• Title/Summary/Keyword: 구속 이음

Search Result 29, Processing Time 0.021 seconds

shear Tests on female-to-female Type Joint between Precast Concrete Bridge Decks (프리캐스트 콘크리트 교량바닥판 female-female이음부의 전단실험)

  • 김영진;김영진;김종희
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.161-168
    • /
    • 1998
  • Increase of traffic volume in recent years results in deterioration of the bridge slab, which is directly subjected ot vehicle loads. Where extensive repair is necessary, replacement or enhancement of load carrying capacity using full depth precast concrete deck is often the most practical solution. Precast deck system has transverse joints between adjacent precast decks. Vertical shear forces occur when a vehicle wheel load is carried by precast decks and the joints are used to transfer the load to an adjacent deck. Effective load transfer between precast decks is critical for integral behavior. Finite element analysis and tests were run on the proposed femal-to-female type joint. 18 joint specimens were tested to investigate the effects of angle. D/H, and confining stress under static load. Results indicate joint with angle of 60$^{\circ}$ and D/H of 1/4 shows the improved load carrying capacity on crack. It is effective in protecting the cracking of joints to keep the joint in compression using confining stress.

Experimental Study on Effect of Confinement Details for Lap Splice of Headed Deformed Reinforcing Bars in Grade SD400 and SD500 (구속상세가 SD400 및 SD500 확대머리 이형철근의 겹침이음에 미치는 영향에 관한 실험적 연구)

  • Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.62-71
    • /
    • 2015
  • KCI 2012 and ACI318-11 contains development length provisions for the use of headed deformed bars in tension and does not allow their tension lap splices. In ACI318-11, the confinement factor, such as transverse reinforcement factor, is not used to calculate the development length of headed bars. The purpose of this experimental study is to evaluate the effect of confinement details to the lap splice performance of headed deformed reinforcing bars in grade SD400 and SD500. The confinement details are stirrups and tie-down bars in lap zone. Test results showed that specimens with only stirrups had the brittle failure and could not increase lap strengths, and that specimens with composite confinements by stirrups and tie-down bars had the flexural strengths over than nominal flexural strengths. Stirrups with tie-down bars can have an effect on improvement in lap splice of headed bars in grade SD400 and SD500.

Effect of Mechanical Constraints on the Angular Distortion of Welding Joints (용접 각변형에 미치는 구속도의 영향)

  • Park, Jeong Ung;Lee, Jae Won;Lee, Hae Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.5
    • /
    • pp.547-556
    • /
    • 2001
  • This study presents new method in which to derive the constraint coefficient from the quantity of angular deformation by welding measured by varying the shape of welded joints and the magnitude of constraints by varying the shape of welded joints and the magnitude of constraints by experiment and from the result analyzed by elastic FEM method and then to decide equivalent load with it The numerical analysis results by this new method verified the validity by agreeing with the experimental result on specimen. In addition These results are applicable to the prediction of the quantity of welding deformation for large structures regardless of the size and the shape While in the effects of the constraints based on the shape of welded joints in the case of Butt welding when the constraint coefficients are not considered the deformed quantity is produced larger than one by the experiment and consequently is largely affected by the constraints But in the case of Fillet welding the deformed quantity is seldom affected regardless of considering the constraint coefficients or not.

  • PDF

Fragility Curves of Seismic Retrofitted Concrete Bridges (내진보강된 콘크리트 교량의 손상도 곡선)

  • Kim, Sang-Hoon;Kim, Doo-Kie;Seo, Hyeong-Yeol;Kim, Jong-In
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.203-210
    • /
    • 2004
  • The fragility curves of seismic retrofitted bridges by steel jacketing at bridge columns and restrainers at expansion joints after the 1994 Northridge earthquake are developed. Fragility curves are represented by lognormal distribution functions with two parameters (median and log-standard deviation) and developed as a function of peak ground acceleration(PGA). Two parameters in the lognormal distribution are estimated by the maximum likelihood method. The sixty ground acceleration time histories for Los Angeles area developed for FEMA SAC project are used for the dynamic analysis of bridges. The comparison of fragility curves of the bridges before and after column retrofit demonstrates that the improvement of the bridges with steel jacketing on the seismic performance is excellent for the damage states defined in this study. The comparison of fragility curves of the bridges before and after the installation of restrainers at expansion joints also shows the improvement in the seismic performance of restrained bridges for the severe damage state.

