• Title/Summary/Keyword: 교정굴절력

Search Result 76, Processing Time 0.017 seconds

Correlation between Anterior and Posterior Corneal Astigmatism in Total Corneal Astigmatism (전체 각막난시에서 전면과 후면 각막난시의 상관성)

  • Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.377-382
    • /
    • 2014
  • Purpose: To investigate the effect of anterior, posterior corneal astigmatism and total corneal astigmatism on posterior corneal astigmatism by analyzing correlation. Methods: Participants were 31 patients (31 eyes) without corneal disease at the age range of 22 to 28 who had visited hospital to receive corneal refractive surgery. The total corneal astigmatism and anterior and posterior corneal astigmatism were measured using a rotating scheimpflug camera before surgery. The magnitude of astigmatism was calculated with the difference between the meridian of the steep refractive power and the flat, and With-The-Rule and inverse astigmatism were divided according to the direction of the meridian that was the steepest. Results: The averages of total corneal astigmatism and anterior and posterior astigmatism were found to be $1.13{\pm}0.76D$, $1.51{\pm}0.84D$, and $-0.59{\pm}0.17D$. The magnitude of posterior corneal astigmatism was distributed between -1.0 D and -0.25 D in all the subjects, and when the magnitude of total corneal astigmatism was set as 100, the magnitude of anterior corneal astigmatism was $142.9{\pm}29.9%$. Total corneal astigmatism indicated the highest correlation with the magnitude of anterior astigmatism (y = 0.871x-0.184, $R^2=0.982$) and high negative correlation with posterior astigmatism (y = -2.974x-0.184, $R^2=0.698$). All the subjects' anterior and posterior corneal astigmatism was classified into With-The-Rule. Conclusions: Anterior and posterior corneal astigmatism in the subjects in their 20's showed the magnitude of -3.8 D in 0.2 D and -0.25 D in -1.0 D separately, and both anterior and posterior astigmatism indicated a high percentage of With-The-Rule.

Impact Resistance Testing of NK55 Ophthalmic Lenses in Domestic Market (국내 유통 NK55 재질 안경렌즈의 내충격 시험 평가)

  • Park, Mijung;Jeon, Inchul;Hwang, Kwang Hoon;Byun, Woongjin;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • Purpose: The present study was performed to evaluate the safety of ophthalmic lenses in domestic market since eyeglasses wearers could be exposed to the negligent accident by damaged ophthalmic lenses. Method: Totally, 160 ophthalmic lenses (NK55, ${n_{d}}$ = 1.56) with the refractive powers of -3D, -6D, +3D, +6D manufactured by 4 companies in domestic market were evaluated using drop ball test. In accordance with FDA standard, steel ball (~16 g) was freely dropped on these ophthalmic lenses from 127 cm high and the surfaces of lenses were observed. Results: From the study, center thicknesses of NK55 ophthalmic lenses manufactured by 4 different companies showed somewhat different numbers even though the lenses had the same refractive index and powers. All convex lenses of +3D, +6D were evaluated as the safe lenses since there was no damage such as crack and broken found on the lens surfaces after drop ball testing. However, some noticeable broken was shown on the surfaces of concave lenses with relatively thinner center thickness. Especially, 59(73.8%) of total 80 concave lenses with the refractive power of -3D and -6D classified as unacceptable lenses to FDA standard. Conclusions: From the results, the negligent accident by damaged ophthalmic lenses should be considered as well as the correction of visual acuity, design and price when customers purchase eyeglasses. Thus, the enforcement regulation like drop ball testing of uncut ophthalmic lens could be suggested to guarantee the safety of ophthalmic lenses in domestic market.

The study of binocular function of college students (대학생들의 시기능에 대한 연구)

  • Cho, Young-Rae;Park, Hyun-Ju;Seo, Ji-Keun;Seong, Jeong-Sub;Kim, Jae-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.103-110
    • /
    • 2005
  • Binocular vision had a short history in Korea. As there were many near works in these days, the needs about comparative study have been increased. There was related to both refractive error and binocular anomalies, but it is difficult to applying for binocular vision expected findings in itself due to the fact that Korean differ from foreigner. Objects were 100 adults in 18-36 years old ages, The test was Von Gaefe method and used aparatus was phoropter(Shinnippon VT10)and visual chart(Shinnippon CT30). According to interview results was that symptom in near works were headaches 28.0%, blinking 27.3%, red eye 25.1%, eyepain 15.6%, watering 15.3%, itch 12.2%, photophobia 8.5% and eye strain 7.4%. A people who have above ${\pm}0.50$ D refractive error in total objectives (100-male 45/female 55) were classified into ametropia. There was a results such as emmetropia (12.0%), ametropia(88.0%), exophoria(32.0%), esophoria(12.0%). Far negative relative convergence were that in case of high 43.0%, in case of low 7.0%. Far positive relative convergence were that in case of high 15.0%, in case of low 38.0%. Near phoria was exophoria(32.0%), esophoria(12.0%). Near negative relative convergence were that in case of high 23.0%, in case of low 38.0%. Far positive relative convergence were that in case of high 29.0%, in case of low 23.0%. Near negative relative accommodation were that in case of high 10.0%, in case of low 14,0%, Far positive relative convergence were that in case of high 69.0%, in case of low 12.0%. Results were different from expected findings, and especially positive relative accommodation was very high, However, We suggest that the expected findings in Korea for several subjects must study in binocular function.

