• Title/Summary/Keyword: 교차계획

Search Result 177, Processing Time 0.027 seconds

Multimodal MRI analysis model based on deep neural network for glioma grading classification (신경교종 등급 분류를 위한 심층신경망 기반 멀티모달 MRI 영상 분석 모델)

  • Kim, Jonghun;Park, Hyunjin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.425-427
    • /
    • 2022
  • The grade of glioma is important information related to survival and thus is important to classify the grade of glioma before treatment to evaluate tumor progression and treatment planning. Glioma grading is mostly divided into high-grade glioma (HGG) and low-grade glioma (LGG). In this study, image preprocessing techniques are applied to analyze magnetic resonance imaging (MRI) using the deep neural network model. Classification performance of the deep neural network model is evaluated. The highest-performance EfficientNet-B6 model shows results of accuracy 0.9046, sensitivity 0.9570, specificity 0.7976, AUC 0.8702, and F1-Score 0.8152 in 5-fold cross-validation.

  • PDF

Accurate dam inflow predictions using SWLSTM (정확한 댐유입량 예측을 위한 SWLSTM 개발)

  • Kim, Jongho;Tran, Trung Duc
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.292-292
    • /
    • 2021
  • 최근 데이터 과학의 획기적인 발전으로 딥러닝(Deep Learning) 알고리즘이 개발되어 다양한 분야에 널리 적용되고 있다. 본 연구에서는 인공신경망 중 하나인 LSTM(Long-Short Term Memory) 네트워크를 기반으로 정확한 댐유입량 예측을 수행하는 SWLSTM 모델을 제안하였다. SWLSM은 모델의 정확도를 개선하기 위해 세 가지 주요 아이디어를 채택하였다. (1) 통계적 속성 (PACF) 및 교차 상관 함수(CCF)를 사용하여 적절한 입력 변수와 시퀀스 길이를 결정하였다. (2) 선택된 입력 예측 변수 시계열을 웨이블릿 변환(WT)을 사용하여 하위 시계열로 분해한다. (3) k-folds cross validation 및 random search 기법을 사용하여 LSTM의 하이퍼 매개변수들을 효율적으로 최적화하고 검증한다. 제안된 SWLSTM의 효과는 한강 유역 5개 댐의 시단위/일단위/월단위 유입량을 예측하고 과거 자료와 비교함으로써 검증하였다. 모델의 정확도는 다양한 평가 메트릭(R2, NSE, MAE, PE)이 사용하였으며, SWLSTM은 모든 경우에서 LSTM 모델을 능가하였다. (평가 지표는 약 30 ~ 80 % 더 나은 성능을 보여줌). 본 연구의 결과로부터, 올바른 입력 변수와 시퀀스 길이의 선택이 모델 학습의 효율성을 높이고 노이즈를 줄이는 데 효과적임을 확인하였다. WT는 홍수 첨두와 같은 극단적인 값을 예측하는 데 도움이 된다. k-folds cross validation 및 random search 기법을 사용하면 모델의 하이퍼 매개변수를 효율적으로 설정할 수 있다. 본 연구로부터 댐 유입량을 정확하게 예측한다면 정책 입안자와 운영자가 저수지 운영, 계획 및 관리에 도움이 될 것이다.

  • PDF

A Study on the Regionalization of Rainfall-Runoff Model Considering the Interrelationship between Parameters and Watershed Characteristics (매개변수와 유역특성인자의 상호연관성을 고려한 강우-유출 모형 지역화에 관한 연구)

