• Title/Summary/Keyword: 급수량

Search Result 355, Processing Time 0.024 seconds

Pressure restricted water supply method during drought using a computer simulation and daily water supply analysis (시뮬레이션과 1일 급수량 분석을 이용한 갈수기 감압에 의한 제한급수 방법)

  • Nam, Youngwook;Kim, Kyungsu;Hyun, Inhwan;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.5
    • /
    • pp.335-344
    • /
    • 2020
  • Due to global climate change, mega-droughts have occurred frequently. Since long-term droughts make it difficult to secure the water resources, water supply needs to be restricted in a reasonable manner. In the event of limited water supply, the waterworks need to develop a restricted water supply strategy. This study showed that analyzing daily water supply could be used to respond to the first stage of a drought. According to an analysis of Korea's major water authorities, there was about 7~21% of room for daily minimum water supply in case of a drought. Restricting the water supply by lowering pressure is a good strategy for local water authorities with high water leakage rate since leakage is inversely dependent with pressure. For this method, it is necessary to quantify water deficiency and pressure at each node using a simulation. Since DDA-based software is not possible to predict changes in demand at nodes with pressure reduction, WaterGEMS, a PDA software, was used to quantitatively predict water shortages and pressures at each node. Locations where water is deficient need to install booster pumps or to be dispatched with water tank truck and bottled water. Without these support, lowering pressure could not be an option for water works. This paper suggests a method for waterworks to plan a drought by lowering pressure to restrict water supply using daily water supply analysis and PDA based simulation.

An Analysis on Water Supply Amount for Economic Plan in School Buildings (학교건축의 적정 급수량 산정을 위한 사용수량 분석)

  • Lee, Jae-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2924-2932
    • /
    • 2015
  • This study is for estimate the amount of water supplied data to get a database for economic plan of water supply system by survey for the amount of water supplied of primary, middle and highschool. For this, 54 of primary school, middle school, high school in 6 cities of Kangwon for 5 years. As a result, average of the amount of water supplied per month is $600.7m^3/mon$ and primary, middle schools are $484.2m^3/mon$ and high schools are $833.8m^3/mon$. Average of the amount of water supplied per class is $27.0m^3/mon/class$ and primary, middle schools are $24.4m^3/mon/class$ and high schools are $32m^3/mon/class$. Average of the amount of water supplied per person per day is 55.8l/c/d and primary school, middle schools are 54.4l/c/d and high schools are 58.6l/c/d.

Change of Water Consumption Results from Water Demand Management (수요관리에 따른 물 사용량 변화)

  • Seo, Jae-Seung;Lee, Dong-Ryul;Choi, Si-Jung;Kang, Seong-Kyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.366-366
    • /
    • 2011
  • 수자원 관리 정책은 한정된 수자원의 재배분과 효율적 이용, 수요관리에 의한 물 절약 정책 등, 지속가능한 발전을 추구하면서 물 부족의 사회적 대응력을 향상시키기 위한 정책으로 전환되어 가고 있다. 환경부에서는 2000년에 "물 절약 종합대책(2000.3)"발표를 시작으로 시 도별 "물 수요관리 종합대책"을 수립하였고, "수자원장기종합계획(2006.9)"수립에서는 수요관리 시나리오에 따른 장래수요량을 예측하여 발표하였다. 그러나 수요관리에 따른 절감량 산정 및 정량화된 수요량 평가 시스템의 부재로 수요관리 정책수립이나, 장래 용수수요량 예측에 어려움을 겪고 있다. 이에 따라 물 수요관리에 따른 물 사용량의 변화를 파악하고, 이를 이용하여 장래수요량 예측 및 물 수급전망에 연계할 수 있는 시스템이 필요하다. 본 연구에서는 지자체별 수요관리 계획 및 추진결과에 따른 물 사용량의 변화를 분석하였다. 또한 수요관리 계획과 추진전후의 상수도 관련 지표를 비교하여 합리적인 수요관리 계획 수립을 제안하였다. 분석결과 물 절약 종합대책 및 물 수요관리 종합대책 수립이후 1인1일당 급수량의 증가가 대체로 둔화되는 것을 알 수 있었다. 그렇지만 수요관리 계획을 수립한 일부 지자체는 과도한 계획수립으로 인하여 계획대비 수요관리 추진 효과가 미비한 곳도 있었다. 이러한 지자체는 현 상황을 고려한 합리적인 수요관리 계획 수립이 필요함을 알 수 있었다. 본 연구결과는 장래 용수수요량 예측이나 물수요관리 정책수립에 활용할 수 있을 것으로 판단된다.

