• Title/Summary/Keyword: 구조물 변위

Search Result 1,355, Processing Time 0.027 seconds

An Experimental Study on the Reinforcement Effect of Installed Micropiles in the Surround of Footing on Dense Sand (조밀한 모래지반의 기초 인접에 설치된 마이크로파일 보강효과에 관한 실험적 연구)

  • Lee Tae-Hyung;Im Jong-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.5
    • /
    • pp.69-81
    • /
    • 2006
  • The micropile, which is a kind of the in-situ manufactured pile with small diameter of $150\sim300mm$, is constructed by installing a steel bar or pipe and injecting grout into a borehole. The application fields of micropile are being gradually expanded in a limited space of down-town area, because the micropile has various advantages with low vibration and noise in method and compact size in machine, etc. Mostly, the micropile has been applied to secure the safety of structures, depending on the increment of bearing capacity and the restraint of displacement. The micropile is expected to be used in various fields due to its effectiveness and potentiality in the future. The model test, focused on the interaction between micropile and soil in this study, was carried out. The micropile is installed in a soil adjacent to footing (concept of 'soil reinforcement'). With the test results and soil deformation analysis, the reinforcement effect (relating to bearing capacity and settlement) was analysed in a qualitative and quantitative manner, respectively. Consequently, it is expected that we nay demonstrate the improvement of an efficiency and application in the design and construction of micropile.

Punching Shear Strength of RC Slabs by Simple Truss Model (단순 트러스 모델에 의한 철근콘크리트 교량 바닥판의 펀칭전단강도)

  • Lee, Yongwoo;Hwang, Hoonhee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.187-196
    • /
    • 2008
  • The punching shear strength of RC slabs is estimated analytically by the simple truss model. To avoid intrinsic difficulties in punching shear analysis of reinforced concrete slabs, the slabs were divided into three sub-structures as the punching cone and the remaining parts. The strength of the punching cone was evaluated by the stiffness of inclined strut. The stiffness of springs which control lateral displacement of the roller supports consists of the steel reinforcement which passed through the punching cone. Initial angle of struts was determined by curve fitting method of the experimental data with variable reinforcement ratio in order to compensate for uncertainties in the slab's punching shear, the simplification errors and the stiffness of the remaining sub-structures. The validity of computed punching shear strength by simple truss model was shown by comparing with experimental results. The punching shear strength, which was determined by snap-through critical load of shallow truss, can be used effectively to examine punching shear strength of RC slabs.

Stability Test of Riprap Based Flexible Revetment Method by Real-scale Hydraulic Experiment (사석기반 연성호안공법의 실규모 수리 안정성 실험)

  • Kim, Sung Jung;Kim, Myoung Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.250-250
    • /
    • 2022
  • 호안은 유수로부터 제방과 하안을 보호하는 구조물로 태풍 또는 집중호우로 인한 홍수로부터의 안정성이 확보되어야 한다. 일반적으로 호안공법은 강성호안과 연성호안으로 구분되는데 호안재료로써의 기준과 설치 및 유지상태 기준에 따라 다르게 해석되고 있는 것이 현실이다. 최근에는 호안공법의 재료의 연결성에 따라 강성호안과 연성호안을 구분짓는다고 언급되기도 한다. 본 연구에서는 친환경 석재를 사용하고 재료와 기반재의 체결을 통해 연결성을 확보하고 굴요성을 갖게 하는 연성호안공법에 대해 실규모 실험을 계획하였다. 수리 안정성 검토를 위한 실규모 실험은 안동 하천실험센터에서 수행하였다. 실험에 사용된 수로는 8°의 경사를 갖는 급경사수로에서 수행하였으며, 수로의 제원은 폭 3m, 길이 30m 의 직사각형 형태의 직선수로로 이루어져 있다. 시험체는 실규모로 제작되며 실험수로 내 2m × 10m 의 제원을 갖는 공간에 제작된 호안공을 크레인을 이용하여 실험수로에 설치하였다. 수리 안정성 실험은 실험대상유량을 단계별로 나누어 점차적으로 증가시키고, 시험체의 이탈, 파괴 등의 큰 변화가 발생(미국 재료시험학회 연결형 콘크리트 블록 시험방법, ASTM D 7277)하였을 경우 실험을 종료하도록 계획하였다. 수리량 측정항목은 유속, 수위 등이 있으며, 호안공 의 물리적 변화는 3D스캐너를 이용하여 설치 전·후 변위를 검토하였다. 총 3회에 걸쳐 실험을 수행하였으며 실험조건에 따라 일부 시험체에서 돌출 또는 침하현상이 발생하기도 하였으나 호안의 손상이나 이탈, 연성기반재의 찢어짐 등 안정정을 저해하는 호안공 시험체의 변화는 발생하지 않는 것으로 확인되었다. 실험결과 실험수로에서 발생가능한 최대유량인 4.6cms 조건에서 본 호안공법은 약 337.7N/m2 의 소류력을 확보하는 것으로 확인되었다.

