• Title/Summary/Keyword: 구면렌즈

Search Result 137, Processing Time 0.029 seconds

A Relationship between Corneal Eccentricity and Stable Centration of RGP Lens on Cornea (각막 이심률과 RGP 렌즈의 중심안정위치와의 상관관계)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.373-380
    • /
    • 2012
  • Purpose: The present study was performed to investigate a relationship between the stable centrations of spherical RGP lens and aspherical RGP lens on cornea and corneal eccentricity. Methods: Two RGP lenses with different designs were fitted in alignment, steep or flat on total 84 eyes having corneal eccentricity of 0.28~0.78. The stable centration of lenses on cornea was analyzed by taking photographs with a high-speed digital camera. Results: The stable centrations of spherical and aspherical RGP lenses in horizontal direction were decentrated to temporal side. More centration to median side was shown when corneal eccentricity was larger. The difference between the stable centrations of spherical and aspheric RGP lenses according to corneal eccentricity was bigger when the fitting state was flatter. The difference in the stable centrations of aspherical RGP lens was smaller than that of spherical RGP lens regardless of fitting status. The stable centrations of spherical and aspherical RGP lenses in vertical direction were located below corneal apex regardless of fitting status however, there was no significant difference analyzed by the variation of corneal eccentricity. However, there were many cases that RGP lenses were in upper eyelid with increasing corneal eccentricity. Conclusions: The consideration of corneal eccentricity is required for RGP lens fitting and manufacturing aspherical RGP lens since the stable centration of spherical RGP lens as well as aspherical RPG lens' centration was changed depending on corneal eccentricity.

Study of an Aspherical Lens Design Method for Removing the Spherical Aberration of a Human Eye (눈의 구면수차 제거를 위한 비구면 렌즈 설계 기법 연구)

  • Kim, Ji Sung;Kim, Dong Min;Jin, Jong Hyun;Kim, Young Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.6
    • /
    • pp.299-305
    • /
    • 2015
  • Using Snell's Law without approximation, we analyzed focal points for parallel rays incident upon the cornea of a human eye. To calculate a ray's incident angle versus incident height for focusing on the same point, we used the ray reverse tracing method. We derived the theoretical conditions for an aspherical lens to remove the spherical aberration caused by a human eye. In this research, we held the rear surface of the lens to be spherical, for simple calculation, and calculated the lens curvature of the front surface to design an aspherical surface.

Changes of Corrective Astigmatism Values Depending on Position of Circle of Least Confusion in Astigmatic Refining Test Using Cross Cylinder (크로스실린더를 이용한 난시정밀검사에서 검사 전 최소착란원 위치에 따른 난시교정값의 변화)

  • Kim, Sang-Yeob;Lee, Min Jae;Lee, Kang Cheon;Lee, Tae Hui;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.349-354
    • /
    • 2015
  • Purpose: To investigate the changes of corrective values of astigmatism caused by the position of circle of least confusion on retina in refining astigmatic test using cross cylinder. Methods: 62 subjects (115 eyes) aged $22.24{\pm}2.48$ years participated for this study. After astigmatic test using a radial chart, refining test was performed using a cross cylinder in a condition of maximum plus to maximum visual acuity (MPMVA). Astigmatic refining test was repeatedly performed in each condition of which S+0.75 D, S+0.50 D, S+0.25 D, S-0.25 D, S-0.50 D, and S-0.75 D are added to spherical lenses of MPMVA. The measured values were compared with the values in MPMVA condition. Results: As compared with values in condition of MPMVA, change of astigmatic axis was increased with add the power of (+) spherical lenses and (-) spherical lenses. In same spherical condition, change of astigmatic axis was decreased with increment of astigmatic power (p<0.05). The corrective power of astigmatism was reduced with increment of (+) spherical lenses (p<0.05), and was raised with increment of (-) spherical lenses compared with the power in MPMVA condition. In case of adding (+) spherical lenses, difference of astigmatic power increased with increment of corrective astigmatism power in same test condition. Conclusions: In order to obtain a proper values for corrective astigmatism, position of circle of least confusion should be accurately adjusted before the performing an astigmatism's refining test.

