• Title/Summary/Keyword: 급배기

Search Result 109, Processing Time 0.029 seconds

Study on the optimal design of floor exhaust system using computational fluid dynamics for subway platform (수치해석을 활용한 승강장 바닥배기 시스템 최적화 연구)

  • Namgung, Hyeong-Gyu;Park, Sechan;Kim, Minhae;Kim, Soo-Yeon;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.443-449
    • /
    • 2017
  • The imbalance of air supply and the exhaust on subway platforms has led to the installation of platform screen doors in underground subway stations. This imbalance causes the accumulation of pollutants on the platform and loss of comfort due to the lack of ventilation. In this study, a floor exhaust system was optimized using computational fluid dynamics (CFD) and an optimization program. The optimized floor exhaust system was manufactured and tested experimentally to evaluate the particle collection efficiency. CFX 17.0 and HEEDS were used to analyze the flow field and optimize the principal dimensions of the exhaust system. As a result of the three-step optimization, the optimized floor exhaust system had a total height of 1.78 m, pressure drop of 430 Pa, and particle collection capability of 61%. A fine dust particle collection experiment was conducted using a floor exhaust system that was manufactured at full scale based on the optimized design. The experiment indicated about 65% particle collection efficiency. Therefore, the optimized design can be applied to subway platforms to draw in exhaust air and remove particulate matter at the same time.

Experimental Study for the Capacity of Ordinary and Emergency Ventilation System in Deeply Underground Subway Station (대심도 지하역사 승강장 및 대합실 평상시/비상시 급·배기 풍량에 대한 실험적 연구)

  • Jang, Yong-Jun;Lee, Ho-Seok;Park, Duck-Shin
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.579-587
    • /
    • 2012
  • Shin-gumho station in Seoul underground subway have been selected to be experimentally investigated and analyzed for the real air supply & exhaust capacity compared to the original capacity of ordinary and emergency condition. The depth of Shin-gumho station is 43.6m which consists of the island-type platform ($8^{th}$ floor in underground) and a two-story lobby (first & second floor in underground). An emergency staircase connects between the platform and the lobby. Hot-wire anemometer, capture hood, wind vane & velocity meter and data acquisition systems are employed to perform the automatic measurement in this experiment. For ordinary case, air supply and exhaust capacity in the lobby were reduced by 34% and 46% compared to the original capacity, respectively. Air supply and exhaust capacity in the platform were reduced by 66% and 38%, respectively. For emergency case, air supply in the lobby was reduced by 42% and air exhaust in the platform was reduced by 28% compared to the original capacity. Therefore, air pollution in the station is expected to be worse in the ordinary environment and smoke control capability in the platform will be weakened in case of fire emergency.

A Study on the Indoor Airflow Pattern by Changing the Location of Mechanical Terminal Unit (실내 급.배기구 위치변화에 따른 실 공기유동에 관한 연구)

  • Choi, Jeong-Min;Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.193-200
    • /
    • 2009
  • The ventilation system of apartments can be divided by supply and exhaust fan, supply fan and exhaust free and supply free and exhaust fan. Recently, the individual ventilation system and central ventilation system which is combined cooling system with duct system are applied to apartment ventilation system. The airflow pattern is affected by location of supply unit and exhaust unit in indoor. This study is to investigate the proper distance between supply unit and exhaust unit using CFD. As a result of this study, the proper distance between supply unit and exhaust unit could be suggested at the interval of 3 m in supply and exhaust fan system and 2.5 m in supply fan and exhaust free.

Numerical Study on the Effect of Area Changes in Air Inlets and Vent Ports on the Ventilation of Leaking Hydrogen (급·배기구 면적 변화가 누출 수소 환기에 미치는 영향에 관한 수치해석적 연구)

