• Title/Summary/Keyword: 국소환기

Search Result 53, Processing Time 0.033 seconds

Study on the Performance Improvement of Ventilation Fan Installed in Walls of Underground Parking Lots (벽체 매립형 환기용 팬 성능개선에 관한 연구)

  • Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.206-211
    • /
    • 2014
  • The objective of the present study was to identify ventilation problems, and also to suggest new axial fan systems for the improvement of IAQ in the underground parking lots. Numerical results for air mean-velocity, local mean age, and sound power level are presented along with some of fan angles. The results showed the influence of airflow patterns on the fan performances installed in the underground parking lots. Discharge air volume is increased with the angle of the blade. And also, the main factors affecting the noise of the ventilation fan was found to be a rotational speed.

A Study on Heat Transfer Characteristics for Cross Flow Heat Exchanger of Staggered Arrangement (어긋나기배열 직교류 열교환기의 열전달특성에 관한 연구)

  • Yoo, Jae-Hwan;Yoon, Jun-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1016-1023
    • /
    • 2012
  • Because heat exchanger consists of many circular tubes, the analysis of local heat transfer and pressure drop at the surrounding of circular tubes, performance and calculation of size, economics play important roles in design. In this study, This study conducted experiment and analysis in order to observe convective heat transfer coefficient LMTD (logarithm mean temperature difference) and pressure losses according to water temperature and air flow rate using a cross flow heat exchanger of staggered arrangement. This heat exchanger was composed of staggered arrangement for five rows and seven columns of tube banks, and the condition of experiment and analysis are $40{\sim}65^{\circ}C$ of water temperature and $5.0{\sim}12.3m^3/s$ of air flow rate. As a result of it, since air density decreases as water temperature and flow rate increases, Reynolds number decreases with characteristics of low flow velocity but mean heat transfer coefficient increases with air flow rate increase, heat transfer performance has been improved and pressure losses decreased. And since heat transfer rate shows about 8~12% and pressure drop around 0.01~7.5% error as the analysis result, the feasibility of this study could be evaluated.

An Experimental Study on Frosting of Humid Air-flow on a Surface with Local Cooling for Heat Exchanger Design (열교환기 설계를 위한 국소 냉각 표면위에서의 습공기 유동의 착상실험)

  • Kwon, Jeong-Tae;Lim, Hyo-Jae;Park, Kyoung-Woo;Kim, Chang-Eob;Kim, Kyung-Min;Kwon, Young-Chul
    • Journal of Energy Engineering
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • The present study has been conducted to understand the heat and mass transfer characteristics of humid airflow in frosting conditions. A flat plate of aluminum was used for the simulation of flat surface part of the fin of the heat exchanger. The aluminum surface temperatures were measured and analyzed to clarify the heat and mass transfer characteristics under frosting conditions. Also, the pressure drops were measured to clarify the air-blocking effect of frost in the mini channel of the air-side hoot exchangers. A data reduction method was developed far the analysis of local characteristics of humid air under frosting conditions.

Exposure to Styrene in the Lamination Processes with Fiberglass-Reinforced Plastics: Health Diagnosis Case Report (유리섬유강화 플라스틱을 이용한 적층공정 근로자들의 스티렌 노출 평가: 보건진단 사례)

  • Choi, Sangjun;Jeong, Yeonhee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.126-133
    • /
    • 2015
  • 연구목적: 이 연구는 노동부의 보건진단 명령에 의해 유리섬유 강화플라스틱(FRP)을 이용한 이중벽 탱크 제조 사업장의 적층 공정 근로자들을 대상으로 스티렌 노출 특성을 평가하기 위해 수행되었다. 연구방법: 스티렌의 주요발생원 파악을 위해 불포화 폴리에스테르 수지(UPR), 경화제, 조색제, 세척액 등의 원료 내 스티렌 함유량을 가스크로마토그래피 질량분석기(GC-MS)를 이용하여 분석하였다. FRP 적층 공정에 근무하는 작업자들을 대상으로 NIOSH 1501 공정시험법에 의해 공기 중 스티렌 노출 농도에 대한 개인노출 평가를 실시하였고, 생물학적 노출 지표로 뇨 중 만델릭산을 채취한 후 고성능액체크로마토그래피(HPLC)로 분석하였다. 또한 각 직무 특성과 단위작업 중심으로 스티렌에 대한 단시간 노출평가를 수행하였다. 연구결과: 스티렌의 함유량이 가장 많은 주요 원료는 중량비율로37%의 스티렌이 함유된 UPR이었다. 적층 공정의 FRP분무 작업자와 보조 작업자들 모두 스티렌의 8시간 가중평균 노출기준(20 ppm)을 초과하였다. 단시간 노출평가 결과 FRP분무 작업자의 경우 45.9 ppm에서 86.1 ppm 수준으로 FRP를 사용하지 않는 작업보다 통계적으로 유의하게 높은 수준이었다(P<0.01). 가장 높은 수준의 스티렌에 노출되는 단위작업은 FRP를 이용하여 1차 코팅 하는 작업으로 특별한 관리가 필요하였다. 결론: 보건진단을 위해 실시한 이중벽 탱크 제조 사업장의FRP 적층 공정 작업자의 스티렌 노출수준은 노출기준을 초과할 정도로 높은 수준이었다. 그러나 탱크를 천장에 매달고 돌리면서 적층작업을 수행하기 때문에 적절한 국소환기 시스템을 구축하는데 어려움이 있다. 따라서 적절한 방독마스크 착용으로 스티렌 노출 예방이 필요하였다.

