• Title/Summary/Keyword: 금속 치환물

Search Result 80, Processing Time 0.029 seconds

Metallic Radial Head Prosthesis in Korea (요골두 금속 치환물의 국내 사용)

  • Han, Sang-Hwan;Moon, Jun-Gyu;Park, Jong-Wong;Jang, Ki-Mo
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.84-91
    • /
    • 2007
  • Purpose: The aim of this study was to report seven cases of metallic radial head prosthesis and present the limit of use in Korea. Materials and Methods: Metallic radial head arthroplasty was performed on 7 patients between April 2006 and December 2006, who had complex elbow injury including comminuted radial head fracture. Indication, operative findings and outcome were assessed. Availability and payment of implant were investigated. Results: All of the patients had more than one associated injury including coronoid fracture, olecranoan fracture, and ligament ruptures. According to Mason classification, there were three type III and four type IV fractures. All radial head fractures were too comminuted to reconstruct. There were two excellent results, four good, and one poor, as graded by Mayo score. There were no patient with instability and implant related complications. Insufficient supply of implant did not enable to do scheduled surgery in 2 cases. Current medical insurance did not cover charge for radial prosthesis, five patients could not help paying for that by themselves. Conclusion: Metallic radial head implants are useful when the radial head cannot be repaired reliably. Preoperative preparing and coverage by medical insurance based on appropriate indication are helpful for decision for a treatment option.

Cementation of Tin by Aluminium from Hydrochloric acid Solution (염산산성(鹽酸酸性) 용액(溶液)중에서 알루미늄에 의한 주석(朱錫)의 치환반응(置換反應))

  • Ahn, Jae-Woo;So, Sun-Seob
    • Resources Recycling
    • /
    • v.17 no.2
    • /
    • pp.70-75
    • /
    • 2008
  • A study on the cementation for the recovery of tin with aluminium in the hydrochloric acid solution was carried out. Parameters, such as aluminium metal equivalent, pH, reaction time, reaction temperature and the concentration of chloride ions were investigated. The experimental results showed that the cementation rate of Sn(II) ions increased with increase of the addition amount of aluminium powders, temperature, pH and the concentration of chloride ions in hydrochloric acid solution. From the results, the optinum conditions for recovery of metallic tin by cementation with aluminium metal powders were proposed.

Catalytic Combustion of Benzene over Metal Ion-Substituted Y-Type Zeolites (금속이온이 치환된 Y형 제올라이트에서 벤젠의 촉매연소반응)

  • Hong, Seong-Soo
    • Clean Technology
    • /
    • v.22 no.3
    • /
    • pp.161-167
    • /
    • 2016
  • Catalytic combustion of benzene over various metal cation-exchanged zeolites has been investigated. Y(4.8)-type zeolite showed the highest activity among the used zeolites and Cu/Y(4.8) catalyst also showed the highest activity among metal cation/ Y(4.8) zeolites. The catalytic activity increased according to the amount of adsorbed oxygen acquired from O2 TPD results. The catalytic activity also increased with an increase of Cu cation concentration on Cu/Y(4.8) catalysts. The conversion of benzene on the combustion reaction depended on not benzene concentration but the oxygen concentration. In addition, the introduction of water into reactants decreased the catalytic activity.

Salt Effect of Metal Ion Substituted Membranes for Water-Alcohol Systems Using Pervaporation Processes (투과증발공정을 이용한 물-알코올계에 대한 금속이온이 치환된 이온교환막의 염효과 연구)

  • 임지원;전지현
    • Membrane Journal
    • /
    • v.11 no.3
    • /
    • pp.133-139
    • /
    • 2001
  • The hydorgen ions in PVA/SSA membranes were substituted with monovalent metal ions, $Li^{+}$, $Na^{+}$, $K^{+}$, divalent metal ion forms, $Mg^{2+}$, $Ca^{2+}$, $Ba^{2+}$, trivalent metal ion forms, $Al^{+}$. The effect of exchange with metal ions was investigated through the swelling measurement and pervaporative experiments for water-ethanol and water-methanol mixtures at various operating conditions. In addition, ESCA analysis was carried out to study the substitution of the metal ions in membranes. The swelling ratio decerased in the sequence of $Li^{+}$, $Na^{+}$, $K^{+}$ and this might be due to the 'salting-out` effect while the swelling ratios for divalnet and trivalent ion-substituted membranes were affected by the combined effect of salting-out, electrostatic crosslinking and extent of metal ion substitution. For the pervaporation performance, PVA/SSA-$H^{+}$membrane showed the lowest flux and highest separation factor for all aqueous ethanol solutions. The typical results of the flux, 59 g/$m^{2}$hr and the separation factor, 44 were obtained at $50^{\circ}C$ for 90% ethanol aqueous mixture. For water-methanol solutions, the PVA/SSA membranes substituted with monovalent PVA/SSA membranes substituted with divalent and tribalent metal ions, both `salting-out` and electrostatic effects affected the pervaporative results.

