• 제목/요약/키워드: 급수설비계통

Search Result 9, Processing Time 0.028 seconds

Development of Engineering Program for APR1400 Feedwater Supplying System (APR1400 급수공급계통 엔지니어링 프로그램 개발)

  • Yeom, Dong Un;Ju, Tae Young;Hyun, Jin Woo
    • Journal of Energy Engineering
    • /
    • v.26 no.2
    • /
    • pp.12-22
    • /
    • 2017
  • Korea Hydro & Nuclear Power Co. (KHNP) has implemented engineering programs for operating nuclear power plants. Engineering programs are maintenance rule (MR), functional importance determination (FID), single point vulnerability (SPV) and functional equipment group (FEG). Recently, KHNP has developed engineering programs for APR1400 feedwater supplying system to establish the advanced engineering system and will verify the suitability of engineering programs through implementing in new nuclear power plant. Consequently, it is expected that the reliability of APR1400 feedwater supplying system will be improved by implementing engineering programs.

Flow Characteristics of a Water Supply System with Booster Pumps for an Apartment Complex (공동주택단지에 설치된 부스터펌프 급수설비계통의 유동 특성)

  • Oh, Yang-Gyun;Jeong, Jae-Bong;Park, Mi-Ra;Cha, Dong-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.151-156
    • /
    • 2008
  • Water flow characteristics of an apartment complex consisting of 12 buildings and 635 units in total have been investigated numerically. The complex incorporates two zone booster pump water supply system, and some units have pressure reducing valves in them. Input data to a commercial code Flowmaster7 include survey results on the water usage for the last three years, dimension of the water supply system and its operation condition, etc. Calculated static pressures at the inlet of all units are compared with their design and measured counterparts, and they agree quite well with each other. Then, the pressure distributions and volumetric flow rates at all 635 units are estimated. Flow balancing is also attempted by varying the ratio of angle valve of each unit to improve the non-uniformity of flows.

  • PDF

촉매수지식 용존산소 제거설비 - 개발경위와 앞으로의 활용전망

  • 이창소
    • Nuclear industry
    • /
    • v.16 no.2 s.156
    • /
    • pp.47-55
    • /
    • 1996
  • 원자력발전소 2차 계통수중의 용존산소는 증기발생기 뿐만 아니라 터빈 급수가열기와 응축기 등 주요설비 부식의 직접적인 원인으로서, 원자력발전의 경제성 저하 및 원전설비의 안전성에 심각한 문제를 야기시키고 있다. 한국정수공업(주)는 최근 $\ulcorner$촉매수지식 용존산소 제거설비$\lrcorner$를 한국원자력연구소의 기술지원 아래 연구$\cdot$개발하여 고리원자력 1호기에 설치$\cdot$운용중에 있다. 그 개발경위와 활용전망 등을 알아본다.

  • PDF

Design of Multivariable 2-DOF PID for Electrical Power of Flow System by Neural Network Tuning Method (신경망 튜우닝에 의한 유량계통 동력 제어용 다변수 2-자유도 PID의 제어기 설계)

  • 김동화
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.78-84
    • /
    • 1998
  • The fluid system such as, the quantity control of raw water, chemicals control in the purification, the waste water system as well as in the feed water or circulation system of the power plant and the ventilation system is controlled with the valve and moter pump. The system's performance and the energy saving of the fluid systems depend on control of method and delicacy. Until, PI controller use in these system but it cannot control delicately because of the coupling in the system loop. In this paper we configure a single flow system to the multi variable system and suggest the application of 2-DOF PID controller and the tuning methods by the neural network to the electrical power of the flow control system. the 2-DOF controller follows to a setpoint has a robustness against the disturbance in the results of simulation. Keywords Title, Intelligent control, Neuro control, Flow control, 2 - DOF control., 2 - DOF control.

  • PDF

Optimal Var sizing and Allocation Considering Voltage Stability Margin (전압안정도 제약을 고려한 조상설비 최적투입계획)

