• Title/Summary/Keyword: 굴곡 효과

Search Result 186, Processing Time 0.021 seconds

A Study of Damage Sensing and Repairing Effect of CNT Nanocomposites (손상감지용 CNT 나노복합재료의 손상 감지능 및 보강효과 연구)

  • Kwon, Dong-Jun;Wang, Zuo-Jia;Choi, Jin-Young;Shin, Pyeong-Su;Park, Joung-Man
    • Composites Research
    • /
    • v.27 no.6
    • /
    • pp.219-224
    • /
    • 2014
  • Nancomposites manufacture has been developed rapidly, because of reinforcing effects of CNT in terms of mechanical, electrical and thermal properties. In this study, 10 wt% CNT paste was fabricated with good dispersion state and easy processability. Damage sensing and reinforcing effect of CNT paste were investigated in nanocomposites. 10 wt% CNT paste exhibited better tensile and flexural properties than those of general 1 wt% CNT nanocomposites. To observe the healing effect of CNT paste, a crack was made artificially with 30wt% CF30wt%/PP composites, and the CNT paste was filled inside the crack. The damage sensing of CNT paste in CF30wt%/PP composites was investigated by electrical resistance measurement and mechanical tests. CNT paste exhibited good reinforcing effect in mechanical properties of CF30wt%/PP composites, and this reinforcing effect was getting better with larger cracks. The reason was because CNT paste had good interfacial adhesion with CF30wt%/PP composites to resist crack propagation. In electrical resistance measurement, there was a jump in electrical resistance signal at the adhesion interface. The jumping signal could be used to predict fracture of CF/PP composites. CNT nanocomposites for damage sensing had crack reducing effect and damage detection using electrical resistance method.

Analysis of alveolar molding effects in infants with bilateral cleft lip and palate when treated with pre-surgical naso-alveolar molding appliance (양측성 순구개열 신생아 환자의 수술전 비치조 정형장치 치료에 의한 치조골 조형(molding) 효과의 분석)

  • Nahm, Dong-Seok;Yang, Won-Sik;Baek, Seung-Hak;Kim, Sukwha
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.649-661
    • /
    • 1999
  • The goals of this study were 1) to present pre-surgical naso-alveolar molding (PNAM) appliance for bilateral cleft lip and palate treatment and 2) to evaluate the effects of the PNAM appliance on the alveolar molding of the premaxilla and the lateral segments. Subjects consisted of 8 bilateral cleft lip and palate infants (7 males and 1 female, mean age at first visit = 61.6 days after birth) who were treated with PNAM appliances in Department of Orthodontics, Seoul National University Dental Hospital. Average alveolar cleft gap between the premaxilla and the lateral segment was $8.09{\pm}5.03mm$ and average duration of alveolar molding treatment was $8.8{\pm}3.1$ weeks. These patients' models were obtained at initial visit (T0) and after alveolar molding (T1). 20 linear and 14 angular variables were measured by using photometry and digital caliper, All statistical analyses were performed by Microsoft Excel 97 program. Paired t-test was used to discriminate the effect of alveolar molding by PNAM appliance. 1. Closure of the alveolar cleft gap in bilateral cleft cases by molding therapy was completed successfully, 2. Alveolar molding inhibited outward growth of lateral segments and produced inward bending of lateral segments. 3. By bending the anterior part of the vomer, the premaxilla could be rotated and moved. posteriorly via alveolar molding. Conclusion This appliance can be applied to bilateral cleft lip and palate infants with satisfactory results before cheiloplasty.

  • PDF

A STUDY CONCERNING THE CHARACTERISTICS OF KOREAN NI-TI ALLOY ORTHODONTIC WIRE (국산 Ni-Ti합금 교정용 선재의 특성에 관한 연구)

