• Title/Summary/Keyword: 교정용 호선

Search Result 23, Processing Time 0.026 seconds

Bending Optimization of Archwire for Orthodontics Considering the Nonlinearity of Periodontal Ligament (치주인대의 비선형성을 고려한 치아 교정용 호선의 굽힘 최적화)

  • Heo, Ji-In;Lee, Kwon-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.6
    • /
    • pp.77-83
    • /
    • 2013
  • Orthodontics is a branch of dentistry that is concerned with the study and treatment of malocclusion, which may result from tooth irregularities, disproportionate jaw relationships, or both. Orthodontic devices consist of brackets, archwire connected to each bracket, and bends and hooks for auxiliary functions. Basically, orthodontics involves the interaction of brackets and archwire. It should be noted that uncontrolled tipping can occur due to unwanted movement of the teeth. The bending of an archwire can control the angle of an archwire and the rotation of a tooth. In this study, we predict the relationship between the bending angle of an archwire and the rotation of a tooth using the Kriging interpolation method. Also, we calculate the angle of an archwire that occurs at the minimum value of tooth rotation.

Comparison of finite element analysis of the closing patterns between first and second premolar extraction spaces (상악 제1 및 제2소구치의 발치공간 폐쇄기전에 대한 3차원 유한요소 해석의 비교 연구)

  • Koh, Shin-Ae;Im, Won-Hee;Park, Sun-Hyung;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.407-420
    • /
    • 2007
  • The aim of this study was to compare the differences in closing extraction spaces between maxillary first premolar and second premolar extractions using 3-dimensional finite element analysis (FEA). Methods: Maxillary artificial teeth were selected according to Wheeler's dental anatomy. The size and shape of each tooth, bracket and archwire were made from captured real images by a 3D laser scanner and FEA was performed with a 10-noded tetrahedron. A $10^{\circ}$ gable bend was placed behind the bull loop on a $0.017"{\times}0.025"$ archwire. The extraction space was then closed through 12 repeated activating processes for each 2mm of space. Results and Conclusions: The study demonstrated that the retraction of anterior teeth was less for the second premolar extraction than for the first premolar extraction. The anterior teeth showed a controlled tipping movement with slight extrusion, and the posterior teeth showed a mesial-in rotational movement. For the second premolar extraction, buccal movement of posterior teeth was highly increased.

TREATMENT OF THE IMPACTED LOWER SECOND MOLARS (매복된 하악 제2대구치 맹출유도의 치험례)

  • Hahn, Soo-Kyoung;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.41-45
    • /
    • 2004
  • In the normal growth and development of the mandible, the molar tooth buds distal to the first permanent molar have a mesial inclination. This inclination is usually self-correcting, but, unfortunately, this self-correction does not always occur. The first case is about, 14-year-old female patient with familial history of lower second molar impaction. Her lower second molars were both impacted, and she was treated with sectional wires and open-coil springs. The second case, 14-year-old male, we treated his impacted #47 with Halterman appliance. The third case, 11-year-old male, his both mandibular second molars were impacted during full-fixed orthodontic treatment. They were treated with brass wire, sectional wire and open-coil spring.

  • PDF

A STUDY OF HOLOGRAPHIC INTERFEROMETRY ON THE INITIAL REACTION OF MAXILLOFACIAL COMPLEX TO THE INTERMAXILLARY FORCES ON THE ORTHODONTIC ARCHWIRES (교정용 호선에 악간 교정력 적용시 악안면골의 초기반응에 관한 Holographic Interferometry 연구)

