observed in children more than 10 years old from November to December. In peripheral blood examination, leukocytosis(WBC>$10,000/mm^3$) showed in 34.8%, ESR was increased in 56.1%, and CRP was positive value in 61%. Therefore differential diagnosis was difficult through peripheral blood examination. CSF findings revealed mean leukocyte count $86.5{\pm}180.2/mm^3$, protein $41.7{\pm}32.9mg/dL$, glucose $56.4{\pm}9.9mg/dL$. Median hospitalized period was $4.7{\pm}7.2days$ and compared with non-tapping group, hospitalized period was shorter and subsidance of symptoms was faster, therefore antibiotics injection period was shorter in the spinal tapping group. Virus was isolated in 31 cases of 244. The causative agents were echovirus 6, echovirus 9, echovirus 25, coxsakie virus B3, B4. Conclusion : There was an epidemics of aseptic meningitis in Busan, 2002; the causative agent was echovirus 6, 9, 25, coxsakie virus B3, B4.

Effect of surfactant lavage in severe meconium aspiration syndrome (중증 태변 흡인 증후군에서 인공 폐표면활성제 세정요법의 효과에 관한 비교 연구)

  • Lee, Soon Min;Kim, He Min;Jeon, Ji Hyun;Park, Min Soo;Park, Kook In;Namgung, Ran;Lee, Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.367-371
    • /
    • 2008
  • Purpose : The surfactant dysfunction may play an important role in meconium aspiration syndrome (MAS). We aim to evaluate the effect of surfactant lavage in the treatment of term infants with MAS. Methods : The medical records of 15 neonates with severe MAS admitted at Yongdong Severance Hospital from 2005 to 2007 were reviewed and analyzed. Seven infants with severe MAS necessitating mechanical ventilation underwent tracheobronchial lavage with 20 mL/kg of diluted (5.3 mg phospholipid/mL) surfactant saline suspension ($Newfactan^{(R)}$). Data regarding clinical outcomes was assessed by comparison with 8 control infants with equally severe MAS retrospectively. Results : In the lavage group, radiological improvement was evident after 6 hours of treatment. The duration of artificial ventilation and duration of hospital day were also significantly shorten in the lavage group compared with the control group. The mean oxygen index, mean ventilation index improved significantly within the first 6 hours after treatment. No differences were found in the incidence of major complications and mortality between the two groups. Conclusion : The surfactant lavage seems to be an effective and safe method for treatment of severe MAS. A multicenter, large scaled randomized controlled trial is needed for further study.

A Study on Automatic Classification Model of Documents Based on Korean Standard Industrial Classification (한국표준산업분류를 기준으로 한 문서의 자동 분류 모델에 관한 연구)

  • Lee, Jae-Seong;Jun, Seung-Pyo;Yoo, Hyoung Sun
    • Journal of Intelligence and Information Systems
    • /
    • v.24 no.3
    • /
    • pp.221-241
    • /
    • 2018
  • As we enter the knowledge society, the importance of information as a new form of capital is being emphasized. The importance of information classification is also increasing for efficient management of digital information produced exponentially. In this study, we tried to automatically classify and provide tailored information that can help companies decide to make technology commercialization. Therefore, we propose a method to classify information based on Korea Standard Industry Classification (KSIC), which indicates the business characteristics of enterprises. The classification of information or documents has been largely based on machine learning, but there is not enough training data categorized on the basis of KSIC. Therefore, this study applied the method of calculating similarity between documents. Specifically, a method and a model for presenting the most appropriate KSIC code are proposed by collecting explanatory texts of each code of KSIC and calculating the similarity with the classification object document using the vector space model. The IPC data were collected and classified by KSIC. And then verified the methodology by comparing it with the KSIC-IPC concordance table provided by the Korean Intellectual Property Office. As a result of the verification, the highest agreement was obtained when the LT method, which is a kind of TF-IDF calculation formula, was applied. At this time, the degree of match of the first rank matching KSIC was 53% and the cumulative match of the fifth ranking was 76%. Through this, it can be confirmed that KSIC classification of technology, industry, and market information that SMEs need more quantitatively and objectively is possible. In addition, it is considered that the methods and results provided in this study can be used as a basic data to help the qualitative judgment of experts in creating a linkage table between heterogeneous classification systems.