  • Lee, Chang-Yong;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.2
    • /
    • pp.385-393
    • /
    • 2022
  • Hydrogen has reduced greenhouse gas (GHG) emissions, the main cause of global warming, and is emerging as an eco-friendly energy source for ships. Hydrogen is a substance with a lower flammability limit (LFL) of 4 to 75% and a high risk of explosion. To be used for ships, it must be sufficiently safe against leaks. In this study, we analyzed the effect of changes in the area of the air inlet / vent port on the ventilation performance when hydrogen leaks occur in the hydrogen tank storage room. The area of the air inlet / vent port is 1A = 740 mm × 740 mm, and the size and position can be easily changed on the surface of the storage chamber. Using ANSYS CFX ver 18.1, which is a CFD commercial software, the area of the air inlet / vent port was changed to 1A, 2A, 3A, and 5A, and the hydrogen mole fraction in the storage chamber when the area changed was analyzed. Consequently, the increase in the area of the air inlet port further reduced the concentration of the leaked hydrogen as compared with that of the vent port, and improved the ventilation performance of at least 2A or more from the single air inlet port. As the area of the air inlet port increased, hydrogen was uniformly stratified at the upper part of the storage chamber, but was out of the LFL range. However, simply increasing the area of the vent port inadequately affected the ventilation performance.

Evaluation of Ventilation Performances for Various Combinations of Inlets and Outlets in a Residential Unit through CO2 Tracer-Gas Concentration Decay Method (CO2 추적가스 농도감소법을 이용한 공동주택의 급·배기구 조합에 따른 환기 성능 분석)

  • Sang Yoon Lee;Soo Man Lee;Jong Yeob Kim;Gil Tae Kim;Byung Chang Kwag
    • Land and Housing Review
    • /
    • v.14 no.4
    • /
    • pp.111-120
    • /
    • 2023
  • Indoor air quality has become increasingly important with the increase in time spent in residential environments, impact of external fine dust, yellow dust, and the post-COVID 19 pandemic. Residential mechanical ventilation plays a key role in addressing indoor air quality. The legal standard for residential air changes per hour in Korea is 0.5 ACH. However, there are no standards for the location of supply and return vents. This study atempts to analyze the impact of ventilation performance based on the location of supply and return vents. An experiment was conducted using the CO2 tracer gas concentration decay method in a mock-up house set inside a large chamber to minimize external influences. The experimental results indicated that the commonly used combination of 2 supply and 2 return vents in living room spaces had a lower mean age of air than the combination of 1 supply and 2 return vents. Using multiple supply and return vents had lower mean age of air than using just 1 supply and 1 return vent.

크라이오펌프 성능평가 장치 운전특성

  • In, Sang-Ryeol;Jeong, Seung-Ho;Hwang, Pil-Seo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.364-364
    • /
    • 2011
  • 국내에서 크라이오펌프 개발이 한창 진행되고 있다. 냉동기는 GM 타입이 아니고, 맥동관 형식을 채택하여 기존 상용제품과 차별화 하고 있다. 목표성능은 질소기준 배기속도가 3,600 L/s이고 다른 성능들은 기존의 상용 펌프와 유사하며 내부 구조에 상관없이 외형적으로 비슷한 제원을 가지도록 개발되고 있다. 시제품의 성능을 국제규격에 맞추어서 평가하기 위해 성능평가 장치를 구성하고 시운전 중에 있다. 평가장치는 double dome과 single dome을 모두 갖추었으며 주 배기펌프는 측정 대상 크라이오펌프가 맡고, 보조 배기펌프는 양 시스템 모두 소형 TMP를 사용하고 있다. 크라이오 펌프를 10-10 mbar 대에서부터 성능을 측정하기 위해 평가장치는 10-11 mbar 대에서 운전하도록 목표가 살정되었다. 거의 크라이오 펌프만으로 이런 목표를 달성하기 위해 어던 과정을 거쳤는지 소개하고 이 장치를 사용하여 1,500 L/s 급, 8인치 상용 크라이오 펌프를 달아 배기속도를 측정한 결과와 제시된 값을 비교했다.

