• Title/Summary/Keyword: 구조성능시험

Search Result 1,589, Processing Time 0.028 seconds

Evaluation of Pull-out Performance of Torsion Control Expansion Anchor According to Drill Bit Diameter (드릴비트 직경에 따른 비틀림 제어 확장 앵커의 인발성능 평가)

  • Kyoung-Hun Chae;Tae-Wo Park;Moo-Won Hur;Yeong-Seung An;Ju-Yeon Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.64-70
    • /
    • 2023
  • In this study, reliability tests of torsion control expansion anchors according to drill bit diameters were performed. The standard deviation and coefficient of variation of the anchor were reviewed through the tests for each variable, and the results were compared and evaluated with the standard test results. As a result of the reliability test of the M12 and M16 anchors with 1.04 times the drill bit diameter, they were within 20% of the ultimate tensile load permissible standard coefficient of variation. It was found that the pulling-out performance of the anchor installed in the large hole was sufficiently secured. However, it was found to be about 253% and 210% of the design strength, indicating that the pulling performance of the anchor installed in 1.04 times the drill bit diameter was sufficiently secured. As a result of the reliability test of the M12 and M16 anchors with 1.02 times the drill bit diameter, the value of the coefficient of variation of the ultimate tensile load limit was within 20%, which satisfies the test standard. It was shown to be about 136% and 168% of the design strength, indicating that the pulling-out performance of the anchor installed in 1.02 times the drill bit diameter is sufficiently secured.

The Design and Performance test of the Acoustic enclosure for Diesel engine (기관 소음원 차폐장치 설계 및 성능시험)

  • 서종수;전재진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.04a
    • /
    • pp.167-171
    • /
    • 1994
  • 본 연구에서는 차폐구조 내부에 위치한 소음원의 체적이 비교적 큰 근접 음향 차폐구조로 취급하여, 구조 내부의 공간적 음장분포해석(spatial sound distribution analysis)은 하지 않고 단지 소음원의 표면과 차폐 벽면 간의 공기층에 의한 간섭 영향을 고려하면서, 차폐로 인한 음압의 상승(build up)효과를 고려하여, 직육면체의 형상을 가지는 차폐구조에 부착되는 각각의 벽면들의 음향 삽입손실(Insertion Loss, IL) 특성을 전달매트릭스 기법(Transfer Matrix Analysis, TMA)을 이용하여 해석하였으며, 이러한 벽면들에 대한 이론 해석의 결과로 제작된 벽면들의 음향차폐특성을 시험을 통해 나타내었다.

  • PDF

Development of Ka-band Transponder for Communications & Broadcasting Satellite (통신방송위성 Ka 대역 중계기 개발)

  • 신동환;이호재;박종흥;우형제;이성팔
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.330-333
    • /
    • 2003
  • 본 논문에서는 조립/제작, 시험과정을 통하여 개발된 통신방송위성용 Ka 대역 통신위성 중계기의 구조 및 성능에 대하여 기술한다. 개발된 중계기는 전체 400MHz 대역 내에 100 MHz 대역폭을 갖는 3 개의 통신채널을 수용하여 광대역 멀티미디어 서비스를 지원할 수 있도록 설계되었으며 국내 기술로 제작되어 우주인증을 거친 IFA, RxDC, IMUX, CH-AMP 등의 부품으로 구성되어 있다. 중계기에 대한 성능시험은 EGSE를 이용해 자동으로 수행되었으며, 성능시험결과 대부분의 성능 항목이 요구사항과 부합됨을 확인하였다. 제작된 Ka 대역 중계기에 적용된 위성 중계기 및 부품의 제작 및 시험 기술은 향후 통신해양기상위성에 탑재될 중계기의 개발에 직접 응용이 가능하다.