  • Sung, Ung;Kim, Tae-Gyun;Lee, Byung-Jun;Song, Hwa-Chang;Kim, Tae-Gyun;Shin, Jeong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.95-96
    • /
    • 2008
  • 사회가 발전함에 따라 전력 수요는 기하급수적으로 증가한다. 늘어나는 전력 수요는 전압안정도 마진을 감소시키고 이는 대정전의 원인이 될 수도 있기 때문에 전력계통에서 전압유지 및 전압안정도 여유확보는 중요한 이슈가 된다. 무효전력은 전압과 큰 관련이 있기 때문에 전압유지 및 전압안정도 여유확보 방안으로써 가장 최우선적으로 고려되는 사항이 조상설비를 추가하는 것이다. 하지만 조상설비를 추가하기 위한 용지확보, 비용, 환경문제 등의 영향으로 인한 전원의 원격화, 편재화 그리고 부하의 수요집중화에 의한 송전설비의 장거리화와 대용량화가 진행되고 있으며 이와 같은 장거리 송전에 따라 계통손실의 증가와 수요지의 저전압문제가 발생하고 있다. 그러므로 전압안정도 마진을 고려하면서 조상설비를 적절하게 투입하는 것은 중요한 고려사항이다. 본 논문은 2007년 8월 EMS Peak 데이터를 시뮬레이션 해 조상설비를 투입함에 있어 최적의 위치와 용량을 산정하는 위한 방안을 제시한다. 이러한 조상설비 추가를 최소로 하는 경제적인 측면 뿐 아니라 전압 안정성 측면도 고려하기 위한 부하 scaling 기법을 적용해 전압안정도 여유를 확보하기 위한 방안을 추가한다. 또한 여러 가지 상정사고를 가정한 후 heuristic method를 적용해 조상설비 최적화를 수행하고 한전데이터를 근거로 추가할 조상설비의 가장 적절한 투입위치 및 용량을 산정해 제시한다.

  • PDF

A Numerical Study on the Dynamic Characteristics of Water Hammer Arresters for Building Service Applications (건축설비용 워터햄머흡수기의 동특성에 관한 수치 연구)

  • 노승환;차동진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.4
    • /
    • pp.269-277
    • /
    • 2002
  • Dynamic characteristics of water hammer arresters installed in a building water supply system have been investigated numerically by utilizing a commercial rode that employs the method of characteristics. Some preliminary results with those arresters produced in this study agree well with the previously reported. Then, the arresters have been incorporated into a water supply pipe system of a $59m^2$ apartment unit constructed by a leading construction company, and their dynamic characteristics, especially on the reduction in the water hammer pressure, are investigated. It is found that the setting of the arresters in the pipe system, which is recommended by the company, may not be proper for reducing the pressure to less than 1082.0 kPa when buick-closure valves in the pipe system are closed within 30 ms at the static pressure of 542.6 kPa. More arresters in the system may be required to meet a pressure criteria.

Analysis of Loss of HVAC for Nuclear Power Plant (원전의 공기조화설비(HVAC) 상실사고 분석방법)

  • Song, Dong-Soo
    • Journal of Energy Engineering
    • /
    • v.23 no.1
    • /
    • pp.90-94
    • /
    • 2014
  • Environmental qualification (EQ) for safety-related equipment is required to ensure that those equipment will perform their required function even under the harsh environment conditions arising from design basis accident in the nuclear power plant. As a part of EQ program, the room temperature analysis in case of a loss of Heating, Ventilation, and Air Conditioning(HVAC) system was carried out to ensure the operability of the safety-related equipment of a nuclear power plant randomly chosen among the Korean nuclear power plants. In this paper, this analysis was performed in the conservative perspective using GOTHIC code. The room temperature analysis includes selecting the rooms in which the safety related equipment are located but not supported by safety related HVAC and determining the temperature of the selected rooms. Target rooms for the analysis consist of W229/W237 (Aux. feedwater pump room), W232 (Aux. feedwater tank room) and W230 (Equipment passageway). The results showed the temperature range from $43^{\circ}C$ to $83^{\circ}C$, in 72 hours after a loss of HVAC. Those values are far below of generic EQ temperature($171^{\circ}C$). Therefore, it is satisfied with EQ requirement of temperature limits on safety related equipment.

Installation Design of Landscape-use Artificial Channel for Sustainable Management -Focusing on the Water Volume and Equipment System of Streamlet in Jeonju and Wanju Innovation City- (계류형 수경시설의 지속가능한 운영·관리를 위한 설치방안 - 전주·완주 혁신도시 실개천 용량과 설비계통을 중심으로 -)

  • Oh, Chang-Song
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.49 no.2
    • /
    • pp.113-127
    • /
    • 2021
  • Although planning techniques linking parks, green areas, and waterways have become common, there are frequent disruptions in the operation and management of landscape-use artificial channels (LuAC). Therefore, this study examined a design to promote the sustainable management and operation of a LuAC using rainwater for the streamlets of the Jeonju-Wanju Innovative City. In order to accomplish the purpose of this study, scenarios were set up by dividing the design into waterhead and waterway portions. First, the scenario regarding the waterhead was analyzed to calculate the water supply and storage required for the waterway and waterhead. The analysis showed that the waterway requires a water supply of 676.8 tons/months, 3,018 tons to 5,512 tons of storage space, and a water depth of 0.75 m to 1.37 m considering the ecological and landscape aspects. The second scenario is to select an effective system of facilities for the operation and management of the LuAC. To accomplish this, a single-circulation system (SCS), which transports water to a highland location was compared to a multi-circulation system (MCS), which supplied water separately to each water space and operated independently. The results showed that the MCS, which was operated independently by small power units, was more effective owing to the vast difference in water supply operation times.