• Title/Summary/Keyword: 광 상관

Search Result 669, Processing Time 0.032 seconds

A Study On Performance of Fiber Optic CDMA System for Parallel Transmission of Two Dimensional Data (2차원 데이터의 병렬전송을 위한 광부호분할 다중접속 시스템의 성능에 관한 연구)

  • 이태훈;박영재;박진배
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.1B
    • /
    • pp.1-7
    • /
    • 2000
  • Generally, one-dimensional fiber optic code-division multiple-access(CDMA) system is encoded and decoded using optical orthogonal codes(OOC’s), where two-dimensional fiber optic CDMA system uses optical orthogonal signature pattern codes(OOSPC’s) for parallel data link process. The OOSPC’s should have good autocorrelation and cross-correlation properties. However, if timing information or synchronization of OOSPC’s can be obtained by other means, the property of autocorrelation may not be restricted and we can increase the number of pattern codes. In this paper we introduce the fiber optic CDMA system for parallel transmission of two-dimensional data and investigate methods of generation of two-dimensional pattern codes. The probability density function of interference noise is calculated in interfering OOSPC’s of the users and the corresponding bit error rate is derived.. We compare each OOSPC’s by plotting bit error rate versus threshold values and the number of simultaneous users, from the result, we propose the optimal OOSPC’s conditions for the parallel transmission of two-dimensional data.

  • PDF

Correlation Analysis of Reflectance and Turbidity through Spectral Characteristics of Near-Infrared (근적외선의 분광특성 분석을 통한 반사율과 탁도의 상관관계 분석)

  • Lee, So-Jin;Jeong, Gyo-Cheol;Lee, Chang-Ju;Kim, Jong-Tae
    • The Journal of Engineering Geology
    • /
    • v.32 no.1
    • /
    • pp.101-111
    • /
    • 2022
  • This study analyzed the relationship between water turbidity and its reflectance, as measured using hyperspectral imaging. First, samples of turbid water were generated in boxes. This was followed by drone-based hyperspectral imaging and analysis of the correlation between the samples' measured turbidity and hyperspectral reflectance. The nine boxes for turbidity measurement were made of black acrylic that absorbed all light turbidity was induced using soil collected near Changhacheon, which causes turbidity in Imha Lake. The results indicate that the reflectance of wavelengths in the near-infrared region followed a pattern of increase with increasing soil content for each box. Analysis of this correlation between the turbidity and average reflectance measured in each box yielded a very high R2 value of 0.8702, indicating that reflectance is a suitable proxy for turbidity.

Performance evaluation of hyperspectral image for morphological mapping (초분광 영상을 활용한 하상 측정 성능 평가 )

  • Youngcheol Seo;Dongsu Kim;Hojun You;Yeonghwa Gwon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.225-225
    • /
    • 2023
  • 하상 측정은 하천 유지관리, 수공구조물 설계 및 보수, 수생태 조사의 필수적인 자료이다. 최근 4대강 대규모 사업 이후 자연적 안정화로 인해 침식 및 재퇴적이 진행되어 정밀 하상 모니터링이 요구되고 있다. 통상적인 하상 조사 기법은 레벨측량 및 RTK-GPS 등을 활용하여 점단위로 직접 계측하는 기법과 수심이 깊을 경우 ADCP와 같은 음향측심기법을 통해 하상변동을 계측하고 있다. 하지만 점단위 직접 측정은 사구와 사련과 같은 하상 구조 교란 및 계측 시 위험을 동반하고 수심자료의 측정오차가 크게 발생하는 한계점이 존재한다. 또한 초음파 방식의 경우 막음길이와 바닥면 노이즈 등의 한계점으로 50 cm 미만의 저수심부 하상 측정이 불가능한 실정이다. 이러한 한계점을 극복하기 위해 최근 드론의 보급으로 수심라이다(Bathymetry LiDAR), SFM, 드론 탑재 초분광 영상을 활용한 초분광수심법과 같은 저고도, 고해상도의 비접촉식 면단위 하상 측정 기법이 대안으로 각광받고 있고 최근 관심은 해당 최신 기술의 성능 점검 및 적용성 평가에 있다. 따라서 본 연구에서는 초분광수심법 중 보편적으로 적용할 수 있는 최적밴드비분석(OBRA)의 성능 점검과 실무 적용성을 국내 하천을 대상으로 검토하였다. 해당 기술의 실무 적용성 평가항목 중 수심 적용 범위가 경제적이고 효율적인 성능 평가의 주된 항목이다. 선행 연구에 따르면 감천을 대상으로 저수심부의 성능 평가를 진행한 결과 상세한 하상계측이 가능하다고 제시하였다. 따라서 본 연구는 낙동강-황강 합류부를 대상으로 전형적인 평수기 탁도 조건에서 초분광수심법을 적용할 경우 최대측정가능수심의 범위를 결정하는 방법 및 결과를 제시하려고 한다. 또한 현장실험 당시 합천댐 방류로 인하여 황강의 탁도가 높아진 상태에 기인하여 고탁도 조건에서 초분광수심법의 적용성 평가도 추가 검토하였다. 해당 연구는 수심과 밴드비의 비선형성을 통해 최적 밴드비 분석의 결과로 도출될 수 있는 상관계수와 평균 제곱근 오차(RMSE)의 동향을 보아 다양한 시나리오의 배제수심을 통해 최대측정가능수심을 산정하였으며 그 이상의 범위는 수심맵 산정에서 제외하였다. 그 결과로 낙동강 본류에서 2.5 m 이하, 황강 지류에서 1.25 m 이하의 최대측정가능수심이 나타났고 해당 범위 이하에서는 상세한 하상이 나타났다. 또한 고탁도 조건인 황강에서는 낙동강에 비해 절반 수준의 최대측정가능수심 범위가 나타나 탁도 조건에 따른 초분광수심법의 한계가 있는 것을 확인하였다.

