• Title/Summary/Keyword: 구조적 붕괴

Search Result 646, Processing Time 0.106 seconds

강교량 용접구조의 피로강도 및 응급보수효과에 관한 연구

  • 장동일;김학수;이명구;홍성욱;송창희
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.11a
    • /
    • pp.283-288
    • /
    • 1997
  • 도로와 철도에서 사용되는 강교량에는 최근 차량의 중량화 등에 의해 피로손상이 발생되고 있으며, 이러한 피로손상은 성수대교 붕괴사고나 당산철교 철거등에서와 같이 주로 구조물의 공용중에 발생되기 때문에 이로 인한 사회적$\cdot$경제적 손실은 실로 막대하다. (중략)

  • PDF

A Study on the Verification of water level criteria for forecasting system of reservoir failure (저수지 붕괴예보 시스템의 수위기준 검증 연구)

  • Lee, Baeg;Choi, Byounghan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.51-55
    • /
    • 2019
  • The loss of safety for reservoirs brought about by climate change and facility aging leads to reservoir failures, which results in the loss of lives and property damage in downstream areas. Therefore, it is necessary to provide a Reservoir Failure Forecasting System for downstream residents to detect the early signs of failure (with sensors) in real-time and perform safety management to prevent and minimize possible damage. For the verification of established water level management criteria, 10 water level data up to reservoir capacity was selected. Weight factor and trend line were applied to dramatic increase section of water level in the 1 year period data. The results shows that water level criteria based on three even parts shows less than 7% of standard deviation and it is appropriate to verify management criteria.

Analysis of Influence for Breach Flow According to Asymmetry of Breach Cross-section (제방붕괴 형상의 비대칭성에 따른 붕괴흐름의 영향 분석)

  • Kim, Sooyoung;Choi, Seo-hye;Lee, Seung Oh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.557-565
    • /
    • 2016
  • The risk of collapse in hydraulic structures has become more elevated, due to the increased probability and scale of flooding caused by global warming and the resulting abnormal climatic conditions. When a levee, a typical hydraulic structure, breaks, an enormous breach flow pours into the floodplain and much flood damage then occurs. It is important to accurately calculate the breach discharge in order to predict this damage. In this study, the variation of the breach discharge with the asymmetry in the cross-section of the levee breach was analyzed. Through hydraulic experiments, the cross-section of the breach was analyzed during the collapse using the BASD (Bilateral ASymmetry Degree), which was developed to measure the degree of asymmetry. The relationship of the breach discharge was identified using the BASD. Additionally, the variation of the breach flow measured by the BASD was investigated through a 3-D numerical analysis under the same flow conditions as those in the experiment. It was found that the assumption of a rectangular breach cross-section, which is generally used for the estimation of the inundation area, can cause the breach discharge to be overestimated. According to the BASD, the breach flow is decreased by the interference effect in the breach section of the levee. If the breach flow is calculated while considering the BASD in the numerical analysis of the flooding, it is expected that the predicted inundation area can be estimated accurately.

Evaluation on Hydrological Safety of Large Dams in Korea (국내 대댐의 수문학적 안전성 평가)

  • Kim, Kyung-Duk;Kwon, Ji-Hye;Ryu, Keun-Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.173-177
    • /
    • 2005
  • 2005년 2월 10일 파키스탄 남서부 발루치스탄 주에서 샤키도르 댐붕괴 사고로 1800명 이상의 사망자와 실종자가 발생하였고 댐이 무너지면서 1만 8,000채의 가옥이 부서지는 피해가 발생하였다. 이러한 홍수는 2월 3일부터 10일까지 일주일간 폭우가 내리면서 발생하였다. 과연, 남의 나라의 문제이고 우리나라의 경우와는 상관이 없는 것일까? 우리나라의 경우 한국시설안전기술공단(이하 공단)에서는 1996년부터 현재까지 1종 댐 시설물에 대한 정밀안전진단을 실시한 결과 대부분 수문학적 안전성이 매우 낮은 것으로 나타나, 그에 따른 구조적인 홍수대책방안으로 댐 증고, 보조여수로 신설, 여수로 확장 및 상류에 홍수조절용 댐 신설 등의 대책을 제시하고 있다. 그러나 이러한 구조적인 대책은 경제성, 시공성, 그리고 환경적인 측면에서 현실적으로 어려운 점이 많은 실정이다. 따라서, 우리나라의 경우에도 기상이변에 따른 댐붕괴 가능성이 상존하므로 이러한 어려운 문제점을 극복할 수 있는 충분한 대책을 마련해야 할 것이다. 본 연구에서는 금번 파키스탄에서 발생한 호우와 같이 장시간 발생한 호우사상(2002년 태풍 간무리)의 경우에 대하여 한강유역 댐들의 수문학적 안전성을 불리한 조건으로 모의하여 댐안전성을 평가하였다. 또한, 공단에서 수리, 수문학적 안전성을 평가한 1종 댐들의 설계보고서, 정밀안전진단 등 준공 후 현재까지 시행된 용역결과들을 토대로 수문학적 안전성 평가 기준에 대한 변화양상을 비교$\cdot$분석하였다.

