• Title/Summary/Keyword: 구조호흡 장비

Search Result 6, Processing Time 0.021 seconds

A Study on Utilization Improvement of Resuscitation Equipment on Board Ships (선박 내 구조호흡 장비 활용 개선에 관한 연구)

  • Jeong-Hee Hwang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.7
    • /
    • pp.819-827
    • /
    • 2023
  • If respiratory arrest occurs or cardiopulmonary resuscitation (CPR) is performed for a long period on board ships, CPR with rescue breathing (not compression-only CPR) is required. Accordingly, ships must have resuscitation equipment for oxygen supply, and seafarers must have the maritime competence to use it. This study aimed to analyze the placement status of resuscitation equipment on ships and seafarers' intention to use them in order to increase the usability of resuscitation equipment on board ships and propose improvement measures. The study was conducted from February 2, 2023, to April 21, 2023, and a total of 340 seafarers were surveyed. The data were analyzed by frequency, percentage, and chi-square test using SPSS WIN 23.0. The results showed that the checking of resuscitation equipment was high among seafarers in the positions of officer, captain, deck department personnel, and ocean-going personnel. The intention of seafarers to use resuscitation equipment was low, and the main barrier was the lack of knowledge on how to use. Among the general characteristics of the study participants, those whose rank was that of officer or captain, whose working department was the deck, voyage who were ocean-going, and who managed a gross tonnage of 20,000 tons or more had a high intention to use resuscitation equipment. Participants who knew the necessity of rescue breathing and had received practice and equipment-based training were active in using resuscitation equipment. Therefore, a system should be developed so that all ships can be equipped with resuscitation equipment, and an environment must be created to increase accessibility to resuscitation equipment on board ships. In addition, an education system based on practical and resuscitation equipment training must be established to ensure that seafarers have maritime competence.

Evaluation on th e Wear Fit and Activity of Emergency Escape Breathing Devices for Ship Accidents (선박사고용 호흡구난장비의 착용성 및 활동성 평가 연구)

  • Noh, Jae-Hyeon;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.79-84
    • /
    • 2019
  • The use of emergency escape breathing devices (EEBD) is strongly required to protect against toxic gas or flooding caused by ship fires or accidents. Recently developed domestic EEBD products only satisfy the basic performance requirements, but no wear fit and activity performance evaluation has been done for real usage. In this study, the global level test requirements for wear comfort and activity of EEBDs were developed and the open and closed type of domestic EEBD products were evaluated. Poor visibility, longer wear time, breathing resistance, and hose obstruction in an open type and canister obstruction, weight unbalance, and an invisible black breathing bag in the closed type EEBD were estimated to be the main problems that need to be improved.

O2 plasma를 이용한 Flexible ZnO nanogenerator 특성 향상 연구

  • Gang, Mul-Gyeol;Park, Seong-Hwak;Ju, Byeong-Gwon;Lee, Cheol-Seung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.283.1-283.1
    • /
    • 2013
  • ZnO nanowire를 기반으로 하는 nanogenerator는 미세한 움직임을 전기 에너지로 변환 시키는 압전 에너지 하베스팅 기술로 기존 에너지 하베스터와 비교하여 사용환경의 제약이 적고, 소형화가 가능한 장점으로 주목을 받고 있다. 특히 혈류, 심장박동, 호흡 등 인체 활동 에너지를 이용한 발전 소자 등의 활용이 가능하여 활발한 연구가 진행되고 있다. 하지만, 최근 발표된 film like Vertical 구조의 nanogenerator는 nanowire의 구조 취약성으로 인해 내구성이 좋지 못한 단점이 있다. 또한 ZnO nanowire의 내부 O2 결함 및 표면 OH-기의 흡착에 의한 특성 저하가 나타난다. 본 연구에서는 nanogenerator의 내구성을 향상시키기 위해 capping layer로 실리콘 계 유무기 하이브리드를 적용하여 코팅 물질 및 코팅 방법을 최적화 하였으며 상부 전극을 CNT-Ag nanowire 소재로 대체하여 유연기판에 대응코자 하였다. 또한 APP(Atmosphere Pressure Plasma)와 ICP(Inductively Coupled Plasma)장비를 사용하여 ZnO nanowire를 표면처리하였고, 각각의 플라즈마 표면처리의 영향에 대해 조사하였다. XPS를 통하여 OH-기의 제거 유무를 확인하였으며, 소자의 발전 특성의 향상을 확인 하였다.