  • Kim, Jin-Guk;Son, Kyung-Hwan;Hong, Sung-Hoon;Kwon, Hyun-Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.311-311
    • /
    • 2020
  • 가뭄·홍수 등 수재해 대응대책 수립 측면에서 유역의 자연유출량 산정은 가장 핵심적인 사항이라 할 수 있다. 우리나라는 전국적으로 수위-유량관측소를 설치하여 실시간 유출량 모니터링을 통해 수문정보를 수집하며, 주요지점을 제외한 유역에서는 주기적으로 강우-유출모형의 매개변수 최적화를 통해 산정된 장기유출량 결과를 자연유출으로 가정하여 수자원 계획 수립시 활용하고 있다. 그러나 강우-유출모형의 최적 매개변수 추정을 위해 활용되는 관측 수문자료는 상대적으로 자료의 연한이 짧고, 계절·공간적인 특성으로 인해 매우 제한적이며, 유역의 특성을 충분히 고려하지 못해 미계측유역의 매개변수 추정시 모형의 자료에서 기인한 불확실성이 크게 발생한다는 단점이 있다. 이에 본 연구에서는 관측자료에 대한 신뢰성이 유의하며, 공간적으로 고르게 분포된 12개 댐 유역을 대상으로 매개변수 지역화 연구를 수행하였다. SCEM-UA기법을 통해 GR4J 강우-유출모형의 매개변수를 최적화 하였으며, 매개변수와의 상관관계 및 선형회귀분석을 통해 유역특성인자를 선별하여 Copula 함수를 통해 지역화된 매개변수를 추정하였다. 최종적으로 본 연구에서 제시된 방법론에 대한 적합성을 평가하기 위하여 매개변수 최적화가 수행된 유역을 미계측 유역으로 가정하여 교차검증 관점에서 적합성을 검토하였으며, 통계적으로 유의한 결과가 도출되는 것을 확인하였다.

  • PDF

The Study on Effects Caused by the Initial Queue to the Total Delay Estimation in Analyzing Signalized Intersection (신호교차로 분석시 초기대기행렬이 총지체도에 미치는 영향에 관한 연구)

  • Park, Soon-Pyo;Kim, Ki-Hyuk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5D
    • /
    • pp.563-570
    • /
    • 2009
  • This study is aimed to analyze the overall effects of the additional delay caused by the vehicle in front of the queue, at the signal, to the total delay estimation. To estimate the average vehicle delay at the signalized intersection, as survey of the queue length at the intersection and traffic counts were conducted. As a result of this analysis, all of the three delay estimation methods turned out to be similar in that the estimation of the average delay for the test vehicle was less than 60 sec/vehicle. However, the average delay time for the vehicle in front of the queue only, was estimated at 60-70 sec/vehicle which is similar to the average delay of the test vehicle.

Development of hydrological model calibration strategy for Nonstationarity in rainfall-runoff model (강우-유출 모형의 비정상성을 고려한 수문모형 보정 기법 개발)

  • Lee, Ye-Rin;Uranchimeg, Sumiya;Cho, Hemie;Kwon, Hyun-Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.423-423
    • /
    • 2022
  • 수자원 계획 및 관리 관점에 있어 수문모형은 중요한 도구 중 하나이며 모의의 신뢰성을 높이기 위하여 검정 및 보정 과정을 거친다. 이는 일반적으로 장기간의 과거 수문기상자료를 활용하며 자료가 정상성(stationarity)이라는 가정에 따라 매개변수를 산정한다. 그러나 최근 기후변화 문제가 심화되며, 우리나라의 경우 여름철 호우의 강도 및 빈도가 증가할 것으로 전망되는 실정에서 수문 모형의 정상성을 가정한 매개변수 추정은 강우-유출 관계에 왜곡을 초래할 수 있다. 이러한 점에서 수문기상자료의 변동성을 고려한 수문모형의 검정 및 보정기법이 필요할 것으로 판단된다. 본 연구에서는 개념적 강우-유출 모형을 활용하여 산정된 소양강댐의 기존 매개변수와 수문기상자료의 경향성을 비교하여 모형의 적합성 향상 및 다양한 매개변수 산정 방식을 제공하고자 한다. 이를 위해 전역최적화 기법(global optimization method)을 도입하여 매개변수 추정시 발생하는 불확실성을 정량화하였고 동적 기후 예측 매개변수(dynamic climate predictors)를 활용하여 최적화를 수행하였다. 교차검증을 통하여 기존의 매개변수 추정 절차와 비교 검토를 수행하였다.

