• Title/Summary/Keyword: 극저체온 순환정지법

Search Result 2, Processing Time 0.021 seconds

The Thracoabdominal Aortic Replacement Using Deep Hypothermic Circulatory Arrest Technique (흉복부대동맥치환술에서 극저체온하순환정지법의 효과)

  • Woo, Jong-Su;Bang, Jung-Hee;Kim, Si-Ho;Choi, Pil-Jo;Cho, Kwang-Jo
    • Journal of Chest Surgery
    • /
    • v.39 no.3 s.260
    • /
    • pp.194-200
    • /
    • 2006
  • Background: Thoracoabdominal aortic replacement is an extensive operation that opens both the pleural cavity and abdominal cavity, which has high mortality and morbidity rate. The authors have reported 9 cases of the thoracoabdominal aortic replacement in 2001. Since 2003 we have applied the deep hypothermic circulatory arrest to the Crawford type I and II thoracoabdominal aortic replacement. Therefore, we analysed the effect of the changes in operative techniques. Material and Method: Between 1996 and 2005, we have performed 20 cases of thoracoabdominal aortic replacement. The underlying diseases were 8 cases of atherosclerotic aneurysm with 4 cases of ruptured aneurysm and 12 cases of aortic dissection with 10 cases of a previous operations. According to Crawford classification, there were 2 cases of type I, 7 cases of type II, 1 case of type III, 7 cases of type IV, and 3 cases of type V. We compaired the results of the patients who underwent thoracoabdmoninal replacement before 2001 which already has been reported and after then. Result: Before 2001 we have performed 9 cases of thoracoabdominal replacement and 5 patients were died of the operation. All three patients with type I and II were died. There was no case of thoracoabdominal replacement between 2001 and 2002, but after 2003 we have performed 11 cases of thoracoabdominal replacement which involved 1 case of type I, 5 cases of type II, 1 case of type III, 2 cases of type IV and 2 cases of type V. There was no mortality and no fetal complications. Conclusion: The deep hypothermic circulatory arrest is a safe method of extended thoracoabdominal aortic replacement.

Surgical Experience of the Remnant Thoracoabdominal Aortic Replacement after Aortic Surgery (대동맥수술 후 잔존 흉복부대동맥치환술에 대한 임상 경험)

  • Cho, Kwang-Jo;Woo, Jong-Su;Choi, Pil-Jo;Bang, Jung-Hee
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.49-54
    • /
    • 2008
  • Background: Aortic diseases tend to involve the entire aorta. Hence, there is the constant possibility of the need for a secondary operation at the remnant aorta. This study analyzed our cases of secondary aortic surgery in order to determine its characteristics and problems. Material and Method: Between April 2003 and June 2007, 12 patients (6 male and 6 female) underwent thoracoabdominal aortic replacement as a secondary aortic operation. Their clinical courses were analyzed. Four of the patients underwent lower thoracobadominal aortic replacement under the normothermic femorofemoral bypass, and the others underwent an entire thoracobdominal aortic replacement under deep hypothermic circulatory arrest. Result: There was no death or paraplegia. As local complications, there were 3 cases of wound infection and 2 cases of an immediate reoperation caused by bleeding and one case of delayed wound. revision for a contaminated perigraft hematoma. As a systemic complication, there was one case of renal insufficiency, which required hemodialysis and one case of respiratory insufficiency that needed prolonged ventilator care. The mean admission period was $30{\pm}21$ days. All the patients were followed up for $626{\pm}542$ days without reoperation or other problems. Conclusion: Using properly selected patients and a careful approach, thoracoabdominal aortic replacement can be performed safely as a secondary aortic surgery.