A Study of the Refraction State on Spherical Lens and Aspherical Lens (구면렌즈와 비구면렌즈를 착용한 굴절이상안의 비교에 관한 연구)

  • Kang, Hyang Nyeo;Kim, Jin Koo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.43-47
    • /
    • 2001
  • The classifying distribution by the Spherical lens and Aspherical lens was middle myopic, middle myopic astigmatism middle mixed astigmatism compared. The refractive erroeye spherical lens were S-3.00 ~ S-6.00Dptr for the middle myopic 16%, S-6.00Dptr 19%, S-3.00C-0.50(90.180) ~ S-6.00C-2.00Asix(90.180)57%, S-3.00C+0.50(90.180) ~ S-6.00C+2.00Axis(90.180) 8% for the compound myopic astigmatism. Aspherical lens were S-3.00 ~ S-6.00Dptr for the middle myopic 31%, S-6.00Dptr 36%, S-3.00C-0.50(90.180) ~ S-300C-2.00Axis(90.180) 21%, S-3.00C+0.50(90.180) ~ S-3.00C+2.00Axis(90.180)12%, for the compound hyperopic astigmatism.

  • PDF

Changes of Stereoacuity with Correction in Induced Anisometropia (유발된 부동시의 교정에 따른 입체시 변화)

  • Choi, Jin Young;Kim, Jai-Min;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.121-126
    • /
    • 2008
  • Purpose: To study the minimum diopter of spherical lens with normal binocular function in induced anisometropia by over-correction or under-correction in single eye. Methods: Stereoacuity of subjects without ophthalmic disease history in their twenties was measured by using Titmus-fly stereotest at 40 cm after overcorrection or under-correction in non-dominant eye or dominant eye, respectively. Results: In induced anisometropia, the stereoacuity decreased with increase of the power of added spherical lens in either nondominant eye or dominant eye. And the first reduction of stereoacuity was more prominent with the addition of (+) spherical lens than (-) spherical lens. In addition, there was more strikingly decrement of stereoacuity with addition of spherical lens to dominant eye than non-dominant eye. Conclusions: In induced anisometropia, the most outstanding reduction of stereoacuity was obtained with increment of the power of added (+) spherical lens in case of non-dominant eye with full correction and dominant eye with addition of spherical lens.

  • PDF

A Relationship between Corneal Type, Corneal Astigmatism and Lens Fitting States and the Stable Centration of Spherical RGP Lens (각막형상, 각막난시 및 렌즈 피팅상태와 구면 RGP렌즈의 중심안정위치와의 상관 관계)

  • Lim, Shin Gyu;Lee, Min Ha;Choi, Sun Mi;Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.143-151
    • /
    • 2012
  • Purpose: The present study was conducted to investigate whether there is any difference in the centration of spherical RGP lens on cornea according to corneal types, corneal astigmatism and lens fitting states. Methods: Spherical RGP lens was fitted on 29 eyes of round-typed cornea and 45 eyes of symmetric bowtie-typed cornea with 0.00~2.75 D of corneal astigmatism in alignment, steep or flat. Their lens centrations on cornea were analyzed by taking photographs. Results: The centration of spherical RGP lens in the vertical direction was decentrated to downward direction in all cases, and the degree of decentration was not consistent. The lens centration in horizontal direction was significantly more-decentrated to the temporal meridian as base curve of lens was increased, and the degree of decentration was different according to the corneal type, corneal astigmatism and fitting states. With the same degree of astigmatism, the lens decentration to the temporal meridian was bigger in round-typed cornea than that in symmetirc bowtie-typed cornea. Conclusions: The centration of spherical RGP lens varies depending on lens fitting states, corneal astigmatism, and corneal types. Thus, the consideration of these factors may improve the success rate in RGP lens prescription.

Measurement of Spherical Aberration and Light Concentrating Efficiency of Lens by Using Thermocouple (열전대를 이용한 광학렌즈의 구면수차와 집광성능 측정)

  • Kim, Han-Seob;Park, Kyu-Yeol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.172-177
    • /
    • 2007
  • In this paper, spherical aberration and light concentrating efficiency of lens was measured. The measuring system is applying spherical aberration occurrence principal and could measure a temperature at focal plane by using the thermocouple. The sun which is located in infinite distance and could makes parallel ray is used as a illuminant or heat source in experiments. It is confirmed that light concentrating efficiency of optical lens is in inverse proportion to spherical aberration and.