  • PDF

Comparison of Volumetric Modulated Arc Therapy and Non-coplanar Fixed-field Intensity Modulated Radiation Therapy for Irregular Target adjacent to Organ At Risk (손상위험장기에 인접한 불규칙한 모양의 타겟 치료 시, 용적변조회전 방사선치료와 비동일평면상의 빔을 이용한 세기변조 방사선치료의 유용성 평가 및 비교)

  • Kim, Kyung Ah;Na, Kyung Soo;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.57-68
    • /
    • 2017
  • Purpose: The purpose of this study was to compare volumetric modulated arc therapy(VMAT) with fixed-field intensity modulated radiation therapy(IMRT) using non-coplanar beam when the shape of target is irregular and the location is adjacent to organ at risk(OAR). Materials and Methods: The subjects of this study were a total of 6 patients who had radiation therapy for whole scalp(2 patients), partial scalp(2 patients), and whole ventricle(2 patients) by True Beam STX(Varian Medical Systems, USA). VMAT plans consisted of coplanar or non-coplanar arcs which can minimize the volume of OAR included in beamlets. All fixed-field IMRT plans consisted of non-coplanar beams using more than 2 angles of Couch. Results: The VMAT and IMRT plans were compared with regard to the maximum dose of both lens, both optic nerves, optic chiasm, and brain stem and the mean dose of both eyeballs and hippocampus. VMAT plans showed higher dose than ncIMRT plans at more than 6 of all OARs in every patient, and the ratio was from 1.1 times to 8.2 times. In case of total scalp and partial scalp, the volume of brain which received more than 20 Gy in the VMAT plans was 2 times larger than the volume in the ncIMRT plans. In case of whole ventricle, there was no significant difference. Target coverage was satisfied in both plans($PTV_{100%}=95%$). The maximum dose in target volume and required monitor unit(MU) of ncIMRT were higher than them of VMAT plans. Conclusion: Even though ncIMRT is less efficient than VMAT with regard to required MU and treatment time, the dose to OARs is much lower than VMAT and PTV Coverage is similar with VMAT. If the shape of target is irregular and location is adjacent to OAR, comparison VMAT plan with ncIMRT plan deserves to be considered.

  • PDF

Evaluating efficiency of Vertical MLC VMAT plan for naso-pharyngeal carcinoma (비인두암 Vertical MLC VMAT plan 유용성 평가)

  • Chae, Seung Hoon;Son, Sang Jun;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.127-135
    • /
    • 2021
  • Purpose : The purpose of the study is to evaluate the efficiency of Vertical MLC VMAT plan(VMV plan) Using 273° and 350° collimator angle compare to Complemental MLC VMAT plan(CMV plan) using 20° and 340° collimator angle for nasopharyngeal carcinoma. Materials & Methods : Thirty patients treated for nasopharyngeal carcinoma with the VMAT technique were retrospectively selected. Those cases were planned by Eclipse, PO and AcurosXB Algorithm with two 6MV 360° arcs and Each arc has 273° and 350° of collimator angle. The Complemental MLC VMAT plans are based on existing treatment plans. Those plans have the same parameters of existing treatment plans but collimator angle. For dosimetric evaluation, the dose-volumetric(DV) parameters of the planning target volume (PTV) and organs at risk (OARs) were calculated for all VMAT plans. MCSv(Modulation complexity score of VMAT), MU and treatment time were also compared. In addition, Pearson's correlation analysis was performed to confirm whether there was a correlation between the difference in the MCSv and the difference in each evaluation index of the two treatment plans. Result : In the case of PTV evaluation index, the CI of PTV_67.5 was improved by 3.76% in the VMV Plan, then for OAR, the dose reduction effect of the spinal cord (-14.05%) and brain stem (-9.34%) was remarkable. In addition, the parotid glands (left parotid : -5.38%, right : -5.97%) and visual organs (left optic nerve: -4.88%, right optic nerve: -5.80%, optic chiasm : -6.12%, left lens: -6.12%, right lens: -5.26%), auditory organs (left: -11.74%, right: -12.31%) and thyroid gland (-2.02%) were also confirmed. The difference in MCSv of the two treatment plans showed a significant negative (-) correlation with the difference in CI (r=-0.55) of PTV_54 and the difference in CI (r=-0.43) of PTV_48. Spinal cord (r=0.40), brain stem (r=0.34), and both salivary glands (left: r=0.36, right: r=0.37) showed a positive (+) correlation. (For all the values, p<.05) Conclusion : Compared to the CMV plan, the VMV plan is considered to be helpful in improving the quality of the treatment plan by allowing the MLC to be modulated more efficiently