  • PDF

The Factors Influencing the Asthenopia of Myopia with Phoria (사위를 가진 근시안의 안정피로에 영향을 미치는 요인)

  • Kim, Jung-Hee;Kim, Chang-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.419-428
    • /
    • 2005
  • The aim of this study was to provide data for the relief of asthenopia during binocular vision by determining the characteristics of ocular function in adults. A total of 260 subjects were between the age of 19-35years. We measured individually the refractive error correction, pupillary distance, optical center distance, phoria, convergence, accommodation and the AC/A as well as the asthenopia during binocular vision using a questionnaire. After analysis of factors affecting asthenopia, we also examined the reductive effect of asthenopia in subjects who had asthenopia using prism. To determine the factors affecting asthenopia during binocular vision, statistic analyses were carried out the multivariate Logistic regression model. The results of this study were as follow. The asthenopia during binocular vision was found 26.9% of subjects. Multivariate logistic regression model was used to determine factors affecting binocular vision of myopia. When the accommodation and convergence were low compared to being high, when subjects had esophoria or there was more exophoria, and when AC/A was lower than the standard, the rate of asthenopia was higher. Therefore the accommodation, convergence and AC/A could be predictive factors for asthenopia. We used prism for subjects who had asthenopia during binocular vision, the results showed that the symptom of asthenopia was eased up to 74.3%.

  • PDF

Growth of $LiTaO_3$ and Fe doped-LiTaO3 single crystal as holographic storage material (홀로그래피 소자재료 $LiTaO_3$단결정 성장)

  • 김병국;윤종규
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.2
    • /
    • pp.193-204
    • /
    • 1998
  • The single crystal of the $LiTaO_3$has large electro-optic effects, so it is applied to optical switch, acousto-optic deflector, and optical memory device as hologram using photorefractive effect. In this study, optic-grade undoped $LiTaO_3$and Fe:LiTaO$LiTaO_3$single crystals were grown by the Czochralski method and optical transmission and absorption spectrums were measured in the wavelength of UV-VIS range. The curie temperature was determined with DSC and by measuring capacitance for the grown undoped crystal and ceramic powder samples of various Li/Ta ratio. In case of having a 48.6 mol% $Li_2O$ as a starting Li/Ta ratio, the results of concentration variations were below 0.01 mol% $Li_2O$ all over the crystal, so it was confirmed that $LiTaO_3$single crystals were grown under congruent melting composition having optical homogeneity. The curie temperature of the Fe:$LiTaO_3$crystal was increased with increased with increased doped Fe concentrations;by the ratio of $7.5^{\circ}C$ increase per Fe 0.1 wt%. Also, the optical transmittance was about 78 %, which was sufficient for optical device.

  • PDF

Induced Prisms of Wearing Glasses Measured by Photographing (사진촬영으로 측정한 착용안경의 유발프리즘)

  • Shin, Hyung-Sup;Jang, Jun-Kyu
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.527-532
    • /
    • 2014
  • Purpose: The matching of the optical center and the pupil center was measured by photographs in wearing glasses. In this study, the influences of the induced prism by the mismatching are studied. Methods: 74 subjects (148 eyes) who were spectacles wearer were participated in this study. The mean age was $29.19{\pm}12.22$ years (range 19-55 years). The facial photographs of subjects were taken while wearing spectacles. The matching of the corneal reflected image and optical center of the spectacle lens in the horizontal deviations, and the vertical deviations were measured by the observation of the photo image. The prisms induced in accordance with various frame type were calculated from the mismatching deviations. Results: The binocular horizontal deviations were $1.55{\pm}1.70mm$ for the metal frame, $1.71{\pm}2.21mm$ for the clings type plastic frame, and $1.15{\pm}1.38mm$ for the plastic frame. In the horizontal direction induced prism, the ratio over the tolerance was 23%. The ratio were the 17.6% at the BI prism, and 5.4% at the BO prism. The binocular vertical deviation comparisons were $3.93{\pm}1.91mm$ for the metal frame, $5.79{\pm}1.93mm$ for the clings type plastic frame, and 1$6.01{\pm}2.94mm$ for the plastic frame. In the vertical direction induced prism, the ratio over the tolerance was 44.6%. Based on the refraction power, the ratio were 12.2% at -0.25${\leq}-3.00$, and 32.4% at -3.00${\leq}-12.00D$. Conclusions: The induced prisms in the horizontal direction were much in the BI prism. The binocular vertical deviations of the glasses.