  • PDF

A Study of Strength Reduction Factor Preparation for Circular Concrete Columns confined by Carbon Sheet Tube (카본시트튜브로 구속된 원형 콘크리트 기둥의 강도감소계수 제안에 관한 연구)

  • Lee, Kyoung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.106-112
    • /
    • 2016
  • In this study, circular concrete column specimens confined by carbon sheet tube with different winding angles and different number of carbon sheet plies(3T, 5T and 7T) were tested to propose design equations and a strength reduction factor. Specimens were designed by 300 mm diameter and 600 mm height with $90^{\circ}{\pm}0^{\circ}$, $90^{\circ}{\pm}30^{\circ}$, $90^{\circ}{\pm}45^{\circ}$, $90^{\circ}{\pm}60^{\circ}$, $90^{\circ}{\pm}75^{\circ}$ and $90^{\circ}{\pm}90^{\circ}$ carbon fiber angles. A 10,000 kN UTM was used for compressive strength test of specimens by displacement control method with 0.01 mm/sec velocity. Estimation equations of compressive strength and ultimate strain of circular concrete column specimens confined by carbon sheet tube using a regression analysis and a strength reduction factor to apply ultimate strength design method of concrete were proposed. The strength reduction factor(${\phi}$) of circular concrete columns confined by carbon sheet tube was estimated as 0.64 by the Monte Carlo Analysis Method. Manufacture and construction process have to be perfectly managed by construction managers because the structural capacities of carbon tubes were depends on construction abilities of manufacturing operators.

Structural Behavior of Steel Fiber-Reinforced Concrete Beams with High-Strength Rebar Subjected to Bending (휨을 받는 강섬유 보강 고강도철근 콘크리트 보의 구조 거동)

  • Yang, In-Hwan;Kim, Kyoung-Chul;Joh, Changbin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.93-102
    • /
    • 2016
  • The purpose of this paper is to investigate the flexural behavior of high-strength steel fiber-reinforced concrete beams with compressive strength of 130 MPa. The paper presents experimental research results of steel fiber-reinforced concrete beams with steel fiber content of 1.0% by volume and steel reinforcement ratio of less than 0.02. Both of normal-strength rebar and high-strength rebar were used in the test beams. Modeling as well as compressive and tensile strength test of high-strength steel fiber-reinforced concrete was performed to predict the bending strength of concrete beams. Tension modeling was performed by using inverse analysis in which load-crack mouth opening displacement relationship was considered. The experimental results show that high-strength steel fiber-reinforced concrete beams and the addition of high-strength rebar is in favor of cracking resistance and ductile behavior of beams. For beams reinforced with normal-strength rebar, the ratio of bending strength prediction to the test result ranged from 0.81 to 1.42, whereas for beams reinforced with high-strength rebar, the ratio of bending strength prediction to the test result ranged from 0.92 to 1.07. The comparison of bending strength from numerical analysis with the test results showed a reasonable agreement.

A Dynamic Analysis of PSC Box Bridge Varying Span Lengths for Increased Speeds of KTX (고속철 속도변화에 대한 PSC박스 교량의 경간길이 별 동적해석)

  • Oh, Soon Taek;Lee, Dong Jun;Shim, Young Woo;Yun, Jun Kwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.4
    • /
    • pp.204-211
    • /
    • 2011
  • A dynamic analysis procedure is developed to provide a better estimation of the dynamic responses of bridge during the passage of high speed railway vehicles. Particularly, a three dimensional numerical model including the structural interaction between high speed vehicles, bridges and railway endures to analyse accurately and evaluate with in-depth parametric studies for dynamic responses of various bridge span lengths running KTX railway locomotive up to increasing maximum speed(450km/h). Three dimensional frame element is used to model the simply supported pre-stressed concrete (PSC) box bridges for four span lengths(40~25m). Track irregularity employed as a stationary random process from the given spectral density functions and irregularities of both sides of the track are assumed to have high correlation. The high-speed railway vehicle (KTX) is used as 38-degree of freedom system. Three displacements (Vertical, lateral, and longitudinal) as well as three rotational components (Pitching, rolling, and yawing) are considered in the 38-degree of freedom model. The dynamic amplification factors are evaluated by the developed procedure under various traveling conditions, such as track irregularity camber, train speed and ballast. The dynamic analysis such as Newmark-${\beta}$ and Runge-Kutta methods which are able to analyse considering the dynamic impact factors are compared and contrasted.

