• Title/Summary/Keyword: 교정기구

Search Result 97, Processing Time 0.028 seconds

SI-traceable Calibration of a Transmissometer for Meteorological Optical Range (MOR) Observation (기상관측용 투과형 시정계의 국제단위계에 소급하는 교정)

  • Park, Seongchong;Lee, Dong-Hoon;Kim, Yong-Gyoo
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.2
    • /
    • pp.73-82
    • /
    • 2015
  • This work demonstrates the indoor SI-traceable calibration of a transmissometer with a 75-m baseline for the measurement of visibility in MOR (Meteorological Optical Range). The calibration is performed using a set of neutral density (ND) filters (OD 0.1-2.5) and a set of high-transmission quartz glass plates (a bare quartz glass plate and antireflective-coated quartz glass plates), the collection consisting of 20 artifacts in total. The luminous transmittance values of the reference artifacts had been calibrated traceable to the KRISS spectral transmittance scale, which ranges from 0.2 % to 99.5 %. The transmissometer to be calibrated typically consists of a loosely collimated light source based on a white LED (CCT ~5000 K) and a luminous intensity detector with a CIE 1924 V(${\lambda}$) spectral response. As a result of calibration, we obtained the MOR error and its uncertainty for the transmissometer in 20 m - 40 km of MOR. Based on the results, we investigated the applicability of the calibration method and the conformity of the transmissometer to the ICAO's (International Civil Aviation Organization) accuracy requirement for meteorological visibility measurement. We expect that this work will establish the standard procedure for the SI-traceable calibration of a transmissometer.

Uncertainty Analysis of Spinning Rotor Gauge Calibrated by High Vacuum Standard of Static Expansion Method (정적법 고진공표준기에 의해 교정한 스피닝 로터 게이지 불확도 평가)

  • Hong S. S.;Lim I. T.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.186-194
    • /
    • 2005
  • A Spinning Rotor Gauge was calibrated between $4.04\times10^{-3}$ Pa and $1.11\times10^{-2}$ Pa at the high vacuum standard by static expansion method. The results were analysed according to the document of 'Guide to the Expression of Uncertainty in Measurement' of ISO. The expanded uncertainty was $3.0035\times10^{-3}$ Pa at $7.5448\times10^{-3}$ Pa. $95\%$ confidence level, and coverage factor of k = 1.

Analysis of Characteristics of Medical Accidents and Disputes in Orthodontic Area (교정과영역의 의료사고 및 분쟁의 성격분석)

  • Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.29 no.1 s.72
    • /
    • pp.1-22
    • /
    • 1999
  • As people are more concerned about their health and medical care, there have been an increasing number of medical disputes due to increased medical demand. In order to prevent and provide solution to currently surging medical accidents and disputes related to orthodontic treatment, in July 1998, the Korean Association Of Orthdontists surveyed 2,200 members of Korean Association of orthodontists on 30 items to recognize the pattern of medical accidents and prevent them. The survey was about accident-related items including personal profiles of members and patients who have undergone medical accidents or disputes, the cause and solution to the accidents, cautions related to members orthodontic treatment, and medical recording and archival. Based on the survey result, we analyzed characteristics of medical accidents and disputes in orthodontic area. It is more important to predict and prevent possible medical accidents or disputes based on current situation than to solve them after disputes occur. For this, we should not be negligent in raising treatment proficiency level based on patient-doctor trust and in obtaining new medical information. We should also provide medical environment where Patients themselves can decide whether to get treatment after they are offered detailed explanation on diagnosis, treatment procedure, complication, and possible hazard. We should take caution when treating patients and pay attention to charting and maintenance, which is the most fundamental, as well. Also at the Korean Association of orthodontists level, it is desired to provide education program on prevention and solution to medical accidents and disputes, and actions and organizations that can help when accidents and disputes occur.