A Study on Numerical Analysis and Performance Improvement of Ventilation Systems in Coating Room (코팅 룸 배기시스템 수치해석 및 성능개선에 대한 연구)

  • Lee, Ki Yeon;Kim, Kug Weon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2086-2091
    • /
    • 2013
  • One of the most important objects for the industrial ventilation is to protect worker's health from the harmful substances. Mainly in industrial ventilation, the harmful substances broken out through manufacturing process are to be quickly emitted outside. Recently the importance of the industrial ventilation increases with the recognition change of industrial ventilation from manufacturing focusing to human focusing. In this paper, the air flow simulation inside the coating room is performed. All the coating room and the ventilation system are modeled by SolidWorks program and air flow distribution and ventilation performance are analyzed by Flow simulation program. And the air flow directions and the air flow velocities inside the coating room are enhanced with the use of local ventilation.

The Effect of refrigerant pass & distribution in aluminum parallel flow heat exchanger (알루미늄 평행류 열교환기에서 냉매패스와 분배량 변화의 영향)

  • Kim, Jeong-Sik;Kim, Nae-Hyun;Kim, Kwang-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3546-3552
    • /
    • 2009
  • In this study, an analysis code was created for a 190*650*25-mm (W*H*D) parallel-flow evaporator, and research was done on how to increase the heat transfer rate of aluminum PF heat exchanger for application in IDU. After varying the R410A refrigerant up-down flow to two and three passes and the distribution ratio to 1:1:1 and 1:2:2, it was determined that the two-pass flow has a 30% higher partial heat transfer rate and a 25% lower heat transfer coefficient compared to the three-pass flow. As for the distribution ratios of the three-pass flow, 1:1:1 was found to have a lower refrigerant pressure loss than 1:2:2 distribution. It was assumed, though, that the refrigerant distribution had a uniform flow and that its value was thus overestimated in the actual case of maldistribution in each pass.

Hazards of Chloroprene and the Workplace Management (클로로프렌의 유해성과 작업환경 관리)

  • Kim, Hyeon-Yeong;Lim, Cheol-Hong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.3
    • /
    • pp.1-8
    • /
    • 2015
  • In this study, we performed risk assessment of chloroprene by hazard evaluation and workplace investigation. The chemical is used to manufacture of shoes, tires, adhesives, and classified as IARC category 2B (possibly carcinogenic to humans) and target organ systemic toxicity. It is used about 1,300 tons per year in 27 sites. It was calculated the risk of carcinogenesis with chloroprene by Monte-carlo simulation that the averages are 2,199 and 26,404 in each case of working less than 15 minutes per day with local exhaust ventilation and over 4 hours per day without local exhaust ventilation. The risk of target organ systemic toxicity are 4.10 and 169.06 with high correlation with working time to be longer and with ventilation system. Therefore, it is recommended that the local exhaust ventilation and respirators to prevent occupational cancer and target organ systemic toxicity with chloroprene. Especially it is determined that there is a need to strengthen the workplace exposure limit (TWA 10 ppm) in Korea since it is managed with TWA less than 5 ppm ($18mg/m^3$) by the United States Occupational Safety and Health Administration (OSHA) as well as it has carcinogenicity, reproductive toxicity.