Crack Control of Wall type Structures by Shrinkage and Temperature Reinforcement (수축ㆍ온도 철근에 의한 벽체형 철근 콘크리트 구조물의 균열 제어)

  • 김영진;김상철
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.2
    • /
    • pp.52-60
    • /
    • 2002
  • 지하철 구조물과 같은 매스 콘크리트 구조물을 시공할 때 온도 측정을 하는 경우는 많으나 이는 내외부 온도차를 적정한 수준으로 유지하여 균열 발생을 제어하기 위한 수단일 뿐 균열폭을 일정한도 내로 제어할 수 있는 조치는 아니다. 매스 콘크리트 구조물에서 균열폭을 제한 값 이하로 하기 위해서는 적절한 양의 철근을 배치하여야 한다. 또한 시공 이음 등을 작은 간격으로 설치하는 것은 구속도를 완화시키고 온도응력이나 균열폭을 저감시켜 균열 제어상 매우 효과적인 수단이 될 수 있다. 그러나 시공 이음, 균열 유발 줄눈 등의 이음간 간격을 좁히면 내하력 수밀성, 내구성 등에 악영향을 미칠 가능성이 높고, 타설 회수가 많아져 동일한 공정이 반복 투입되므로 시공 속도의 저하 및 공사비 상승 등의 단점이 나타날 수 있다.(중략)

Strength of Compression Lap Splice in Confined Concrete (횡구속된 콘크리트에서 압축이음강도)

  • Chun, Sung-Chul;Lee, Sung-Ho;Oh, Bo-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.855-858
    • /
    • 2008
  • A compression lap splice can be calculated longer than a tension lap splice in high strength concrete according to current design codes. Including effects of transverse reinforcement, a compression splice becomes much longer than a tension splice. Effects of transverse reinforcement on strength and behavior of compression lap splice, which always exist in actual structures, have been investigated through experimental study of column tests with concrete strength of 40 and 60 MPa. Confined specimens have twice of calculated strengths by current design codes. New design equations for the compression lap splice including the effects of transverse reinforcement are required for practical purpose of ultra-high strength concrete. End bearing is enhanced by transverse reinforcement placed at ends of splice not by transverse reinforcement within splice length. As more transverse reinforcement are placed, the stresses developed by bond linearly increase. The transverse reinforcements at ends of splice a little improve the strength by bond.

  • PDF

Behavior of angular distortion in butt joint welding of thin plate structure (맞대기 용접시의 각변형 거동에 관한 연구)

  • 배강열;김희진
    • Journal of Welding and Joining
    • /
    • v.6 no.3
    • /
    • pp.21-26
    • /
    • 1988
  • The behavior of angular distortion in butt joint wleding of thin plate structure is investigated with an experimental model and partially with a computational model. The experimental model studying the effects of specimene size and degree of restraint on the angular distorion offers a good method for analyzing the behavior of the distrotion. In addition, the distrotion during welding was demonstrated by both experimental measurement and numericla prediciton. The facts evealed in this study are as follows : 1) distrotion angles were changed with variations of specimene wldth. 2) With the restraint, angular distrotion was reduced to 20% to that of free joint. 3) After the restraint being removed, the effect of restraint was also remained. 4) Same heat input per unit thickness caused same amount of distortion. 5) The mode of angular distortion was expected to be changed with expected to be changed with time, i.e. convex movement during heating and concave one during cooling.

