• Title/Summary/Keyword: 기계심장판막

Search Result 127, Processing Time 0.033 seconds

Clinical Analysis of St. Jude Medical Prosthesis (St. Jude Medical 기계판막의 임상적 연구)

  • 최순호
    • Journal of Chest Surgery
    • /
    • v.24 no.2
    • /
    • pp.171-181
    • /
    • 1991
  • Result of St. Jude Medical valve replacement are presented in 106 patients who underwent operation from January 1985 through July 1989. The patient were 52 males and 56 females. Total 136 of St. Jude Medical valves were implanted; 91 in mitral position, 45 in aortic position. The hospital mortality rate was 5.7%o[6 patients] and the late mortality rate was 2.0%[2 patients]. The causes of death were low cardiac output in 5, iatrogenic right ventricular rupture in 1, heart failure in 1, ventricular arrhythmia in l. And, the causes of valve related complication were anticoagulant related hemorrhage in 5 patients[0.03% /patient-year] and thromboembolism[0.01% /patient-year] in 2 patients. In conclusion, the performance of the St. Jude Medical valve compare most favorably with other artificial valves. But it remains still hazards of mechanical prosthesis such as thromboembolism and anticoagulant related hemorrhage.

  • PDF

A Numerical Analysis on the Motion of a Curved Bileaflet in Mechanical Heart Valve(MHV) and the Characteristics of Blood Flow in an Elastic Blood Vessel (탄성혈관 내 곡면형 이엽 기계식 인공심장판막의 거동 및 혈액 유동 특성에 관한 수치해석적 연구)

  • Bang J. S.;Choi C. R.;Kim C. N.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.203-206
    • /
    • 2004
  • In this study, a numerical analysis has been performed for a three-dimensional pulsatile blood flow associated with the elastic blood vessel and curved bileaflet for multiple cycles in terms of fluid-structure interaction. Here, blood has been assumed as a Newtonian, incompressible fluid. Pressure profiles have been used as boundary conditions at the ventricle and the aorta. From this analysis, the motion of the leaflet has been observed with fluttering phenomenon and rebound, and the flow fields of blood have been obtained with recirculation and regurgitation. The results can contribute to the development of design methodology for the curved bileaflet mechanical heart valve.

  • PDF

Huge Hematoma in the Pelvic Cavity after Mechanical Valve Replacement - A Report of Case - (기계판막치환술 후 골반강내 대량출혈)

  • 신화균;김남혁;이용재;강창희;권오춘;이길노
    • Journal of Chest Surgery
    • /
    • v.26 no.2
    • /
    • pp.158-159
    • /
    • 1993
  • The hemorragic episode is the major problem of mechanical prosthesis, because of the necessity for anticoagulant therapy to prevent complication of thromboembolism. Double valve replacement was performed to 42 year old male due to aortic stenoinsufficiency and mitral stenosis. For anticoagulant therapy, the patient has been given wafarin under the control of prothrombin time 0.5-2 times of normal) in the our hospital. The patient was injuried the right pelvic area by waves in the beach 4 years after double valve replacement. Pelvic MRI scan showed huge hematoma in the right pelvic cavity. The patient was operated removal of intrapelvic hematoma.

  • PDF

An Experimental Study on the Impact Force of a Mechanical HeBrt Valve Prostheses (기계식 심장판막의 충격력에 관한 실험적 연구)

  • 이정한;천길정
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.215-220
    • /
    • 1996
  • Impact force and strains induced by impact between the occluder and the struts have been measured with force sensor and strain gages. The maximum reaction force was about 25N, and the calculated impact force on the root of the struts amount about 9-17W. Impact force on the inlet strut is greater than that of the outlet strut, but the strain on the outlet strut is much higher than that of the inlet strut. These values might cause severe damage on the valve in the critical cases. The results of this study may be extended for the analysis of the endurance limit and optimal design of the struts and occluder.