  • PDF

Development of a Dose Calibration Program Based on an Absorbed Dose-to-Water Standard (물 흡수선량 표준에 기반한 선량교정 프로그램 개발)

  • 신동오;김성훈;박성용;서원섭;이창건;최진호;전하정;안희경;강진오
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.175-183
    • /
    • 2003
  • Absorbed dose dosimetry protocols of high energy photon and electron beams, which are widely used and based on an air kerma (or exposure) calibration factors, have somewhat complex formalism and limitations for improving dosimetric accuracy due to the uncertainty of the physical parameters used. Recently, the IAEA and the AAPM published the absorbed dose to water-based dosimetry protocols(IAEA TRS-398 and AAPM TG-51). The dose calibration programs for these two protocols were developed. This program for high energy photon and electron beams was also developed for users to use in a window environment using the Visual C++ language. The formalism and physical parameters of these two protocols were strictly applied to the program. The tables and graphs of the physical data, and the information of ion chambers were numericalized for their incorporation into a database. This program can be useful in developing new dosimetry protocols in Korea.

  • PDF

A Review of Milking Preparation: The Science. (착유준비의 재 검토 : 과학적인 면에서)

  • 손봉환
    • Journal of the korean veterinary medical association
    • /
    • v.37 no.10
    • /
    • pp.949-954
    • /
    • 2001
  • 착유효과는 시간 당 소에 대한 일정한 일을 주로 측정하는 것이다. 그러나 시간 당 착유우유 kg에서 일정한 일의 양 또는 시간 당 더 좋은 우유 kg까지가 바라는 것이다. 소/시간에 대한 초점은 착유 전 유두준비에 소비시간을 감소 시키는 것이다. 그리고 이 검토는 우유생산, 안정된 우유흐름에 대한 시간, 유질과 유방건강에 중점을 둔 것이다. 우유의 질이나 유방염에 대하여 착유준비는 대단히 중요하다. 우리는 권장된 기준에 맞추어 착유준비를 하고 있는가? 스스로 검토하여 보아야 한다. 또한 그 기준에 정확히 따라서 함은 물론이고, 필요한 기구와 약제의 사용에도 하자가 없는지 재 확인하여 보아야 한다 그렇지 안으면 자기의 책임을 다른 곳에 돌리고 실제작업의 교정에는 실패를 하는 경우가 될 것이다.

  • PDF

Proficiency Test of Water Flow Rate for Measurement Equivalence Among KOLAS Accredited Laboratories (KOLAS 교정기관의 측정동등성 확립을 위한 물유량 숙련도 시험)

  • Chun, Sejong;Yoon, Byung-Ro;Kim, Soo-Jin
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.105-113
    • /
    • 2017
  • KOLAS (KOrea Laboratory Accreditation Scheme) belongs to APLAC (Asia Pacific Laboratory Accreditation Cooperation). KOLAS manages the accreditation scheme for measurement traceability to SI units. As per June 2016, there are 22 KOLAS laboratories for liquid flow metering. Among them, 12 laboratories participated in the proficiency test (PM2015-08) for water flow metering, organized by KASTO (Korea Association of Standards and Testing Organizations). This proficiency test was performed with three kinds of flow ranges ($3.6m^3/h{\sim}12m^3/h$, $40m^3/h{\sim}80m^3/h$, $40m^3/h{\sim}200m^3/h$) considering the CMC (calibration and measurement capability) of the participating laboratories. The purpose of the proficiency test was to find out measurement equivalence of the CMC's between each participating laboratory and the reference testing laboratory (KRISS). The measurement equivalence was tested by the number of equivalence ($E_n$). If ${\mid}E_n{\mid}$ < 1, the measurement equivalence was established. All the participating laboratories passed this proficiency test.

Contact lens Prescription and Satisfaction with Astigmatism Eye (난시안의 콘택트렌즈 처방과 만족도에 관한 연구)

  • Kim, Mi-Yeon;Kim, Yeong-Mi;Kim, Tae-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.317-322
    • /
    • 2006
  • For this study we made up a question investigation to analyze a grade of satisfaction and a side effect about the prescription actual condition of contact lens of person with astigmatism among the person who has a error of refraction. The whole patient of refractive error was 46 person, there were 11 person who only wear spectacles by correction of visual acuity among person to a question investigation and 35 person who only wear contact lens. Under investigation 35 person who only wear contact lens, there were 25 person who experience the problem which occurs because of contact lens wearing for a long time. The most patient who made up a question investigation very choose remainder item except for item of very satisfaction. The their reason that could not satisfaction was non corrected astigmatism, wrong prescription, wrong Base curve, out of life span etc.