  • PDF

Development of Suspended Sediment Concentration Measurement Technique Based on Hyperspectral Imagery with Optical Variability (분광 다양성을 고려한 초분광 영상 기반 부유사 농도 계측 기법 개발)

  • Kwon, Siyoon;Seo, Il Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.116-116
    • /
    • 2021
  • 자연 하천에서의 부유사 농도 계측은 주로 재래식 채집방식을 활용한 직접계측 방식에 의존하여 비용과 시간이 많이 소요되며 점 계측 방식으로 고해상도의 시공간 자료를 측정하기엔 한계가 존재한다. 이러한 한계점을 극복하기 위해 최근 위성영상과 드론을 활용하여 촬영된 다분광 혹은 초분광 영상을 통해 고해상도의 부유사 농도 시공간분포를 측정하는 기법에 대한 연구가 활발히 진행되고 있다. 하지만, 다른 하천 물리량 계측에 비해 부유사 계측 연구는 하천에 따라 부유사가 비균질적으로 분포하여 원격탐사를 통해 정확하고 전역적인 농도 분포를 재현하기는 어려운 실정이다. 이러한 부유사의 비균질성은 부유사의 입도분포, 광물특성, 침강성 등이 하천에서 다양하게 분포하기 때문이며 이로 인해 부유사는 지역별로 다양한 분광특성을 가지게 된다. 따라서, 본 연구에서는 이러한 영향을 고려한 전역적인 부유사 농도 예측 모형을 개발하기 위해 실내 실험을 통해 부유사 특성별 고유 분광 라이브러리를 구축하고 실규모 수로에서 다양한 부유사 조건에 대한 초분광 스펙트럼과 부유사 농도를 측정하는 실험을 수행하였다. 실제 부유사 농도는 광학 기반 센서인 LISST-200X와 샘플링을 통한 실험실 분석을 통해 계측되었으며, 초분광 스펙트럼 자료는 초분광 카메라를 통해 촬영한 영상에서 부유사 계측 지점에 대한 픽셀의 스펙트럼을 추출하여 구축하였다. 이렇게 생성된 자료들의 분광 다양성을 주성분 분석(Principle Component Analysis; PCA)를 통해 분석하였으며, 부유사의 입도 분포, 부유사 종류, 수온 등과의 상관관계를 통해 분광 특성과 가장 상관관계가 높은 물리적 인자를 규명하였다. 더불어 구축된 자료를 바탕으로 기계학습 기반 주요 특징 선택 알고리즘인 재귀적 특징 제거법 (Recursive Feature Elimination)과 기계학습기반 회귀 모형인 Support Vector Regression을 결합하여 초분광 영상 기반 부유사 농도 예측 모형을 개발하였으며, 이 결과를 원격탐사 계측 연구에서 일반적으로 사용되어 오던 최적 밴드비 분석 (Optimal Band Ratio Analysis; OBRA) 방법으로 도출된 회귀식과 비교하였다. 그 결과, 기존의 OBRA 기반 방법은 비선형성을 증가시켜도 좁은 영역의 파장대만을 고려하는 한계점으로 인해 부유사의 다양한 분광 특성을 반영하지 못하였으며, 본 연구에서 제시한 기계학습 기반 예측 모형은 420 nm~1000 nm에 걸쳐 폭 넓은 파장대를 고려함과 동시에 높은 정확도를 산출하였다. 최종적으로 개발된 모형을 적용해 다양한 유사 조건에 대한 부유사 시공간 분포를 매핑한 결과, 시공간적으로 고해상도의 부유사 농도 분포를 산출하는 것으로 밝혀졌다.

