• Title/Summary/Keyword: 구내방사선촬영

Search Result 48, Processing Time 0.028 seconds

A GEOMETRIC STANDARDIZATION OF PERIAPICAL INTRAORAL RADIOGRAPHY (구내 표준 방사선 사진촬영의 위치 표준화)

  • Choi Bong-In;Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.415-423
    • /
    • 1991
  • This study was performed to evaluate the geometric standardization of periapical intraoral radiography. Image distortion was measured by analysing serial radiography obtained from dry skull using 5 types of bite registration device. After 16 weeks, the angular distortion of Pattern resin was 0.26±0.14 degree(Horizontal angle 0.17±0.14, Vertical angle 0.16±0.11) which was the lowest among the 5 registration device, and that of putty type Exaflex was 0.49±0.35 degree(Horizontal angle 0.42±0.35, Vertical angle 0.17±0.13) which was the highest. The mean amount of distortion variance of Tooth shade acrylic at each experimental period was 0.06±0.08 which was the lowest among the 5 registration device, and that of XCP alone was 0.ll±0.13 which was the highest.

  • PDF

Quantitative assessment of alveolar bone density change after initial periodontal therapy using digital imaging (디지털영상을 이용한 초기 치주처치후 치조골 밀도변화의 정량적 평가)

  • Ahn, Kyung-Hyun;Kim, Jae-Duk;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.4
    • /
    • pp.777-785
    • /
    • 2001
  • 치주질환이 진행되는 동안이나 치주처치후 치유되는 과정에서 치조골의 변화가 야기되는데 방사선 사진은 치조골 변화를 감지하는 유일한 비외과적인 방법이다. 미묘한 치조골 변화의 진단은 치료시나 유지관리기 환자의 평가시 중요한 바, 최근에는 규격화시킨 디지털 영상을 이용하여 정량적인 골변화 측정이 가능하게 되었다. 본 연구의 목적은 중등도의 치주질환을 지닌 환자에서 국소마취하에 초기 치주처치를 시행한후 참조체와 함께 구내 방사선 사진을 촬영하고 디지털화 한 다음 참조체 당량치를 이용하여 치조골의 밀도변화를 평가하기 위한 것이다. 이 연구를 위하여 치주질환에 이환된 환자 5명(남자 3명, 여자 2명 : 평균 47.4세)에서 탐침깊이가 5㎜ 이상이고 골내낭이 있는 제 $1{\cdot}2$ 소구치, 제 $1{\cdot}2$ 대구치 40개(상악 24개, 하악 16개)를 대상으로 구강위생교육과 치석제거술, 치근면활택술을 시행하였다. 임상지수는 술전과 술후 8주째에 측정하였고, 방사선 사진은 술전, 술후 2주, 4주, 6주, 8주째에 촬영하였고, 구리 스텝웨지를 사용하여 규격화 하였다. 촬영된 영상은 NIH image program(U.S.A)에 의해 분석되어졌고 이들 자료를 통해 다음과 같은 결과를 얻었다. 1. 치조골의 밀도는 초기치료후 2주째 까지는 감소된 양상을 보이다가 4주 이후로는 점차적으로 증가하는 양상을 보였다. 2. 치조골의 밀도는 초기치료전과 비교시 초기치료수 6주째와 8주째에서 유의한 차이를 보였다.(p<0.01) 3. 상하악 간의 치조골 밀도는 유의한 차이를 보이지 않았다(p>0.05). 이상과 같은 결과를 통하여 볼때 초기 치주처치만으로도 치조골의 밀도가 증가됨을 확인할 수 있었다.

  • PDF

Evaluation of bone quality in alveolar crest obscured by dental implants ; A pilot study by densitometric digital analysis in mandibular bone specimen (치과 임플란트 주변 협설측 치조골의 변화분석 - 하악골 시편에서의 디지털 농도분석법을 이용한 실험적 고찰 -)

  • Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.900-913
    • /
    • 1998
  • Despite of technical difficulties, the combination of occlusal projection and densitometric digital analysis may ultimately provide a means of detection of subtle bone loss at the facial and lingual side of dental implant (Oblique occlusal view is more useful for $ITI^{(R)}$ dental implant due to its contour of shoulder as like tulip flower). In this study, conventional periapical projections of x-ray beam had shown more high sensitivity to detect the bony defects than oblique occlusal projections in alveolar crest obscured by dental implants or not, even if the difference was not statistically significant. Unlike conventional periapical projections. occusal projections combined with densitometric digital analysis technique may provide a means for detection of subtle bone change at the all around of implants without obscuring effect by implant itself. Although the results from this in vitro study were performed under limited circumstances, these results might afford more possibility and versatile modality of diagnosis options to clinician in the implant practice.