  • PDF

The Charge/Discharge for Metal Oxides Substitution and Doping of $Li_4Ti_5O_{12}$ ($Li_4Ti_5O_{12}$에서 금속 산화물 치환에 따른 충방전 효과)

  • Kang, Mi-Ra;Jee, Mi-Jung;Bae, Hyeon;Choi, Byung-Hyun;Kim, Sei-Ki;Lee, Mi-Jea
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.44-45
    • /
    • 2006
  • 초고용량 캐패시터(Supercapacitor)는 이차전지와 더불어 차세대 전지로 분류되는 신형에너지 장치로서 충 방전 속도가 다르고 순간 전력공급이 가능하며 충 방전 수명이 반영구적으로 길고 고출력을 내기 때문에 이차전지가 갖지 못하는 영역에서 동력에너지원으로 사용된다. 본 연구에서는 초고용랑 캐패시터의 전극소재인 탄소계 재료를 대신하여 비탄소계 전극소재인 $Li_4Ti_5O_{12}$의 고상법 제조를 위한 Li/Ti의 최적 조성과 혼합 방법으로 Li-Ti 계에 $Fe_2O_3$, NiO, $Nb_2O_5$, $Sb_2O_3$ 그리고 ZnO와 같은 금속산화물로 치환시켜 합성된 Li -Ti계 금속산화물의 특성 및 충 방전 효과에 미치는 영향을 관찰하고자 하였다.

  • PDF

Chemical Solution Deposition 방법으로 증착된 $Bi_{0.8}A_{0.2}FeO_3$ (A=Pb, Co) 박막의 자기적 특성에 대한 연구

  • Cha, Jeong-Ok;An, Jeong-Seon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.245-245
    • /
    • 2011
  • $BiFeO_3$ (BFO)박막에 전위금속 Pb와 Co를 각각 치환환 박막을 chemical solution deposition 방법으로 Pt/Ti/SiO2/Si(100) 기판위에 증착하였다. Bi 자리에 Pb와 Co를 20 at.% 치환하였으며, 치환된 $Bi_{0.8}Pb_{0.2}FeO_3$ (BPFO), $Bi_{0.8}Co_{0.2}FeO_3$ (BCFO) 박막의 구조적, 자기적 특성 변화를 BFO 박막과 비교하여 조사하였다. XRD 패턴을 분석한 결과 BPFO, BCFO 박막들은 모두 rhombohedrally distorted perovskite 구조였으며 불순물인 pyrochlore 상이 약하게 관측되었다. 치환이 이루어진 BPFO, BCFO 박막들의 자기 이력곡선은 안정된 포화곡선을 나타냈으며 BFO의 포화값(5 emu/$cm^3$)에 비해 크게 증가된 55 emu/$cm^3$, 35 emu/$cm^3$의 값을 나타냈다. 또한 보자력장(coercive field, Hc)값도 BFO의 500 Oe보다 크게 증가된 1,200 Oe, 800 Oe의 값을 보였다.

  • PDF

Comparison of Metal Artifact Reduction Algorithms in Patients with Hip Prostheses: Virtual Monoenergetic Images vs. Orthopedic Metal Artifact Reduction (고관절 인공치환술 환자에서 금속 인공물 감소 방법의 비교: 가상 단일에너지영상 대 금속 인공물 감소기법)

  • Hye Jin Yoo;Sung Hwan Hong;Ja-Young Choi;Hee Dong Chae
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1286-1297
    • /
    • 2022
  • Purpose To assess the usefulness of various metal artifact reduction (MAR) methods in patients with hip prostheses. Materials and Methods This retrospective study included 47 consecutive patients who underwent hip arthroplasty and dual-energy CT. Conventional polyenergetic image (CI), orthopedic-MAR (OMAR), and virtual monoenergetic image (VMI, 50-200 keV) were tested for MAR. Quantitative analysis was performed in seven regions around the prostheses. Qualitative assessments included evaluation of the degree of artifacts and the presence of secondary artifacts. Results The lowest amount of image noise was observed in the O-MAR, followed by the VMI. O-MAR also showed the lowest artifact index, followed by high-keV VMI in the range of 120-200 keV (soft tissue) or 200 keV (bone). O-MAR had the highest contrast-to-noise ratio (CNR) in regions with severe hypodense artifacts, while VMI had the highest CNR in other regions, including the periprosthetic bone. On assessment of the CI of pelvic soft tissues, VMI showed a higher structural similarity than O-MAR. Upon qualitative analysis, metal artifacts were significantly reduced in O-MAR, followed by that in VMI, while secondary artifacts were the most frequently found in the O-MAR (p < 0.001). Conclusion O-MAR is the best technique for severe MAR, but it can generate secondary artifacts. VMI at high keV can be advantageous for evaluating periprosthetic bone.

A Study on CO Substitution of Group 6 Metal Carbonyls by Using Phase Transfer Catalyst(2) (상이동촉매에 의한 GROUP 6 금속카르보닐의 CO 치환에 관한 연구(2) : 반응시간과 촉매량에 의한 영향)

  • Yang, Hyun-Soo;Park, Ha-Seon
    • Applied Chemistry for Engineering
    • /
    • v.3 no.3
    • /
    • pp.407-411
    • /
    • 1992
  • The effects of phase transfer catalyst was studied on the substitution of CO ligand of $Mo(CO)_6$ [M=Cr, Mo, W] with two electron-pairs donating ligands, 2, 2'-bipyridine and 2, 2'-biquinoline. The change of product yield, $M(CO)_4(L)_2$, was discussed according to reaction time, mole composition of $M(CO)_6$, and type of ligand.

  • PDF