  • Park, Dong-Ok;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.25 no.2 s.49
    • /
    • pp.187-200
    • /
    • 1995
  • To estimate the characteristics of Korean Ni-Ti alloy orthodontic wire, this study investigated compositions, tensile properties, bending properties, heat treatment effects, and ion releasing degrees, and compared these characteristics to those of the imported Ni-Ti alloy wire. The results obtained are as follows ; 1. Ti and -Ni elements in ORTHOLLOY were in a range showing superelasticity, and there was a little difference in the Ni and Ti contents of ORTHOLLOY as compared with those of SENTALLOY. 2. The results of the tensile test concerning ORTHOLLOY exhibited a superelastic effect, indicating an area of a definite amount of stress in spite of the changes in the range from $2\%\;to\;8\%$ in the strain rate. 3. ORTHOLLOY presented higher load values than SENTALLOY in the same deflection values when the wire was tested in three-point bending. A load range displaying a superelastic effect was 80-l00g, 140-l80g, and 130-200g respectively, in wire diameters of 0.014', 0.016', and 0.018' 4. By heat treatments at $400^{\circ}C$ and at $500^{\circ}C$, a load range showing the effect of superelasticitly was lessened by the duration of the heat treatment time. The superelastic effect was destroyed as a result of the 10 minutes heat treatment at $600^{\circ}C$. 5. The quantity of the Ni ion released from ORTHOLLOY, tended to be greater than the amount of released Ni ion in SENTALLOY. The Co ion released was very little(<0.01ppm) in SENTALLOY and ORTHOLLOY irrespective of the lapse of time. Released Ni ions on the 1st day were at the maximum, and the releasing rate showed plateaus after three days. 6. The surface morphology of SENTALLOY was relatively regular irrespective of the lapse of rime, and the corrosion tendency was not observed. However, the surface morphology of ORTHOLLOY was rather irregular and shelved fitting corrosion after immersion.

  • PDF

Formation Control of Calcium and Magnesium Compounds by Electrodeposition Process in Seawater (해수 중 전착 프로세스에 의한 칼슘 및 마그네슘 화합물의 형성 제어)

  • Park, Jun-Mu;Hwang, Seong-Hwa;Choe, In-Hye;Gang, Jun;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.164-164
    • /
    • 2017
  • 해양환경 중 많이 사용되는 철강재료들은 그 가혹한 부식환경에 대응하기 위하여 일반적으로 피복 도장방식법이나 음극방식법이 적용되고 있다. 여기서 음극방식법은 선박 및 해양구조물의 해중부 부식에 대해 가장 효과적인 방식법으로 알려져 있다. 한편, 이와 같이 해수 중 철강재에 음극방식을 적용할 경우, 피방식체인 그 강재 표면에 해수 중 용존된 산소의 음극환원 반응이 일어나며 국부적인 알카리 표면 조건을 형성시켜 $Mg(OH)_2$$CaCO_3$의 막을 석출시킨다. 이와같이 음극방식 중 형성된 전착물은 방식해야 될 표면적을 감소시켜 방식전류밀도를 감소시키는 효과가 있는 것으로 보고되고 있다. 이렇게 석출된 전착물은 음극표면에 부분적으로 형성되고, 여러 가지 환경 조건 등의 영향을 받아 그 피막의 형성 정도도 가늠하기 어렵기 때문에 음극방식 설계 시 그 정도에 따른 영향을 고려-반영하기가 곤란하다. 또한 이 전착물은 그 형성 메커니즘에 관한 해석이나 강도, 균일한 밀착성, 장기적인 방식효과 및 효율성 등이 아직 충분히 입증되어 있지 않은 실정에 있다. 따라서 본 연구에서는 해수 중 다양한 전착 프로세스에 의해 제작된 전착물의 기간별, 도장코팅 종류별 특성변화를 분석 및 평가하고, 전착물에 의한 희생양극 소모전류 변화 측정 분석을 통해 전착막을 균일하고 치밀하게 형성시키기 위한 최적의 조건을 찾고자 하였다. 또한 석출속도, 밀착성 및 내식특성을 향상시키기 위해 해수 중 기체를 용해시켜 제작한 막의 특성을 분석-평가하였다. 본 연구에 사용된 강 기판은 일반구조용강(KS D 3503, SS400)으로 ${\varnothing}42.7{\times}1,000mm{\times}4.0t$의 형상으로 제작하였다. 인가된 전류밀도는 1, 3 및 $5A/m^2$이고 도장 코팅 종류별 전착 석출물의 형성차이 비교 분석을 위한 실험은 선박 및 해양구조물에 많이 사용되는 Universal Epoxy 도료 2종을 선정하여 진행하였다. 또한 Steel Wire Mesh의 영향을 알아보기 위해 Mesh를 설치하여 실험을 진행하였다. 기간별-도장 종류별 외관관찰, 전착물의 두께 측정, SEM, EDS 및 XRD를 통해 막의 모폴로지, 조성원소 및 결정구조를 분석하였으며, 전착물의 내식성과 내구성을 평가하기 위해 테이핑 테스트(Taping Test) 및 전기화학적 양극분극 시험을 실시하였다. 희생양극 소모율에 대한 전착물의 영향을 확인하기 위해 외부전원을 인가하여 전착 피막을 형성시킨 강 기판에 희생양극을 연결하여 희생양극 소모효율 측정 시험을 진행하였다. 전착물의 석출량은 시간 및 전류밀도의 증가에 따라 비례하여 증가하였으며, 음극전류 인가 시 금속과 용액 계면 사이의 확산층에서 발생한 $OH^-$ 이온으로 인해 금속과 용액 계면 사이 pH가 부분적으로 증가하여 $Mg(OH)_2$ 화합물이 많이 생성되는 것으로 확인되었다. 또한 Mesh의 부착으로 평활하지 않게 형성된 미세한 굴곡구조 및 표면적 증가로 인하여 단계적으로 피복되는데 필요한 시간이 지연되면서 $CaCO_3$에 비해 $Mg(OH)_2$ 화합물이 상대적으로 증가한 것으로 사료된다. $CaCO_3$(Aragonite) 구조는 견고한 피막으로 치밀하고 화학적 친화력이 높아 우수한 밀착성을 보였으며 전착물의 영향으로 양극 전류가 감소하였고, 이로인해 방식전류 절감효과를 얻을 수 있을 것으로 기대된다.