  • PDF

소형(600l/min 급) 공랭식 건식진공펌프 기술 개발 연구

  • Yu, Jae-Gyeong;Gang, Min-Jeong;Gang, Sang-Baek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.221-221
    • /
    • 2012
  • 최근 진공 산업은 반도체 산업의 급속한 발전과 더불어 진공 산업이 핵심기술로 부각되고 있으며, 진공 산업의 발전이 고부가가치를 창출하는 산업으로 발전하고 있는 추세이다. 이에 (유)우성진공 기술연구소에서는 국내에서 개발이 전무한 소형급 600l/min. 급의 배기속도를 가지는 공랭식 건식진공펌프 개발과 더불어 중소기업 혁신기술 개발사업의 성공적인 수행으로 인해 상용화 단계에 있다. 본 연구에서는 소형(600l/min. 급) 공랭식 건식진공펌프에 개발 과정 및 성능에 대해 소개하고자 한다. 우선, 여타 건식진공펌프와는 달리 냉각방식이 수냉식이 아니라 공랭식 이라는 점에서 에너지 절감 및 설치 공간 제약이 없으며, 유지 비용을 절감할 수 있는 장점을 가지며, 국내에서는 소형급의 건식진공펌프가 없는 관계로 시장성을 높게 평가하고 있다. 소형급 공랭식 건신진공펌프의 냉각효율을 고려하여 하우징을 알루미늄 합금으로 제작을 하였으며, 냉각핀을 적절하게 배치하여 압축열을 효과적으로 방출하기 위한 구조가 될 수 있도록 설계하였고, 냉각팬에 의한 공랭효과를 극대화하기 위해 펌프 스킨을 사용하여 공기 유로를 형성토록 하였다. 또한, 루츠의 형상 및 각 단의 압축효율을 고려한 최적의 로터를 설계하기 위해 Involute Curve를 이용한 3-Lobe형 로터를 설계하였으며, 로터와 로터간의 Clearance를 유지 할 수 있도록 설계하였다. 향후 최적화된 로터 설계기술과 이형재질(알루미늄과 주철)간 열팽창이 고려된 적절한 clearance 유지기술을 적용하여 안정적인 배기속도 600l/min.와 도달진공도 0.005 torr를 가지는 소형 공랭식 건식드라이펌프를 상용화 하고자 한다. 또한 성공적인 과제 종료 및 기술 개발에 따라 건식진공펌프 시장에 신기술 개발 확산에 따른 기업들 간의 기술 경쟁력 촉진을 통한 국가 기술력 향상을 기대해 볼 수 있다.

  • PDF

Water Hammer Impact of Diversion Tunnel with Operation Gate using the Numerical Model and Mathmatical Analysis (수치모형과 수리분석을 활용한 도수터널 운영에 따른 수충격 영향 검토)

  • Jang, Suk-Hwan;Oh, Kyoung-Doo;Oh, Ji Hwan;Jo, Jun Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.323-323
    • /
    • 2017
  • 본 연구 대상인 주암댐-주암조절지댐간 도수터널은 저수지 간 연계운영을 통하여 서 남해안 일대의 용수 공급하기 위하여 건설되어 운영되었으나, 터널의 구조적 불안정성이 제기됨에 따라 향후 발생 가능성이 있는 용수공급 중단을 방지하기 위하여 신규 도수터널이 제안되었다. 계획된 신규 도수 터널의 주요 시설물은 크게 양방향 운영이 가능한 터널(D=3.3 m, L=11.23 km), 각 저수지 상황별 운영을 위한 취수문비 2개소, 도수가 이루어지는 상황에서 수문 돌발 폐쇄시 수충격을 감쇄하기 위한 배기구(air vents) 2개소가 계획되었다. 이에 따라 본 연구에서는 주암댐에서 주암조절지댐으로 최대 유량이 통수되는 상태에서, 수문폐쇄에 따른 수충격을 정량적으로 분석하고자 Joukowsky 공식에 적용하여 완폐쇄와 급폐쇄시 도수터널의 안정성을 검토하였으며, 수문 폐쇄로 인한 천이적인 흐름상태 등 수충격 모의가 가능한 1차원 ITM 모형을 적용하여, 수리분석과 수치모형과 결과 비교하고, 계획된 배기구의 유무에 따른 효과를 알아보고자 하였다. 분석 결과, 계획된 0.3 m/min으로 수문을 폐쇄할 경우, 도수터널의 안정성에는 문제가 없을 것으로 분석되었으나, 수문을 급 폐쇄 할 경우, 압력수두가 크게 증가하여 도수터널에 위험이 있을 것으로 분석되었으며 배기구 유무에 따른 수충격 검토 결과 도수터널 내의 수압상승을 적절히 조절하는 조압수조의 역할을 만족스럽게 수행할 것으로 분석되었다.

  • PDF