Evaluation of the Bite Forces in Patients with Unilateral Temporomandibular Disorders (편측성 측두하악장애 환자의 교합력 평가)

  • Lee, Woo-Jung;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.4
    • /
    • pp.347-354
    • /
    • 2006
  • Most patients suffering from TMD appear to have unsatisfactory masticatory function and compromised values of bite force. The purposes of this study were to investigate and compare bite force between affected and unaffected sides of patients with unilateral TMD and to evaluate its relation with duration of TMD. 42 patients with unilateral TMD, from Department of Oral Medicine, Dankook University Dental Hospital, were selected for this study. The ratio of men to women was 9:33 and their mean age of $27.2{\pm}10.4$ years. The bite forces were measured over both canines (for anterior bite force) and $1^{st}$ molars (for posterior bite force) using a bite force recorder while all the subjects were asked to clench successively for 3 seconds not until pain was felt. They were compared with those measured from bilateral TMD patients(N=6, M:F=1:5, mean age: $23.0{\pm}27.3$ years). The unilateral TMD patients were divided into time groups according to duration of TMD on the basis of 1 and 6 months, respectively. Paired and unpaired t-tests were used for statistical analysis. Unilateral TMD patients in this study showed that the affected sides had significantly lower bite force than the unaffected sides(force difference of about 7-8 kgf, p<0.05) while there was no significant sides difference in the bilateral patients. Nor did bite force on the affected sides reveal significant difference between unilateral and bilateral TMD patients. With regards to TMD duration, there was significant difference between the patients with TMD < 6 months and $\geq$ 6 months (p<0.05) while no significant difference existed between < 1 month and $\geq$ 1 month. The results of this study indicated that unilateral TMD patients can exhibit more reduced bite force on the affected sides compared with that on the unaffected sides and that bite force on the unaffected sides might be deteriorated more as longer did TMD last.

Comparison of Bite Forces between Pre- and Post-Treatment in Patients with Temporomandibular Disorders (측두하악장애 환자의 치료 전후 교합력 비교)

  • Lee, Sang-Il;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.2
    • /
    • pp.211-218
    • /
    • 2007
  • The purpose of this study was to compare the maximum bite forces between pre- and post-treatment related to specific diagnostic groups of TMD including masticatory muscle disorder (MMD), disc derangement (DD), joint inflammation (JI) and osteoarthritis (OA). Bite force between pre- and post-treatment was compared in 36 patients with unilateral TMD, successfully-managed in the Department of Oral Medicine, Dankook University Dental Hospital, for this study. The ratio of men to women was 7:29 and their mean age of $28.1{\pm}13.7$ years. The patients were categorized, through clinical and radiographic examination, into aforementioned 4 groups; MMD (N=18), DD (N=6), JI (N=5) and OA (N=7). The maximum bite force measurements were done at the antagonizing canines and 1st molars using a bite force recorder. Paired t-test, ANOVA, Multiple Comparison t-tests were used for statistical analysis. The results of this study showed that the maximum bite force before treatment increased after TMD treatment, which was noticeable at the canines (p=0.001 and p=0.000 for the affected and unaffected sides, respectively). In comparison related to the diagnostic groups of TMD, patients with osteoarthritis of TMJ exhibited the lowest strength while those with inflammatory disorder of TMJ had the highest strength on the affected sides. Increase of bite force after treatment was also found in each group. Significant difference between pre- and post-treatment was found at canines on the affected sides in MMD (p=0.045) and DD groups (p=0.009) while on the unaffected sides in OA group (p=0.003). Conclusively, the reduced bite force due to TMD could be recovered by conservative TMD treatment and that the difference of bite forces between pre- and post-treatment was noticeable at the canines.

COMPARISON OF BITE FORCE WITH DENTAL PRESCALE AND UNILATERAL BITE FORCE RECORDER IN HEALTHY SUBJECTS (Dental Prescale과 편측 교합력 측정기를 이용한 정상성인의 교합력 비교)