  • PDF

차단기의 해석기술

  • 신영준;박경엽;송기동;송원표;민석원
    • 전기의세계
    • /
    • v.45 no.2
    • /
    • pp.17-24
    • /
    • 1996
  • 차단기의 개발과정은 크게 모의시험, 설계 및 제작, 성능시험 3가지로 나누어 볼 수 있다.이 중에서 모의 시험은 일반적으로 해석기술에 의해 주로 이루어지며, 차단기에 적용되는 해석기술은 1) 차단부 전계해석 2) 차단부 냉가스 유동해석 3) 차단부 열가스 유동해석(차단성능해석) 4) 차단기 동작특성해석 5) 차단기 응력해석 및 구조해석으로 대별할 수 있다. 상기의 해석기술은 적용하는 해석방법에 따라 다소 차이가 있지만, 1992년부터 당 연구팀이 개발중인 800kV 40kA 4000A 차단부를 개발하는 과정에 적용한 해석수법을 중심으로 살펴보기로 한다.

  • PDF

A Study on the Performance Comparison of S2 type Bridge Rails (S2급 교량용 방호울타리의 성능비교 연구 (F형 콘크리트와 철재 교량용 방호울타리를 중심으로))

  • 정봉조;주재웅;이성관;장명순
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.2
    • /
    • pp.117-124
    • /
    • 2002
  • 새로 개발한 철재 교량용 방호울타리는 기존 시설에 비해 충격흡수기능과 조망권 확보, 융설작업, 유지보수가 용이하도록 설계되었다. 본 연구는 새로 개발한 철재 교량용 방호울타리를 건설교통부의 $\ulcorner$도로안전시설 설치 및 관리지침 - 교량용 방호울타리 편. 1999$\lrcorner$ 의 설계기준에 따라 기존 고속도로에 사용하고 있는 F형 콘크리트 교량용 방호울타리와 성능비교를 통해 평가하고자 하였다. 비교평가는 S2급 교량용 방호울타리의 시험기준으로 실시하였으며 결과는 다음과 같이 나타났다. 첫째, 소형승용차를 대상으로 한 운전자의 안전도 평가에서는 두가지 시설 모두 강도성능, 충돌 후 차량 안전성능 구성 부재 비산 억제 성능 등 세 가지 기준을 만족하였으나, 가속도 기준에 있어서는 철재 교량용 방호울타리는 기준인 20g 이하인 18.2605g로 나타나 안전기준을 만족하였고, F형 콘크리트 교량용 방호울타리는 20.1791g로 나타나 기준을 약간 상회하는 것으로 나타났으나 안전기준의 범위에 있는 것으로 평가하였다. 둘째. 대형차량을 대상으로 한 방호울타리의 구조적 안정성 평가에 있어서는 F형과 철재 교량용 방호울타리 모두 평가기준에 적합한 것으로 나타났다. 새로 개발한 철재 교량용 방호울타리는 국내 최초로 모의충돌시험과 실물차량 충돌시험을 통해 개발하였다는 의의를 가지고 있으며 성능측면에서도 기존의 시설에 비해 충분히 안전하다는 것을 증명하였다. 그러나 측정시설의 미비로 충돌후의 차량의 이탈속도나 이탈각도에 대하여 만족할 만한 수준의 결과를 제시하지는 못하였다.

Development of Vermiculite Board to Secure the Fire Resistance Performance of Light-Frame Wood Structural Wall (경골목구조 벽체의 내화성능확보를 위한 질석보드 개발)

  • Yoo, Seok Hyung;Cheong, Chang Heon
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.40-45
    • /
    • 2018
  • It is considered that vermiculite as an inorganic material is highly effective when it is used as a building finishing material because it is eco-friendly. Vermiculite has excellent properties such as fire resistance, heat insulation, sound absorption as well as prevention of condensation, deodorization and aesthetics. In this study, we developed a finishing board with vermiculite as its main material and mixed with mineral loose wool (VB-L) or mineral powder (VB-P), and conducted fireproof test and insulation test. In addition, fire resistance tests were carried out by applying the two developed vermiculite boards as finishing materials for the standard wall details of light frame wood structures (KS F 1611-1). As a result of the fire resistance test, the VB-L specimen showed better fire resistance than the VB-P specimen. Both vermiculite boards showed sufficient fire resistance performance of 2 hours for a thickness of 30 mm.

