• Title/Summary/Keyword: 금속도재

Search Result 112, Processing Time 0.024 seconds

Porcelain Fracture in Metal Ceramic, All ceramic and Zirconia restoration (금속도재, 전장도재, 지르코니아 수복물에서의 도재 파절)

  • Cheolyeon Kim
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.32 no.2
    • /
    • pp.46-53
    • /
    • 2023
  • Porcelain fractures associated with metal ceramic(MC), all ceramic (AC), and zirconia restorations are common complications. Several factors of fracture are suggested; Property of materials, Design of the coping for metal ceramic, fabrication techniques, supporting structure, occlusal force, parafunctional habit are being considered. In this article, these factors are discussed in detail.

The Effect of Thickness of Porcelain on Shear Bond Strength Between Heat-Pressed Porcelain and Non-Precious Metal (도재의 두께가 하부금속과의 전단결합강도에 미치는 영향)

  • Jo, Jung-Min;Lee, Cheong-Hee;Lee, Kyu-Bok;Cho, Jin-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.223-232
    • /
    • 2012
  • The purpose of this study was to investigate the effect of various thickness of porcelain on shear bond strength between metal coping and porcelain. So, various thickness of feldspathic porcelain and heat-pressed porcelain were built up and compared. 120 metal cube($4{\times}4{\times}4mm$) specimens were prepared. 60 specimens were applied to feldspathic porcelain and the others were applied to heat-pressed porcelain by 1mm, 1.5mm, 2mm, 2.5mm, 3mm and 3.5mm thickness. The measurement of shear bond strength was performed by Instron universal testing machine. The following results were obtained from this study. 1. As thickness of feldspathic porcelain increases, shear bond strength has decreased. Feldspathic specimens with 1mm porcelain thickness were significantly stronger than other feldspathic subgroups. 2. There was no significant difference of shear bond strength according to porcelain thickness in heat-pressed porcelain group. 3. In comparison between subgroups with same thickness, feldspathic porcelain group had stronger shear bond strength than heat-pressed porcelain. There were significant difference between 1mm and 3mm porcelain thickness group. 4. In almost cases, fracture surface was found on both metal and porcelain surfaces. As thickness of porcelain was increased, metal exposure was decreased.

The fracture resistance of heat pressed ceramics with wire reinforcement (금속선 강화에 따른 열 가압 도재의 파절저항)

  • Jo, Deuk-Won;Dong, Jin-Keun;Oh, Sang-Chun;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.191-198
    • /
    • 2009
  • Statement of problem: Ceramics have been important materials for the restoration of teeth. The demands of patients for tooth-colored restorations and the availability of various dental ceramics has driven the increased use of new types of dental ceramic materials. Improved physical properties of theses materials have expanded its use even in posterior crowns and fixed partial dentures. However, ceramic still has limitation such as low loading capability. This is critical for long-span bridge, because bridge is more subject to tensile force. Purpose: The wire reinforced ceramic was designed to increase the fracture resistance of ceramic restoration. The purpose of this study was to evaluate the fracture resistance of wire reinforced ceramic. Material and methods: Heat pressed ceramic(ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Liechtenstein) and Ni-Cr wire(Alfa Aesar, Johnson Matthey Company, USA) of 0.41 mm diameter were used in this study. Five groups of twelve uniform sized ceramic specimens(width 4 mm, thickness 2 mm, length 15 mm) were fabricated. Each group had different wire arrangement. Wireless ceramic was used as control group. The experimental groups were divided according to wire number and position. One, two and three strands of wires were positioned on the longitudinal axis of specimen. In another experimental group, three strands of wires positioned on the longitudinal axis and five strands of wires positioned on the transverse axis. Three-point bending test was done with universal testing machine(Z020, Zwick, Germany) to compare the flexural modulus, flexural strength, strain at fracture and fracture toughness of each group. Fractured ceramic specimens were cross-sectioned with caborundum disc and grinded with sandpaper to observe interface between ceramic and Ni-Cr wire. The interface between ceramic and Ni-Cr wire was analyzed with scanning electron microscope(JSM-6360, JEOL, Japan) under platinum coating. Results: The results obtained were as follows: 1. The average and standard deviation in flexural modulus, flexural strength and fracture toughness showed no statistical differences between control and experimental groups. However, strain was significantly increased in wire inserted ceramics(P<.001). 2. Control group showed wedge fracture aspects across specimen, while experimental groups showed cracks across specimen. 3. Scanning electron microscopic image of cross-sectioned and longitudinally-sectioned specimens showed no gap at the interface between ceramic and Ni-Cr wire. Conclusion: The results of this study showed that wire inserted ceramics have a high strain characteristic. However, wire inserted ceramics was not enough to use at posterior area of mouth in relation to flexural modulus and flexural strength. Therefore, we need further studies.

