• Title/Summary/Keyword: 구획실

Search Result 67, Processing Time 0.025 seconds

Development of Multipoint Simultaneous Full-duplex Team Communication Module for SCBA (SCBA 면체용 다자간 동시 양방향 팀 통신모듈 개발)

  • Kim, Si-Kuk;Choi, Su-Gil;Lim, Woo-Sub;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.165-172
    • /
    • 2019
  • This study presents the design and manufacture of a self-contained breathing apparatus SCBA wireless communication module with a multipoint simultaneous full-duplex communication system to enable communication between team members wearing the SCBA system. It is necessary for fire-fighters to wear the SCBA system during extinguishing and rescue work at the fire site. Evaluation of the team communication module confirmed the feasibility of communication over more than 500 m in the test condition based on the line of sight. By implementing the Ad-hoc function, it was confirmed that the communication distance could be extended to 128 m by automatic routing up to 3 hoc. The vertical distance inside the building for successful communication was up to the 5th floor in the open staircase and up to the 3rd floor in the partitioned staircase. Furthermore, the performance testing of the communication module assuming a fire situation, confirmed that five team members correctly recognized the standard abbreviation of fire and wireless communication without a separate PTT key operation. In addition, the flame resistance was verified by exposing the module to a flame at 950 ± 50 ℃ for 5 s and then immediately extinguishing the flame.

Effects of Ventilation Condition on the Fire Characteristics in Compartment Fires (Part I: Performance Estimation of FDS) (구획화재에서 환기조건의 변화가 화재특성에 미치는 영향(Part I: FDS의 성능평가))

  • Hwang, Cheol-Hong;Park, Chung-Hwa;Ko, Gwon-Hyun;Lock, Andrew
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.131-138
    • /
    • 2010
  • Experimental and numerical studies were conducted to investigate the thermal and chemical characteristics of heptane fires in a full-scale ISO 9705 room. Representative fire conditions were considered for over-ventilated fire (OVF) and under-ventilated fire (UVF). Fuel flow rate and doorway width were changed to create OVF and UVF conditions. Detailed comparisons of temperature and species concentrations between experimental and numerical data were presented in order to validate the predictive performance of FDS (Fire Dynamic Simulator). The OVF and UVF were explicitly characterized with distributions of temperature and product formation measured in the upper layer, as well as combustion efficiency and global equivalence ratio. It was shown that the numerical results provided a quantitatively realistic prediction of the experimental results observed in the OVF conditions. For the UVF, the numerically predicted temperature showed reasonable agreement with the measured temperature. The predicted steady-state volume fractions of $O_2$, $CO_2$, CO and THC also agreed quantitatively with the experimental data. Although there were some limitations to predict accurately the transient behavior in terms of CO production/consumption in the UVF condition, it was concluded that the current FDS was very useful tool to predict the fire characteristics inside the compartment for the OVF and UVF.

Utility of B-type Natriuretic Peptide in Patients with Acute Respiratory Distress Syndrome (급성호흡곤란증후군 환자에 있어서 B-type Natriuretic Peptide의 유용성)

  • Rhee, Chin Kook;Joo, Young Bin;Kim, Seok Chan;Park, Sung Hak;Lee, Sook Young;Koh, Yoon Seok;Kim, Young Kyoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.5
    • /
    • pp.389-397
    • /
    • 2007
  • Background B-type natriuretic peptide (BNP) has been shown to be strong mortality predictors in a wide variety of cardiovascular syndromes. Little is known about BNP in patients with acute respiratory distress syndrome (ARDS). We studied whether BNP can predict mortality in patients with ARDS. Method Echocardiographic study was done to all patients with ARDS, and we excluded patient with low ejection fraction (less than 50%) or showing any features of diastolic dysfunction. 47 patients were enrolled between December, 2003 and February, 2006. Parameters including BNP were obtained within 24h hours at the time of enrollment. Result Mean BNP concentrations and APACHE II scores differed between the survivors and nonsurvivors (BNP, $219.5{\pm}57.7pg/mL$ vs $492.3{\pm}88.8pg/mL$; p=0.013, APACHE II score, $17.4{\pm}1.6$ vs $23.1{\pm}1.3$, p=0.009, respectively). With the use of the threshold value for BNP of 585 pg/mL, the specificity for the prediction of mortality was 94%. The threshold value for APACHE II of 15.5 showed sensitivity of 87%. 'APACHE II + $11{\times}logBNP$' showed sensitivity 63%, and specificity 82%, using threshold value for 46.14. Conclusion BNP concentrations and APCHE II scores were more elevated in nonsurvivors than survivors in patients with ARDS who have normal ejection fraction. BNP can predict mortality. Further study should be done.