  • PDF

Multimodality and Application Software (다중영상기기의 응용 소프트웨어)

  • Im, Ki-Chun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.153-163
    • /
    • 2008
  • Medical imaging modalities to image either anatomical structure or functional processes have developed along somewhat independent paths. Functional images with single photon emission computed tomography (SPECT) and positron emission tomography (PET) are playing an increasingly important role in the diagnosis and staging of malignant disease, image-guided therapy planning, and treatment monitoring. SPECT and PET complement the more conventional anatomic imaging modalities of computed tomography (CT) and magnetic resonance (MR) imaging. When the functional imaging modality was combined with the anatomic imaging modality, the multimodality can help both identify and localize functional abnormalities. Combining PET with a high-resolution anatomical imaging modality such as CT can resolve the localization issue as long as the images from the two modalities are accurately coregistered. Software-based registration techniques have difficulty accounting for differences in patient positioning and involuntary movement of internal organs, often necessitating labor-intensive nonlinear mapping that may not converge to a satisfactory result. These challenges have recently been addressed by the introduction of the combined PET/CT scanner and SPECT/CT scanner, a hardware-oriented approach to image fusion. Combined PET/CT and SPECT/CT devices are playing an increasingly important role in the diagnosis and staging of human disease. The paper will review the development of multi modality instrumentations for clinical use from conception to present-day technology and the application software.

Effect of Mask Wearing and Type on Cardiopulmonary Resuscitation Accuracy, Fatigue and Physiological Changes

  • Sung-Hwan Bang;Hyo-Suk Song;Gyu-Sik Shim;Hee-Jeong Ahn
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.7
    • /
    • pp.113-120
    • /
    • 2023
  • The purpose of this study was the accuracy of cardiac compression, fatigue, and physiological changes of the rescuer for different mask type in cardiopulmonary resuscitation(CPR). Data collection was from 9 to 12 May 2022, the participants were a total of 24 paramedic students with a BLS provider at D University. The students participated in an experiment in which 12 students each wore a surgical mask (Dental mask) and a fine particle 94% blocking mask (KF94 mask) and performed CPR for 2 minutes over a total of 7 times. As a result of the study, in the analysis of the quality of the rescuer's chest compression according to the type of mask, there was a significant difference in the compression speed (F=24.91, p<.001) and bad compression hand position (F=14.54, p=.024) in the group wearing the KF94, Fatigue showed significant differences in both the Dental mask group (F=51.16, p<.001) and the KF94 mask group (F=63.49, p<.001). Among the physiological changes, heart rate showed a significant difference between the Dental mask group (F=34.79, p<.001) and the KF94 mask group (F=35.55, p<.001), and the respiratory rate showed a significant difference between the Dental mask group (F=25.02, p=.001) and the KF94 mask group(F=23.02, p=.002). Therefore, in order to improve the quality of efficient chest compression and reduce the fatigue and physiological changes of rescuers, it will be necessary for rescuers to wear suitable personal protective equipment.

Comparison of Ventilation Effects by Mask Type for Proper Health Care of Respiratory Emergency Patients (호흡응급환자의 적절한 헬스케어를 위한 마스크 유형별 환기효과 비교)

  • Kim, Tae-Hyun;Park, Si-Eun
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.7
    • /
    • pp.477-485
    • /
    • 2020
  • This study is a random allocation similar experimental study to compare and analyze the difference in BVM (Bag-Valve-Mask) ventilation volume according to the characteristics of the rescuer's hand and the type of mask using a standardized mannequin. To this end, the Basic Life Resuscitation Education Center of D University in gwangju. Recruiting 39 students who have completed the basic resuscitation course for emergency medical personnel and the Korean-style specialized cardiac rescue course, In addition to measuring the physical characteristics of the hand, the average amount of ventilation per minute using a bag-mask was measured and analyzed. As a result, the type of mask that was not most affected by the characteristics of the hand and provided adequate Minute Ventilation was the soft type (tube, silicone) mask. On the other hard (tube, silicone) masks were found to be unsuitable for general use as they were greatly affected by the characteristics of workers' hands. COVID-19 is currently increasing the risk of transmission to paramedics and patients. Considering this situation, the universal use of a semi-permanent hard-type mask, which is disadvantageous not only for preventing infection but also for proper ventilation, should be avoided. In addition to the ease of use, it should be actively utilized in the field by supplying a soft type mask that can provide stable ventilation even with 'predominance recognition' and proper ventilation.