• Title/Summary/Keyword: 교차적층방식

Search Result 3, Processing Time 0.021 seconds

A study on application techniques in design phase of applying a crossing stacking method of modular housing (모듈러 저층집합주거의 교차적층방식 설계 적용기술 연구)

  • Jun, Young-Hun;Lee, Young;Kim, Kyoon-Tai
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.81-82
    • /
    • 2014
  • Modular housing has many advantages such as economy, flexibility and reusability. The domestic modular housing of a continuous stacking method has been built in military facilities, and dormitories. However, there is a limit to present diversity of low-rise multi-family housing. A cross stacking method is a way to pursue diversity of that but there is a difficulty to apply it owe to lack of cases and related technologies. Therefore, the purpose of this study is to suggest application techniques in design phase of applying the crossing stacking method in advance.

  • PDF

A Performance Analysis and Experiments on Plastic Film/Paper Humidifying Elements Consisting of Horizontal Air Channels and Vertical Water Channels (수평 공기 채널과 수직 물 채널로 구성된 플라스틱 필름/종이 가습 소자의 성능)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.1
    • /
    • pp.55-63
    • /
    • 2016
  • New materials and shapes for a humidifying element were developed which outperformed the widely used crisscross glass wool Glasdek media design. The new material consists of 50% cellulose and 50% PET. The parallel channel configuration was devised to reduce excessive pressure loss caused by the reduced height (from 7.0 mm to 5.0 mm) of the crisscross configuration. For the same crisscross configuration, the humidification efficiency of the cellulose/PET element was 26% higher than that of the glass wool element. For the same cellulose/PET material, humidification efficiency of the parallel channel configuration was 14% higher than that of the crisscross configuration. As for the pressure drops, the cellulose/PET element was 2-52% higher than those of the glass wool element. For the same cellulose/PET material, the pressure drop of the parallel channel configuration was 14% higher than that of the crisscross configuration. Data were compared against the predictions from existing correlations and those by the proposed model.

Evaluation of Long Term Operation of Cross-flow Molten Carbonate Fuel Cell Stack (교차류형 100W급 용융탄산염 연료전지 스택 장기운전평가)

  • Lim, H.C.;Seol, J.H.;Ryu, C.S.;Lee, C.W.;Hong, S.A.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.6 no.2
    • /
    • pp.53-63
    • /
    • 1995
  • A 100kW class stack consisting of 10 molten carbonate fuel cells has been fabricated. Internally manifold stack has been tested for endurance. Each cell in the stack had an electrode area of $100cm^2$ and reactant gases were distributed in each cells in a cross-flow configuration. Initial and long term operation performance of the stack was investgated as a function of gas utilization using a specially designed small scale stack test facility. It was possible to have a stack with an output of more than 100W using an anode gas of 72% $H_2/18%$ $CO_2/10%H_2O$ and cathode gas of 33% $O_2/67%$ $CO_2$ and 70% Air 30% $CO_2$. The output and voltage of the stack at a current 15A($150mA/cm^2$) and gas utilization of 0.4 showed 125.8W and 8.39V respectively by elapsed time of 310 hours operation. In long term operation characteristics, the voltage drop of 52.4mV/1000hour was observed after more than 1,840 hours operation. Among the voltage drop, the OCV loss was highest than other voltage loss such as internal resistance and electrode polarization. Non uniformity of 2voltages and degradation of cell voltage in the stack was observed in according to changing the utilization rate after a long term operation. Further work for increasing the performance prolonging the life of the stack are required.

  • PDF