  • PDF

Progressive Collapse Analysis of Reinforced Concrete Core Structure Subjected to Internal Blast Loading (내부 폭발하중을 받는 철근콘크리트 코어의 연쇄붕괴 해석)

  • Kim, Han-Soo;Ahn, Jae-Gyun;Ahn, Hyo-Seong
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.715-722
    • /
    • 2014
  • In this paper, internal blast effect of reinforced concrete core structure were investigated using Ansys Autodyn, which is a specialized hydrocode for the analysis of explosion and impact. It is expected that internal blast case can give additional damage to the structure because it causes rebound of blast loads. Therefore, in this paper, the hazard of internal blast effect is demonstrated using UFC 3-340-02 criteria. In addition, analysis result of Autodyn, experimental result regarding rebound of blast load, and example of UFC 340-02 are compared to verify that Autodyn can analyze internal blast effect properly. Furthermore, progressive collapse mechanism of core structure which is one of the most important parts in high rise buildings is also analyzed using Autodyn. When internal blasts are loaded to core structure, the core structure is mostly damaged on its corner and front part of core wall from explosives. Therefore, if the damaged parts of core wall are demolished, progressive collapse of the core structure can be initiated.

Collapse Capacity Evaluation of Steel Intermediate Moment Frames Using Incremental Dynamic Analysis (비선형 증분동적해석을 통한 철골 중간모멘트 골조의 붕괴성능 평가)

  • Shin, Dong-Hyeon;Kim, Hyung-Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.9-20
    • /
    • 2014
  • Steel intermediate moment frames (IMFs) have been generally used as seismic load resisting systems (SLRSs) of a building to provide resistances against strong ground shaking. However, most of low and mid-rise steel buildings in Korea were constructed during pre-seismic code era or before the introduction of well-organized current seismic codes. It has been recognized that the seismic performance of these steel IMFs is still questionable. In order to respond to such a question, this study quantitatively investigates the seismic capacities of steel IMFs. Prototype models are built according to the number of stories, the levels of elastic seismic design base shear and the ductilities of structural components. Also, the other prototype models employing hysteretic energy dissipating devices (HEDDs) are considered. The collapse mechanism and the seismic performance of the prototype models are then described based on the results obtained from nonlinear-static and incremental-dynamic analyses. The seismic performance of the prototype models is assessed from collapse margin ratio (CMR) and collapse probability. From the assessment, the prototype model representing new steel IMFs has enough seismic capacities while, the prototype models representing existing steel IMFs provide higher collapse probabilities. From the analytic results of the prototype models retrofitted with HEDDs, the HEDDs enhance the seismic performance and collapse capacity of the existing steel IMFs. This is due to the energy dissipating capacity of the HEDDs and the redistribution of plastic hinges.

Grounded electrical-source airborne transient electromagnetic (GREATEM) survey of Mount Bandai, north-eastern Japan (접지된 전기 송신원을 이용한 일본 북동부 만다이 산에서의 시간영역 항공 전자탐사)

  • Mogi, Toru;Kusunoki, Ken'ichirou;Kaieda, Hideshi;Ito, Hisatoshi;Jomori, Akira;Jomori, Nobuhide;Yuuki, Youichi
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Airborne electromagnetics (AEM) is a useful tool for investigating volcanic structures because it can survey large and inaccessible areas. Disadvantages include lower accuracy and limited depth of investigation. The Grounded Electrical Source Airborne Transient Electromagnetic(GREATEM)survey system was developed to increase the depth of investigation possible using AEM. The method was tested in a survey at Mount Bandai in north-eastern Japan. Mount Bandai is an andesitic stratovolcano that rises 1819m above sea level. An eruption in July 1888 left a hoof-shaped collapsed wall in its northern crater and avalanche debris at its base. Previous surveys of Mount Bandai allow for comparisons of data on its structure and collapse mechanism as obtained by GREATEM and other geophysical methods. The results show resistive structures in recent volcanic cones and conductive structures in the collapsed-crater area. Conductive areas around the collapsed wall correspond to an alteration zone resulting from hydrothermal activity, supporting the contention that a major cause of the collapse associated with the 1888 eruption was hydrothermal alteration that structurally weakened the interior of the volcanic edifice.