Effects on Injection Time. Filling Pressure, and holding Time on Injection-molded Lens Pats (렌즈 성형품에 대한 사출시간, 충진 압력, 그리고 보강시간의 영향)

  • 송영현
    • The Korean Journal of Rheology
    • /
    • v.4 no.2
    • /
    • pp.116-126
    • /
    • 1992
  • 본 연구에서는 형내압 파형제어 시스템, 초고속, 사출성형, 그리고 금형진공 시스템 등을 갖춘 사출 성형기를 이용하여 정밀 구면렌즈를 성형하기 위한 실험을 수행하였다. 이 러한 목적을 위해 성형공정 변수인 사출시간 충전압력 그리고 보압시간이 성형품에 미치는 영향을 중량과 곡률반경 구면 정밀도 그리고 구면오차의 간접무늬를 측정하여 연구하였다. 그결과로서 성형품의 중량(칫수)과 곡률반경에 지대한 영향력을 행사하는 변수는 충전압력 이며 사출시간과 보압시간은 곡률반경과는 무관해 보이고 중량의 증가에는 기여하지만 공정 사이클 시간을 증가시키는 문제가 지적된다. 구면정밀도 측정실험 결과 길지도 짧지도 않는 15∼20초 사이의 보압시간 4초이내의 빠른 사출시간 그리고 860kg/cm2 이상의 높은 충전압 력에서 우수한 결과를 보여주었다, 마지막으로 구면의 형상에 대한 간접무늬 측정결과는 성 형공정을 이해하는데 강력한 도구가 됨을 발견하였다.

  • PDF

The Comparison of Fluorescein Patterns between Spherical RGP Lens and Aspherical RGP Lens by Corneal Type and Astigmatic Degree (각막형상과 난시도에 따른 구면 RGP 렌즈와 비구면 RGP 렌즈의 플루레신 염색 패턴 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.37-45
    • /
    • 2012
  • Purpose: The change of alignment between RGP lens and cornea according to the lens design was investigated by comparing the areas of fluorescein pattern in central and peripheral regions analyzed by astigmatic degree and corneal type when spherical and aspherical RGP lenses fitted in alignment. Methods: The fluorescein patterns of 90 eyes (19-30 years, $25.12{\pm}3.52$) having with-the-rule astigmatism were analyzed after spherical and aspherical RGP lenses fitted in alignment. Then, their fluorescent areas in central and peripheral regions were calculated and compared for the quantitative evaluation. Results: The case showing concordant base curve between spherical and aspherical RGP lenses in alignment fitting was 72% however, the possibility to have same base curves between spherical and aspherical RGP lenses in alignment fitting was to be less in the case of symmetric bowtietyped cornea and high astigmatism. The fluorescent area in peripheral region of aspherical RGP lens in alignment fitting was smaller than it of spherical RGP lens. Peripheral fluorescent areas in both RGP lenses decreased according to the increase of astigmatic degree and peripheral area in symmetric bowtie-typed corea was smaller than round-typed cornea's peripheral area. In the case of same astigmatic degree, peripheral fluorescent area of aspherical RGP lens was smaller in both corneal types. Conclusions: The results above suggest the changing degree in the alignment between RGP lens and cornea can be varied according to lens design, corneal astigmatism and corneal type. Thus, the results obtained from the quantitative analysis of the alignment between lens design and cornea may be used as the basic information about the establishment of guidelines for RGP lens fitting, the development of proper lens design, and different tear volume in partial regions.

Thermal Deformation Measurement Spherical Glasses Lens Using ESPI (ESPI를 이용한 안경용 렌즈의 열변형 측정)

  • Kim, Koung-Suk;Jang, Ho-Sub;Kim, Hyun-Min;Yang, Seung-Pill
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.137-143
    • /
    • 2008
  • The spherical glasses lenses are typically classified into two groups such as (+) diopter lens and (-) diopter lens by the refractive power index. The thermal deformation of a lens is occurred by external heat source and is changed respected to the diopter of a lens. In this paper, the thermal deformation of spherical glasses lenses were quantitatively measured by using ESPI (electronic speckle pattern interferometry) which has an advantage that the non-contact, non-destructive and precise deformation measurement is available due to the coherency characteristic. The temperature changes were measured by IR camera. It makes experiments over 14 types of the plastic glasses lenses. From the results, it was confirmed that the larger diopter lens showed the less thermal deformation in case of the (+) diopter lens. On the other hand, the thermal deformation of the (-) diopter lens was measured with uniform pattern when the same temperature changes were applied. Also, it was found that the thermnal deformation of the (+) diopter lens is less than that of the (-) diopter lens. Therefore, it is expected that when the thermal deformation is occurred to the various types of the lens, the variation of the focal length caused by the thermal distortion of a lens would be measured quantitatively.