Development of Traffic Accident Prediction Models by Traffic and Road Characteristics in Urban Areas (도로 및 교통특성에 따른 계획 단계의 도시부 도로 교통사고 예측모형개발)

  • 이수범;김정현;김태희
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.4
    • /
    • pp.133-144
    • /
    • 2003
  • The current procedure of estimating accident reduction benefit shows fixed accident rates for each level of roads without considering the various characteristics of roadway geometries, and traffics. In this study, in order to solve the problems mentioned in the above, models were developed considering the characteristics of roadway alignments and traffic characteristics. The developed models can be used to estimate the accident rates on new or improved roads, In this study, only urban highways were included as a beginning stage. First of all. factors influencing accident rates were selected. Those factors such as traffic volumes. number of signalized intersections, the number of connecting roads, number of pedestrian traffic signals, existence of median barrier, and the number of road lane are also selected based upon the obtainability at the planning stage of roads. The relationship between the selected factors and accident rates shows strong correlation statistically. In this study, roads were classified into 4 groups based on number of lanes, level of roads and the existence of median barriers. The regression analysis had been performed for each group with actual data associated with traffic, roads. and accidents. The developed regression models were verified with another data set. In this study, in order to develop the proposed models, only data on a limited area were used. In order to represent whole area of the country with the developed models. the models should be re-analyzed with vast data.

Incase of Same Region Treatment by using a Tomotherapy and a Linear Accelerator Absorbed Dose Evaluation of Normal Tissues and a Tumor (토모테라피와 선형가속기를 이용한 동일 부위의 치료 시 종양 및 정상조직의 흡수선량 평가)

  • Cheon, Geum-Seong;Kim, Chang-Uk;Kim, Hoi-Nam;Heo, Gyeong-Hun;Song, Jin-Ho;Hong, Joo-Yeong;Jeong, Jae-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.97-103
    • /
    • 2010
  • Purpose: Treating same region with different modalities there is a limit to evaluate the total absorbed dose of normal tissues. The reason is that it does not support to communication each modalities yet. In this article, it evaluates absorbed dose of the patients who had been treated same region by a tomotherapy and a linear accelerator. Materials and Methods: After reconstructing anatomic structure with a anthropomorphic phantom, administrate 45 Gy to a tumor in linac plan system as well as prescribe 15 Gy in tomotherapy plan system for make an ideal treatment plan. After the plan which made by tomoplan system transfers to the oncentra plan system for reproduce plan under the same condition and realize total treatment plan with summation 45 Gy linac treatment plan. To evaluate the absorbed dose of two different modalities, do a comparative study both a simple summation dose values and integration dose values. Then compare and analyze absorbed dose of normal tissues and a tumor with the patients who had been exposured radiation by above two differents modalities. Results: The result of compared data, in case of minimum dose, there are big different dose values in spleen (12.4%). On the other hand, in case of the maximum dose, it reports big different in a small bowel (10.2%) and a cord (5.8%) in head & neck cancer patients, there presents that oral (20.3%), right lens (7.7%) in minimum dose value. About maximum dose, it represents that spinal (22.5), brain stem (12%), optic chiasm (8.9%), Rt lens (11.5%), mandible (8.1%), pituitary gland (6.2%). In case of Rt abdominal cancer patients, there represents big different minimum dose as Lt kidney (20.3%), stomach (8.1%) about pelvic cancer patients, it reports there are big different in minimum dose as a bladder (15.2%) as well as big different value in maximum dose as a small bowel (5.6%), a bladder (5.5%) in addition, making treatment plan it is able us to get. Conclusion: In case of comparing both simple summation absorbed dose and integration absorbed dose, the minimum dose are represented higher as well as the maximum dose come out lower and the average dose are revealed similar with our expected values data. It is able to evaluate tumor & normal tissue absorbed dose which could had been not realized by treatment plan system. The DVH of interesting region are prescribed lower dose than expected. From now on, it needs to develop the new modality which are able to realize exact dose distribution as well as integration absorbed dose evaluation in same treatment region with different modalities.

