• Title/Summary/Keyword: 구리회수

Search Result 147, Processing Time 0.028 seconds

Evaluation of Separation on the Copper Recovery from Jelly filled type Cable (젤리충전통신케이블의 구리회수를 위한 친환경적 분리기술평가)

  • Min, Dal-Ki;Sung, Il-Wha
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.21-26
    • /
    • 2003
  • The generation of waste cable has been continuously increased as a production of electrical and communication media are extended. The current recovery methods, such as mechanical peeling, incineration, solvent extraction and pyrolysis, seems inadequate because they are either hard to apply in some cases or environmentally unacceptable. It has been shown that copper can be effectively separated from the jelly filled type cables using a soybean oil treatment method. As a result, jelly compound is vanished from the wire by soybean oil bath and waste wires are separated copper and PE by the mechanical chipper. This is a more environmentally friendly method than burning, and considerably faster than Stripping.

Recycling of Acidic Etching Waste Solution Containing Heavy Metals by Nanofiltration (II) : Dead-end Nanofiltration of PCB Etching Waste Solution Containing Copper Ion (나노여과에 의한 중금속 함유 산성 폐에칭액의 재생(II) : 구리이온을 함유한 PCB 폐에칭액의 Dead-end 나노여과)

  • Nam, Sang-Won;Jang, Kyung-Sun;Youm, Kyung-Ho
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.92-99
    • /
    • 2013
  • In this study the nanofiltration (NF) membrane treatment of a sulfuric acid waste solutions containing copper ion ($Cu^{+2}$) discharging from the etching processes of the printed circuit board (PCB) manufacturing industry has been studied for the recycling of acid etching solution. SelRO MPS-34 4040 NF membrane from Koch company was tested to obtain the basic NF data for recycling of etching solution and separation efficiency (total rejection) of copper ion. NF experiments were carried out with a dead-end membrane filtration laboratory system. The pure water flux was increased with the increasing storage time in sulfuric acid solution and lowering pH of acid solution because of the enhancement of NF membrane damage by sulfuric acid. The permeate flux of acid solution was decreased with the increasing copper ion concentration. Total rejection of copper ion was decreased with the increasing storage time in sulfuric acid solution and copper ion concentration, and lowering the pH of acid solution. The total rejection of copper ion was decreased from initial 37% to 15% minimum value.

Copper Isotope Measurements Using a Neptune MC-ICP-MS (다검출기 유도결합 플라즈마 질량분석기를 이용한 구리 동위원소 분석법)

  • Park, Sanghee;Ryu, Jong-Sik;Shin, Hyung Seon;Kil, Youngwoo;Jo, Yunsoo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.221-227
    • /
    • 2016
  • Copper is an essential transition metal involving in various biogeochemical processes. With the recent advances in analytical techniques and mass spectrometry, such as MC-ICP-MS, it is possible to measure Cu isotopes, which allows us to understand various biogeochemical processes in detail. Nonetheless, few studies have been performed in South Korea. In this study, we compared two purification methods previously reported using an anion exchange resin ($AG^{(R)}$ MP-1M), developed the best method in our lab environment, and then verified it by measuring Cu isotopic compositions in two USGS geological reference materials (BHVO-2 and BIR-1a). Although all matrix cations causing mass bias were effectively removed through both two methods with the yield of better than 95%, the method using the mixture of HCl and $H_2O_2$ only displays Cu isotopic compositions, in excellent agreement with reported values within the error. The method developed in this study is expected to be commonly applied to earth and environmental sciences.

Leaching behavior of copper using electro-generated chlorine in hydrochloric acid solution (전해생성(電解生成)된 염소(鹽素)에 의한 구리의 침출(浸出) 거동(擧動))

  • Kim, Eun-Young;Kim, Min-Seuk;Lee, Jae-Chun;Jung, Jin-Ki
    • Resources Recycling
    • /
    • v.15 no.6 s.74
    • /
    • pp.33-40
    • /
    • 2006
  • Leaching behavior of copper using electro-generated chlorine was investigated in hydrochloric acid solutions. When leached copper concentration was lower than 3.6g/L, the utilization efficiency of the electro-generated chlorine was close to 100% at $10mA/cm^2,\;25^{\circ}C$, 400 rpm in 1M HCl solutions. The concentration ot the leached copper over 3.6g/L caused the electrode potential to drop quietly, leading to a change or leaching mechanism. The leaching rate oi copper began to decrease at the concentration of copper 5.2g/L. This is probably due to the formation of a layer of CuCl on Cu metal in 1M HCl solutions. The leaching rate, however, was not retarded in a solution ot high chloride concentration. The high solubility of CuCl in the solution may prevent the formation of CuCl on Cu metal.