  • PDF

Feasibility study of insertable miniature x-ray source for dental imaging (치과 영상용 삽입형 초소형 X선 튜브의 가능성 연구)

  • Cho, Sung-Ho;Kim, So-Yeong;An, So-Hyun;Lim, Soo-Mee;Lee, Re-Na
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 2012
  • Conventional periphery radiography system has a various problem such as patient dose and the pain of X-ray examination. In this paper, to solve these problems, we suggested insertional miniature x-ray system and we verified the feasibility of this system. First, we performed the Geant4 x-ray simulation to design x-ray collimator and filter to use miniature x-ray tube and we decided optimized thickness of filter and collimator. Also, we measured x-ray spectrum using CdTe detector and PX4 module to verify simulation results. Also, we acquired teeth image of fabricated phantom using conventional dental x-ray and prosed miniature x-ray system. As a results, our system has good image quality as compared to those of conventional systems. Our evaluation of the proposed system indicates that it can be potentially very useful for dental imaging.

A RADIOLOGICAL STUDY ON THE ADDITIONAL ROOT OF THE MANDIBULAR FIRST MOLARS AND PREMOLARS (하악 제1대구치와 소구치의 과잉치근에 관한 방사선학적 연구)

  • Park Mi-Kyung;Na Chae-Young;Choi Karp-Shik
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.1
    • /
    • pp.19-25
    • /
    • 1993
  • The purpose of this study was to evaluate the prevalence and distribution of additonal root in the mandibular 1st molars and premolars by means of the analysis of the full mouth periapical radiographs in 6,082 patients visited the Dental Infirmary of Kyungpook National University Hospital from March 1989 to February 1993. The results were as follows: 1. The incidence of additional root in the mandibular 1st molars was revealed to be 9.32% in total examined patients, and there was a higher prevalence in males(I1.35%) than in females(7.46%). And bilateral occurrence was revealed to be 4.26%. 2. The incidence of additional root in the mandibular premolars was to be 3.57% in total examined patients, and there was a higher prevalence in males(4.28%) than in females(2.91%). And bilateral occurrence in the 1st premolars was revealed to be 1.53%.

  • PDF

Comparison between QraypenTM Imaging and the Conventional Methods of Visual Inspection and Periapical Radiography for Proximal Caries Detection in Primary Molars: An In Vivo Study (유구치 인접면 우식 병소 진단에 있어 QraypenTM과 시진 및 구내 치근단 방사선의 비교)

  • An, So-Youn;Park, So-Young;Shim, Youn-Soo
    • Journal of dental hygiene science
    • /
    • v.16 no.5
    • /
    • pp.349-354
    • /
    • 2016
  • The purpose of this study was to evaluate the efficacy of the newly-developed $Qraypen^{TM}$ (All In One Bio, Korea) system for the diagnosis of early proximal caries by comparing it with the conventional methods of visual inspection and periapical radiography. This study was carried out from July 2015 to April 2016 targeting 32 children aged 7~12 years who visited Y-Dental Clinic for school oral health examinations. Two investigators selected and examined a total of 153 primary molars that had not undergone restorative treatment. Comparisons were carried out between visual inspections, readings of posterior periapical radiography images, and readings of $Qraypen^{TM}$ images. This study revealed that the percentage of interproximal surfaces of primary molar teeth without caries incidence was 83.7% using $Qraypen^{TM}$ imaging and 84.9% using visual inspection and periapical radiography. The differences between the two methods were not statistically significant. Thus, $Qraypen^{TM}$ is expected to be a useful and convenient auxiliary diagnostic device that can facilitate the detection of hidden proximal caries in primary molars.

A study on radiation safety education, knowledge, and practice in using portable intraoral X-ray equipment of dental hygienist's (치과위생사의 이동형 구내방사선 촬영에 관한 방사선 방어 교육, 지식, 수행에 관한 연구)

  • Ryu, Jeong-Min;Kang, Bo-Sun;Kim, Seol-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.17 no.6
    • /
    • pp.1053-1065
    • /
    • 2017
  • Objectives: The purpose of this study is to evaluate radiation safety education, knowledge and practice of dental hygienists in using handheld portable intraoral X-ray equipment and to suggest the need for radiation safety education in using handheld portable intraoral X-ray equipment. Methods: We surveyed 223 dental hygienists from July, 2017 to August in the dental clinics of Daejeon, Seoul and Gyeonggi area. Results: Radiation safety educational experience was higher in a year's career (72.9%), than 3 years experience (32.5%) (p<0.05). 82.7% of dental clinic workers took university education for radiation safety education while 55.6% of dental hospital workers took company training (p<0.05). More than 70% of the subjects did not have experience of radiation safety education about using portable intraoral X-ray. Radiation safety knowledge was highest in a year's career (p<0.05). The cumulative dose, radiation sensitivity, and lead defense knowledge were high in all subjects, but knowledge related to scattering radiation and scattering radiation sources was low. Practice of portable intraoral X-ray safety was significantly lower than knowledge. Conclusions: Knowledge of portable intraoral radiography safety is available, but performance is poor. Even with the small amount of radiation exposure, the risk is perceivable. There is a need to actively utilize the provided radiation protection products. In order to do this, efforts should be made to improve knowledge and performance of radiation safety through not only college education but also postemployment training.