  • PDF

Exploring the Use of Melody During RAS Gait Training for Adolescents with Traumatic Brain Injury: A Case Study (외상성 뇌손상 청소년 대상 리듬청각자극(RAS) 보행 훈련 시 선율 적용 사례)

  • Park, Hye Ji
    • Journal of Music and Human Behavior
    • /
    • v.12 no.2
    • /
    • pp.19-36
    • /
    • 2015
  • The purpose of this study was to examine the effects of rhythmic auditory stimulation (RAS) on gait parameters, with and without the presence of a melody, for adolescents with traumatic brain injury (TBI). Three adolescents with TBI received a total of ten individual RAS training sessions. At pre and posttest, spatiotemporal parameters including cadence, velocity and kinematic parameters were measured using the VICON 370 Motion Analysis System. The results showed no significant difference in gait velocity between the two conditions, thus the presence of the melody condition did not impact the outcome of RAS gait training. On the other hand, all participants showed improvement in gait function after RAS training. The cadence, velocity, stride length, and symmetry were increased and the stride time was reduced after training. The motion analysis demonstrated that the movement patterns of hip and knee joints improved, as they were more similar to normal gait, which indicates that the walkings tance became more stable. The research findings indicate that rhythm is the primary factor in mediating gait functions via RAS training. This study also supports that RAS training can effectively improve the gait function for adolescents with TBI.

Estimating Air Temperature over Mountainous Terrain by Combining Hypertemporal Satellite LST Data and Multivariate Geostatistical Methods (초단주기 지표온도 위성자료와 다변량 공간통계기법을 결합한 산지 지역의 기온 분포 추정)

  • Park, Sun-Yurp
    • Journal of the Korean Geographical Society
    • /
    • v.44 no.2
    • /
    • pp.105-121
    • /
    • 2009
  • The accurate official map of air temperature does not exist for the Hawaiian Islands due to the limited number of weather stations on the rugged volcanic landscape. To alleviate the major problem of temperature mapping, satellite-measured land surface temperature (LST) data were used as an additional source of sample points. The Moderate Resolution Imaging Spectroradiometer (MODIS) system provides hypertemperal LST data, and LST pixel values that were frequently observed (${\ge}$14 days during a 32-day composite period) had a strong, consistent correlation with air temperature. Systematic grid points with a spacing of 5km, 10km, and 20km were generated, and LST-derived air temperature estimates were extracted for each of the grid points and used as input to inverse distance weighted (IDW) and cokriging methods. Combining temperature data and digital elevation model (DEM), cokriging significantly improved interpolation accuracy compared to IDW. Although a cokriging method is useful when a primary variable is cross-correlated with elevation, interpolation accuracy was sensitively influenced by the seasonal variations of weather conditions. Since the spatial variations of local air temperature are more variable in the wet season than in the dry season, prediction errors were larger during the wet season than the dry season.

Analysis of Contaminant Transport in the Ground using the Lattice-Boltzmann Method (격자 볼츠만 방법에 의한 지반 내 오염물질의 거동 분석)

  • Kang, Dong Hun;Yun, Tae Sup
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6C
    • /
    • pp.267-274
    • /
    • 2012
  • The conventional approach to evaluate the contaminant transport in soils adopts the macro-scale implementation while the pore configuration and network is a dominant factor to determine the fate of contaminant. However, the observation of fate and transport at pore scale may not be readily approachable because of the computational expenses to solve Navier-Stokes equation. We herein present the 2D Lattice-Boltzmann method that enables to assess the local fluid velocity and density efficiently for the case of single phase and multi-components. The solute fate spatio-temperal space is explicitly determined by the advection of fluid flow. Two different types of idealized pore space provides the path of fluid. Also, solute transport, the velocity field and average concentration of solute are computed in steady state. Results show that the pore geometry such as tortuosity mainly affect the solute fate. It highlights the significance of the pore configuration and shape in granular soils and rock discontinuity in spite of the equivalent porosity.

