• Title/Summary/Keyword: 금속이물

Search Result 110, Processing Time 0.024 seconds

The Effect on Breakdown of the Conducting Particles Between Coaxial Cylindrical Electrodes in $SF_6$ Gas ($SF_6$ 가스 동축원통전극 내의 금속이물이 절연파괴에 미치는 영향)

  • 조국희;권동진;이강수;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.85-90
    • /
    • 1998
  • This paper describes the breakdown characteristics of GIS by the free conducting particles under alternating voltage. If the conducting particles are present within the GIS, they can cause decrease in breakdown voltages. Various materials and sizes of free conducting particles were used to study the liftoff electric field and breakdown voltage. The measured lift-off electric fields were compared with the calculated ones for copper, steel and aluminium wire-type conducting particles. As an experimental result, it is shown that the breakdown voltages of the GIS chamber with conducting particles were lower than those without conducting particles, and were markedly dependent on the particle material and the particle sizes. Free conducting particles are important factor in particle-triggered breakdown of the GIS.he GIS.

  • PDF

Motion Characteristics of Particle in Model GIS (모의 GIS내 금속이물의 거동특성)

  • 김경화;이재걸;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.152-159
    • /
    • 1999
  • This paper describes the rmtion characteristics of a particle in GIS under AC voltage. To measure the motion characteristics of the particle, a model gas chamber and parallel plain electrodes were designed and manufactured lift-off voltages of wire and spherical particles on the electrode were calculated and rreasured, and electric charge was calculated. By using a high speed carrera, the rmtion characteristics of various particles with aw}ied voltages, such as motion pattern, lift-off time, lift-off height, were analyzed 1be lift-off voltages were greatly affected by diarreters of wire and spherical particles. At voltage around lift-off voltage, the stand-up particle in vertical state rmved up and down between electrodes and the height of the lift-off particle was low. At voltage around breakdown voltage, the particle repeated vertical rotation a few times while they were being lifted off, and then, they were floating between the electrodes.trodes.

  • PDF

The partial discharge and breakdown phenomena due to metallic particle in $SF_6$ gas chamber ($SF_6$ 가스챔버내 금속이물에 대한 부분방전 및 절연파괴 현상)

  • 이재걸;곽희로;조국희;박중신
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.75-81
    • /
    • 2000
  • This paper describes the partial discharge due to particles in $SF_6$ gas. A model GIS chamber was designed and manufactured. The partial discharge and breakdown phenomena due to the particles between electrodes were observed and partial discharge signals were detected, using an ultrasonic sensor. The analysis of the electric field by the states of the particle inserted between the electrodes, were also carried out. The partial discharge was observed at end while the particle was moving in $SF_6$ gas. The partial discharge in micro-gap grows to arc, and after all, it can cause a breakdown.The electric field strength was the highest in case that the particle was vertically attached on the conductor, and the lowest in case that it was horizontally attached on the enclosure.

  • PDF

X-ray Image Correction Model for Enhanced Foreign Body Detection in Metals (금속 내부의 이물질 검출 향상을 위한 X-ray 영상 보정 모델)

  • Kim, Won
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.10
    • /
    • pp.15-21
    • /
    • 2019
  • X-rays with shorter wavelengths than ultraviolet light have very good penetration power. It is convergence in industrial and medical fields has been used a lot. n particular, in the industrial field, various researches have been conducted on the detection of foregin body inside metal that can occur in the production process of products such as metal using x-ray, a non-destructive inspection device. Detectors are becoming increasingly popular for the popularization of DR (Digital Radiography) photography methods that digitally acquire X-ray video images. However, there are cases where foreign body detection is impossible depending on the sensor noise and sensitivity inside the detector. When producing a metal product, since the defective rate of the produced product may increase due to contamination of the foreign body, accurate detection is necessary. In this paper, we provide a correction model for X-ray images acquired in order to improve the efficiency of defect detection such as foreign body inside metal. When applied to defect detection in the production process of metal products through the proposed model, it is expected that the detection of product defects can be processed accurately and quickly.

Arthroscopic Retrieval Analysis for Intra-articular Foreign Body of the Knee Joint (슬관절내 이물질에 대한 관절경적 제거술식의 분석)

  • Lee, Byung-Ill;Choi, Hyung-Suk;Jo, Joo-Hyoung;Kwon, Sai-Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.211-216
    • /
    • 2008
  • Purpose: The frequency of foreign body in the knee joint is not as high, but it sometimes required wide or multiple arthrotomy in order to remove, which can baffle the surgeon in some ways. Our study is to evaluate for effectiveness of arthroscopic retrieval for intra-articular foreign body in the knee joint. Materials and Methods: The 22 patients(16 males, 6 females) had received arthroscopic foreign body retrieval in the knee joint from March 1983 to September 2006. The causes of foreign bodies of the knee joint were 7 of trauma (31.9%) related cases, 13 of surgery related cases (59.0%), 2 found during follow up after operation (8.1%) in pathologies of foreign body. Results: There were 15 of metal showed the most percentage (68.1%), 7 of non-metal (31.9%) in types of foreign bodies, and others included bullet, suture material, pencil lead, broken wire etc. All cases were used by arthroscopic techniques. All foreign bodies were removed easily and were showed no complication such as postoperative joint stiffness. Conclusion: Arthroscopic foreign body retrieval in the knee joint is effective surgery in terms of easy access to foreign body and less postoperative complication.

