• Title/Summary/Keyword: 기계적자극

Search Result 97, Processing Time 0.031 seconds

Effects of Joint Mobilization Techniques on the Joint Receptors (관절 가동운동이 관절 감수기에 미치는 영향)

  • Kim, Suhn-Yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.2 no.1
    • /
    • pp.9-19
    • /
    • 1996
  • Type I, II, III are regarded as "true" joint receptors, type IV is considered a class of pain receptor. Type I, II and III mechanoreceptors, via static and dynamic input, signal joint position, intraarticular pressure changes, and the direction, amplitude, and velocity of joint movements. Type I mechanoreceptor subserve both static and dynamic physiologic functions. Type I are found primarily in the stratum fibrosum of the joint capsule and ligaments. Type I receptors have a low threshold for activation and are allow to adapt to changes altering their firing frequency. Type II receptors have a low threshold for activation. These dynamic receptors respond to joint movement. Type II receptors are thus termed rapidly adapting. Type II joint receptors are located at the junction of the synovial membrane and fibrosum of the joint capsule and intraarticular and extraarticular fat pads. Type III receptors have been found in collateral ligaments of the joints of the extremities. Morphologically similar to Golgi tendon organ. These dynamic receptors have a high threshold to stimulation and are slowly adating. Type IV receptors possess free nerve ending that have been found in joint capsule and fat pads. They are not normally active, but respond to extreme mechanical deformation of the joint as well as to direct chemical or mechanical irritation. Small amplitude oscillatory and distraction movements(joint mobilization) techniques are used to stimulate the mechanoreceptors that may inhibit the transmission of nociceptors stimuli at the spinal cord or brain stem levels.

  • PDF

A NEW CONCEPT FOR ORTHODONTIC THERAPY

  • Yang, Sang-Deok
    • The Journal of the Korean dental association
    • /
    • v.26 no.5 s.228
    • /
    • pp.441-456
    • /
    • 1988
  • 지난 수 십년간 기계적인 측면에서의 교정장치나 치료술식은 급속한 발전을 하여왔으나 생물학적 관점에서의 현대 교정학은 아직도 낙후된 수준에 머물러 있다. 이러한 관점에서 기초의학을 기반으로 세포의 생물학적 잠재력을 극대화시켜 임상적 효율성을 증진시키기 위한 일련의 연구들이 진행되고 있다. 그중에서 전기적 자극에 의한 골성장기전의 개념을 이용하는 분야는 가장 활발히 연구되고 있는 분야 중의 하나이다. 전기자극 중 가장 유용한 수단인 전자기장 이용법의 발달과정에 대해 알아보고 전기적 자극에 의한 골세포 반응의 작용기전에 대한 많은 자료를 종합, 분석하여 그 가설적인 모형을 세우고 아울러 교정 임상에서 이러한 개념의 적용가능성과 그 범위에 대해 조명해 본다. 앞으로 이 분야에 대한 계속적인 연구로 머지않아 실제 임상에 활용되는 단계에 이르게 되길 기대한다.

  • PDF

Effects of compressive stress on the expression of M-CSF, IL-$1{\beta}$, RANKL and OPG mRNA in periodontal ligament cells (압박력이 치주인대 세포의 M-CSF, IL-$1{\beta}$, RANKL 및 OPG mRNA 발현에 미치는 영향)