  • PDF

Valve Thromboses after Mechanical Valve Replacements -3 Caseds- (기계판막 치환후 발생한 혈전증 3례 보고)

  • 문준호
    • Journal of Chest Surgery
    • /
    • v.27 no.12
    • /
    • pp.1031-1035
    • /
    • 1994
  • Mechanical valve thrombosis is a serious and potential lethal complication unless early diagnosis & prompt therapy are made. We have been experienced 3 cases of valve thrombosis. From Aug. 1988 to July 1994, reoperations of mitral valve replacement [MVR] with mechanical prostheses [all mitral] were performed in three patients[2 men, 1 woman] due to valve thromboses. All three patients were diagnosed by means of cineradiography. Preoperative status of was shock status and he was applied intra-aortic balloon pump [IABP]. All three cases of prosthetic valve failure [PVF] were treated by Redo-MVR. Time intervals of reoperations were 5months, 40months, and 35months, respectively. In all cases, valve thromboses were excised successfully. Cineradiography provided an accurate diagnosis in all cases, which was utilized as safe, reliable & noninvasive imaging modalities. There were no operative death & complication. All three patients were fully recovered and returned to their employements, and active lives.

  • PDF

Clinical Experience of Carbomedics Valve (CarboMedies 기계판막의 임상적 연구)

  • 김병열
    • Journal of Chest Surgery
    • /
    • v.27 no.12
    • /
    • pp.995-1001
    • /
    • 1994
  • The CarboMedics valve prosthesis is a relatively new. low profile bileaflet prosthesis. During a 6 year period from Aug. 1988 to July 1994. 158 patients had CarboMedics prostheses implanted in the mitral [n=94], aortic [n=25], or aortic and mitral [n=39] in National Medical Center. Hospital mortality was 9.4% and the main cause of death was low output syndrome. Follow up was 96% complete, with 365.4 patient-years and a mean follow up of 30 months [ range 1 to 72 months ] . The overall actuarial 6 year survival rate was 91.61 3.47% and actuarial 6year freedom from all valve related complications was 73.9 7.67%. The linearized incidence of vavle related complications was as follows: thromboembolism 1.37%/patient-year ; valve thrombosis 0.82%/ patient-year ; anticoagulant related hemorrhage 0.85%/patient-year ; perivalvular leakage 0.55%/paitent-year: prosthetic valve endocarditis 0.82%/patient-year ; reoperation 1.37%/patient-year. There were no instances of structural failure. We conclude that the Carbomedics valve has a low rate of complications that further improves the quality of life in patients with heart valve prostheses.

  • PDF

Mid term experience with CarboMedics Medical Valve (CarboMedics 기계판막의 임상경험)

  • 김기출
    • Journal of Chest Surgery
    • /
    • v.26 no.10
    • /
    • pp.753-760
    • /
    • 1993
  • The CarboMedics valve is a bileaflet prosthesis with excellent hemodynamic characteristics, but the long term surgical experience with this valve, its durability and its biocompatibility are unknown. During a 5 year period from october 1988 to July 1993, 748 prostheses [402 mitral, 261 aortic, 58 tricuspid, 27 pulmonic] were inserted in 552 patients [mean age 40.2 years]. The operative mortality was 6.6% [37/560, 13.2% in age group below 15 years and 5.7% above 15 years]. and the main causes of death were complex congenital malformation and left ventricular failure. Follow up was totaled 1182 patient- years and mean follow up was 28.3 months/patient. No structural failure has been observed. Hemorrhage was the most frequent valve related complication[1.78% / Patient-year]. Embolism occurred at a rate of 0.93% / Patient-year. There were 5 cases of valve thrombosis [0.42% / Patient-year, two fatal]. There occurred 11 late deaths[6 valve related] and 42 valve related complications. Actuarial survival at 5 years is 97.18 0.94% and actuarial complication free survival at 5 years is 89.07 1.54%. In summary, the CarboMedics valve stands for a durable valve substitute, with low valve related complications.