  • PDF

Analysis of pattern of water usage using AMI data in 112 block of Youngjong island (영종도 112블록의 AMI 데이터를 이용한 물 사용 패턴 분석)

  • Koo, Kang Min;Han, Kuk Heon;Yum, Kyung Taek;Jun, Kyung Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.223-223
    • /
    • 2018
  • 취수원에서 정수장과 배수지를 거쳐 수용가에 이르기까지 공급되는 급수량을 결정하는데 있어 각 수용가별 물 사용 패턴은 수요량을 예측하여 취수량을 결정하는데 있어 매우 중요한 지표이다. 생활용수 추정은 용도별(가정용, 상업용, 공업용 등)로 분류하여 경향성이 나타날 수 있도록 과거 사용실적을 바탕으로 장래 용도별 사용량을 추정한다. 이는 경험을 바탕으로 한 것으로 일반적으로 시계열 모형을 이용하는데 수요예측의 실패 가능성이 높으며 효율적인 방법이라 할 수 없다. 이에 본 연구에서는 최근 통신기술의 발달로 양방향 통신이 가능한 AMI(Advanced Metering Infrastructure, 원격검침인프라)센서를 영종도 112블록의 528개의 수용가에 설치하였다. AMI는 스마트 미터에서 측정한 데이터를 원격 검침기를 통해 물 사용량을 자동으로 계측할 수 있다. AMI 데이터를 이용하여 영종도 112블록의 운북동과 운서동의 각 용도별, 요일별, 그리고 도심지와 농가의 실시간 물 사용 패턴을 분석하였다. 분석 결과 운북동과 운서동의 물 사용 패턴은 비슷한 경향을 보이는 것으로 보이나 도시화된 운서동에 비해 운북동의 물사용량이 상대적으로 적고 첨두사용량의 발생시간 또한 빠른 것으로 나타났다. 또한 가정용과 공공용의 경우 시간별 물 사용량이 요일에 따라 일정한 경향이 있으나 상업용과 공업용은 일정한 사용량을 보였다. 향후 112블록의 관망해석에 실시간 물사용 패턴을 적용하여 효율적으로 급수량 결정을 할 수 있을 것으로 사료된다.

  • PDF

Application of Generalized Transmissivity Decreasing Function in TOPMODEL Operation (TOPMODEL 투수량계수 감소함수 일반화과정의 적용에 관한 연구)

  • Jeong, Seon-Hui;Kim, Sang-Hyeon
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.6
    • /
    • pp.637-647
    • /
    • 1999
  • This study investigated the applicability of generalized TOPMODEL approach which introduces the power law of decreasing transimissivity with depth instead of the traditional exponential decreasing function. The 50m digital elevation model(DEM) of Dongkog subwatershed at Wichon Test Watershed was used to perform runoff simulation. Random number generation algorithm was integrated into the calibration process for the reliable of model performance. General power law version of TOPMODEL with exponent 2 and 3 showed higher simulation efficiency than other the approaches. This results from the fact that the power law models with exponent 2 and 3 can represent the soil characteristics of study area better than other models.

  • PDF

해안유역의 지하수 함양율 평가기법

  • 박남식;한수영
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.02a
    • /
    • pp.199-221
    • /
    • 2004
  • 본 연구의 목적은 해안 유역의 지하수 함양율을 평가하는 기법을 제시하는 데 그 목적이 있다. 해안 유역에서 이용되는 수자원 중에서 지하수가 차지하는 비중은 내륙에 소재한 유역의 지하수 비중에 비하여 더욱 크다. 해안지역의 급수율은 전국 평균 급수율의 절반에도 미치지 못하는 40%대로 나타났으며, 해안지역 1인당 지하수 이용량은 전국 평균의 4배에 달하는 261㎥로 조사되었다(홍성훈 외, 2003). 또한 94년과 96년에 발생한 10∼15년 재현기간의 가뭄 시대부분의 해안지역이 제한급수지역에 포함된 바 있다(건설교통부, 2001). (중략)

  • PDF

Estimating water demand in apartment buildings for the economic design of water supply system (아파트 급수설비의 적정설계를 위한 급수량 산정)

  • 김성식;김지현
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.27 no.5
    • /
    • pp.444-455
    • /
    • 1998
  • 1960년 이후 급속한 경제성장과 산업화에 따라 도시의 인구 집중과 핵가족화 현상으로 주택에 대한 수요가 증가하자 공동주택을 짧은 기간에 대량으로 공급하지 않을 수 없게 되었다. 이 결과 1995년 국내 통계에 의하면 도시주택 유형 중 아파트가 48.1%를 차지할 만큼 대표적인 공동주거 형태로 자리잡게 되었으며 가용택지의 부족은 이후로도 단독주택보다 아파트와 같은 공동주택 건설의 중대를 야기할 것으로 예상된다.