  • Jin, Ik-Jae;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.24 no.2
    • /
    • pp.447-476
    • /
    • 1994
  • This study was performed to evaluate the initial reaction of maxillofacial complex to the Class II intermaxillary and the anterior vertical elastic forces on the six types of archwires including multiloop edgewise arch wires(MEAW). A human dry skull was used for this purpose and this investigation was done by holographic interferometry. Based on such investigation, the fringe pattern and the number of fringes of each condition were compared and analyzed. The findings of this study were as follows: 1. As the orthodontic forces increased, the amount of displacement increased. 2. As the orthodontic forces were applied, the fringes were shown not only in the teeth and the maxilla but also in the adjacent bones, i.e., temporal bone, zygomatic bone, nasal bone, frontal bone and sphenoid bone. And the direction of fringe pattern and the number of fringes were different from each other by the sutures. 3. As the long Class II elastic forces were applied, the backward-downward displacements of the anterior teeth and the maxilla were shown, and backward displacement of the former were grater than those of the latter. And backward displacements were greater by the long Class II elastic forces than by the short Class II elastic forces. 4. As the anterior vertical elastic forces were applied, downward displacements of the anterior teeth and the maxilla were shown, and the downward displacements of the former were greater than those of the latter relatively. 5. The downward displacements of the anterior area to the anterior vertical elastic forces of the MEAW were greater than those of other archwires. In addition, the more tip-back bend was applied, the more displacement was seen. 6. As the Class II intermaxillary forces and the enough anterior vertical elastic forces were applied on the MEAW with tip-back bend, there was an intrusive effect of the posterior teeth.

  • PDF

Torsional moment of orthodontic wires (교정용 와이어의 비틀림 모멘트)

  • Choy, Kwangchul;Kim, Kyung-Ho;Park, Young-Chel;Kang, Chang-Soo
    • The korean journal of orthodontics
    • /
    • v.30 no.4 s.81
    • /
    • pp.467-473
    • /
    • 2000
  • As a rectangular wire Is inserted into edgewise brackets the wire exerts a force system three-dimensionally. The force system may include bending force in first and second orders and a torsional force in third order Analytical and experimental studies on bending force have been Introduced, but information about torsion is still lack. The purpose of this study was to estimate the torsional moment in the force system of rectangular arch wires through theoretical and experimental studies. Wires most frequently used for third order control were selected as study materials. Cross sections of 0.016x0.022, 0.017x0.025, 0.019x0.025 inch rectangular wires in foot different materials such as stainless steel(Ormco), TMA(Ormco), NiTi(Ormco), and braided stainless steel (DentaFlex, Dentaurum) were used. The torque/twist rate of each test material was calculated using the torsion formula. Torque/twist rate, yield torsional moment, and ultimate torsional moment were measured with a torque gauge. The torsion formula assesses that the torque/twist rate (T/$\theta$) is proportional to the characteristics of material (G) and cross section (J), and is inversely proportional to the length of wire (L). Most experimental results corresponded with the formula. The relative stiffness was calculated for reference to a logical sequence of wire changes.

  • PDF

A prospective clinical trial to compare the performance of four initial orthodontic archwires (교정치료 초기에 사용되는 4가지 호선의 초기 치료효과를 비교하기 위한 전향적 임상 실험 연구)

  • Quintao, Catia C. A.;Jones, Malcoim L.;Menezes, Luciane M.;Koo, Daniel;Elias, Carlos N.
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.381-387
    • /
    • 2005
  • The aim of this study was to compare the clinical performance of 4 types of orthodontic wires, indicated for initial tooth alignment: stainless steel, multistranded steel, superelastic and thermoactivated nickel-titanium. A prospective randomized clinical trial was conducted on a sample of 45 patients, at the Dental School of the State University of Rio do Janeiro, Brazil. Fixed appliances were fitted and study casts were obtained from each patient. Randomly, the wires were allocated as follows: 26 dental arches for superelastic NiTi wires, 22 for stainless steel, 22 for multistranded and 20 for thermoactivated archwires. After 8 weeks, the archwires were removed and impressions for study casts were taken again. Using a 3D digitization technique of defined anatomical points on the study cast crowns, a Dental Irregularity Index (DII) was created for each study cast. The difference between DII before and after the archwire insertion expressed the aligning effect of the wires. ANOVA tests were employed to evaluate the anatomical point approximation (positive DII) and separation (negative DII), for each area of the dental arches: upper and lower whole arch and anterior arch. Results showed no significant difference between the different archwires.