Shear bond strength analysis of PFM metal and zirconia with different surface condition (PFM metal과 zirconia의 표면상태에 따른 전단결합강도 분석)

  • Jung, Jae-Kwan;Kim, Kyung-Ah;Lee, Su-Ok;Kim, Ki-Baek;Kim, Jae-Hong;Kim, Il-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4329-4335
    • /
    • 2014
  • This study examined the effects of the shear bond strength when the surface condition of the metal and zirconia, each being the lower structures, was different when determining the bond strength (metal group) of the metal lower structure with upper ceramics, and the shear bond strength (zirconia group) of zirconia lower structure with the upper ceramics in prosthetic appliances of metal-ceramic crown and zirconia-ceramic crowns. The metal groups were divided into a total of four groups: the group with no condition on the metal surface(NM), the group with sand-blasting(SM), the group with applied opaque ceramics(OM), and the group with applied opaque ceramics and sand-blasting(SOM). The zirconia groups were also separated into four groups: the group with no condition(NZ), the group with sand-blasting(SZ), the group treated with ZirLiner on the zirconia surface(LZ), and the group applied with ZirLiner along and sand-blasting(SLZ). To examine the effects on the shear bond strength according to the surface condition of each of the four metal and zirconia groups, SPSS was used to conduct one-way ANOVA. For metal-ceramic crowns, it would be best to apply opaque ceramics after sand-blasting on the surface of the metal, the lower structure. For zirconia-ceramic crowns, it is recommended to apply the ZirLiner after sand-blasting on the surface of zirconia, the lower structure.

A comparative study on the fracture behavior of zironia, glass infiltrated alumina and PFM full crown system (지르코니아, 유리침투알루미나 및 PFM 전부관 시스템의 파절 경향에 관한 비교연구)

  • Lee, Sang-Hyeok;Ahn, Jin-Soo;Kim, Myung-Ho;Lim, Bum-Soon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.235-242
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the fracture behavior of Zironia, glass infiltrated Alumina and PFM full crown system. Materials and methods: Fifteen crowns for each of 3 experimental groups (Zironia, glass infiltrated Alumina and PFM full crown) were made by the conventional method. The crowns mounted on the testing jig were inclined in 30 degrees to the long axis of the tooth and the universal testing machine was used to measure the fracture strength. Results: 1. The mean fracture strengths were $588.3{\pm}49.6MPa$ for zirconia system, $569.1{\pm}61.8MPa$ for PFM system and $551.0{\pm}76.5MPa$ for glass-infiltrated alumina system (P>.05). 2. The mean shear bond strengths were $25.5{\pm}5.6MPa$ for zirconia system, $38.9{\pm}5.0MPa$ for Ni-Cr alloy system and $39.4{\pm}5.1MPa$ for glass-infiltrated alumina system. 3. The chemical bonding was observed at interfaces between PFM or glass-infiltrated alumina and veneering porcelain, however, no chemical bonding was observed at interface between zirconia and veneering porcelain. Conclusion: With the study, the fracture strengths of PFM crown system had a higher fracture strength than conventional zirconia system crown and glass-infiltrated alumina crowns. and than the shear bond strengths glass-infiltrated alumina system had a higher shear bond strength than conventional PFM system and zirconia system.

Evaluation of Color Change according to Process Step of Fused Porcelain to SLM Method (치과용 레이저 선택가공 금속체의 도재 소성단계에 따른 색조변화 관찰)

  • Kim, Chi-Young;Chung, In-Sung
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.12
    • /
    • pp.236-242
    • /
    • 2010
  • The porcelain fused metal was made through the progressive fused process of porcelain on substructure of metal material. The substructure was made using novel SLM method. The objective of this study was to observe the color change of porcelain using spectrophotometer equipment according to porcelain fused step and production methods after conducting the process of casting and SLM method of the substructure. The color change by step was indicated that fused opaque porcelain groups(CN1, CC1, CT1, SC1, ST1) had color difference(${\Delta}E$=30) by comparison with fused body porcelain groups(CN2, CC2, CT2, SC2, ST2) and fused glazing porcelain groups(CN3, CC3, CT3, SC3, ST3) (p<0.05). and there was no color difference between the substrates(CN, CC, CT) made by the casting method and the substrates(SC, ST) made by the SLM method. so, the color change was expressed by fused change of porcelain, and this study showed that the color of porcelain fused metal made by the SLM method can be applied clinical trials.