Analysis of Fluidization in a Fluidized Bed External Heat Exchanger using Barracuda Simulation (바라쿠다 시뮬레이션을 이용한 유동층 외부 열교환기의 유동해석)

  • Lee, Jongmin;Kim, Dongwon;Park, Kyoungil;Lee, Gyuhwa
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.642-650
    • /
    • 2020
  • In general, the circulation path of the fluidized particles in a CFB (Circulating Fluidized Bed) boiler is such that the particles entrained from a combustor are collected by a cyclone and recirculated to the combustor via a sealpot which is one of non-mechanical valves. However, when a fluidized bed heat exchanger (FBHE) is installed to additionally absorb heat from the fluidized particles, some particles in the sealpot pass through the FBHE and then flow into the combustor. At this time, in the FBHE operated in the bubbling fluidization regime, if the heat flow is not evenly distributed by poor mixing of the hot particles (800~950 ℃) flowing in from the sealpot, the heat exchanger tubes would be locally heated and then damaged, and the agglomeration of particles could also occur by formation of hot spot. This may affect the stable operation of the circulating fluidized bed. In this study, the unevenness of heat flow arising from structural problems of the FBHE of the domestic D-CFB boiler was found through the operating data analysis and the CPFD (Computational Particle Fluid Dynamics) simulation using Barracuda VR. Actually, the temperature of the heat exchanger tubes in the FBHE showed the closest correlation with the change in particle temperature of the sealpot. It was also found that the non-uniformity of the heat flow was caused by channeling of hot particles flowing in from the sealpot. However, it was difficult to eliminate the non-uniformity even though the fluidizing velocity of the FBHE was increased enough to fluidize hot particles vigorously. When the premixing zone for hot particles flowing in from the sealpot is installed and when the structure is changed through the symmetrization of the FBHE discharge line for particles reflowing into the combustor, the particle mixing and the uniformity of heat flow were found to be increased considerably. Therefore, it could be suggested that the structural modification of the FBHE, related to premixing and symmetric flow of hot particles, is an alternative to reduce the non-uniformity of the heat flow and to minimize the poor particle mixing.

Oseltamivir efficacy, side effects, and safety in children with influenza (인플루엔자 바이러스 감염 소아 환아에서 Oseltamivir 약제 효용성과 단기간.장기간 부작용 및 안전성에 관한 임상연구)

  • Seo, Eun Sun;Park, Geun Hwa;Kim, Sung Mi;Kim, Sung Won;Jung, Woo Sik;Cho, Kyung Soon;Park, Yeon Gyeong;Lee, Chang Kyu;Kang, Chun;Lee, Joo Yeon;Choi, Woo Young
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.1
    • /
    • pp.56-66
    • /
    • 2010
  • Purpose : Although oseltamivir is widely used for treatment of influenza, few clinical studies of its efficacy and resistance have been performed in Korea. We evaluated the safety, side effects, and efficacy of oseltamivir treatment in Korean pediatric patients. Methods : We analyzed 321 children diagnosed with influenza at Busan St. Mary's Medical Center, Korea, between January 2008 and June 2008 (first study period) and November 2008 and January 2009 (second study period). Patients were divided into two groups: those receiving oseltamivir treatment for 5 days and those receiving only symptomatic treatment. We investigated clinical symptoms, side effects, and resistance to oseltamivir. We also identified influenza strains and evaluated resistance to oseltamivir using an influenza virus culture. Results : One hundred eighty-six patients were assigned to the treatment group, and 135 were assigned to the control group. The treatment group showed shorter admission duration (4.4 days) compared with controls (5.0 days) (P =0.000) and had fewer lower respiratory tract complications compared with controls (P <0.05). No significant statistical difference in the virus antigenic type was observed between the groups. In the first study period, virus culture showed influenza B (41.7% vs. 49.6%), A/H3N2 (7.9% vs. 8.4%), and A/H1N1 (9.4% vs. 6.5%). In the second study period, only A/H1N1 (55.3% vs. 50.0%) was isolated, except for one case of A (H3N2) in the treatment group. No differences in short- and long-term side effects, including neuropsychologic side effects, were noted between groups. There was no resistance to oseltamivir before or after treatment in the first study period. Conclusion : Based on our results, we suggest that osetalmivir therapy in pediatric patients is effective.