  • PDF

Water Quality Modelling of the Keum River - Effect of Yongdam Dam (용담댐의 영향분석을 위한 금강의 수질모델링)

  • Lee, Eun-Hyung;Seo, Dong-Il
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.5
    • /
    • pp.525-539
    • /
    • 2002
  • Effects of Yongdam Dam discharge conditions on water quality of the Keum River and Daechung Lake inflow were analyzed for various scenarios using WASP5 water quality model. Three different groups of scenarios were tested: 1) Two different weather conditions; the lowest flow year and the highest flow year since the beginning of Daechung Dam operation in 1981, 2) Fine discharge flow rates; 5.4, 8.9, 12.4, 16.4 ㎥/s and field observed flow during the study period, 3) Three conditions of discharge water quality; first grade, second grade by Korean water quality standard and field observed water quality. Effect of changes in Yongdam Dam discharges was greater for dry year. The increase of discharge from the Yongdam Dam will improve water quality of downstream areas only when the water quality of the discharge is equal or better than that of downstream areas. Field observed water qualify data show that BOD concentrations are lower than first grade level but TN and TP concentrations are exceeding 5th and 3rd grade level in Korean standard, respectively. Considering that nutrient control methods in watershed areas of Yongdam dam are limited, it is expected that nutrient concentrations from Yongdam Dam discharge will be higher than 2nd grade water quality standard level. Therefore, it would be important to develop practical management strategies in the watershed area of Yongdam Dam based on field conditions for conservation of water quality in downstream areas.

월성 2,3,4호기 비상급수계통 성능평가에 관한 연구

  • 오광석;김창호;이중섭;김선철;오종필
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.362-367
    • /
    • 1996
  • CANDU-6형 원자력발전소인 월성 2,3,4호기 비상급수계통의 성능을 평가하기 위하여 설계기능 수행과 관련된 변수로서 격납건물내 집수조(sump) 온도와 열수송계통으로 주입되는 냉각재온도를 사용한 분석을 수행하였다. 이 온도들은 NTU(Number of Transfer Unit)방법을 이용한 비상노심 냉각계통 열교환기의 열전달속도와 열전달계수의 해석을 열평형관계식과 함께 조합한 프로그램을 사용하여 계산하였다. 또한 증기발생기 급수량과 추후 수조에 공급되는 보충수에 대한 설계요건을 검토하였다. 이러한 변수와 설계요건은 비상급수계통이 발전소 정상 열제거기능 상실후 노심의 붕괴열제거에 유효한 열침원으로서의 기능을 수행함을 보여 주었다. 또 격납건물의 건전성 유지와 관련된 집수조내 최고온도가 허용치 이하로 유지되었다.

  • PDF

초고층아파트 최적 설비시스템 개발 -급수설비시스템 개발을 중심으로-

  • 이대원;김태형;최도혁;김종필
    • 월간 기계설비
    • /
    • s.35
    • /
    • pp.84-96
    • /
    • 1993
  • 본 연구는 '초고층 아파트 최적 설비시스템 개발'의 제2차년도 연구로서 아직까지 국내에서 확립되어 있지 않은 초고층 아파트 급수설비 시스템 및 수격방지 시스템의 모델정립과 연돌효과에 의한 열손실 추정 및 적정 설계 지침 설정에 관한 연구를 수행하였다. 이를 위하여 이론 해석 및 현장실험을 수행하였고, 결과분석을 통하여 최적화 설계방안도 아울러 도출하였다. 급수설비 분야에서는 각종 급수 시스템의 해석 및 비교를 통한 효율적인 시스템의 설계 및 선정방법을 제시 하였고, 실제 초고층 아파트에 대한 수격현상 해석 및 실험을 통하여 수격작용의 영향을 감소시킬 수 있는 설계방안을 검토하였다. 또 입주중인 초고층 아파트 현장에서의 실측을 통하여 건물의 높이에 따라 불균일한 틈새가 있는 일반적인 경우에 대한 모델을 정립하였고, 수치해석을 통한 수직통로 내의 실제 열유동 현상을 정량화하고 설계지침을 제시하였다. 결과로서 각종 급수시스템의 해석을 위한 프로그램을 개발하였고, 수격의 발생을 억제하기 위한 최적 밸브 폐쇄형태를 제시하였으며, 초고층 건물의 내외부에 형성되는 압력차와 유인풍량 및 열손실량 사이의 관계식을 얻었다.

  • PDF