  • Kim, Ji-Woong;Lee, Ki-Soo;Nahm, Jong-Hyun;Kang, Yoon-Goo
    • The korean journal of orthodontics
    • /
    • v.39 no.4
    • /
    • pp.248-256
    • /
    • 2009
  • Objective: The aim of this study was to determine if human PDL cells can produce osteoclastogenic mRNA and examine how compressive stress affects the expression of osteoclastogenic mRNA in human PDL cells. Methods: Human PDL cells were obtained from biscupids extracted for orthodontic treatment. The compressive force was adjusted by increasing the number of cover glasses. PDL cells were subjected to a compressive force of 0.5, 1.0, 2.0, 3.0 or $4.0\;g/cm^2$ for 0.5, 1.5, 6, 24 or 48 hours. Reverse transcription polymerase chain reaction (RT-PCR) analysis was performed to examine levels of M-CSF, IL-$1{\beta}$, RANKL, OPG mRNA expression. Results: Human PDL cells could produce M-CSF mRNA. Human PDL cells under compressive stress showed increased M-CSF, IL-$1{\beta}$ and RANKL mRNAs expression in a force (up to $2\;g/cm^2$) and time-dependent manner. However, OPG mRNA expression was constant regardless of the level and duration of stress. Conclusions: Continuous compressive stress induced the mRNA expression of osteoclastogenic cytokines including M-CSF, RANKL, IL-$1{\beta}$ in PDL cells. Together with an unchanged OPG mRNA level, these results suggest that compressive stress-induced osteoclastogenesis in vivo is partly controlled by M-CSF, RANKL and IL-$1{\beta}$ expression in PDL cells.

Role of Ultrasound in Acupuncture (침술에서 초음파의 역할)

  • Park, Gi-Young
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.94-98
    • /
    • 2009
  • Acupuncture is a treatment method that originated more than 3,000 years ago in China and is practiced in most of the world. Acupuncture became the most popular complementary and alternative medicine modality. Ultrasound is useful for research and educational purposes, visualizing needle insertion at acupuncture points, especially next to vulnerable structures such as nerves or the pleura. Additionally, ultrasound is an ideal imaging method for evaluation the biomechanical effects of needle manipulation on tissue and has the distinctive advantage of yielding both images of tissue morphology and biomechanical information. Elastography take aim at quantifying a mechanical response or the mechanical property of tissues from a mechanical stimulus, generated internally or externally. Therefore, the combination of ultrasound and elastography analyses allows quantitative assessment of dynamic changes in the structure of human connective tissue.

  • PDF

The Dynamic and Histologic Changes of Variously Fixed Bovine Pericardiums Specimens after Mechanical Fatigue Stimuli (다양한 고정 처리법을 이용한 소 심낭의 기계적 피로 자극 후 역학적 및 조직학적 변화)

  • Chang, Hyoung-Woo;Kim, Yong-Jin;Kim, Soo-Hwan;Park, Ji-Eun;Park, Chun-Soo;Kim, Woong-Han;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.148-156
    • /
    • 2009
  • Background: As cardiovascular operations become more complex and sophisticated, there is an increasing need for various bioprostheses for use as components of blood vessels and heart valves. We developed a fatigue stimuli test instrument to objectively evaluate the mechanical durability of a bioprosthesis, and we tested several currently known processing methods for bovine pericardium and we then compared the results. Material and Method: Fresh bovine pericardium was collected at the butcher shop with using aseptic technique, and each piece of pericardium was fixated and/or decellularized by 16 representative methods. We measured the permeability and compliance of the processed bovine pericardium samples, and measured them again after exposure to the fatigue stimuli. All the pieces of pericardium underwent microscopic examinations before and after the fatigue stimuli. Result: A mixture of glutaraldehyde and solvent treatment showed better mechanical durability than did the single glutaraldehyde treatment. High concentration glutaraldehyde treatment showed equal or no worse results than did low concentration glutaraldehyde treatment. After SDS (sodium dodecylsulfate) decellularization, the mechanical property of the bioprosthesis became much worse ($20{\sim}190$ times) and the mechanical durability to the fatigue stimuli was also very poor. Conclusion: We obtained the basic durability data after various fixation methods with using a home-made fatigue test instrument.

