• Title/Summary/Keyword: 구 접촉

Search Result 346, Processing Time 0.027 seconds

Influence of N-P-K Nutrient Levels on Ozone Susceptibility of Tomato Plants (N-P-K 양분 수준이 토마토의 오존 감수성에 미치는 영향)

  • Ahn, Joo-Won;Ku, Ja-Hyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.4
    • /
    • pp.352-357
    • /
    • 1998
  • This experiment was conducted to find out the effects of major nutrient levels(N, P, K) on ozone susceptibility of tomato plants(Lycopersicon esculentum Mill, cv. Pink Glory). Plants were grown in water culture system. A half-strength of Hoagland's nutrient solution was considered as a standard formulation($N_{100}$ $P_{100}$ $K_{100}$). The levels of major nutrients were adjusted through addition or removal of several fertilizer salts from the standard solution. Top growth was significantly decreased at the low nitrogen level or phosphorus removal condition. P- and K-contents of leaves were greatly decreased by removal of salts containing P and K from the nutrient solution. The rate of ozone injury was significantly increased when potassium was removed. However, the influence of nitrogen and phosphorus levels or high potassium level on injury occurrence did not show statistical significance compared to the standard solution. Ozone exposure resulted in reduction of chlorophyll, and increase of ethylene production, electrolyte leakage and malondialdehyde(MDA) contents. These changes were much more enhanced in plants grown at the potassium removal solution. Whereas the activity of superoxide dismutase(SOD) was low at the potassium removal treatment and this tendency remained after ozone exposure. These results indicated that potassium nutrient level in tomato plants is closely associated with the susceptibility to ozone injury.

  • PDF

Analysis of occlusal contact and guidance pattern during maximal intercuspal position and protrusive movement (최대교두감합위 및 하악 전방운동 시의 교합접촉 및 교합유도 양상에 관한 분석)

  • Kim, Jiyeon;Kim, Kang-Hyun;Noh, Kwantae;Kim, Hyeong-Seob;Woo, Yi-Hyung;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.199-207
    • /
    • 2013
  • Purpose: The importance of occlusal contacts of the natural dentition for durability of teeth, mandibular stabilization, and restorative dentistry is well known. The purpose of this study is to analyze the occlusal contact and guidance pattern of Koreans by evaluating the static occlusion on maximal intercuspal position and measuring dynamic occlusion during straight protrusion. Materials and methods: The occlusal contacts at maximal interincisal position and the occlusal guidance pattern during straight protrusion of 29 subjects were recorded with shimstock foil (Whaledent, Langenau, Germany), T-Scan III (Tekscan Inc., Boston, MA, USA), polyvinylsiloxane registration material (Genie Bite, Sultan Healthcare, Hackensack, NJ, USA) and compared. Occlusal registration procedures were repeated 3 times. The position was fixed to an upright position and the head position was fixed with the Frankfurt horizontal plane paralleling the horizontal plane. Fisher's Exact Test (R-General Public License, ver. 2.14.1) and Pearson's Test were used to assess the significance level of the differences between the experimental groups (${\alpha}=.05$). Results: When using shimstock foil, T-Scan III system, and polyvinylsiloxane registration material, most of the patients showed contact on anterior, premolar, and molar teeth during maximal intercuspal position. Approximately 51% of maximal intercuspal position showed anterior contact using shimstock foil. When examining the protrusive movement using shimstock foil and T-Scan III system, guidance pattern with the central incisor was the most common. Conclusion: During maximal intercuspal position, there were cases in which not all of the teeth showed occlusal contact. During mandibular protrusive movements, one or more maxillary central incisors frequently joined in straight protrusion and the posterior teeth were disoccluded. Therefore, the anterior teeth protect the posterior teeth, and vice versa. Thus, mutually protected occlusion should be applied when reconstructing occlusion.

Study on the Profile of Nut Bearing Surface and the Torque Coefficient of a High Strength Bolt Set (고장력 볼트세트의 자리면형상과 토크계수에 관한 연구)

  • Lee, Baek Joon;Sohn, Seung Yo
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.2 s.45
    • /
    • pp.143-150
    • /
    • 2000
  • Depending upon the combination of tolerances specified in the standards on bolt, nut and washer for high tension bolt sets, there arises center-to-center deviation between bolt and washer. This deviation nay cause loss of effective contact area between nut- and washer-faces, which leads to some dispersion of the torque coefficient K. By adapting circular arc surface instead of flat surface for the nut, it is shown through numerical analyses that the dispersion of the torque coefficient can be minimized. In this way, optimum radius of curvature of the nut bearing surface is proposed.

  • PDF

Evaluation of the proximal contact and comparison of methods for measuring in normal dentition (건강한 자연치열에서 인접면 접촉의 평가 및 측정방법에 따른 비교분석)

  • Ji-Eun Kim;Cheong-Hee Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.198-203
    • /
    • 2023
  • Purpose. The aim of this study was to evaluate the proximal contact with a dental floss compared to a celluloid strip and a metal strip in normal dental arch and investigate what the most effective method for measuring is. Materials and methods. The subjects of this study was consisted with 20 healthy adults (10 males and 10 females) who had normal dentition. A dentist with more than 5 years of clinical experience evaluated the proximal contacts using a dental floss method, a celluloid strip method, and a metal strip method. Statistical analysis were performed by the use of Mann-Whitney U test. A P-value < .05 was considered statistically significant in all analysis. In addition, in the evaluation of proximal contact using a dental floss, the measurement of proximal contact using a celluloid strip and a metal strip was compared. Results. 80 % of all proximal contact was proper. Proper proximal contact was observed at the posterior area compared to the anterior area (P < .05). And male had proper proximal contact at the anterior area, female had proper proximal contact at the posterior area (P < .05). The consistency analysis between the results of the celluloid strip and the metal strip experiment on the results obtained from the floss using the consistency scale Kappa index shows that using celluloid strip is more advantageous than using the metal strip. Conclusion. Only 80% of all proximal contact was proper. Using celluloid strips with various thickness for evaluating of proximal contact is considered to be helpful for accurate measuring of proximal contact.