Etiology of Community-acquired Bacteremia in Healthy Children (건강한 소아에서 지역사회 획득 균혈증의 원인균)

  • Kim, Hyung Tae;Jang, Hyun Oh;Moon, Jin Soo;Nam, Seung Yeon;Kim, Dong Wook;Lee, Chong Guk;Cho, Chong Rae
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.7
    • /
    • pp.716-722
    • /
    • 2005
  • Purpose : A full view of the spectrum of all bacterial diseases in healthy children is essential to the establishment of public health priorities. Accurate information on the relative importance of the various pathogens in terms of the age of the affected patients, the site of infection and the case fatality rate are valuable to the clinician in choosing antimicrobial treatments. Methods : Fifty-nine episodes of bacteremia were analysed. Data were collected at Ilsan Paik Hospital from January 2000 to December 2003. Analysis of each collected episode included isolating pathogen from blood culture, diagnosis, hospital course, isolating pathogens from other tissue sites, and studying results of antimicrobial sensitivity tests. Results : Fifty-nine cases of community-acquired bacteremia were reviewed. The most common pathogen was Staphylococcus aureus(11 cases, 18.6 percent), followed by Salmonella(10 cases, 16.9 percent), E. coli(7 cases, 11.9 percent), Streptococcus pneumoniae(five cases, 8.5 percent), Streptococcus viridans(5 cases 8.5 percent). The most common diagnosis was bacteremia without an indentified focus(61 percent), followed by meningitis(12 percent), bacteremia with enteritis(10.2 percent) and bacteremia with urinary tract infection(8.5 percent). Salmonella was still an important causative agent of bacteremia. The relative importance of Haemophilus influenza and Streptococcus pneumoniae was lower than in other studies. The most common organism responsible for bacteremia without an identified focus was Staphylococcus aureus. The case-fatality was 3.4 percent for all cases of bacteremia. Conclusion : We reviewed the etiology of community-acquired bacteremia. These data may be useful in the establishment of public health priorities and serve as a reference for selection of antibiotics in the empirical therapy of suspected invasive bacterial infection.

Design of a Local Ventilation System in the Non-Standard Air Condition using the Spreadsheet Model (스프레드시트 모델을 이용한 비표준 공기상태에서의 국소환기시스템의 설계)

  • 조석호
    • Journal of Environmental Science International
    • /
    • v.6 no.6
    • /
    • pp.645-658
    • /
    • 1997
  • A study on ventilation design using the spreadsheet model is carried out to propose means of available design. A sample of complex ventilation system In the non-standard condition Is used to illustrate thins spreadsheet model. In developing the spreadsheet model, this study has attempted to it general by using computional equations and design parameters that can be readily applied to any spreadsheet software. Also, most design data is contained in the spreadsheet template. This template provides the same design information as the ACGIH worksheet, and operates Quickly and emclenuy, and is fiexible enough to use under different conditions. This spreadsheet model allows the ventilation engineer to design quickly and accurately the ventilation system, without spending too much effort In the design process. By storing on computer and diskette, the design data computed finally can be used as a permanent record of specific ventilation system, and because of finally to be able to design over and over again while making only slight changes to the Input data, the spreadsheet model is used availably to accomplish the design optimazation by redesign and troubleshooting by review from field measurements. Also, the spreadsheet model is available for designing ventilation system under different condition or evaluating existing system or design drawing, because changes In the layout or formulae can be readily made to fit the needs of the designer.

  • PDF

Local Heat Transfer Characteristics on Fin Surface of Plate Fin-Oval Tube with Delta Wing Vortex Generators (Plate Fin-Oval Tube 열교환기에서 익형 와류발생체에 의한 Fin 표면에서의 국소 열전달에 대한 특성)

  • Shin, Seok-Won;Chung, In-Kee;Kim, Soo-Youn
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.10
    • /
    • pp.757-766
    • /
    • 2009
  • In the present study, the effect of delta-wing vortex generators(DWVG) on the local heat transfer of the plate fin-oval tube was experimentally analyzed for Reynolds numbers for 2000, 2500 and 3200. The local heat transfer coefficient of the fin surface for four type DWVGs was measured by the naphthalene sublimation technique. As the results, the distribution of the heat transfer coefficient at rear of DWVGs showed longitudinal contours for common flow down DWVGs and wavy contours for common flow up DWVGs. The distribution showed many cell type contours at near wall and downstream for all DWVGs. Compared to case without DWVGs in present experimental tests, all DWVGs showed the best enhancement of heat transfer at Re=2000. Of 4 cases of DWVGs, D type showed the best enhancement of heat transfer.