NO Reduction Mechanism of Electrolytically Cu-plated Activated Carbon Fibers (전해 구리도금된 활성탄소섬유의 NO 환원반응 메카니즘)

  • 신준식;박수진;김학용;이덕래
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.04a
    • /
    • pp.309-310
    • /
    • 2003
  • 활성탄소 (activated carbons, ACs)는 넓은 비표면적을 가지고 있어 흡착용량이 크며, 발달된 미세공을 가지고 있기 때문에 오염물질의 제거능력이 높을 뿐만 아니라 경제적, 환경 친화적인 측면에서도 유리하다. 특히 섬유화된 할성탄소섬유 (activated carbon fibers, ACFs)는 균일한 세공이 표면에 노출되어 있어 흡착속도가 빠르며, 안정성과 재생성이 좋고 섬유상이기 때문에 가공이 용이하며 직포, 부직포, 시트 등의 형태로 만들어져 용매회수, 공업제품의 정제, 오폐수의 처리시설, 소각시설의 유해 배기가스의 흡착등에 널리 사용되고 있다.[1,2] (중략)

  • PDF

Separation of Valuable Metal from Waste Photovoltaic Ribbon through Extraction and Precipitation

  • Chen, Wei-Sheng;Chen, Yen-Jung;Yueh, Kai-Chieh
    • Resources Recycling
    • /
    • v.29 no.2
    • /
    • pp.69-77
    • /
    • 2020
  • With rapid increasing production and installation, recycling of photovoltaic modules has become the main issue. According to the research, the accumulation of waste modules will reach to 8600 tons in 2030. Moreover, Crystalline-silicon (c-Si) Photovoltaic modules account for more than 90% of the waste. C-Si PV modules contain 1.3% of weight of photovoltaic ribbon inside which contains the most of lead, tin and copper in the PV modules, which would cause environmental and humility problem. This study provided a valuable metal separation process for PV ribbons. Ribbons content 82.1% of Cu, 8.9% of Sn, 5.2% of Pb, and 3.1% of Ag. All of them were leached by 3M of hydrochloric acid in the optimal condition. Ag was halogenated to AgCl and precipitated. Cu ion was extracted and separated from Pb and Sn by Lix984N then stripped by 3M H2SO4. The effect of the optimal parameters of extraction was also studied in this essay. The maximum extraction efficiency of Cu ion was 99.64%. The separation condition of Pb and Sn were obtained by adjusting the pH value to 4 thought ammonia to precipitate and separate Pb and Sn. The recovery of Pb and Sn can reach 99%.

Study on Synthesis of Fine Copper Powder by Electro-refining from Copper Containing Sludge (동(Cu) 함유 슬러지로부터 동 전해정련을 이용한 미세 동 분말 합성에 관한 연구)

  • Lee, Jin-Yeon;Son, Seong Ho;Park, Sung Cheol;Jung, Yeon Jae;Kim, Yong Hwan;Lee, Man-seung
    • Resources Recycling
    • /
    • v.27 no.6
    • /
    • pp.44-52
    • /
    • 2018
  • In this study, copper was recovered from copper containing sludge by selectively controlling electro-refining process conditions in copper sulfate electrolyte solution. Electro-refining process was performed by LSV (Linear Sweep Voltammetry) result according to copper sulfate electrolyte solution concentration, applied current density, additive type and concentration. SEM (Scanning Electron Microscope) and PSA (Particle Size Analyzer) were used to analyze the shape and size of copper powder. In the 0.1 ~ 0.4 M copper sulfate electrolyte solution without organic additives, the copper powder size decreased as the applied current density became closer to the limiting current density and the copper powder size tended to decrease in 0.2 ~ 0.3 M copper sulfate electrolyte solution. In addition, when the shape and size of the copper powder were analyzed by adding various types and concentrations of organic additives to the previous experimental, fine spherical copper powder having the smallest size (nm) was obtained under the condition of cellulose type additive 2,000 ppm.

Recovery of Precious Metals in Plating Rinsed Wastewater Generated from Lead Frame Manufacturing Process (Lead Frame 제조공정에서 발생되는 도금세정폐수 중 유가금속회수)

  • Kim, Jae-Yong;Um, Myeong-Heon;An, Dae-Hyun;Shim, Myeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.17 no.4
    • /
    • pp.343-348
    • /
    • 2006
  • The object of this experiment is to recover precious metals from plating rinsed wastewater generated from Lead Frame manufacturing process using electrolysis coupled hybrid process. This was achieved from Amberlite IRA 400 at 1.15 V electrolysis potential using the oxide electrode and at 1.30 V using the Al electrode and from Amberlite IRA 402 at 1.10 V using the oxide electrode and at 1.20 V using the Al electrode. During the first 10~30 min of the process, 90~95% of the silver can be recovered.

Physical Property Changes of Wasted Printed Circuit Board by Heat Treatment (열처리에 의한 폐 인쇄회로기판의 물성변화)

  • Kim, Boram;Park, Seungsoo;Kim, Byeongwoo;Park, Jaikoo
    • Resources Recycling
    • /
    • v.27 no.1
    • /
    • pp.55-63
    • /
    • 2018
  • Physical property changes of printed circuit board (PCB) according to heat treatment conditions were investigated. The heat treatment was carried out in air and nitrogen atmosphere at temperature range from $200^{\circ}C$ to $325^{\circ}C$. Thermogravimetric analysis showed that the PCB was pyrolyzed in two steps. The thickness of PCB expanded by 11~28% at about $300^{\circ}C$ in both air and nitrogen atmosphere as layer disintegration occurred. Mechanical strength of PCB decreased from 338.4 MPa to 20.3~40.2 MPa due to the delamination caused by the heat treatment. The heated printed circuit boards were crushed and sieved for analysis of density distribution and liberation degree of copper according to particle size. As a result of the density distribution measurement, non metallic particles and copper particles were concentrated into different size range, respectively. The liberation degree of copper was improved from 9.3% to 100% at size range of $1,400{\sim}2,000{\mu}m$ by heat treatment.