A Study on Assessment of Penetration Seals Performance of Nuclear Power Plants (원자력발전소 관통부 충전구조의 내화성능평가에 관한 연구)

  • Cho Hong-Seok;Park Jun-Hyen;Son Bong-Sae;Im Jung-Soon
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.93-102
    • /
    • 2004
  • The function of fire barrier penetration sealing is highly important to confine a fire propagation a fire severity within a fire area where the fire started. Especially for the penetration seals at the nuclear power plants with the long-term operated history, it is needed to make it clear that the conformance to the sealing requirements has been proven to guarantee the fire-resistive performance of fire barrier penetration parts. If there are any parts of fire barrier penetration sealing which can not meet the required rating for the fire endurance performance, the relevant parts must be modified to meet regulatory requirements. At this paper, the engineering analysis methodology was established to approximate the fire endurance rating for the fire barrier penetration seals. With this study, the method of engineering analysis to decide fire endurance rating for the fire barrier penetration seals was established and this way can be utilized to check the performance of the fire rating for the penetration seal at the domestic nuclear power plants.

Impact and Bending Characteristics of Dual Band Composite Antennas (복합 구조 이중대역 안테나의 충격 및 굽힘 특성)

  • Shin, Dong-Sik;Kim, Jin-Yul;Park, Wee-Sang;Hwang, Woon-Bong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.2
    • /
    • pp.35-40
    • /
    • 2011
  • We have studied the impact and bending characteristics of a dual band antenna (1.575, 2.645 GHz) with composite sandwich construction. Mechanical performance of the antenna can be improved by reinforcing the antenna by sandwiching the planar antenna with layers of carbon fiber-reinforced plastic(CFRP) and glass fiber-reinforced plastic(GFRP) using an adhesive film. According to the ASTM D7137, ASTM C393 and MIL-STD401B, impact and bending test were performed and the S-parameters and gains of the antenna were measured in order to verify electrical and mechanical performance. The maximum contact load and the bending load of the antenna are 4 kN and 400 N and gains of the antenna are 6 dBi and 4.6 dBi in the GPS and DMB bands, respectively. The proposed antenna structure can be applied to surfaces of vehicles.

Test research of Structural Safety for Steel Wire-Integrated Deck Plate System (철선일체형 데크 플레이트 구조성능평가를 위한 실험적 연구)

  • Lee, Yong-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.220-228
    • /
    • 2010
  • A steel wire-integrated deck plate that welds integrated triangle truss steel wires on a galvanized steel sheet is developed to reduce construction costs of a slab or formwork such as shores and supports, and it is already widely applied in many construction fields. This study selected upper and lower steel wires, lattice steel wires, span, and cutting methods of ends as variables, and conducted an experimental test by manufacturing a total of 32 full scale test bodies. According to the result, changes in final destruction types of the test bodies and cutting methods of ends didn't affect structural performance of test bodies, and for a 3.2m-span test body, there was no big problems in using ${\Phi}4.5$ of lattice steel wires.

Experimental Fatigue Characteristics of Composite Bridge Deck of Hollow Section (중공단면 복합소재 교량 바닥판의 실험적 피로특성 분석)

  • Lee, Sung-Woo;Hong, Kee-Jeung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.4 s.74
    • /
    • pp.337-345
    • /
    • 2006
  • In this study, to evaluate fatigue characteristics of developed composite bridge deck, compression fatigue test at girder support and flexural fatigue test for the 2.8m-long flexural test model were carried out. For the test specimen, DB 24 truck load was applied up to 2,000,000 cycles. In the compression fatigue test, behavior at deck tube and its bonded connection were evaluated. In the flexural fatigue test, deck behavior at mid-span and girder connection were evaluated.