Effect of Bamboo Fiber Grinding on the Mechanical, Thermal, Impact, and Water Absorption Properties of Bamboo/Poly(lactic acid) Biocomposites (대나무/폴리락틱산 바이오복합재료의 기계적, 열적, 충격 및 수분흡수 특성에 미치는 대나무섬유 분쇄의 영향)

  • Cho, Yong Bum;Cho, Donghwan
    • Journal of Adhesion and Interface
    • /
    • v.13 no.3
    • /
    • pp.121-130
    • /
    • 2012
  • In the present study, bamboo/PLA biocomposites through injection molding process using extruded bamboo/PLA pellets with the fiber contents of 30, 40, and 50 wt% according to the presence and absence of bamboo fiber grinding, respectively, were fabricated and their mechanical, thermal, impact, and water absorption properties were explored. Compared to neat PLA, the flexural modulus, tensile modulus, storage modulus and impact strength of bamboo/PLA biocomposites were considerably increased. In particular, the moduli were further increased by introducing the ground bamboo fibers. In addition, use of the ground bamboo fibers was effective to enhance the long-term water resistance of the biocomposites. The heat treatment temperature of neat PLA was improved by 16% by incorporating the bamboo fibers and the fiber grinding effect was slight. The incorporation of the ground bamboo fibers to PLA did not influence the tensile strength and impact toughness of bamboo/PLA biocomposites.

The Effects of the Band Type Foot Drop Device (밴드형 첨족예방기구의 효과와 유용성)

  • Kang Hyun-Sook;Kim Won-Ock;Lee Hya-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.3
    • /
    • pp.391-400
    • /
    • 2000
  • A long-term bed rest results in an inevitable foot drop. Yet preventive device such as a foot board and high-neck tennis shoes, are not widely used. This study was conducted to compare the effects of a pillow-type foot board with that of the band-type device. The band-type device of a resonable price is designed for an effective prevention of foot drop, and the convenience for it use. Among the non-equivalent control group design, foot drop preventive effects, usefulness of the device, as well as its cost effectiveness were examined. The study was carried out for four months from December 1999, and its subject had been patients and nurses of two intensive care units at K medical center in Seoul. According to the study purpose, the data collected were analyzed by $x^2-test$ and t-test. The results are as follow : 1. The ROM of ankle joint is promoted in the experimental group with a band-type device comparing the control group with a pillow type one. Dorsiflexion is particularly increased in the experimental group as compared with the control group, while planterflexion hardly shows any change. 2. The usefulness score of the experimental group nurses using the band-type device (23.97) is higher than that of the control group nurses (18.88). 3. In an aspect of the unit production cost, band-type devices are low-priced compare with pillow-type or other foot board (wooden) or high-neck tennis shoes. In summary, the newly developed band-type device is both useful and preventive for a foot drop. It is also desirable regarding to the production cost and the cost effectiveness. This fact proves that the new anti-foot drop device could be practical both for clinical care and home care. Yet the results were obtained by some subjects, it should be used after a further examination. More effective nursing intervention could be observed throughout general studies, including proper positioning and foot and ankle exercises which are the important variables of the foot drop prevention.

  • PDF

Effects of lower extremity stability by kinesio taping method in elite speed skating athletes' one-leg jumping (엘리트 빙상 선수들의 외발점프 훈련 시 키네시오 테이핑요법이 하지관절 안정성에 미치는 영향)

  • Lee, Young-Seok;Kwak, Chang-Soo;Lee, Chung-Il;Kim, Tae-Gyu
    • Journal of Digital Convergence
    • /
    • v.13 no.8
    • /
    • pp.495-502
    • /
    • 2015
  • The purpose of this study was to investigating the effect of taping knee by testing the difference on kinetic variables of lower extremity when speed skating athletes jump on one leg. The results were as follows. The height of jumping after taping was higher, but the vertical height was not different according to taping. On take-off(TO), the horizontal and anterior-posterior maximum impulse force were decreased while the vertical maximum impact force was increased after taping. On landing(LD), the anterior-posterior maximum impulse force was decreased but the horizontal and vertical maximum impulse force were increased. TO, the impulse showed low after taping and the impulse dropped largely LD. The knee's moment of extension, eversion were reduced after tapping TO. LD, the flection moment of knee was decreased, but the inversion moment was increased after tapping. This study implies that the knee tapping helps injury prevention and performance enhancement, sports medicine convergence are needed.