Comparative study in marginal fit of a pressed ceramic and feldspathic porcelain fused to metal restoration (열-가압을 이용한 금속 도재관과 전통적인 금속 도재관의 변연 적합도 비교 연구)

  • Kim, Yoon-Young;Park, Won-Hee;Yoo, Dong-Yeob;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.273-279
    • /
    • 2010
  • Purpose: The purpose of this in vitro study was to compare the marginal adaptation of a ceramic-pressed-to-metal restoration with traditional metal-ceramic restoration. Materials and methods: Duplicating the prepared resin tooth, 20 metal dies were fabricated. Twenty metal copings of 2 groups which were metal ceramic restoration and pressed to metal restoration were fabricated. The marginal opening of each coping was measured with Microscope (BX 60M-36E $41D^{(R)}$: Olympus, Japan). After porcelain build-up, the marginal opening of metal ceramic restoration and pressed to metal restoration ($PoM^{(R)}$: Ivoclar vivadent., Liechtenstein) were also evaluated in the same method. The measurements were analyzed using Wilcoxon Signed Ranks test and Mann-Whitney U test. Results: Within the limits of this study, the results were as follows. 1. Metal-ceramic restorations in coping state ($64.93{\pm}12.48\;{\mu}m$) in compared with Metal ceramic restorations after porcelain build-up ($63.43{\pm}12.86\;{\mu}m$) had no significant difference in marginal adaptation. 2. Pressed-metal-ceramic restorations in coping state ($50.00{\pm}12.28\;{\mu}m$) in compared with Pressed metal ceramic restorations after porcelain build-up ($56.72{\pm}13.80\;{\mu}m$) had no significant difference in marginal adaptation. 3. Metal-ceramic restorations in compared Pressed-metal-ceramic restorations had no significant difference in marginal adaptation. Conclusion: Pressed-metal-ceramic restorations have the advantage of being technically less change through using of the lost-wax technique and this allows for the convenience of a full-contour ceramic wax-up as opposed to the more technique-sensitive layering method. Pressed-metal-ceramic restorations may be considered in clinic on the basis of the result of this study and the advantage of this system.

The Effect of a Au Based Bonding Agent Coating on Non-Precious Metals-Ceramic Bond Strength (비귀금속 합금에 적용한 Au Based Bonding Agent가 금속-도재 결합에 미치는 영향)

  • Lee, Jung-Hwan;Ahn, Jae-Seok
    • Journal of dental hygiene science
    • /
    • v.9 no.4
    • /
    • pp.405-412
    • /
    • 2009
  • The purpose of this study investigated the effect of Au coating on adhesion between porcelain matrix and metal substructure interface. Titanium, Ni-Cr alloy and Co-Cr alloy are well known as proper metal for the dental restorations. The success of a porcelain fused to metal (PFM) restoration depends upon the quality of the porcelain-metal bond. However, adhesion between dental alloys and porcelain is related to diffusion of oxygen during ceramic firing. The excessive oxidized layers make hard adhesion between dental alloy and ceramic. Ni-Cr and Co-Cr specimens were divided into test and a control group and Titanium specimens were divided into three test groups and a control group. Each group had 20 specimens. The adhesion characteristics of porcelain and metal with Au coating layer and without Au coating layer were observed with scanning electron microscopy(SEM). The adhesion was evaluated by a biaxial flexure test and volume fraction of adherent porcelain was determined by SEM/EDS analysis. Result of this study suggest that Au coating layer is effective barrier to diffuse oxide layer completely protect non-precious alloys from oxidation during the porcelain firing. The SEM photomicrographs of cross-section specimens showed a smooth interface between Au coating layer and metals and porcelain which suggested proper chemical bonding, and no gap, porosity were observed. The mode of failure was mainly adhesive for Ti tested specimens, but mixed failures with adhesive and cohesive were observed in Ni-Cr and Co-Cr specimens. The adhesion between non-precious metals and porcelain would not be improved by Au coating agent. However, It is suggested that the continuous study is required further investigation and development.

  • PDF

The effet of cooling rate on the residual stresses in the veneer ceramics of zirconia-ceramic restorations: a literature review (냉각속도가 지르코니아-도재 수복물의 전장도재 내 잔류응력에 미치는 효과에 관한 문헌고찰)

  • Chang, Jea-Seung;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.136-142
    • /
    • 2014
  • Nowadays, dental zirconia is widely used as a framework material for a fixed dental prosthesis as well as a single restoration. However, clinical studies have reported high incidence of veneer chipping of zirconia-ceramic restorations compared to that of metal-ceramics. Several factors were raised as the possible causes of veneer ceramic chipping, however, it is still in debate. Recently, residual stresses in the veneer ceramics after cooling process gathers attention as one possible cause of chipping and many studies reported that the rate of cooling significantly influenced the types and the amount of residual stress. The purpose of current review was to briefly describe the effect of cooling rate on the residual stress in zirconia-ceramics. It was also described that the different behavior of residual stress between zirconia-ceramics and metal-ceramics following different cooling rate.