An experimental study of dynamic frictional resistance between orthodontic bracket and arch wire (교정용 브라켓과 강선 사이의 운동마찰저항력에 관한 실험적 연구)

  • Lee, Jae-Hwan;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.31 no.4 s.87
    • /
    • pp.467-477
    • /
    • 2001
  • This investigation was designed to determine the effects of wire size, bracket width and the number of bracket on bracket-wire dynamic frictional resistance during simulating arch wire-guided tooth movement in vitro. For simulation of an arch wire-guided tooth movement, we simulated tooth, periodontal ligament and cancellous bone. Maxillary premolar and 1st molar were simulated as real sized resin teeth, the simulated resin teeth which its root was coated by polyether impression material which its elastic modulus is similar to periodontal ligament were embedded in steel housing with inlay wax which its elastic modulus is similar to cancellous bone. Stainless steel wires in four wire size (0.016, 0.018, $0.016\;{\times}\;0.022,\;0.019\;{\times}\;0.025$ inch) were examined with respect to three (stainless steel) bracket widths (2.4, 3.0, 4.3mm) and the number of medium bracket(one, two, three) included in the experimental assembly under dry condition. The wires were ligated into the brackets with elastomeric module. The results were as follows : 1. In all the brackets, frictional resistance increased with increase in wire size. But, statistically similar levels of frictional resistance were observed between 0.018 inch and $0.016\;{\times}\;0.022$ inch wires in narrow bracket and also between 0.016 inch and 0.018 inch wire in wide backet. 2. The frictional forces produced by 0.016 inch wire were statistically similar levels in all the brackets. In 0.018 inch round wire, wide bracket was associated with lower amounts of friction than both narrow and medium brackets. In $0.016\;{\times}\;0.022,\;0.019\;{\times}\;0.025$ inch rectangular wire, wide bracket produced target friction than both narrow and medium brackets. In all the wirer, narrow and medium bracket demonstrated no statistical difference in levels of frictional resistance. 3. Frictional resistance increased with increase In number of medium bracket. 0.016 inch round wire demonstrated the greatest increment in frictional resistance, followed by $0.019\;{\times}\;0.025,\;0.016\;{\times}\;0.022$ inch rectangular wire which were similar level in increment of frictional resistance, 0.018 inch wire demonstrated the least increment. The increments of frictional resistance were not constantly direct proportion to number of bracket.

  • PDF

Spatial changes of the upper dentition following en-masse space closure: A comparison between first and second premolar extraction (En-masse 견인에 의한 발치공간 폐쇄 후 상악치열의 이동양상 -제1소구치 및 제2소구치 발치 비교)

  • Kim, Hui-Jung;Chun, Youn-Sic;Jung, Sang-Hyuk
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.371-380
    • /
    • 2005
  • The purpose of this experimental study was to evaluate aㅜd compare maxillary arch dimensional and positional changes between first and second premolar extraction groups. The Calorific Machine was used to illustrate tooth movement in three dimensions. The experimental teeth except the first or second premolars were embedded in artifical alveolar bone. The extraction space was closed using arch wires with bull loops into which 15 degree gable bends were placed. Before and after space closure, radiographs were taken in the sagittal and occlusal directions using occlusal films. The results showed greater mean maxillary incisor retraction and less anchorage loss in the maxillary first premolar extraction group than in the maxillary second premolar extraction group. Mesiopalatal rotation of anchor teeth was greater after extraction of a maxillary second premolar than a maxillary first premolar (P<.001).

A photoelastic study on the initial stress distribution of the upper anterior teeth retraction using combination loop archwire and sliding mechanics (Combination loon archwire와 활주역학을 이용한 상악전치의 후방 견인시 나타나는 초기 응력 분포에 관한 광탄성학적 연구)

  • Yim, Kang-Soon;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.303-312
    • /
    • 2004
  • An unfavorable tipping movement can occur during the retraction of anterior teeth because orthodontic force is loaded by brackets positioned far from the center of resistance. To avoid this unfavorable movement, a compensating curved wire or lingual root torque wire is used. The purpose of this study is to investigate, using photoelastic material, the distribution of initial stress associated with the retraction of the incisors according to the degree of the compensating curve, to model changes associated with tooth ud alveolar bone structure. The following results were obtained by analysis of the polarizing plate of the effects of initial stress resulting from retraction of the anterior teeth: 1. When the incisors were retracted using combination archwire or sliding mechanics, the maximal polarizing pattern of the apical area decreased as the degree of the compensating owe increased from 0 to 15 to 30. 2. When the incisors were retracted by the combination archwire or sliding mechanics, the maximal polarizing pattern of the canine and premolar area increased as the degree of the compensating curve increased from 0to 15to 30. 3. A lower degree of polarizing patterns were associated with the combination archwire technique than the sliding mechanics technique at a given force. The above results indicate that there is no significant difference between the combination loop archwire technique and sliding mechanics, for the retraction of maxillary anterior teeth with decreased lingual tipping tendency by a compensating curve on the arch wire. However, the use of sliding mechanics is more effective for the prevention of lingual inclination of the anterior teeth, because the hook used in sliding mechanics is closer to the center of resistance of the maxillary anterior teeth.