  • PDF

Implementation of machine learning-based prediction model for solar power generation (빅데이터를 활용한 머신러닝 기반 태양에너지 발전량 예측 모델)

  • Jong-Min Kim;Joon-hyung Lee
    • Convergence Security Journal
    • /
    • v.22 no.2
    • /
    • pp.99-104
    • /
    • 2022
  • This study provided a prediction model for solar energy production in Yeongam province, Jeollanam-do. The model was derived from the correlation between climate changes and solar power production in Yeongam province, Jeollanam-do, and presented a prediction of solar power generation through the regression analysis of 6 parameters related to weather and solar power generation. The data used in this study were the weather and photovoltaic production data from January in 2016 to December in 2019 provided by public data. Based on the data, the machine learning technique was used to analyzed the correlation between weather change and solar energy production and derived to the prediction model. The model showed that the photovoltaic production can be categorized by the three-stage production index and will be used as an important barometer in the agriculture activity and the use of photovoltaic electricity.

저압 광 산란 입자측정센서의 신호 분석 알고리즘 연구

  • Mun, Ji-Hun;Yun, Jin-Uk;Jeong, Hyeok;Gwon, Yong-Taek;Gang, Sang-U;Yun, Ju-Yeong;Sin, Yong-Hyeon;Kim, Tae-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.35-35
    • /
    • 2011
  • 반도체 공정 및 디스플레이 공정에서 발생하는 오염입자는 공정 불량을 일으키는 가장 큰 원인 중의 하나이며, 수십 나노에서 수 백 나노의 크기를 갖는다. 최근 디스플레이 및 반도체 산업이 발전함에 따라 회로의 선폭이 점차 감소하고 있으며 오염입자의 임계 직경(critical diameter) 또한 작아지고 있다. 현재 반도체 및 디스플레이 산업에서 사용되는 측정방법은 레이저를 이용하여 공정 후 표면에 남아있는 오염입자를 측정하는 ex-situ 방법이 주를 이루고 있다. Ex-situ 방법을 이용한 오염입자의 제어는 웨이퍼 전체를 측정할 수 없을 뿐만 아니라 실시간 측정이 불가능하기 때문에 공정 모니터링 장비로 사용이 어려우며 오염입자와 공정 간의 상관관계 파악에도 많은 제약이 따르게 된다. 이에 따라 저압에서 in-situ 방법을 이용한 실시간 오염입자 측정 기술 개발이 요구되고 있다. 본 연구에서는 저압 환경에서 실시간으로 입자를 모니터링 할 수 있는 장비를 입자의 광 산란 원리를 이용하여 개발하였으며, 산란 신호를 입자크기로 변환하는 신호 분석 알고리즘 연구를 수행하였다. 빛이 입자와 충돌하게 되면 산란 및 흡수 현상이 발생하게 되는데 이 때 발생하는 산란 및 흡수량과 입자 크기와의 연관성이 Gustav Mie에 의해서 밝혀졌으며, 현재까지 광을 이용한 입자 크기 분석 장치의 기본 원리로 사용되고 있다. 하지만, Mie 이론은 단일입자가 일정한 강도를 가진 광을 통과할 경우인 이상적인 조건에서 적용이 가능하고 실제 조건에서는 광이 가우시안 분포를 가지며 광 집속에 의해서 광 강도가 위치에 따라 변하기 때문에 이러한 조건을 가지는 광을 입자가 통과할 때 발생하는 산란량은 단순히 Mie 이론에 의해서 계산하는 것이 불가능 하다. 본 연구에서는 이러한 현상을 입자 측정의 불확정성 이라고 규정하고 입자가 특정한 위치를 통과할 확률을 이용하여 신호를 분석하는 알고리즘을 개발 및 연구를 수행하였다.