  • PDF

소규모 업소용 HACCP 표준 관리 기준

  • 식품의약품안전청
    • Food Industry
    • /
    • s.218
    • /
    • pp.24-49
    • /
    • 2010
  • ${\bigcirc}$ 본 업소는 어묵류(튀김어묵, 찐어묵, 구운어묵)을 생산하는 식품제조 가공업소로서 총 5명의 인원이 어묵류 15개 제품을 생산하여 매출액은(약 00원)이며 주도 대형 유통판매업소에 판매하고 있다. ${\bigcirc}$ 본 업소의 어묵은 연육, 농산물 등과 식품첨가물을 배합 성형 후 가열 등의 공정을 거쳐 생산된 제품으로, 원료 취급과정에서의 오염이나 불충분한 가열, 교차오염 등으로 식중독균(병원성대장균, 황색포도상구균 등)과 원료 및 제조과정에서 이물(금속 등)이 혼입될 수 있으며, ${\bigcirc}$ 이로 인한 주요클레임 발생사례는 최근 3년간 관계당국으로부터 대장균군 검출 3건, 소비자클레임 2건이 있었다. - 연도별 주요 클레임내용은 '08년도에는 대장균군 검출 3건, '09년도 튀김어묵에서 날벌레 이물 검출 1건, '10년도에는 찐어묵에서 철수세미 1건 이었다. ${\bigcirc}$이러한 위해발생을 사전에 예방하기 위해 중점관리해야 하는 공정은 가열공정으로 판단되며, 금속등의 이물혼입 또한 중점적으로 관리할 필요성이 있다. ${\bigcirc}$ 본 업소에서 생산하는 어묵류(튀김어묵, 찐어묵, 구운어묵)는 가열공정에서의 가열온도와 시간을 각각 설정하여 CCP 1로 관리하고 있으며, 품온이 $85^{\circ}C$이상으로 유지될 수 있도록 2시간마다 모니터링하고 한계기준 이탈여부를 기록하도록 하고 있다. ${\bigcirc}$또한 금속검출공정을 CCP 2로 관리하여 2mm${\varphi}$ 이상의 금속이물 혼입여부를 상시 확인하고 있으며, 금속검출기의 정상 작동여부를 4시간마다 모니터링하고 기록하도록 하고 있다. ${\bigcirc}$종합적인 공정 및 일반위생관리를 위해 개인위생 상태 냉동, 냉장고 온도 확인 등 총 29개 항목에 대하여 정기적 점검(매일 17, 주간 4, 월간 4, 분기 1, 연간 3)을 실시하고 있으며, ${\bigcirc}$따라서 지속적인 모니터링을 통해 미흡사항의 원인으로 파악하고 문제점 제거를 위해 체계적이고 지속적인 관리가 필요하다.

  • PDF

냉동수산식품 HACCP 관리 기준

  • 식품의약품안전청
    • Food Industry
    • /
    • s.219
    • /
    • pp.24-60
    • /
    • 2011
  • ${\bigcirc}$ 본 업소는 수산물가공품(냉동어류, 냉동연체류, 조미가공품)을 생산하는 식품제조 가공업소로서 총 5명의 인원이 수산물가공품 8개 제품을 생산하여 매출액은(약 00원)이며 주로 집단급식소에 판매하고 있다. ${\bigcirc}$ 본 업소의 수산물가공품은 냉동생선 해동(또는 냉장생선 이용), 전처리(냉장제거 등) 이후 세척 후 급냉하여 포장하거나(냉동어류 및 냉동연체류) 가열 후 포장하여 급냉하는(조미가공품) 공정을 거쳐 생산된 제품으로 원료 취급과정에서의 오염이나 불충분한 가열, 교차오염 등으로 식중독균(병원성대장균, 황색포도상구균 등)과 원료 및 제조과정에서 이물(금속 등)이 혼입할수 있으며, ${\bigcirc}$ 이로 안한 주요클레임 발생사례는 최근 3년간 관계당국으로부터 대장균군 검출 3건, 소비자클레임 2건이 있었다. - 연도별 주요 클레임내용은 '08년도에는 대장균군 검출 3건, '09년도 냉동어류에서 날벌레 이물 검출 1건, '10년도에는 냉동연체류에서 철수세미 1건 이었다. ${\bigcirc}$ 이러한 위해발생을 사전에 예방하기 위해 중점관리해야 하는 공정은 세척공정(냉동어류 및 냉동연제류) 및 가열공정(조미가공품)으로 판단되며, 금속 등의 이물 혼입 또한 중점적으로 관리할 필요성이 있다. ${\bigcirc}$ 본 업소에서 생산하는 냉동어류 및 냉동연체류는 세척공정에서 세척시간과 세척수량, 원물량을 각각 설정하여 CCP 1로 관리하고 2시간마다 모니터링하고 있으며, ${\bigcirc}$ 조미가공품은 가열온도와 시간을 각각 설정하여 CCP 2로 관리하고 있으며, 품온이 $85^{\circ}C$이상 유지할수 있도록 2시간마다 모니터링하고 한계기준 이별여부를 기록하도록 하고 있다. ${\bigcirc}$ 또한 금속검출공정을 CCP 2로 관리하여 2mm${\varphi}$ 이상의 금속이물 혼입여부를 상시 확인하고 있으며, 금속검출기가 정상 작동여부를 4시간마다 모니터링하고 기록하도록 하고 있다. ${\bigcirc}$ 종합적인 공정 및 일반위생관리를 위해 개인위생 상태 냉동 냉장고 온도 확인 등 총 29개 항목에 대하여 정기적 점검(매일 17 주간 4 월간 4 분기 1, 연간 3)을 실시하고 있으며, ${\bigcirc}$ 따라서 지속적인 모니터링을 통해 미흡사항의 원인으로 파악하고 문제점 제거를 위해 체계적이고 지속적인 관리가 필요하다.