  • Kwon Ho-Keun;Yoo Ja-Hea;Kwon Young-Sook;Kim Baek-Il
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.103-111
    • /
    • 2006
  • Statement of problem: The previous unilateral bite force recorder has several limitations for taking long time for measuring and causing discomfort to subjects. Because of these reasons, it could not use widely for epidemiological researches. However, 'Dental Prescale System' which is new equipment for measuring bite force, is more convenient for measuring bite force than previous unilateral recorder. Purpose: The purpose of this study was to compare a new technique(Dental Prescale System) using pressure sensitive foils for recording of maximal jaw closing force with conventional measurement using unilateral bite force recorder Material and method: This studies included 22 healthy dental students in college of dentistry Yonsei university in Rep of Korea. Mean age was 23.9 years. All subjects had continuous dental arches and no significant malocclusion or signs from the teeth and craniomandibular system. The Dental Prescale System (Fuji Film, Tokyo, Japan) consists of a horseshoe-shaped pressure sensitive sheet (50H, R type) and a computerized scanning system.(FPD705) We also used unilateral bite force recorder(Denbotics Co. Seoul, Rep.Korea) for comparing with Dental Prescale. Results and conclusion: The total bite force recorded with Dental Prescale System (1423 N) was systematically higher than that recorded by unilateral bite force recorder. (256 N) However, the maximum bite force values measured in the two ways were significantly correlated (r=0.46, p<0.05). The Dental Prescale bite force calculated for first molar (208 N) was lower than that recorded by unilateral bite force recorder. (256 N) The two values were also very significantly correlated. (r=0.66. p<0.001) There were significantly different in bite force between two measurement methods. The reasons were first, unilateral bite force recorder measured only the bite force of a part of teeth, and Dental Prescale measured the total teeth force. Second, in measurement, a difference in muscle contraction appeared by an extent of mouth-opening. Third, unilateral bite force recorder has the reducing effect of the bite force by protective tape. Fourth, Dental Prescale has limitations during the computer scanning procedure. Therefore, Dental Prescale System is considered to be a very promising alternative to be conventional bite force recording methods.

The effect of Zirconium Nitride coating on shear bond strength with denture base resin in Co-Cr alloy and titanium alloy (질화 지르코늄 코팅이 코발트 크롬 합금과 타이타늄 합금에서 의치상 레진과의 전단결합강도에 미치는 영향)

  • Park, Chan;Lee, Kyoung-Hun;Lim, Hyun-Pil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.194-201
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate of Zirconium Nitride (ZrN) coating on shear bond strength with denture base resin in Co-Cr and Ti-6Al-4V alloy. Materials and Methods: Co-Cr and Ti-6Al-4V alloy disks (10 mm in diameter, 2.5 mm in thickness; each other: n = 14) were prepared and divided with 2 groups each other by ZrN coating. After primer was applied to disks surface, denture base resin with diameter 6 mm, height 5 mm was bonded on metal disk surface. After surface roughness was measured by Profiler, shear bond strength was determined with Universal testing machine and analyzed with two-way ANOVA. The specimen surfaces and failure mode were examined using a scanning electron microscope. Results: ZrN coated groups showed significantly higher rough surface than non-coated groups (P < 0.05). Irrespective of alloy materials, shear bond strength of ZrN coated groups were lower than non-coated groups (P < 0.001). The scanning electron microscope (SEM) of ZrN coated groups showed mixed and adhesive fractures. Conclusion: ZrN coating weakened bonding strength between denture base resin and Co-Cr, Ti-6Al-4V alloy.

A STUDY OF ADDITIONAL VIBRATION EFFECT ON DENTIN BOND STRENGTH (진동이 상아질 결합력에 미치는 영향에 관한 연구)

  • Lee, Jin;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.632-640
    • /
    • 2002
  • The objective of the study was to apply the vibration technique to reduce the viscosity of bonding adhesives and thereby compare the bond strength and resin penetration into dentinal tubules achieved with those gained using the conventional technique. Eighty-eight noncarious extracted human permanent molar teeth were sectioned to remove the coronal enamel and were embedded in 1-inch PVC pipe with acrylic resin. The occlusal surfaces were placed so that the tooth and the embedding medium were at the same level to form one flat surface, and the samples were subsequently polished with silicon carbide abrasive papers. The samples were randomly assigned to 4 groups(n=22). On Group 1 and 2, Single Bond(3M-ESPE, St. Paul, USA) was used, and on Group 3 and 4, One-Step(Bisco Inc., Schaumburg, USA) was used, and each was applied according to its manufacturer's instructions. For Group 2 and Group 4, vibration was applied with ultrasonic scaler for 10 seconds, and the adhesive was light-cured for 10 seconds. Resin composite was condensed on to the prepared surface in two increments using a mold kit(Ultradent Products Inc., USA) and each was light-cured for 40 seconds. After 24 hours in tap water at room temperature the specimens were thermocycled, and shear bond strengths were measured with a universal testing machine(Instron 4465, Canton, USA). To investigate infiltration patterns of the adhesive materials, the surface of specimen was examined with scanning electron microscope. The results were as follows. 1. The shear bond strengths of vibration groups(Group 2, Group 4) were significantly greater than those of the non-vibration groups(Group 1, Group 3)(p<0.05). 2. The shear bond strengths of Single Bond and One-Step were not significantly different (p>0.05). 3. The vibration groups showed greater number of resin tags in tubules and lateral branches under SEM.