• Title/Summary/Keyword: 광 콜리메이터

Search Result 6, Processing Time 0.032 seconds

Optical Microphone Incorporating a Reflective Micromirror and a Dual-core Collimator (반사형 마이크로미러와 듀얼 코어 클리메이터를 이용한 광 마이크로폰)

  • Song, Ju-Han;Kim, Do-Hwan;Gu, Hyun-Mo;Park, Hyun-Jung;Lee, Sang-Shin;Cho, Il-Joo
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.1
    • /
    • pp.94-98
    • /
    • 2006
  • An optical microphone based on a dual-core fiber collimator and a membrane type micromirror serving as an optical head and a reflective diaphragm respectively was implemented. The micromirror diaphragm is suspended by a thin silicon bar linked with a frame, thus it is subject to a displacement induced by acoustic waves. The optical head incorporating two collimators integrated in a single housing gives light to and receives it from the diaphragm, rendering the optical microphone structure simple and compact. This dual-core collimator having a slowing varying beam profile facilitates the initial alignment of the optical head with the diaphragm, especially the distance between them. For the assembled microphone, the static characteristics were investigated tofind the operation point defined as the optimum distance between the head and the diaphragm, and a frequency response with a variation of about $\pm$5 dB for the range of up to 3kHz was achieved.

Development of an Optical Alignment Control Module with High Speed and Accuracy for Optics-Based Products (광학제품을 위한 고속.고정밀 광정렬 제어 모듈 개발)

  • Kim Seung-Chul;Kim Gyung-Bum
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.5 s.182
    • /
    • pp.103-110
    • /
    • 2006
  • Automatic optical alignment modules are a key technology in optical communication system. However, the optic component assembly depends highly on manual or semi-automated alignment process. In this paper, a novel alignment mechanism with minimum degree-of-freedom has been designed and theoretical models are derived from geometric optical characteristics on collimators, optical filters and optical ray alignment. The automatic alignment control algorithm has been newly developed based on the mechanism and models, and then we make fast, precise and reliable alignment through the algorithm. The reliability of developed modules has been verified with various simulations and performance evaluations.

A Study on a position detection of radiation using CCD camera (영상센서를 이용한 방사선원 위치탐지 연구)

  • Lee, Nam-Ho;Choi, Chang-Whan;Shin, Ho-Chul;Jun, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.324-326
    • /
    • 2006
  • CCD형 영상소자는 방사선 피폭 시 표면과 격자내부에 모두 손상을 받게 되며, 감마방사선이나 X선과 같은 고에너지의 이온화 방사선에 노출될 경우 격자 실리콘 내부에 전자-전공쌍(Electron-hole pair, EHP)이 발생된다. 이러한 EHP는 CCD의 순간 출력 광전류로 변환되어 백색 화소 형태의 영상잡음으로 가시화되며, 이 화소 수는 피폭 방사선량에 비례하여 증가하는 특성을 지니고 있다. 따라서 출력 영상정보를 분석하면 조사된 방사선의 양과 특성을 측정할 수 있다. 본 연구에서는 CCD를 이용하여 가상의 방사능 물질 누출 공간에서 방사선원의 방향과 거리정보를 고속으로 탐지하기 위한 장치와 고속 측정 알고리즘을 구현하고 실제 방사선장에서 실증시험을 수행하였다. 방사선 탐지기는 콘형 납 콜리메이터(Collimator)와 가시광 변환용 신틸레이터(CsITl) 및 차폐체로 구성된 센서부와 제어 및 방사광 신호처리를 수행하는 PC부로 구성된다. 감마방사선($^{60}Co$) 방사선장 실증시험에서 방사선원간 거리 83cm에서 측정된 거리 탐지는 5.3%의 오차로 확인되었다. 이 방사선 탐지기는 임의의 고방사선 누출사고에 대한 초기대응 작업을 수행하기 위한 무인 이동로봇용 방사선 탐지기로 활용이 가능하다.

  • PDF

Analysis add Comparison of the Performance of Optical Collimator by Lenses (렌즈에 따른 광콜리메이터 성능 비교 분석)

  • 선화영;최두선;제태진;최기봉;김동식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.132-136
    • /
    • 2002
  • Optical collimating lenses are play a role as maintenance parallel light and as a kind of optical collimating lens, there is Ball lenses, GRIN-rod lenses, spherical lenses and aspherical lenses etc. but recently GRIN lens has monopolized a market. The performance of optical collimator depended on the coupling efficiency. In this paper, we were compared and analyzed to be measured values of coupling efficiency with respect to optical working distance using GRIN rod lenses and spherical lenses. In the case of GRIN lenses with a beam size of 420 ${\mu}{\textrm}{m}$, the minimum coupling efficiency was obtained to a measured value of 0.15 ㏈ and in the case of spherical lenses was obtained to a measured value of 0.12 ㏈ on the same condition. In results, we found that a performance of spherical lenses be better as compared with a that of GRIN lens.

  • PDF

Alignment method of the secondary mirror of high resolution electro-optical payload using collimator and wave front sensor (콜리메이터와 파면측정기를 이용한 고해상도 전자광학 탑재체의 제2 반사경 정렬법)

  • Jang, Hong-Sul;Jung, Dae-Jun;Youk, Young-Chun;Kim, Seong-Hui;Ko, Dai-Ho;Lee, Seung-Hoon
    • Aerospace Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.101-104
    • /
    • 2011
  • For high resolution electro-optical payload, the alignment and assembly of the secondary mirror with respect to the primary mirror is the most important step of the whole camera assembly process. For the purpose of the secondary mirror alignment, Wave front sensor and Collimator would rather be useful than the interferometer because of its small size and easiness of handling. In this paper the brief alignment procedure and method of the secondary mirror of a high resolution electro-optical camera system was introduced.

Verification of Target Position in Stereotactic Radiosurgery Based on Photon Knife System (Photon Knife 시스템에 근거한 뇌정위 방사선수술에서 표적위치 확인)

  • 최태진;김진희;김옥배
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.99-107
    • /
    • 2003
  • This study was performed to prepare the verification film for localizing beam-target position with the Photon Knife radiosurgery system (PKRS) using linear accelerator(Mitsubishi, Model ML-15MDX). We developed a laser calibration system using a reticle of transparent lucite to detect Inlet and outlet beams. We verified fixation of the second collimator with film mounted on a holder in the shape of an octagon block 5cm apart from the isocenter. The film was exposed to photon beams of linear accelerator at an interval of 45 degrees during the gantry movement. There were no shifts in the beam of the second collimator during gantry movement. We used a position marker which is designed a head-shaped small lead block and a 10 mm in diameter of steel bead in the plastic tube. The position marker helped to verify the beam directions with patient position in multi-arc and trans-multi-arc of PKRS The verification of beam alignments showed an average 0.8$\pm$0.26 mm discrepancy in LINAC-gram images of PKRS. In our study, the couch movement was $\pm$5 mm laterally, while it shook $\pm$ 2 mm toward the couch axis. The couch, however, was immediately returned to the initial site after shaking. Thus, we postulate that the beam-target position(s) should be verified with LINAC-gram in a stereotactic radiosurgery system to achieve the accuracy of beam-target alignment.

  • PDF