Development and Animal Tests of Prototype Oxygen Concentrator (국산 산소 농축기의 개발 및 동물실험)

  • 변정욱;성숙환;이태수
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.643-649
    • /
    • 1998
  • Background: For the patient with chronic obstructive pulmonary disease requiring long-term oxygen therapy, oxygen concentrator machines are already widely available for use in home. In this study, we used mongrel dogs as test subjects to compare the functional efficiency and safety of the oxygen concentrator developed by our own research team with those of the imported FORLIFE(TM) machine made by AIRSEP Corp. Method and method: To test mechanical reliability, the concentrations of oxygen delivered were measured after 4 hours of continuous operation. Sixteen mongrel dogs were divided into two equal groups. Mongrel dogs in group A were given oxygen using the imported oxygen concentrator, and those in group B using the machine developed. 5 l/min of oxygen were given, after which vital signs were analyzed, arterial blood gases measured, and blood chemistry tests carried out. Results: After 4 hours of continuous operation, the imported model performed better, giving 98${\pm}$3% oxygen, compared to our model, which gave 91${\pm}$1%. In the animal experiments, oxygen concentrations were measured at the inlet of face mask 1, 2, 3, and 4 hours after continuous administration, and there was no statistically significant difference(repeated measures of analysis of variance p=0.70) between the values of 70.6${\pm}$2.5%, 67.1${\pm}$2.9%, 68.2${\pm}$2.6%, and 64.9${\pm}$3.9% that were measured from group A, and the values of 65.1${\pm}$4.8%, 65.2${\pm}$3.6%, 68.7${\pm}$4.3%, and 66.0${\pm}$5.0% measured from group B. Before oxygen administration, and at 1, 2, 3, and 4 hours after oxygen administration, arterial blood partial pressure of oxygen 87.2${\pm}$2.5 mmHg, 347.4${\pm}$29.3 mmHg, 353.4${\pm}$21.2 mmHg, 343.0${\pm}$28.8 mmHg, and 321.6${\pm}$24.4 mmHg, respectively, were read from group A, which were not statistically different (p=0.24) to the values of 102.5${\pm}$9.6 mmHg, 300.3${\pm}$17.1 mmHg, 321.6${\pm}$23.7 mmHg, 303.4${\pm}$27.4 mmHg, and 273.5${\pm}$25.9 mmHg read from group B. Nonetheless, the arterial blood partial pressure of oxygen values appear to be somewhat higher in dogs that were given oxygen using the imported oxygen concentrator. Conclusions: From these results the prototype oxygen concentrator developed appears to function relatively satisfactorily compared to the imported, established model, but may be criticized for the excessive noise generated and poor long-term endurance or consistency, which need improvement.

  • PDF

Clinical Benefits and Complications of Cryotherapy in Advanced Lung Cancer with Central Airway Obstruction (중심성 기도 폐쇄를 동반한 폐암에서 냉동치료의 임상적 유용성 및 부작용)

  • Jung, Jin Yong;Lee, Sung Yong;Kim, Dae Hyun;Lee, Kyung Joo;Lee, Eun Joo;Kang, Eun Hae;Jung, Ki Hwan;Kim, Je Hyeong;Shin, Chol;Shim, Jae Jeong;In, Kwang Ho;Kang, Kyung Ho;Yoo, Se Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.4
    • /
    • pp.272-277
    • /
    • 2008
  • Background: The efficacy of the use of the interventional bronchoscope for palliation of patients with central airway obstruction has been established. In the palliative setting to alleviate central airway obstruction, the use of laser resection, electrocautery, argon plasma coagulation, photodynamic therapy and cryotherapy can provide relief of an airway obstruction. Cryotherapy is the therapeutic application of extreme cold for the local destruction of living tissue. Recently, this technique has been used for endoscopic management of central airway obstructions in Korea. We report the role and complications of the use of cryotherapy for airway obstructions in patients with advanced lung cancer. Methods: We used a flexible cryoprobe for cryotherapy using nitrous oxide as a cryogen. The cryoprobe was applied through the working channel of a flexible fiberoptic bronchoscope. The temperature of the tip was approximately $-89^{\circ}C$, and the icing time was 5~20 seconds. Results: Four patients with a central airway obstruction from advanced lung cancer were treated with cryotherapy. Three of the four patients were treated successfully and the airway obstruction was improved after the cryotherapy procedure. Dyspnea, hypoxia and atelectais were improved in three cases. Two patients experienced complications- one patient experienced pneumomediastinum and the other patient experienced massive hemoptysis during the cryotherapy procedure. However, these complications resolved and did not influence mortality. Conclusion: This technique is effective and relatively safe for palliation of inoperable advanced lung cancer with a central airway obstruction.