Analytical Study on Effect of Floor Slab for Progressive Collapse Resistant Capacity of Steel Moment Frames (철골모멘트골조의 연쇄붕괴저항성능에 대한 바닥슬래브의 효과에 관한 해석적 연구)

  • Kim, Seonwoong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.1
    • /
    • pp.27-35
    • /
    • 2014
  • In this study, an improved energy-based nonlinear static analysis method are proposed to be used for more accurate evaluation of progressive collapse potential of steel moment frames by reflecting the contribution of a double-span floor slab. To this end, the behavior of the double-span floor slab was first investigated by performing material and geometric nonlinear finite element analysis. A simplified energy-absorbed analytical model by idealizing the deformed shape of the double-span floor slab was developed. It is shown that the proposed model can easily be utilized for modeling the axial tensile force and strain energy response of the double-span floor slab under the column-removal scenario.

Fly ash로부터 합성한 Swelling Mica의 양이온 교환 특성

  • 우영안;최충렬;이동훈;김장억;최정
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11b
    • /
    • pp.315-318
    • /
    • 2003
  • 본 연구에서는 NaCl 용응법에 의해 fly ash로부터 합성된 swelling mica의 다양한 이온의 교환특성과 이온교환이 결정구조에 미치는 영향을 규명함으로서 swelling mica에 의한 유해 방사능 물질 및 중금속의 효과적인 제거제로서의 활용 가능성을 조사하고자 하였다. 1가 양이온이 흡착된 FA-swelling mica의 $d_{001}$/ peak의 강도는 흡착된 이온의 직경이 클수록 감소하는 경향을 나타내었으나, $d_{001}$/ value는 흡착된 이온의 직경과 뚜렷한 상관관계가 없었다. 또한 FA-swelling mica의 NH4 이온의 흡착량은 133 $cmol^{+}$/kg, K 이온은 127 $cmol^{+}$/kg, Li 이온은 23 $cmol^{+}$/kg으로서 방사성 물질과 중금속 이온에 비해 낮은 경향을 나타내었다. 2가 양이온이 흡착된 FA-swelling mica의 $d_{001}$/ peak 강도와 $d_{001}$/ value는 이온의 직경에 관계없이 비슷한 값을 나타내었으며 1가 양이온의 흡착에 비해 구조적 안정성이 높았다. Sr 및 Ba 이온의 흡착반응은 느리고 지속적으로 일어났으며 Ca와 Mg 같은 2가 양이온에 비해 선택성이 훨씬 높은 것으로 나타났다. 또한 Sr 및 Ba 이온과 같이 직경이 큰 방사성 원소들은 swelling mica의 층간에 흡착되어 결정구조가 부분적으로 붕괴됨으로서 이온을 비가역적으로 고정하는 특성을 나타내었다. Zn, Cu, Cd 및 Pb 등의 중금속 이온이 흡착된 FA-swelling mica의 $d_{001}$/ value는 12.70~12.80$\AA$으로서 매우 일정하였으며, 이온 흡착에 의한 층간 팽창정도는 이온의 크기뿐만 아니라 수화정도에 따라 상이하였다. FA-swelling mica의 중금속 이온의 흡착은 층간 붕괴에 의해 일어나는 것으로 판단되며, 선택성과 흡착능력은 층간 붕괴속도와 비례하는 경향을 나타내었다. 또한 FA-swelling mica의 중금속 이온의 선택성은 Pb>Cu>Cd$\geq$Zn 순으로 나타났다.

  • PDF

Sensitivity Analysis of Model Parameters used in a Coupled Dam-Break/FLO-2D Model to Simulate Flood Inundation (FLO-2D에서 댐붕괴 모형 매개변수의 침수 범위 민감도 분석)

  • Lee, Khil-Ha;Son, Myung-Ho;Kim, Sung-Wook;Yu, Soonyoung;Cho, Jin-Woo;Kim, Jin-Man;Jung, Jung-Kyu
    • The Journal of Engineering Geology
    • /
    • v.24 no.1
    • /
    • pp.53-67
    • /
    • 2014
  • Numerical modeling is commonly used to reproduce the physical phenomena of dam-break and to compile resulting flood hazard maps. The accuracy of a dam-break model depends on the physical structure that describes the volume of storage, breach formation and progress, input variables, and model parameters. Model input and parameters are subjective in that they are prescribed; hence, caution is needed when interpreting the results. This study focuses on three parameters (breach degree ${\theta}$, shape factor P, and collapse rate k) used when the dam-break model is coupled with FLO-2D (a two-dimensional flood simulation model) to estimate flood coverage and depth etc. The results show that the simulation is sensitive to the shape factor P and the collapse rate k but not to the breach degree ${\theta}$. This study will contribute to reducing flood damage from dam-break disasters in the future.