Methodological Issues in Socio-Economic Assessment of the Hydrogen Economy Development (수소경제로 이행을 위한 사회경제적 영향평가 방법론)

  • Kim, Ho-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.586-591
    • /
    • 2005
  • 우리나라는 에너지의 안정적 공급과 에너지이용 과정에서 발생하는 환경적, 안보적 외부성을 최소화하는 에너지수급 구조를 마련하기 위해 2003년 12월 '제2차 신재생에너지 기술개발 및 이용보급 기본계획(2003-2012)'을 발표하였다. 이 계획에서는 2011년까지 전체 TPES의 $5\%$를 신재생에너지로 공급하는 것을 정책목표로 수립하고 수소, 태양광 그리고 풍력기술을 중점적으로 추진하기로 하였다. 특히 수소부문에서는 주택 및 건물용, 발전용, 수송용 연료전지의 개발을 중심으로 개발하여 세계 기술시장의 $20\%$를 확보한다는 계획을 발표하였다. 이러한 기술 잠재력을 기반으로 우리 정부도 미국이나 일본과 같이 수소경제로의 전환을 준비하고 있으며 2020년대 이후 우리나라의 에너지부문은 새로운 국면에 접어들 것으로 전망된다. 에너지나 환경기술의 효과적 인 개발을 위해서는 이들 기술의 직접적인 비용측면에 대한 분석 즉 경제성 평가와 새로운 기술변화로 인한 중장기적인 사회경제적 영향평가가 선행되어야 한다. 이러한 평가는 대상 기술의 사회경제적 파급효과가 광범위할수록 더욱 복잡한 분석이 요구된다. 본 연구의 주제인 수소에너지기술은 지금까지 이용되던 것과는 전혀 새로운 에너지캐리어(carrier)를 개발하는 것으로 에너지부문 및 여타 다른 산업부문이 공유하고 있는 에너지 관련 인프라의 전면적인 조정이 요구되며 에너지 이용과 관련된 사회경제적 측면의 급속한 변화를 수반한다. 본 연구는 수소경제로의 이행에 대한 사회경제적 영향평가의 방법론적 요소들과 기법을 제시한다."중등도 독성"으로 나타났다 이상의 결과는 전기도금을 이용하여 교정용 선재의 직경을 증가시키는 방법이 임상에 적용되기 위해서는 세포독성을 줄이기 위한 추가의 연구가 필요함을 시사하였다.의하게 가장 낮은 정지. 운동 마찰력을 보였고 브라켓-호선 각도가 증가함에 따라 유의하게 정지, 운동 마찰력도 증가하였다 (P<0.001)%$ 낮추지만(p value=0.260) 평균 $D_{max}$는 거의동일 하여($0.3\%$ 감소, p value=0.867), 전통적인 방법보다 우수성이 크게는 없는 것으로 평가되었다. 그러나 환자의 체곡선이 보상체와 잘 일치하는 경우에는 DII가 $18\%$까지 감소하였다. 결론 : Multistatic field 방법은 모든 환자에 대하여 선량분포의 균일성을 전반적으로 향상시키는 효과적인 방법으로 평가되는 반면 공용보상체의 사용은 보상체의 크기가 환자의 체 윤곽과 잘 일치하는 경우만 효과적으로, 적용의 범위에는 한계가 있는 방법으로 평가되었다.비교하여 계통에 따르는 차이가 있음을 알 수 있었다. 그러므로 가임기 여성의 방사선 진단 및 치료시 Rugh의 10일 법칙을 적용하여 착상전기 방사선 조사로 인한 부작용들을 적극적으로 예방하는 것이 매우 중요하다고 생각한다.equirements of the prematured infants during the early weeks of life. 모든 치근단 수준에서 비표준화 medium 크기 master cone 사용군이 ISO 표준화 규격의 master cone 사용군에 비해

  • PDF