  • PDF

Symbolic Substitution Based on Optical Correlator for Optical Parallel Addition with Redundant Binary Number (잉여 이진수 광병렬 가산을 위한 광상관 기호치환)

  • 노덕수;김정우;조웅호;김수중
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.1
    • /
    • pp.269-280
    • /
    • 1996
  • We proposed a symbolic substitution method based on an optical correlator for an optical parallel addition. In the proposed symbolic substitution method, we used redundant binary number of the symbolic substitution rules as a number system and chose MAC3E filter which had very low sidelobes and good correlation peak compared with SDF filter as the optical correlation filter. We encoeded input numbers property to increase the discrimination capability and divided inpt patterns into 5 groups of the same addition results to minimize the number of symbolic substitution rules. Through the computer simulation, we confirmed the proposed method was suitable to implement the optical parallel adder.

  • PDF

Irradiation and Power Analysis According to Months (태양광 시스템의 월별 일사량과 전력량)

  • Jung, You-Ra;Kim, Seok-Gon;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.205-205
    • /
    • 2009
  • 태양광 발전은 다른 발전방식과는 달리 연료비가 불필요하고 대기오염이나 폐기물 발생이 없으며 부위가 반도체 소자이고 제어부가 전자제품이므로 기계적인 진동과 소음 등의 공해가 전혀 없는 에너지원이다. 그러나 태양광 발전은 에너지 밀도가 낮아 일사량, 온도, 계절 등 기상조건의 작은 변화에도 발전량의 편차가 심하고 출력이 불안정하여 상용전원과의 연계나 별도의 축전설비 또는 발전설비 없이 독립적으로 사용하기에는 다소 무리가 있다는 단점이 있다. 따라서 본 논문에서는 이러한 문제점을 해결하기 위해서 1년 동안 실증운전을 통한 종합적인 운전특성 데이터, 태양전지 어레이 출력의 전압 전류, 교류 전력 및 전력량, 일사량 및 모듈의 온도, 외기온도 등 분석기간 동안 수집된 운전 데이터를 이용하여 태양이 태양전지 모듈에 입사되는 각과 발전량 즉 태양 전지 어레이 형태와 발전량과의 상관관계를 정량적으로 규명하여 태양광 발전시스템의 설계 및 시공의 최적화가 이루어질 수 있도록 하였다.

  • PDF

Effects of the decorrelation on the coincidence detection with correlated photons in a parametric down-conversion (매개하향변환 과정에서 발생하는 광자쌍의 상관관계에 따른 동시계수 측정)

  • 김헌오;고정훈;김태수
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.6
    • /
    • pp.431-436
    • /
    • 2001
  • The effect of decorrelation on the coincidence is investigated with correlated photons produced by parametric down-conversion process. The degree of correlation between photon pairs is adjusted by changing the polarization dependent transmissivities of thin glass plate\ulcorner in front of two detectors. It was found that the single counts of each detectors are proportional to the transmissivity and the coincidence is proportional to the product of transmissivities of the glasses in front of two detectors.

  • PDF

DEVELOPMENT OF FILTERING SYSTEM OF LASER FLUORESCENCE FOR IMPROVEMENT OF THE DIAGNOSTIC SENSITIVITY FOR DENTAL CARIES (레이저 형광법의 치아우식증 진단감도를 증진시키기 위한 필터링 시스템 개발)

  • Lee, Sang-Ho;Park, Jong-Whi;Kook, Jung-Ki;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.189-195
    • /
    • 2003
  • The objective of this study is to improve the optical sensitivity of laser fluorescence for detection of incipient enamel caries. An incipient carious lesion was formed in various stages by placing an enamel specimen of a bovine tooth in STPP demineralization solution. After measuring the optical density of the lesion surface by laser fluorescence induced by argon laser and various alter of yellow(500-520nm), amber(520-540nm), orange(540-560nm), and red(560-580nm), the specimen was cut vertically to measure the depth of the lesion using a polarizing microscope. SAS statistical program was used to analyze the relationship between the optical density of the lesion suface and the depth of the lesion. The results were as follows: 1. The optical density of early carious lesion, measured by laser fluorescence with amber and orange filter, and lesion depth observed by polarizing microscope, were increased as demineralization time increased. 2. The correlation coefficient between optical density of the lesion surface and the histological depth of the lesion was the highest in orange filter(r=0.49), followed by amber(r=0.32), yellow(r=0.13) and red(0.01). 3. Regression analysis showed that the most linear relationship between the optical density and the lesion depth was existed in orange filter group. In regard above results, laser fluorescence could be considered to be reliable for optical diagnosis of dental caries.

  • PDF