  • PDF

Low vacuum characteristics of the capacitance diaphragm gauges and the resonance silicon gauges (용량형 격막식 게이지와 공진형 실리콘 게이지의 저진공 특성)

  • ;;;I. Arakawa
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.3
    • /
    • pp.151-156
    • /
    • 2003
  • Two capacitance diaphragm gauges(CDG) and two resonance silicon gauges(RSG) were calibrated using an ultrasonic interferometer as a national low vacuum standard in KRISS. The CDG has superior pressure resolution and is rugged as well as resistant to over-pressure because of all-metal inner components. Meanwhile, the RSG is a new type of MEMS sensor that has excellent calibration stability and is resistant to mechanical shocks. The calibration uncertainties were analyzed according to the ISO procedures. Results showed that the maximum difference of the expanded uncertainties was $9\times10^{-3}$Pa at the generated pressure of 100 Pa for the two different types. It is remarkable that the RSG can be used as a transfer standard at low vacuum since their accuracies were found to be within 0.5 %.

Robotic Assisted Surgery in Adult Patient with Congenital Ventricular Septal Defect (내시경 수술 보조 로봇을 이용한 성인 심실중격결손 교정술)

  • Park, Il;Lee, Jong-Tae;Kim, Gun-Jik;Cho, Joon-Yong
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.931-933
    • /
    • 2006
  • Robotic assisted surgery in adult patient with congenital ventricular septal defect Since December in 2005, we have done minimally invasive surgeries in selected cases of mitral valve diseases, tricuspid valve diseases, atrial septal defects and atrial fibrillations with the $AESOP^{TM}$ robotic arm. We have had a better surgical view and skill, according to accumulation of the experience of this procedure. Recently, we performed robotic assisted surgery in a 47-year-old female with congenital perimembranous ventricular septal defect.

The Bacterial Contamination in Glasses for Vision Correction (시력 교정용 안경의 세균 오염)

  • Kim, Heung-Soo;Hwang, Seock-Yeon;Yun, Chi-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.67-73
    • /
    • 2013
  • Purpose: Recently, bacterial contamination of equipment and accessories required for vision correction has become a main causal factor in ophthalmic diseases. Thus, We investigated on both the actual condition of bacterial contamination from glasses of vision correction. Methods: Investigation of microorganisms was carried out with a group of 145 glasses wearers, composed of 36 elementary school students, 37 middle school students, 38 high school students, 10 college students, and 32 aged men. Results: Seventeen species of bacteria are detected from glasses of vision correction: B. cereus, B. licheniformis, Bacillus sp., CNS, Enterococcus sp., Escherichia coli, Proteus sp., Pseudomonas sp., Serretia sp., Streptococcus sp., Staphylococcus epidermidis, Staphylococcus aureus, Streptococcus hemolyticus,, Acinetobacter sp., Enterobacter cloacae, GNR, and Pseudomonas aeruginosa. Among 17 species of bacteria, there are some potential causative agents for keratitis, corneal ulcer, Acute dacryocystitis, Orbital cellulitis, Periphlebitis retinae, Marginal blepharitis, and Acute conjunctivitis. Enterobacter cloacae, Pseudomonas aeruginosa and Staphylococcus epidermidis cause keratitis. Pseudomonas sp., and Staphylococcus aureus cause corneal ulcer. Staphylococcus aureus causes acute dacryocystitis, orbital cellulitis, periphlebitis retinae, marginal belpharitis. Streptococcus hemolyticus causes acute conjunctivitis. Conclusions: In summation, it is verified that hazardous, opportunistic and infectious microorganisms exist in glasses for vision correction. Ophthalmic diseases are predicted. Therefore, supplementary research on the development of a cleaning solution to cleanse the infection and of an effective method to remove microorganisms is required.