  • PDF

Method of assessment for allowable size of weld defects (熔接缺陷의 許容限界 評價方法)

  • 강성원
    • Journal of Welding and Joining
    • /
    • v.9 no.3
    • /
    • pp.10-17
    • /
    • 1991
  • 용접구조물에서 용접이음부가 차지하는 비율은 매우 작은 경우가 많지만 용접이음부에는 각종 초기결함(이들 결함으로부터 진전하는 피로 균열, 환경에 의한 균열등을 포함) 및 용접 초기의 부정형을 비롯해서 형상적 불연속 등에서 유기되는 국부적인 응력, 변형률의 집중, 잔류응력, 구속응력, 용접금속이 갖는 숙명적인 야금적 특성의 불균일, bond부 및 HAZ부에서의 용접열 싸이클에 의한 재질의 국부적 강도저하등 용접부의 강도를 저하시키는 인자들이 복합되기 쉽고, 용접구조물 전체의 내파괴 건전성평가에서 용접부가 파괴 강도는 매우 중요하다. 용접구조물의 설계, 시공의 목적은 소요성능의 확보에 있고 구조물이 사용중에 성능손실이나 불안정 파괴가 발생하지 않도록 하는 것이 주요요건이 될 것이다. 현재의 제강기술수준에서 볼 때 모재의 강 도보다 오히려 용접부의 강도 특히 피로강도 및 파괴 인성을 적절하고 합리적으로 평가하는 것이 매우 중요하다고 해도 과언이 아닐 것이다. 용접부의 강도를 평가하는데 있어서 용접부에 발 생하는 용접결함에 대한 평가는 매우 중요하며 이들 결함에 대한 허용결함한계를 평가하여 보수 여부 및 용접구조물의 신뢰성을 평가 할 필요가 있다.

  • PDF

Seismic Retrofit of RC Columns with Lap-Spliced Longitudinal Rebars Wrapping by SMA Wires (SMA Wire를 이용한 주철근 겹침이음된 RC 교각의 내진 보강 연구)

  • Park, Yong-Kwon;Lee, Yeon-Hun;Yang, Dong-Wook;Lim, Hyeon-Sik;Chung, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.129-130
    • /
    • 2010
  • Lap splice of longitudinal reinforcing steels was located in the plastic hinge region of most bridge piers that had been designed and constructed before the adoption of the 1992 seismic design provision of Korea Highway Design Specification. This research aims at improving the seismic performance of reinforced concrete bridge piers with lap-spliced longitudinal steels, of which the plastic hinge region was wrapped by the shape memory alloy (SMA) wires. Quasi-static test was used to investigate the seismic behaviours of RC test specimens.

  • PDF

Influence of Transverse Reinforcement Elements for Flexural Strength of Lap Spliced Ultra-high-strength Reinforced Concrete Beams (겹침이음된 초고강도콘크리트 보의 휨강도에 횡방향보강 요소가 미치는 영향)

  • Bae, Baek-Il;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.135-142
    • /
    • 2022
  • In this study, lap spliced ultra-high strength reinforced concrete beams were tested and the code criteria for calculating the lap splice length which was affected by the transverse reinforcement and concrete covering performance were reviewed. The main variables for test were set as fiber volume fraction and transverse reinforcing bar arrangement to improve the confining performance of the concrete cover. The change of the confining performance of concrete cover according to the increase in the fiber mixing amount at 1% and 2% volume ratio was examined, and D10 stirrups with a spacing of 100 mm were placed in the lap spliced region. As a result of the test, the specimens confined by the stirrups showed a sudden drop of load bearing capacity with horizontal cracking at the position of tensile longitudinal reinforcement. However, horizontal cracks were not appeared at the location of longitudinal reinforcement for the specimens with steel fiber. And these specimens showed gradual decrease of load bearing capacity after experiencing peak load. In particular, it was found that the strain at the position of the tensile longitudinal reinforcements of the specimens to which the mixing ratio of 2% was applied exceeds the yield strain. As a result of measuring the strain on the concrete surface, it was found that the fiber was more effective in preventing damage to the concrete surface than the stirrups for short lap spliced region.