3-D Resistivity Imaing of a Large Scale Tumulus (대형 고분에서의 3차원 전기비저항 탐사)

  • Oh, Hyun-Dok;Yi, Myeong-Jong;Kim, Jung-Ho;Shin, Jong-Woo
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.4
    • /
    • pp.316-323
    • /
    • 2011
  • To test the applicability of resistivity survey methods for the archaeological prospection of a large-scale tumulus, a three-dimensional resistivity survey was conducted at the $3^{rd}$ tumulus at Bokam-ri, in Naju city, South Korea. Since accurate topographic relief of the tumulus and electrode locations are required to obtain a high resolution image of the subsurface, electrodes were installed after making grids by threads, which is commonly used in the archaeological investigation. In the data acquisition, data were measured using a 2 m electrode spacing with the line spacing of 1 m and each survey line was shifted 1 m to form an effective grid of 1 m ${\times}$ 1 m. Though the 3-D inversion of data, we could obtain the 3-D image of the tumulus, where we could identify the brilliant signature of buried tombs made of stones. The results were compared with the previous excavation results and we could convince that a 3-D resistivity imaging method is very useful to investigate a large-scale tumulus.

Measurement of the Device Properties of Fixed Temperature Heat Detectors for the Fire Modeling (화재모델링을 위한 정온식 열감지기의 장치물성 측정)

  • Park, Hee-Won;Cho, Jae-Ho;Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Kim, Sung-Chan;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.37-43
    • /
    • 2014
  • The high predictive performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of Performance-Based fire safety Design (PBD). The main objective of the present study is to measure input information in order to predictive the accurate activation time of fixed temperature heat detectors adopted in Fire Dynamics Simulator (FDS) as a representative fire model. To end this, Fire Detector Evaluator (FDE) which could be measured the device properties of detector was used, and the spot-type fixed temperature heat detectors of two thermistor types and one bimetal type were considered as research objectors. Activation temperature and Response Time Index (RTI) of detectors required for the fire modeling were measured, and then the RTI was measured for ceiling jet flow and vertical jet flow in consideration of the install location of detectors. The results of fire modeling using measured device properties were compared and validated with the experimental results of full-scale compartment fires. It was confirmed that, in result, the numerically predicted activation time of detector showed reasonable agreement with the measured activation time.

8 Cases of Partial Laryngectomy (최근 경험한 후두부분절제술 8예)

  • 유홍균;김명진;이상학;신홍수
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1983.05a
    • /
    • pp.14.4-15
    • /
    • 1983
  • The laryngeal carcinoma is the most frequent malignant tumor in the E.N.T. field. In the surgical treatment of laryngeal carcinoma, in 1873, Billroth performed the first total laryngectomy, and in 1863, H. B. Sands performed the first partial laryngectomy. Recently general advances (antibiotic therapy, blood trasfusion, and safer anesthesia) result in the improvement of postoperative prognosis. Because the laryngeal lymphatic system has the characteristic compartmentation, this serves the anatomic basis for performing the partial laryngectomy. Although the indications of partial laryngectomy are different from that of total laryngectomy, the partial laryngectomy has the advantage of not only removal of all malignant disease, but also maximum preservation of respiratory, phonatory, and sphincteric function of the larynx. In the latest, surgical treatment decreased the frequency of recurrence, and also increased the 5 year survival rate with combination of the chemotherapy and radiation therapy. The authors have experienced 8 cases of partial laryngectomy for laryngeal carcinoma at the department of otolaryngology, Korea University Hospital from 1980 to 1982. Among the total 8 cases, 2 cases were involved only in the epiglottis, 2 cases in the anterior 1/3 of both vocal cords with ant. comissure, 2 cases in the middle 1/3 of Lt. vocal cord, 1 case in the anterior 1/3 of Rt. vocal cord with ant. comissure, and another 1 case in the Rt. ventrical. So authors report these cases with review of the literature.

  • PDF

Analysis of the Spatial Dose Rates during Dental Panoramic Radiography (치과 파노라마 촬영에서 공간선량률 분석)

  • Ko, Jong-Kyung;Park, Myeong-Hwan;Kim, Yongmin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.509-516
    • /
    • 2016
  • A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a $45^{\circ}$, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is $3,840{\mu}Sv/h$, which is four times higher than the lowest level $778{\mu}Sv/h$. Furthermore, the spatial dose rate was $408{\mu}Sv/h$ on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.