Empirical Survey for the Evaluation of Content Relevance in the 7th Technology & Home Economics Subject (제7차 기술$\cdot$가정 교육내용 적정성 평가 - 가정과교육 영역을 중심으로 -)

  • Wang Seok-Soon
    • Journal of Korean Home Economics Education Association
    • /
    • v.17 no.4 s.38
    • /
    • pp.133-156
    • /
    • 2005
  • This study clarifies the concept of the education content relevance in order to evaluate the content relevance of Technology & Home Economics in a secondary school, and design its standards based on the preceding study. In other words, four standards such as the amount of studying content, the degree of difficulty, the validity of contents and the sequence of contents are established. Also, a survey on the current status of nationwide units targeting students, teachers, and professors was conducted to collect actual data about relevance evaluation. The results are as follows. First, as for the evaluation in terms of the amount of studying content, the majority of respondents answered that it decreased by about $30\%$ when compared to the 6th Technology & Home Economics Curriculum However, middle school teachers pointed out that the number of classes is not enough considering the fact that it's an activity-oriented subject. So, they acknowledged that the amount of study time during a Technology Sl Home Economics class is 'quite a lot.' Second, the evaluation in the degree of difficulty is divided into two responses. Teachers responded that it's reasonable overall, but according to students, it's difficult. Especially, the chapters that students don't understand well including 'The Elements of Draftsmanship,"' 'Understanding of Machinery,' 'Electronics & Electricity Technology,' and 'Energy & Transportation Technology.' In the Home Economics area, 'The Design of Home Life' is the only chapter that students don't understand well. Third, as for the validity of contents, the chapters that were not considered as important considering the objective of Technology Sl Home Economics Curriculum include 'The Elements of Draftsmanship,' 'Computer & Processing,' and 'The Management of Resources and Environment.' Fourth, as for the sequence of contents, the survey was conducted including the name of the course asone of the survey items. The majority of teachers wanted it as it is, but the Professors of education colleges who wanted the 3rd name to connect the course with the elementary school course was a little more $(50.5\%)$ than the ones who don't want any changes $(45.5\%)$. The follow-up study should correct and complement the standards that this study suggested through analytic and critical review according to the character & goal of the subject. Based on such standards, the evaluation of content relevance should be continued to realize the quality control of the curriculum systematically.

  • PDF

The Effects on Dose Distribution Characteristics by Changing Beam Tuning Parameters of Digital Linear Accelerator in Medicine (의료용 디지털 선형가속기의 빔조정 인자변화가 선량분포특성에 미치는 영향)

  • 박현주;이동훈;이동한;권수일;류성렬;지영훈
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 1999
  • INJ-I, INJ-E, PFN, BMI, and PRF were selected among the various factors which constitute a digital linear accelerator to find effects on the dose distribution by changing current and voltage within the permitted scale which Mevatron automatically maintained. We measured the absorbed dose using an ion chamber, analyzed the waveform of beam output using an oscilloscope, and measured symmetry and flatness using a dosimetry system. An RFA plus (Scanditronix, Sweden) device was used as a dosimetry system. Then an 0.6cc ion chamber (PR06C, USA), an electrometer (Capintec192, USA), and an oscilloscope (Tektronix, USA) were employed to measure the changes on the dose distribution characteristics by changing the beam-tuning parameters. When the currents and the voltages of INJ-I, INJ-E, PFN, BMI, and PRF were modified, we were able to see the notable change on the dose rate by examining the change of the output pulse using the oscilloscope and by measuring them using the ion chamber. However, the results of energy and flatness graph from RF A plus were almost identical. The factors had fine differences: INJ-I, INJ-E, PFN, BMI, and PRF had 0.01∼0.02% differences in D10/D20, 0.1∼0.2 % differences in symmetry, and 0.1∼0.4% differences in flatness. Since Mevatron controlled itself automatically to keep the reference value of the factor, it was not able to see large differences in the dose distribution. There were fine differences on the dose rate distribution when the voltage and the currents of the digitized factors were modified Nonetheless, a basic operational management information was achieved.

  • PDF