Flexural Behavior of High Strength Reinforced Concrete Beams by Replacement Ratios of Recycled Coarse Aggregate (순환굵은골재 치환율에 따른 고강도 철근콘크리트 보의 휨 거동)

  • Lee, Yong-Taeg;Hong, Seung-Uk;Kim, Seung-Hun;Baek, Sang-Ki;Cho, Young-Sang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • Recently, natural aggregate was adequate to supply the demand due to increase of building construction. National pollution induced by construction waste caused by the reconstruction and redevelopment was cited as the major social issues in Korea. Therefore, government are required by law to use the recycled aggregate. In order to consider safety, KS F 2573 recommend that recycled aggregate with below design strength 27MPa and replacement ratio of 30%. This study on flexural behaviors of reinforced concrete beam was conducted and the specimens employed in test were planed with high strength concrete (40, 50 and 60MPa) and recycled aggregate replacement ratio (0, 30, 50, 100%). Although the flexural strength of reinforced concrete beam has trendy to decrease with increase of replacement ratio, it is meet to KCI 2007. The comparison results show that reinforced concrete beam using recycled aggregate can apply as flexural member in building construction.

The Strain of Transverse Steel and Concrete Shear Resistance Degradation after Yielding of Reinforced Concrete Circular Pier (철근콘크리트 원형 교각의 횡방향철근 변형률과 항복이후 콘크리트 전단저항 저감)

  • Ko, Seong Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.147-157
    • /
    • 2018
  • The basis of capacity design has been explicitly or implicitly regulated in most bridge design specifications. It is to guarantee ductile failure of entire bridge system by preventing brittle failure of pier members and any other structural members until the columns provides fully enough plastic rotation capacity. Brittle shear is regarded as a mode of failure that should be avoided in reinforced concrete bridge pier design. To provide ductility behavior of column, the one of important factors is that flexural hinge of column must be detailed to ensure adequate and dependable shear strength and deformation capacity. Eight small scale circular reinforced concrete columns were tested under cyclic lateral load with 4.5 aspect ratio. The test variables are longitudinal steel ratio, transverse steel ratio, and axial load ratio. Eight flexurally dominated columns were tested. In all specimens, initial flexural-shear cracks occurred at 1.5% drift ratio. The multiple flexural-shear crack width and length gradually increased until the final stage. The angles of the major inclined cracks measured from the vertical column axis ranged between 42 and 48 degrees. In particular, this study focused on assessing transverse reinforcement contribution to the column shear strength. Transverse reinforcement contribution measured during test. Each three components of transverse reinforcement contribution, axial force contribution and concrete contribution were investigated and compared. It was assessed that the concrete stresses of all specimen were larger than stress limit of Korea Bridge Design Specifications.

Evaluation of Seismic Behavior for RC Moment Resisting Frame with Masonry Infill Walls (비내력벽을 가진 RC모멘트저항골조의 지진거동 평가)

  • Ko, Hyun;Kim, Hyun-Su;Park, Yong-Koo;Lee, Dong-Guen
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.13-22
    • /
    • 2010
  • Masonry infill walls are frequently used as interior partitions and exterior walls in low- or middle- rise RC buildings. In the design and assessment of buildings, the infill walls are usually treated as non-structural elements and they are ignored in analytical models because they are assumed to be beneficial to the structural responses. Therefore, their influences on the structural response are ignored. In the case of buildings constructed in the USA in highly seismic regions, infill walls have a lower strength and stiffness than the boundary frames or they are separated from the boundary frames. Thus, the previously mentioned assumptions may be reasonable. However, these systems are not usually employed in most other countries. Therefore, the differences in the seismic behaviors of RC buildings with/without masonry infill walls, which are ignored in structural design, need to be investigated. In this study, structural analyses were performed for a masonry infilled low-rise RC moment-resisting frame. The infill walls were modeled as equivalent diagonal struts. The seismic behaviors of the RC moment-resisting frame with/without masonry infill walls were evaluated. From the analytical results, masonry infill walls can increase the global strength and stiffness of a structure. Consequently, the interstory drift ratio will decrease but seismic forces applied to the structure will increase more than the design seismic load because the natural period of the structure decreases. Partial damage of the infill walls by the floor causes vertical irregularity of the strength and stiffness.

Connection Performance of Steel Moment Frame with Out-of-Plane Beam Skew (면외방향 어긋난 보를 갖는 철골모멘트골조의 접합부 성능)

  • Hong, Jong-Kook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.2
    • /
    • pp.84-91
    • /
    • 2022
  • This study investigated the behavior of out-of-plane skewed moment connections that were designed as IMFs, as per the Korean standards. A total of 14 finite element models were constructed with the consideration of two types (single- and double-sided connections) and four levels of skew angle (0°, 10°, 20°, and 30°). The results indicated that the skewed connections considered in this study met the acceptance criteria for IMFs given by the codes. However, the load-carrying capacities of skewed connections were decreased as the skew angle increased. For the connection with a skew angle of 30°, the peak load was noted to be 13% less and the energy dissipation capacity could be 26% less than that of non-skewed connection. In addition, because of the skewed nature, the stress distribution in the skewed beam flange near the connection was asymmetric and the stresses were concentrated on the beam inner flange. Column twisting induced by the skewed configuration was very small and negligible in the beam and column combination considered in this study.