Improvement of semiconductor contact hole filling of Copper by ionized cluster beam deposition technique (이온화클러스터빔 증착법에 의한 구리 박막의 반도체 접촉구 메움 향상에 관한 연구)

  • Baek, Min;Son, Ki-Wang;Kim, Do-Jin
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.2
    • /
    • pp.118-126
    • /
    • 1998
  • A study to improve filling of semiconductor contact holes by enhancement of the directionality of the source beams has been undertaken. The collimation of source beams was improved by the ionized cluster beam deposition technique with modification of the cell geometry. The collimation tested with neutral beam was excellent. But, the Cu flims were grown in a columnar mode due to the lack of surface mobilit of the impinged clusters. A shadow effect also caused cleavage and consequent discontinuity at the steos as films grow. By applying acceleration voltage, the columnar growth in a contact hole of 0.5 $\mu$m diameter and 1 $\mu$m height disappeared and considerable coverage at the side wall of the contacts as well as perfect bottom coverage were observed. These are all due to the assistants of the accelerated ionized clusters with high kinetic energy. Thus we demonstrated that the ICB deposition technique can be used to completely fill sub-half-micron contact holes with high aspect ratio.

  • PDF

Changes of bite force and occlusal contacts after stabilization splint therapy (교합안정장치 사용후 교합력 및 교합접촉의 변화양상에 관한 연구)

  • Park, Hyung-Soo;Kim, Kwang-Won;Yoon, Young-Jooh
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.91-99
    • /
    • 2000
  • This study was done to identify the changes of bite force and occlusal contact between before and after stabilization splint therapy. 16 female patients, accepted for orthodontic treatment at the Department of Orthodontics, College of Dentistry, Chosun University, were selected as the sample of this investigation. For comparisons, the samples of 16 were divided into just before stabilization splint, 1 month after stabilization splint, 2 months after stabilization splint, and 3 months after stabilization splint and used the T-scan system to identify the bite force and occlusal contact changes for each group. Statistical analysis of the data was carried out ANOVA tests, and Turkey tests using $SPSS/PC^+$. The results were as follows : 1. Bite force change from just before treatment to 1 month after stabilization splint therapy was statistical significantly decreased (P<0.05). 2. Bite force changes from 1 to 3 months after stabilization splint therapy showed no statistical significance (p>0.05). 3. The changes of anterior occlusal contacts showed no statistical significance regardless of the wearing periods of stabilization splint (P>0.05). 4. The changes of posterior occlusal contacts from just before treatment to 1 month after stabilization splint therapy was statistical significantly decreased (P<0.05). 5. The changes of posterior occlusal contacts Outing 1 to 3 months after stabilization splint therapy showed no statistical significance (P>0.05). 6. Posterior teeth rather than anterior teeth were more influenced by the changes of the number of occlusal contacts. To sum up above results, we may respect to capturing and stabilizing centric relation Position just 1 month after stabilization splint therapy.

  • PDF

Immunohistochemical Study on the Activation of Cell mediated immunity in Murine Lymph node on Allergic Contact Dermatitis by DNCB -Based on the change of T lymphocytes and Il-2 receptors- (알러지성 접촉피부염 유발 피부 주변 림프절에서의 세포성 면역 활성에 관한 면역조직화학적 연구 - T 림프구와 IL-2 수용기의 분포 변화를 중심으로 -)

  • kim, Jin-Taek;Ahn, Sang-Hyun;Park, In-Sick;Chung, Jae-Man;Kim, Ho-Hyun
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.7 no.1
    • /
    • pp.33-41
    • /
    • 1998
  • Lymph node tissues of BALB/C mouse treated with DNCB were immunohistochemically observed to investigate the activation of cell mediated immunity in lymph node of murine with allergic contact dermatitis. The inguinal region of BALB/C mice were sensitized by one application of $25{\mu}l$ of 5% 2,4-dinitrochlorobenzene(DNCB) onto an abdominal skin and 2 weeks later, the mice were challenged with $4{\mu}l$ of 2.5% DNCB. The inguinal lymph node were obtained at hour 24, 48, and 72 after 2nd DNCB treatment and embedded with paraffin, and then stained by following ABC method that used monoclonal antibody including L3T4(CD4), Ly2(CD8), IL-2R(CD25). The distribution of helper T lymphocytes, cytotoxic T lymphocytes and IL-2 receptors began to increase at hour 24 after after 2nd DNCB treatment and these increase appeared in paracortical area and medullary sinius. These increase were greatest at hour 48. These results indicated that the IL-2 secretion began to increase by activation of helper T lymphocytes in lymph node of DNCB re-exposure area and subsequently to activate suppress T lymphocytes.

  • PDF