  • PDF

유소아의 기도이물에 대한 임상적 고찰

  • 오춘석;송달원;손영탁;최용식;김중강
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1995.04a
    • /
    • pp.93.1-93
    • /
    • 1995
  • 저자들은 1985년 9월부터 1995년 2월까지 계명대학교 의과대학 이비인후과에 내원한 환자중 기도이물을 의심하여 환기형 기관지경술을 시행한 54례의 유소아 환자들을 대상으로 임상적 고찰을 하여 다음과 같은 결론을 얻었다.1) 기도이물을 의심한 환자 54례중 4세 이하가 49례(90.7%)로 대부분을 차지하였고, 남녀의 비는 3.5:1 이었다. 2) 이물개재 시간별 분포는 7일에서 30일 이내가 13례(24.0%)로 가장 많았고 다음이 2일에서 3일이내로 12례(22.2%)였다. 3) 기도이물의 증상으로는 기침(85.1%), 호흡곤란(38,9%), 고열(31.5%) 등의 순이었다. 4) 기도이물의 종류로는 식물성이 23례(67.6%)로 가장 많았고, 이중 땅콩이 19례였으며, 금속류, 플라스틱류 순이었다. 5) 이물이 있었던 34례중 흉부단순 X-선 소견상 이상소견을 나타낸 경우는 32례(94.1%)였으며, 이중 폐기종이 가장 많은 빈도를 보였고, 식물성이물은 전례에서 이상소견을 보였다. 6) 기도이물을 의심한 환자 54례중 이물이 없었던 20(37.0%)례 모두 흉부단순 X-선 소견상 이상소견을 나타내었고 이중 폐렴이 10례(50%)로 가장 많았고 무기폐, 페기종의 순이었다. 7) 이물의 개재부위는 주기관지 26례(우:14, 자:12), 기관 6례, 성문 2례의 순이었다.

  • PDF

Endophthalmitis after Removal of an Intralenticular Foreign Body in Place without Symptoms for 20 Years (20년 동안 증상없이 잔존한 수정체 내 이물제거 후 발생한 안내염)

  • Choi, Young;Eom, Youngsub;Choi, Soo Youn;Lee, Bo Young;Kim, Eun Jee;Kang, Su-Yeon;Song, Jong Suk;Kim, Hyo Myung
    • Journal of The Korean Ophthalmological Society
    • /
    • v.60 no.5
    • /
    • pp.480-485
    • /
    • 2019
  • Purpose: We report a case of postoperative endophthalmitis in the cataract patient, associated with removal of an intralenticular foreign body that had remained in place without symptoms for 20 years. Case summary: A 45-year-old male visited our outpatient clinic complaining of gradual visual loss in his right eye over the past 3 months. In slit-lamp examinations, anterior capsular opacification, nuclear sclerosis, and posterior subcapsular opacity were observed in the right eye. Twenty years before, a tiny metallic projectile had hit his right eye, but slit-lamp examination at the time of injury did not reveal any intraocular foreign body. We decided to undergo cataract surgery. During phacoemulsification, a metallic foreign body was found in the lens and safely removed; then an intraocular lens was implanted. As hypopyon was evident 3 days later, we injected intravitreal antibiotics and applied fortified antibiotic eye drops to the right eye. The anterior chamber inflammation improved and the best-corrected visual acuity recovered to 1.0. Conclusions: Surgeon should be aware of that endophthalmitis could develop after cataract surgery with removal of an intralenticular foreign body that had been in place for 20 years. But did not trigger inflammation or cause any symptoms as the cataract progressed.