Reduction of Entrance Surface Dose Depending on Shielding Methods for Panoramagraphy (파노라마 X선 검사시 차폐방법에 따른 Entrance Surface Dose 저감)

  • Choi, Jung-Hyun;Kim, Sung-Chul;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.199-203
    • /
    • 2015
  • Panoramagraphy was the second most used intraoral radiography utilized in Korea, resulting in 17.8% in university dental hospitals, 24.8% in dental hospitals, and 31.4% in dental clinics. Depending on increased demand like orthodontics and implant, panoromagraphy tends to consistently increase. This study were used lead glasses and lead shielding to reduce unnecessary radiation to the eyeballs and thyroid. ESD was 41.4% when radiation was shielded with the lead glasses while reducing 47.3% of ESD by shielding the X-ray tube area with shielding lead. There was no statistically significant difference. The lead glasses is appropriated to reduce unnecessary radiation exposure to the eyeballs.

Absorbed and effective dose from periapical radiography by portable intraoral x-ray machine (이동형 구내 방사선촬영기로 촬영한 치근단 방사선사진의 흡수선량 및 유효선량 평가)

  • Cho, Jeong-Yeon;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.149-156
    • /
    • 2007
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for periapical radiography done by portable intraoral x-ray machines. Materials and Methods: 14 full mouth, upper posterior and lower posterior periapical radiographs were taken by wall-type 1 and portable type 3 intraoral x-ray machines. Thermoluminescent dosemeters were placed at 23 sites at the layers of the tissue-equivalent ART woman phantom for dosimetry. Average tissue absorbed dose and radiation weighted dose were calculated for each major anatomical site. Effective dose was calculated using 2005 ICRP tissue weighted factors. Results: On 14 full mouth periapical radiographs, the effective dose for wall-type x-ray machine was 30 Sv; for portable x-ray machines were 30 Sv, 22 Sv, 36 Sv. On upper posterior radiograph, the effective dose for wall-type x-ray machine was 4 Sv; for portable x-ray machines doses were 4 Sv, 3 Sv, 5 Sv. On lower posterior radiograph, the effective dose for wall type x-ray machine was 5 Sv; for portable x-ray machines doses were 4 Sv, 4 Sv, 5 Sv. Conclusion: Effective doses for periapical radiographs performed by portable intraoral x-ray machines were similar to doses for periapical radiographs taken by wall type intraoral x-ray machines.

  • PDF

STUDY OF INVERTLY IMPACTED SUPERNUMERARY TEETH IN THE MIDPALATAL REGION USING COMPUTERIZED TOMOGRAPHY (전산화 단층 방사선사진을 이용한 상악 정중부 역위 매복 과잉치에 관한 연구)

  • Choi, Byung-Jai;Lee, Yong-Seok;Kim, Seong-Oh;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.363-372
    • /
    • 2003
  • Supernumerary teeth are found frequently in the dental office causing many dental complications. They are one of the many dental abnormalities that may occur during tooth development. Inversely impacted supernumerary teeth in the midpalatal area are especially important clinically because they occur with high frequency and many complications. Though many previous clinical and radiographical studies exist, the sample numbers were small and the evaluation of shape, location, and effects to its surrounding tissue may not be accurate due to the solitary use of intraoral radiographs or panoramic radiographs. Among the patients who visited department of pediatric dentistry, yonsei dental hospital, from July, 1998 to June, 2002, those with inversely impacted supernumerary teeth took computerized tomography for a more accurate diagnosis. Their dental chart, panoramic radiograph and computerized tomography were evaluated for this study. The number, form, convexity, location, distance, and complications of inversely impacted supernumerary teeth in the midpalatal area were recorded. This study show that when the supernumerary teeth is tuberculated with a curved root and is in close proximity to the adjacent teeth, it causes complications such as eruption disturbance, rotation, displacement of adjacent teeth, and diastema. Such factors must be considered in making decisions for diagnosis and treatment.

  • PDF