Recent Research Trend in Skin-Inspired Soft Sensors with Multimodality (피부 모사형 다기능 유연 센서의 연구 동향)

  • Lee, Seung Goo;Choi, Kyung Ho;Shin, Gyo Jic;Lee, Hyo Sun;Bae, Geun Yeol
    • Journal of Adhesion and Interface
    • /
    • v.21 no.4
    • /
    • pp.162-167
    • /
    • 2020
  • The skin-inspired multimodal soft sensors have been developed through multidisciplinary approaches to mimic the sensing ability with high sensitivity and mechanical durability of human skin. For practical application, although the stimulus discriminability against a complex stimulus composed of various mechanical and thermal stimuli experienced in daily life is essential, it still shows a low level actually. In this paper, we first introduce the operating mechanisms and representative studies of the unimodal soft sensor, and then discuss the recent research trend in the multimodal soft sensors and the stimulus discriminability.

EFFECT OF MAGNETIC FIELD STRUCTURE NEAR CATHODE ON THE ARC SPOT STABILITY OF FILTERED VACUUM ARC SOURCE OF GRAPHITE (자장 여과 진공 아크 소스에서 음극 부근의 자기장에 따른 아크 스팟 안정성 연구)

  • 김종국;이광렬;은광용;정기형
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.138-138
    • /
    • 1999
  • 자장 여과 진공 아크법(Filtered Vacuum Arc :FVA)에 의해 증착된 비정질 다이아몬드 박막은 기계적, 광학적 특성이 매우 우수하여 많은 연구자들의 관심의 대상이 되어 왔다. 그러나 아크의 불안정성은 자장 여과 아크 소스의 연속적인 운전을 제한하고, 결과적으로 낮은 생산성을 가져왔다. 본 연구에서는 음극의 형태 및 음극 부근에서의 자기장의 구조를 음극 부식 거동의 관점에서 수치모사 및 실험을 통해서 조사하였다. 소스 전자석과 인출 전자석의 자극 방향이 평행하게 된 구조에서 (magnetic mirror configuration), 음극 후면에 반대 방향의 자극을 가지는 영구자석을 돔으로서 아크 불안정성을 억제할 수 있었다. 또한 소스 전자석에 진동하는 전류를 인가함으로써 아크 스팟의 운동 면적을 효과적으로 확장할 수 있었다. 시간 변화에 따른 빔 전류의 변화로부터 테이프형 음극이 우물형 음극에 비하여 더 안정하다는 것을 확인하였다. 진동하는 소스 전자석의 전류와 직경 80mm의 테이퍼형 음극을 사용하여, 아크 전류 60A에서 약 2000분 동안 사용하였으며, 이때 부식된 부피는 사용 가능한 음극 부피의 약 90%였다. 그리고 약 350mA의 안정한 빔 전류를 현재의 조건에서 얻었다.

  • PDF

기능적 자기공명영상 및 확산텐서영상을 이용한 전음성 난청과 감각신경성 난청군의 비교 연구: 예비 결과

  • 이재준;황문정;이영주;김인성;배성진;장용민;이상흔;우성구;강덕식
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.94-94
    • /
    • 2003
  • 목적: 기능적 자기공명영상과 확산텐서영상기법을 이용하여 전음성 난청과 감각신경성 난청에서의 뇌활성화 양상 그리고 청신경경로상의 차이점을 비교 연구하고자 하였다. 대상 및 방법: 전음성 난청군 (n=4)과 감각신경성 난청군(n=5) 그리고 정상군(n=5)에서의 기능적 자기 공명영상과 확산텐서영상을 획득하였다. 기능적 자기공명영상의 경우 1.5T Siemens MR scanner에서 BOLD 기법을 이용하여 500 Hz 순음 청각자극에 대한 뇌활성화 영역을 검출하였고 영상촬영시 발생하는 기계적 소음을 차폐하기 위한 청각자극기를 특별히 제작하여 사용하였다. 뇌백질신경로를 영상화하는 확산텐서영상은 3.0T GE whole body MR scanner를 사용하였으며 미세한 확산운동을 검출하기 위해 초고속 영상기법인 EPI 기법을 사용하였다. 영상의 화질을 높이기 위해 공간적으로 25개의 다른 방향으로 확산경사자장을 가하였다. 청신경로의 비등방성 영상, 신경로 방향 영상등을 구현하기 위해 획득한 확산영상들에 대한 영상 후처리과정을 시행하였다.

  • PDF