  • PDF

An Experimental Study on the Impact Force of a Mechanical Heart Valve Prostheses (기계식 심장판막의 충격력에 관한 실험적 연구)

  • Lee, J.H.;Cheon, G.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.167-171
    • /
    • 1996
  • Impact force and strains induced by impact between the occluder and the struts have been measured with force senfor and strain gages. The maximum reaction force was about 25N, and the calculated impact force on the root of the struts amount about $9{\sim}17N$. Impact force on the inlet strut is greater than that of the outlet strut, but the strain on the outlet strut is much higher than that of the inlet strut. These values might cause severe damage on the valve in the critical cases. The results of this study may be extended for the analysis of the endurance limit and optimal design of the struts and occluder.

  • PDF

Clinical Analysis of Bjork-Shiley Mechanical Valve Replacement (Bjork-Shiley 기계판막의 임상적 연구)

  • 김병열
    • Journal of Chest Surgery
    • /
    • v.22 no.3
    • /
    • pp.393-401
    • /
    • 1989
  • Between Dec. 1984, and May, 1988,96 prostheses were implanted in 80 patients at Dept. of Thoracic k Cardiovascular Surgery of National Medical Center. 43 patients had mitral valve replacement, 21 underwent aortic valve replacement, and 15 had double valve replacement [Mitral k Aortic], and 1 had tricuspid valve replacement. Seventy-one cases [88.8 %] were in NYHA Class III or IV. The mean duration of follow up was 22.1 months and follow-up information was available for 74 [92.5 %] of the patients. The overall actuarial survival rate at 45 months was 93.05 % and overall hospital mortality was 10 %, late Mortality was 5 %. The linearlized incidence of thromboembolism [2.4%/pt-yr], thrombotic valve obstruction [1.6 %/pt-yr], anticoagulant related bleeding [0.8 %/pt-yr]. There were no fatal valve related complications. The blood was studied in 40 patients 1 year after valve operation. Hgb and reticulocyte count were within normal values and Serum LDH value was slightly elevated but it was not of clinical significance. In conclusion, Monostrut Bjork-Shiley valve prosthesis to be a reliable valve substitute with an acceptable incidence of complications.

  • PDF

Surgical Treatment of Complications after Fontan Operation (Fontan수술후의 합병증에 대한 수술적 치료)

  • 박정준;홍장미;김용진;이정렬;노준량
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.73-78
    • /
    • 2003
  • The Fontan operation has undergone a number of major modifications and clinical results have been improving over time. Nevertheless, during the follow-up period, life-threatening complications develop and affect the long-term outcomes. Surgical interventions for these complications are needed and are increasing. Material and Method: From April 1988 to January 2000, 16 patients underwent reoperations for complications after Fontan operation. The mean age at reoperation was 8.8 :-5.5 years. Initial Fontan operations were atriopulmonary connections in 8 and total cavopulmonary connections in 8. Total cavopulmonary connections were accomplished with intracardiac lateral tunnel in 5 and extracardiac epicardial lateral tunnel in 3. Five patients had variable sized fenestrations. The reasons for reoperations included residual shunt in 6, pulmonary venous obstruction in 3, atrial flutter in 3, atrioventricular valve regurgitation in 2, Fontan pathway stenosis in 1, and protein-losing enteropathy in 1 Result: There were 3 early and late deaths respectively Patients who had residual shunts underwent primary closure of shunt site (n=2), atrial reseptation for separation between systemic and pulmonary vein (n=2), conversion to lateral tunnel (n=1), and conversion to one and a half ventricular repair (n=1). Four patients who had stenotic lesion of pulmonary vein or Fontan pathway underwent widening of the lesion (n=3) and left pneumonectomy (n=1) In cases of atrial flutter, conversion to lateral tunnel after revision of atriopulmonary connections was performed (n=3). For the atrioventricular valve regurgitation (n=2), we performed a replacement with mechanical valve. In one patient who had developed protein-losing enteropathy, aorto-pulmonary collateral arteries were obliterated via thoracotomy. Cryoablation was performed concomitantly in 4 patients as an additional treatment modality of atrial arrhythmia. Conclusion: Complications after Fontan operation are difficult to manage and have a considerable morbidity and mortality. However, more accurate understanding of Fontan physiology and technical advancement increased the possibility of treatment for such complications as well as Fontan operation itself. Appropriate surgical treatment for these patients relieved the symptoms and improved the functional class, Although the results were not satisfactory enough in all patients.