  • PDF

휴대형 당도판정센서를 이용한 배의 당도 판정

  • 이강진;최규홍;강석원;최완규;손재룡
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.04a
    • /
    • pp.120-121
    • /
    • 2003
  • 과수원에서 재배되는 배는 과수원 내의 위치, 시비, 토양 등의 요인에 따라 다양한 품질을 나타내며, 당도와 숙도의 편차가 크기 때문에 과수농가에서는 경험에 의존하여 적정 숙기로 판단되는 배를 수확하고 있다. 그러나 과학적이지 못한 사실에 기초한 수확 관행은 시장유통되는 배에 대하여 소비자들의 신뢰성 저하를 초래하게 되고 소비 감소와 더불어 농가 소득 감소로 이어지게 된다. 최근, 전국의 청과물 산지유통센터에는 근적외선을 이용하여 과일 내부의 당도, 산도, 결함 등을 실시간으로 판정할 수 있는 비파괴 선별기가 보급되고 있으나 이는 수확이후의 선별.규격화 유통을 위한 것이다. 본 연구에서는 이와는 달리, 수확 이전, 즉 재배 단계에서 배의 당도와 숙도를 판정하여 수확적기를 판단할 수 있도록 나무에 매달린 배에 대하여 가시광선과 근적외선 반사스펙트럼을 측정할 수 있고 이를 이용하여 당도와 숙도가 판정가능한 휴대형 센서를 개발하였으며, 개발된 시작기를 이용하여 당도판정의 가능성을 시험하였다. 휴대형 당도판정센서는 광원과 광섬유프로브, 광검출부, 당도판정부, 전원공급부로 구성된다. 광원은 할로겐램프(6V)를 이용하였고, 광섬유프로브는 동심원 형태로서 외부의 광섬유를 통하여 광원에서 시료로 빛이 조사되게 하고, 내부의 광섬유를 통하여 광검출기로 확산반사되는 광이 전달될 수 있도록 하였다. 전원공급부는 휴대와 충전이 가능한 배터리(12V, 2AH)와 이 배터리에서 정전류가 광원으로 보내어 질 수 있도록 제작된 회로로 구성하였다. 당도 판정을 위하여 518nm에서 1046nm의 파장대역에서의 반사스펙트럼을 이용하였고, 레퍼런스로써 백색 테플론 구를 제작하여 사용하였다. 수원 농산물 도매시장에서 판매중인 2002년산 신고 배를 구매하고, 시작기를 이용하여 총 113개의 배에 대한 반사스펙트럼을 측정하였다. 다음으로 굴절당도계로 당도값을 측정하고 반사스펙트림을 이용하여 당도값을 예측하기 위한 부분최소제곱회귀(PLSR)모델을 개발하였다. 여기서 모델의 정밀도는 교차검정법을 이용하여 검증하였다. 시료 표면과 광섬유프로브와의 접촉상태 불균일, 광원의 시간에 따른 경시 변화, 과일 형상의 차이 등에 의하여 측정된 반사스펙트럼은 상당한 변이를 나타내었으므로 이를 보정하기 위하여 반사 스펙트럼은 다분산보정처리하여 이용하였다. 당도 예측용 PLSR모델 개발의 결과, 모델의 결정계수($R^2$)는 0.67, SEC는 $\pm$0.4brix.로 나타났으며, 교차검정에 의한 미지 시료의 예측에서 총 113개의 미지 시료에 대한 결정계수는 0.57, SEP는 $\pm$ 0.46brix.로 나타났으며, 이는 현장에서 충분히 활용가능할 것으로 판단되었다. 금후, 전체 시스템의 부피와 중량을 줄이고 각 부분품들의 전력소모의 최소화할 수 있도록 개선할 계획이다.

  • PDF